<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Proliferation of human aortic endothelial cells on Nitinol thin films with varying hole sizes</title></titleStmt>
			<publicationStmt>
				<publisher></publisher>
				<date>06/01/2018</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10053774</idno>
					<idno type="doi">10.1007/s10544-018-0267-7</idno>
					<title level='j'>Biomedical Microdevices</title>
<idno>1387-2176</idno>
<biblScope unit="volume">20</biblScope>
<biblScope unit="issue">2</biblScope>					

					<author>Ming Lun Wu</author><author>Mohanchandra K. Panduranga</author><author>Gregory P. Carman</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[In this paper, we present the effect of micron size holes on proliferation and growth of human aortic endothelial cells (HAECs). Square shaped micron size holes (5, 10, 15, 20 and 25 μm) separated by 10 μm wide struts are fabricated on 5 μm thick sputter deposited Nitinol films. HAECs are seeded onto these micropatterned films and analyzed after 30 days with fluorescence microscopy. Captured images are used to quantify the nucleus packing density, size, and aspect ratio. The films with holes ranging from 10 to 20 μm produce the highest cell packing densities with cell nucleus contained within the hole. This produces a geometrically regular grid like cellular distribution pattern. The cell nucleus aspect ratio on the 10-20 μm holes is more circular in shape when compared to aspect ratio on the continuous film or larger size holes. Finally, the 25 μm size holes prevented the formation of a continuous cell monolayer, suggesting the critical length that cells cannot bridge is between 20 to 25 μm.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="1">Introduction</head><p>Vascular implants with fully covered endothelial cell monolayer are essential for preventing cardiovascular diseases and prolonging vascular patency. The artery lumen requires a functional endothelial monolayer to help prevent atherosclerosis and thrombosis <ref type="bibr">(Lu et al. 2012;</ref><ref type="bibr">Xu et al. 2011)</ref>. However, regenerating a healthy monolayer following denude injury is challenging <ref type="bibr">(Cejna et al. 2003;</ref><ref type="bibr">Chaabane et al. 2013;</ref><ref type="bibr">Barry 2014)</ref>. To understand the re-endothelialization process and improve cell functionalities, engineered micropatterned surfaces are being investigated <ref type="bibr">(Schwarzenbacher et al. 2008;</ref><ref type="bibr">Yoon et al. 2012;</ref><ref type="bibr">Shen et al. 2009)</ref>. However, most studies focus on polymers rather than the metals commonly used for stents.</p><p>O n e w i d e l y s t u d i e d p o l y m e r i s e x p a n d e d Polytetrafluoroethylene (ePTFE) which is typically ~100 &#956;m thick and commonly used as a stent-graft material. Research suggests peripheral limb bypasses composed of ePTFE have a 45% primary patency rate at 5 years <ref type="bibr">(Johnson and Lee 2000)</ref>. This poor patency rate is due to the absence of reendothelialization on the mid-luminal surface, which is grown through anastomotic and transmural ingrowth <ref type="bibr">(Sottiurai et al. 1983</ref>). Multiple studies have been performed on the influence of ePTFE pore size on tissue ingrowth <ref type="bibr">(Campbell et al. 1975;</ref><ref type="bibr">Zhang et al. 2004;</ref><ref type="bibr">Golden et al. 1990;</ref><ref type="bibr">Holubec et al. 1992;</ref><ref type="bibr">Hazama et al. 2004;</ref><ref type="bibr">Hirabayashi et al. 1992;</ref><ref type="bibr">Cejna et al. 2002)</ref>. Results show that endothelial cells infiltrate ePTFE pores larger than 60 &#956;m, while pores smaller than 30 &#956;m stunts the infiltration process <ref type="bibr">(Golden et al. 1990;</ref><ref type="bibr">Holubec et al. 1992;</ref><ref type="bibr">Hazama et al. 2004</ref>). However, as the pore size increases toward 60 &#956;m, the issues of neointimal tissue ingrowth and blood product adhesion also rises and reduce ePTFE's long-term patency <ref type="bibr">(Golden et al. 1990;</ref><ref type="bibr">Hirabayashi et al. 1992)</ref>. Therefore, the efficacy of porous ePTFE vascular grafts still has considerable shortcomings.