Title: Double diffusion encoding MRI for the clinic
Purpose

The purpose of this study is to develop double diffusion encoding (DDE) MRI methods for clinical use. Microscopic diffusion anisotropy measurements from DDE promise greater specificity to changes in tissue microstructure compared with conventional diffusion tensor imaging, but implementation of DDE sequences on whole‐body MRI scanners is challenging because of the limited gradient strengths and lengthy acquisition times.

Methods

A custom single‐refocused DDE sequence was implemented on a 3T whole‐body scanner. The DDE gradient orientation scheme and sequence parameters were optimized based on a Gaussian diffusion assumption. Using an optimized 5‐min DDE acquisition, microscopic fractional anisotropy (μFA) maps were acquired for the first time in multiple sclerosis patients.

Results

Based on simulations and in vivo human measurements, six parallel and six orthogonal diffusion gradient pairs were found to be the minimum number of diffusion gradient pairs necessary to produce a rotationally invariant measurement of μFA. Simulations showed that optimal precision and accuracy of μFA measurements were obtained using b‐values between 1500 and 3000 s/mm2. The μFA maps showed improved delineation of multiple sclerosis lesions compared with conventional fractional anisotropy and distinct contrast from T2‐weighted fluid attenuated inversion recovery and T1‐weighted imaging.

Conclusion

The μFA maps can be measured using DDE in a clinical setting and may provide new opportunities for characterizing multiple sclerosis lesions and other types of tissue degeneration. Magn Reson Med 80:507–520, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

 
more » « less
NSF-PAR ID:
10048445
Author(s) / Creator(s):
 ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Magnetic Resonance in Medicine
Volume:
80
Issue:
2
ISSN:
0740-3194
Page Range / eLocation ID:
p. 507-520
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Purpose

    A new method for enhancing the sensitivity of diffusion MRI (dMRI) by combining the data from single (sPFG) and double (dPFG) pulsed field gradient experiments is presented.

    Methods

    This method uses our JESTER framework to combine microscopic anisotropy information from dFPG experiments using a new method called diffusion tensor subspace imaging (DiTSI) to augment the macroscopic anisotropy information from sPFG data analyzed using our guided by entropy spectrum pathways method. This new method, called joint estimation diffusion imaging (JEDI), combines the sensitivity to macroscopic diffusion anisotropy of sPFG with the sensitivity to microscopic diffusion anisotropy of dPFG methods.

    Results

    Its ability to produce significantly more detailed anisotropy maps and more complete fiber tracts than existing methods within both brain white matter (WM) and gray matter (GM) is demonstrated on normal human subjects on data collected using a novel fast, robust, and clinically feasible sPFG/dPFG acquisition.

    Conclusions

    The potential utility of this method is suggested by an initial demonstration of its ability to mitigate the problem of gyral bias. The capability of more completely characterizing the tissue structure and connectivity throughout the entire brain has broad implications for the utility and scope of dMRI in a wide range of research and clinical applications.

     
    more » « less
  2. Abstract Purpose

    One standard method, proton resonance frequency shift, for measuring temperature using magnetic resonance imaging (MRI), in MRI‐guided surgeries, fails completely below the freezing point of water. Because of this, we have developed a new methodology for monitoring temperature with MRI below freezing. The purpose of this paper is to show that a strong temperature dependence of the nuclear relaxation timeT1in soft silicone polymers can lead to temperature‐dependent changes of MRI intensity acquired withT1weighting. We propose the use of silicone filaments inserted in tissue for measuring temperature during MRI‐guided cryoablations.

    Methods

    The temperature dependence ofT1in bio‐compatible soft silicone polymers was measured using nuclear magnetic resonance spectroscopy and MRI. Phantoms, made of bulk silicone materials and put in an MRI‐compatible thermal container with dry ice, allowed temperature measurements ranging from –60°C to + 20°C.T1‐weighted gradient echo images of the phantoms were acquired at spatially uniform temperatures and with a gradient in temperature to determine the efficacy of using these materials as temperature indicators in MRI. Ex vivo experiments on silicone rods, 4 mm in diameter, inserted in animal tissue were conducted to assess the practical feasibility of the method.

    Results

    Measurements of nuclear relaxation times of protons in soft silicone polymers show a monotonic, nearly linear, change with temperature (R2 > 0.98) and have a significant correlation with temperature (Pearson'sr > 0.99,p < 0.01). Similarly, the intensity of the MR images in these materials, taken with a gradient echo sequence, are also temperature dependent. There is again a monotonic change in MRI intensity that correlates well with the measured temperature (Pearson'sr < ‐0.98 andp < 0.01). The MRI experiments show that a temperature change of 3°C can be resolved in a distance of about 2.5 mm. Based on MRI images and external sensor calibrations for a sample with a gradient in temperature, temperature maps with 3°C isotherms are created for a bulk phantom. Experiments demonstrate that these changes in MRI intensity with temperature can also be seen in 4 mm silicone rods embedded in ex vivo animal tissue.