</p><p>Biodegradable polymer films like PLLA, PLGA, and PCL have also been studied <ref type="bibr">(Salem et al. 2002;</ref><ref type="bibr">Narayan and Venkatraman 2008;</ref><ref type="bibr">Wang et al. 2015a)</ref>. One major difference between these polymer films and ePTFE is that through the thickness holes can be fabricated on these polymers while ePTFE is best represented as a thick complex porous network. The through the thickness holes present in polymers improve the proliferation of endothelial cell by increasing their metabolic functions <ref type="bibr">(Salem et al. 2002;</ref><ref type="bibr">Narayan and Venkatraman 2008)</ref>. In addition, the holes provide direct contact between the endothelial and smooth muscle cells, which is a desirable feature in vascular applications <ref type="bibr">(Wang et al. 2015b)</ref>. A trend is also emerging for low profile vascular grafts whose covering thickness is comparable to the physiological internal elastic membrane <ref type="bibr">(Foin et al. 2014)</ref>. However, many polymer films remain relatively thick (30 &#956;m) as contrasted with metallic thin films (~5 &#956;m). While polymers with &lt;30 &#956;m features, like pillars, were investigated, they are still quite different from a 2-dimensional metallic thin film <ref type="bibr">(Baker et al. 2011)</ref>. Their major differences include requiring a substrate to function, containing large 3-dimensional features, and weak mechanical properties. Due to these differences, a re-endothelialization study on metallic films may provide information that's currently unattainable on a polymer.</p><p>Nickel Titanium, also known as Nitinol, is an autoclavable metal alloy commonly used as the structural component of endovascular devices <ref type="bibr">(Nair et al. 2015)</ref>. Several studies have shown that the smooth Nitinol surface reduces the oxidative stress on endothelial cells and allows them to retain their functionalities based on the expression of cadherin and actin <ref type="bibr">(Plant et al. 2005)</ref>. Researchers have also reported that nano-rough Nitinol surfaces improve the proliferation of endothelial cells when compared to cells grown on a coarse grain surface <ref type="bibr">(Samaroo et al. 2008)</ref>. Studies have begun focusing on ~5 &#956;m Nitinol films with through the thickness micropattern holes to replace the ePTFE coverings on stent, neurovascular diverters, and heart valves <ref type="bibr">(Rigberg et al. 2009;</ref><ref type="bibr">Chun et al. 2009;</ref><ref type="bibr">Stepan et al. 2005;</ref><ref type="bibr">Chun et al. 2010)</ref>. <ref type="bibr">Loger et al.'s (2016)</ref> studies on 10 &#956;m thick Nitinol film with rhombic micropattern (400-1300 square microns) show a completely covered dense layer of fibrous materials in 7 days after cell seeding. However, they did not show endothelial cell could bridge the relatively large holes nor did they evaluate cell morphology. Recent in vivo studies also suggest promising outcomes for transmural ingrowth using micropattern holes. However, <ref type="bibr">Chun et al. 2017</ref> report a negative correlation between micropattern holes and neointimal ingrowth related to hole dimensions suggesting more research is needed.</p><p>The objectives of this study were to evaluate the morphological formation of an endothelial cell monolayer on Nitinol thin films (5 &#956;m thickness) with five different micropatterned through the thickness holes (5-25 &#956;m). Endothelial cells were seeded onto the film and analyzed after thirty-days. The cell packing density and nuclei morphology on the micropatterned films were compared with continuous films without holes. The results show that 10-20 &#956;m holes produce the highest cell packing density and 25 &#956;m were not able to bridge the hole completely. In addition, the cell monolayer on these 10-20 &#956;m holes produce an organized distribution of cells placed at equal distances from one another, with the cell nucleus located within the holes. This is in sharp contrast to the random cell placement normally observed. Finally, the 10-20 &#956;m holes appear to provide mechanical constraints on cell nucleus, altering the nuclei morphology.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2">Materials and method</head><p>Micropatterned Nitinol films were fabricated using photolithography with a chemical lift off technique. Following fabrication, the films were suspended in a PDMS elevating plate and seeded with human aortic endothelial cells (HAECs). Samples were cultured for 30 days and evaluated using fluorescence staining. A description of the fabrication and testing procedures is detailed below.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.1">Fabrication of micropatterned nitinol thin film</head><p>Micropatterned Nitinol thin films were fabricated using a process described in Fig. <ref type="figure">1</ref>, which is a derivative process from previous literatures <ref type="bibr">(Ho and Carman 2000;</ref><ref type="bibr">Chun et al. 2010)</ref>. A 4-in. silicon (Si) wafer with thermally grown 500 nm silicon dioxide (SiO 2 ) was coated with a positive photoresist, AZ5214. The holes geometries were defined using photolithography and advance oxide etcher (Surface Technology System) to create a micropattern into the SiO 2 mask. The Si substrate was subsequently etched with fast deep reactive ion etcher (FDRIE) to generate 50 &#956;m trenches in the silicon wafer. The SiO 2 micropatterned mask was removed with buffer oxide etchant (BOE). Layers of copper and SiO 2 , 500 nm each, were deposited onto the Si wafer using e-beam evaporator and plasma enhanced chemical vapor deposition (PECVD), respectively.</p><p>Copper served as a sacrificial layer for Nitinol lift off, and SiO 2 served as an inhibition layer to prevent copper diffusion during Nitinol deposition. A 5 &#956;m thick Nitinol film was deposited using DC sputtering process with a heated target and removed from the wafer by dissolving the copper in ferric chloride solution. The stand-alone Nitinol films were cleaned with DI water and immersed in BOE to remove any SiO 2 residuals. The micropatterned film was crystallized in an ultrahigh vacuum chamber with pressure 1 &#215; 10 -6 Torr at 500 &#176;C followed by a passivation treatment using nitric acid and a cleaning in acetone, methanol and isopropanol alcohol (IPA).</p><p>Figure <ref type="figure">2a</ref> shows an illustration of the 8.0 mm &#215; 8.0 mm micropatterned Nitinol thin film used for testing. The micropatterns are through the thickness square holes of length (L) separated by struts with 10 &#956;m widths. Five different micropatterns (i.e. through the thickness holes) were produced with holes dimension of L = 5, 10, 15, 20 or 25 &#956;m. Scanning electron microscope (SEM, FEI-Nova NanoSEM) images of each pattern are provided in Fig. <ref type="figure">2b</ref>-f with the insets presenting a higher magnification hole image. The smaller sized 5 and 10 &#956;m features approach circular geometries rather than the intended square design. These aberrations are attributed to the photolithography limits and do not negatively impact the results presented.</p><p>The film properties were characterized using a variety of tools. The surface roughness was evaluated using Atomic Force Microscope (AFM, Bruker-Dimension Icon) while a 3-dimensional topography image (1 &#956;m &#215; 1 &#956;m) was constructed with Nanoscope software. Electron dispersive spectrometry (EDS) and differential scanning calorimeter (Simadzu DSC-50) were used to evaluate atomic composition and transformation temperatures, respectively.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.2">Endothelial cell culture and experimental design</head><p>The primary HAECs morphology tests were conducted in a 12 well plate. Each Nitinol patterned film was secured with a polydimethysiloxane (PDMS) holder as shown in Fig. <ref type="figure">3a</ref>. The holder consists of two PDMS annular disks with an outer diameter of 1.9 cm and inner diameter of 0.5 cm. The PDMS annular disks clamp the micropatterned Nitinol thin film using four Nitinol threads of diameter 0.427 mm. The holder suspends the micropatterned Nitinol thin film above the well's bottom as shown in Fig. <ref type="figure">3b</ref>. Prior to testing, each holder and Nitinol film were washed three times with 70% ethanol, rinsed twice with DI water, followed by sterilization with UV radiation for 20 min. Autoclave sterilization was avoided because the films already went through high temperature crystallization in addition to UV radiation.</p><p>The HAECs were acquired from a vendor (American Type Culture Collection) and cultured at 37 &#176;C in 5% CO 2 in vascular cell basal medium supplemented with endothelial cell growth kit -VEGF (Lonza, 1% antibiotic-antimycotic (Gibco, USA). Cell culture media were changed every three days and HAECs were subcultured when they were 80% confluence using trypsin-EDTA (Lonza, NJ, USA) until passage 7. On passage 7, 3 &#215; 10 4 HAECs were seeded onto the Nitinol patterned thin film held within the 12 well plate by the PDMS holder. Following the second day, the Nitinol films with holders were moved to a new 12 wells plate. This was done to exclude HAECs adhering to the PDMS holder from any non-adherent cells, HAECs were subsequently cultured for 30 days.