    Conclusions

    We have developed a new method for measuring temperature in MRI that potentially could be used during MRI‐guided cryoablation operations, reducing both procedure time and cost, and making these surgeries safer.

     
    more » « less
  3. Purpose

    Diffusion weighted MRI imaging (DWI) is often subject to low signal‐to‐noise ratios (SNRs) and artifacts. Recent work has produced software tools that can correct individual problems, but these tools have not been combined with each other and with quality assurance (QA). A single integrated pipeline is proposed to perform DWI preprocessing with a spectrum of tools and produce an intuitive QA document.

    Methods

    The proposed pipeline, built around the FSL, MRTrix3, and ANTs software packages, performs DWI denoising; inter‐scan intensity normalization; susceptibility‐, eddy current‐, and motion‐induced artifact correction; and slice‐wise signal drop‐out imputation. To perform QA on the raw and preprocessed data and each preprocessing operation, the pipeline documents qualitative visualizations, quantitative plots, gradient verifications, and tensor goodness‐of‐fit and fractional anisotropy analyses.

    Results

    Raw DWI data were preprocessed and quality checked with the proposed pipeline and demonstrated improved SNRs; physiologic intensity ratios; corrected susceptibility‐, eddy current‐, and motion‐induced artifacts; imputed signal‐lost slices; and improved tensor fits. The pipeline identified incorrect gradient configurations and file‐type conversion errors and was shown to be effective on externally available datasets.

    Conclusions

    The proposed pipeline is a single integrated pipeline that combines established diffusion preprocessing tools from major MRI‐focused software packages with intuitive QA.

     
    more » « less
  4. Purpose

    Provide a direct, non‐invasive diagnostic measure of microscopic tissue texture in the size scale between tens of microns and the much larger scale measurable by clinical imaging. This paper presents a method and data demonstrating the ability to measure these microscopic pathologic tissue textures (histology) in the presence of subject motion in an MR scanner. This size range is vital to diagnosing a wide range of diseases.

    Theory/Methods

    MR micro‐Texture (MRµT) resolves these textures by a combination of measuring a targeted set of k‐values to characterize texture—as in diffraction analysis of materials, performing a selective internal excitation to isolate a volume of interest (VOI), applying a high k‐value phase encode to the excited spins in the VOI, and acquiring each individual k‐value data point in a single excitation—providing motion immunity and extended acquisition time for maximizing signal‐to‐noise ratio. Additional k‐value measurements from the same tissue can be made to characterize the tissue texture in the VOI—there is no need for these additional measurements to be spatially coherent as there is no image to be reconstructed. This method was applied to phantoms and tissue specimens including human prostate tissue.

    Results

    Data demonstrating resolution <50 µm, motion immunity, and clearly differentiating between normal and cancerous tissue textures are presented.

    Conclusion

    The data reveal textural differences not resolvable by standard MR imaging. As MRµT is a pulse sequence, it is directly translatable to MRI scanners currently in clinical practice to meet the need for further improvement in cancer imaging.

     
    more » « less
  5. ABSTRACT BACKGROUND AND PURPOSE

    Numerous sex‐specific differences in multiple sclerosis (MS) susceptibility, disease manifestation, disability progression, inflammation, and neurodegeneration have been previously reported. Previous magnetic resonance imaging (MRI) studies have shown structural differences between female and male MS brain volumes. To determine sex‐specific global and tissue‐specific brain volume throughout the MS life span in a real‐world large MRI database.

    METHODS

    A total of 2,199 MS patients (female/male ratio of 1,651/548) underwent structural MRI imaging on either a 1.5‐T or 3‐T scanner. Global and tissue‐specific volumes of whole brain (WBV), white matter, and gray matter (GMV) were determined by utilizing Structural Image Evaluation using Normalisation of Atrophy Cross‐sectional (SIENAX). Lateral ventricular volume (LVV) was determined with the Neurological Software Tool for REliable Atrophy Measurement (NeuroSTREAM). General linear models investigated sex and age interactions, and post hoc comparative sex analyses were performed.

    RESULTS

    Despite being age‐matched with female MS patents, a greater proportion of male MS patients were diagnosed with progressive MS and had lower normalized WBV (P < .001), GMV (P< .001), and greater LVV (P< .001). In addition to significant stand‐alone main effects, an interaction between sex and age had an additional effect on the LVV (F‐statistics = 4.53,P= .033) and GMV (F‐statistics = 4.59,P= .032). The sex and age interaction was retained in both models of LVV (F‐statistics = 3.31,P= .069) and GMV (F‐statistics = 6.1,P= .003) when disease subtype and disease‐modifying treatment (DMT) were also included. Although male MS patients presented with significantly greater LVV and lower GMV during the early and midlife period when compared to their female counterparts (P< .001 for LVV andP< .019 for GMV), these differences were nullified in 60+ years old patients. Similar findings were seen within a subanalysis of MS patients that were not on any DMT at the time of enrollment.

    CONCLUSION

    There are sex‐specific differences in the LVV and GMV over the MS life span.

     
    more » « less