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.3">Cell preparation, image acquisitions and analysis</head><p>Figure <ref type="figure">3b</ref> illustrates HAECs growth on the Nitinol thin film with green and blue colors representing the cell actin and nucleus, respectively, following day 30. The micropatterned thin film were removed from the holder and HAECs were fixed with 4% methanol free paraformaldehyde solution (Thermo Scientific, USA) for 15 min and permeated with 0.1% Trition X-100 (Thermo Scientific, USA) for 20 min. Cell nucleus and actin filament were stained with Hoechst 33342 and Alexa Flour-488 (Molecular Probe, USA) for 20 min prior to fluorescence imaging. Micropatterned thin films were positioned between two glass slides to ensure the films remained stable and in plane throughout the imaging process. Fluorescence images were acquired using an inverted microscope EVO FL Cell Imaging System. Nucleus packing density, size, and aspect ratio were quantified using captured images. Blue fluorescence images were processed using color threshold to quantify nucleus size and aspect ratio. Both operations were performed using NIH ImageJ software. <ref type="bibr">(Schneider et al. 2012)</ref> The cell packing densities were calculated by counting the number of nuclei/image using an area of 0.8 mm 2 .</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.4">Statistical analysis</head><p>Results are expressed as mean &#177; standard error. Three films were tested for each hole size. All data were analyzed using one-way analysis of variance (ANOVAs) with P &lt; 0.01 considered statistical significant. A post-hoc Welch's t-test was performed to compare films with holes against the continuous films without.  endothermic reaction is 13.94 J/g. The martensitic/austenite start/finish temperatures were identified using the intersection of the heat transfer slopes. For this film, the austenite start and finish temperatures are 29.02 &#176;C and 38.56 &#176;C, while martensitic start and finish temperatures are -13.02 &#176;C and -26.39 &#176;C, respectively. For all tests conducted in this study, the material is fully in the austenite phase because martensitic start temperature is below room temperature (-26 &#176;C). Thus, the material remains in the austenite phase following fabrication and throughout the experiment. Although not included, XRD result with a peak corresponding to the B2 phase also confirms that the film is in the austenitic phase.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3">Results and discussions</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.1">Evaluation of micropatterned thin films nitinol</head><p>The film's surface roughness was evaluated with atomic force microscopy. Figure <ref type="figure">4b</ref> shows a 3-dimensional topography image (1 &#956;m &#215; 1 &#956;m). Nitinol thin film's root mean square (RMS) surface roughness of ~6.0 nm is substantially smaller than the roughness of current prosthesis material ePTFE, which has RMS &gt;100 nm <ref type="bibr">(Venault et al. 2013;</ref><ref type="bibr">Burkarter et al. 2007</ref>). One previous study suggested that nanometer smooth surface roughness improves cell adhesion and spreading when compared to micron scale surface roughness <ref type="bibr">(Ponsonnet et al. 2003)</ref>. Furthermore, Lu et al. in 2012 suggested surface roughness below 1.0 nm is unfavorable for cells adhesion compared to 1-12 nm surface roughness. Increased surface roughness has also been suggested to inhibit endothelial cell nitric oxide production <ref type="bibr">(Yeh et al. 2006)</ref>. Regarding of thrombogenic characteristics, Nitinol thin films with surface roughness between 1 and 10 nm prevent platelet adhesion compared to the ultra smooth (&lt;1 nm) and larger submicron titanium oxide surfaces <ref type="bibr">(Levi et al. 2008;</ref><ref type="bibr">Lu et al. 2012</ref>). In addition, multiple studies have shown electropolishing procedure that decreases Nitinol stent surface roughness can also decreases in vivo blood product adhesion <ref type="bibr">(Tepe et al. 2002)</ref>. These previous results suggest the films used in the present study (i.e. ~6.0 nm roughness) provide a suitable implant surface.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.2">HAEC monolayer morphology on micropatterned Nitinol thin films</head><p>Figure <ref type="figure">5a</ref>-f provides cell images taken from the fluorescence microscope on day 30 for the films with six different hole sizes. The HAEC nuclei and actin filaments display three distinct cell layers depending on the hole sizes. For the continuous film and 5 &#956;m holes, Fig. <ref type="figure">5a</ref> and<ref type="figure">b</ref>, the endothelial cells are randomly arranged with some cell spreading. This is similar to the HAECs grown on standard tissue culture plates. Although the HAECs may appear to be larger on the 5 &#956;m film than solid film, their difference in size is not statistically significant. For the 10, 15 and 20 &#956;m hole sizes (Fig. <ref type="figure">5c,</ref><ref type="figure">d,</ref><ref type="figure">e</ref>), the images show a smooth cell monolayer with the cell nuclei centralized around the film's holes. Specifically, the blue fluorescence nuclei appear predominately within the holes and arrange themselves in a grid like pattern, which is quite different than the random arrangement shown in Fig. <ref type="figure">5a</ref> and<ref type="figure">b</ref>. The cells on these 10, 15, 20 &#956;m holes appear to be smaller compared to the continuous film and 5 &#956;m holes. Finally, for the 25 &#956;m holes (Fig. <ref type="figure">5f</ref>), a continuous smooth cell monolayer is absent compared to the five other cases. Instead, the HAECs tend to encapsulate the struts while leaving the holes void of any cellular material. These results suggest the critical bridging length preventing cells proliferation and migration must be less than 25 &#956;m but larger than 20 &#956;m.</p><p>To better understand the effect of holes on nuclei morphology and placement, blue fluorescence images were separated from Fig. <ref type="figure">5</ref> and presented in Fig. <ref type="figure">6a-f</ref>. These images reflect the three distinct cell monolayers described in the preceding paragraph and show a distinct difference in their nuclei organization and morphology. For the continuous film and the film with 5 &#956;m holes in Fig. <ref type="figure">6a</ref> &amp; b, the nuclei are randomly placed in the cell monolayers but retain an elliptical shape. For the film with 10, 15, 20 &#956;m holes, shown in Fig. <ref type="figure">6c-e</ref>, nuclei are arranged in an organized fashion reflecting the nuclei placement within the film's holes producing a grid-like distribution. However, film with 20 &#956;m holes occasionally exhibit distorted nuclei arrangement against the one observed in films with 10 and 15 &#956;m holes. The film with 20 &#956;m holes also exhibits constrained two nuclei within a single hole suggesting 20 &#956;m holes are approaching the critical dimension. For the largest hole dimension (25 &#956;m) shown in Fig. <ref type="figure">6f</ref>, the nuclei typically appear as a distorted groups of two nuclei. Furthermore, all nuclei are constrained along the hole's edge rather than within a hole. These images continue to support the idea that the critical dimension is in between 20 and 25 &#956;m.</p><p>Figure <ref type="figure">6g</ref> shows cell-packing density presented in nuclei per square cm as a function of hole size was determined using ImageJ and fluorescence intensity filter. The results show a bell shaped curve with peak cell packing density (~75 nuclei/ cm 2 ) arising in the 15 &#956;m hole films. The smallest cell packing density (~15 nuclei/cm 2 ) is found in both continuous film and the film with 5 &#956;m holes. The films with larger holes contain higher cell packing density. The relatively large cell packing density for the 25 &#956;m hole is believed to be an anomaly due to close packing of multiple nuclei around the struts. In addition, absence of a continuous monolayer on these films also misleads the cell density measurements. Figure <ref type="figure">6h</ref> and<ref type="figure">i</ref> show the cell nuclei aspect ratio and nucleus size for cells on all the films with the exception of 25 &#956;m hole films, due to non-availability of nuclei monolayer, respectively. Figure <ref type="figure">6h</ref> shows the smallest nuclei aspect ratio, representing elliptical shapes, for the cells on continuous films (0.62) and on films with 5 &#956;m holes (0.64). The highest nuclei aspect ratio (0.74) is found for the cells on the films with 10 &#956;m size holes, representing a nearly circular shape. Similarly, the cells on the films with 15 and 20 &#956;m holes are also exhibit a nearly circular shape. Figure <ref type="figure">6i</ref> shows the largest nucleus size are on the continuous films and the film with 5 &#956;m holes. This nucleus size decreases as the size of the holes increase, specifically from 240 square microns for the 5 &#956;m size holes to ~96 square microns for the 15 &#956;m size holes, as it represents a 2.5 size reduction. The increase in the nuclei size from 15 &#956;m to 20 &#956;m holes is attributed to a relief of mechanical constraints as the hole size increases. Here, cell nuclei aspect ratio correlates well with cell packing density on 15 &#956;m holes and nuclei size correlates inversely with cell packing density on 15 &#956;m as well.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.3">Impact of cell micropatterning on cell behavior and morphology</head><p>It has been shown that micropatterning generates complex interactions with biological processes including focal adhesion complex, proliferation and morphological behaviors <ref type="bibr">(Raghavan and Chen 2004;</ref><ref type="bibr">Choi et al. 2010)</ref>. While various groups have performed studies on the contact area and micropatterned holes separately, only a handful of studies address their synergistic effect on thin film with different through the thickness holes <ref type="bibr">(Shen et al. 2009;</ref><ref type="bibr">Lee et al. 2014)</ref>. Our fabrication method precisely controls the micropattern holes with various dimensions separated by a 10 &#956;m strut. The results show that the nucleus are predominantly located within the holes for 10-20 &#956;m hole films, whereas cell nucleus are randomly arranged in films with either smaller holes or continuous films. The nuclei centered in the holes promote nuclei compartmentalization for the 10-20 &#956;m holes enabling HAEC focal adhesion complex on the surrounding struts enclosing the nucleus with supporting actin caps <ref type="bibr">(Kim et al. 2012</ref>). However, this compartmentalization reduces as holes size increases to 20 &#956;m and above. In the cases of 20 &#956;m hole films, the majority of the nuclei are organized in a grid like structure, as in 15 &#956;m hole film, but with distorted nucleus and/or two nuclei located in area/holes.</p><p>The cell nuclei compartmentalization observed in the 10-20 &#956;m size holes also generate more spherical nuclei shapes as compared to the ellipsoid shape seen in the continuous film. Although it is unclear whether these changes are actual shape changes or a switch in the nucleus orientation, the decrease in nucleui size and aspect ratio found here are in agreement with the cytoplasmic and nucleus deformation seen in <ref type="bibr">Davidson et al. (2009)</ref>. This result suggests the mechanotransduction of cell nucleus in 10-20 &#956;m size holes are using physical force to activate biological responses <ref type="bibr">(Wang et al. 2009</ref>). Therefore, it is plausible that HAEC growing on the physical constraints imposed by micropattern films behave differently from conventional HAEC growing on a continuous film. The transfer of mechanical signals from cell surface to the nucleus through cytoskeleton has shown to provide negative proliferation effect when the nucleus is condensed <ref type="bibr">(Versaevel et al. 2012</ref>). However, mechanical signals in the form of shear flow with minor changes in the nucleus shape also improve cell proliferation <ref type="bibr">(White and Gray 2007)</ref>. Thus, HAEC nucleus deformation observed in this study may result in a biological response that is related to the proliferation rate. In addition to the physical changes of the nucleus, accurate control of the external matrix could also guide the direction of mitosis and possibly shorten its division time by artificially triggering the abscission step <ref type="bibr">(Th&#233;ry et al. 2005;</ref><ref type="bibr">Lafaurie-Janvore et al. 2013)</ref>. It is speculated that HAEC seeded on the strut results in uniaxial mechanical forces caused by the holes and promotes mitosis process for cell division.</p><p>In addition to the potential metabolic effect, we discovered that HAEC could grow across micropattern holes smaller than 25 &#956;m. Since previous researcher have shown that size of HAEC are limited to 20 &#956;m, this result can be explained on the basis that the 25 &#956;m gap is too large for the cells to form anchoring focal adhesion complexes with the surrounding struts <ref type="bibr">(Garipcan et al. 2011;</ref><ref type="bibr">Cheng et al. 2009)</ref>. As a result of the large physical gap, the HAEC has insufficient traction force to form a smooth monolayer above the holes. This critical bridging length could be essential for future embedded vascular devices that required full re-endothelialization to form a physical barrier for the lipoproteins in various diseases such as atherosclerosis.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="4">Conclusions</head><p>Nitinol Films with five different size square holes, 5, 10, 15, 20 and 25 &#956;m, were fabricated. HAECs were seeded onto the thin films and allowed to grow for 30 days before cell morphologies were imaged and analyzed. Result shows that the packing density in films with 15 &#956;m holes is almost 4 times larger than that of the continuous films. However, the nuclei size in the 15 &#956;m holes was half when compared to continuous film. The nuclei aspect ratio in 10-20 &#956;m hole films produce more circular shape when compared to continuous film and films with 5 &#956;m holes. Furthermore, the films with 10-20 &#956;m holes display a unique engineered grid like cell distribution with nucleus placement within the hole. The 25 &#956;m holes also were not able to completely bridge the hole and form a smooth monolayer.</p></div><note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_0"><p>Biomed Microdevices (2018) 20:25   </p></note>