- NSF-PAR ID:
- 10066783
- Publisher / Repository:
- American Chemical Society
- Date Published:
- Journal Name:
- ACS Applied Bio Materials
- Volume:
- 1
- Issue:
- 1
- ISSN:
- 2576-6422
- Page Range / eLocation ID:
- p. 79-89
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
This study introduces a technique called cine magnetic resonance fingerprinting (cine‐MRF) for simultaneous T1, T2and ejection fraction (EF) quantification. Data acquired with a free‐running MRF sequence are retrospectively sorted into different cardiac phases using an external electrocardiogram (ECG) signal. A low‐rank reconstruction with a finite difference sparsity constraint along the cardiac motion dimension yields images resolved by cardiac phase. To improve SNR and precision in the parameter maps, these images are nonrigidly registered to the same phase and matched to a dictionary to generate T1and T2maps. Cine images for computing left ventricular volumes and EF are also derived from the same data. Cine‐MRF was tested in simulations using a numerical relaxation phantom. Phantom and in vivo scans of 19 subjects were performed at 3 T during a 10.9 seconds breath‐hold with an in‐plane resolution of 1.6 x 1.6 mm2and 24 cardiac phases. Left ventricular EF values obtained with cine‐MRF agreed with the conventional cine images (mean bias −1.0%). Average myocardial T1times in diastole/systole were 1398/1391 ms with cine‐MRF, 1394/1378 ms with ECG‐triggered cardiac MRF (cMRF) and 1234/1212 ms with MOLLI; and T2values were 30.7/30.3 ms with cine‐MRF, 32.6/32.9 ms with ECG‐triggered cMRF and 37.6/41.0 ms with T2‐prepared FLASH. Cine‐MRF and ECG‐triggered cMRF relaxation times were in good agreement. Cine‐MRF T1values were significantly longer than MOLLI, and cine‐MRF T2values were significantly shorter than T2‐prepared FLASH. In summary, cine‐MRF can potentially streamline cardiac MRI exams by combining left ventricle functional assessment and T1‐T2mapping into one time‐efficient acquisition.
-
Bi 3 MoM T O 9 (BMoM T O; M T , transition metals of Mn, Fe, Co and Ni) thin films with a layered supercell structure have been deposited on LaAlO 3 (001) substrates by pulsed laser deposition. Microstructural analysis suggests that pillar-like domains with higher transition metal concentration ( e.g. , Mn, Fe, Co and Ni) are embedded in the Mo-rich matrix with layered supercell structures. The layered supercell structure of the BMoM T O thin films accounts for the anisotropic multifunctionalities such as the magnetic easy axis along the in-plane direction, and the anisotropic optical properties. Ferroelectricity and ferromagnetism have been demonstrated in the thin films at room temperature, which confirms the multiferroic nature of the system. By varying the transition metal M T in the film, the band gaps of the BMoM T O films can be effectively tuned from 2.44 eV to 2.82 eV, while the out-of-plane dielectric constant of the thin films also varies. The newly discovered layered nanocomposite systems present their potential in ferroelectrics, multiferroics and non-linear optics.more » « less
-
Purpose This work aims to develop an approach for simultaneous water–fat separation and myocardial T1and T2quantification based on the cardiac MR fingerprinting (cMRF) framework with rosette trajectories at 3T and 1.5T.
Methods Two 15‐heartbeat cMRF sequences with different rosette trajectories designed for water–fat separation at 3T and 1.5T were implemented. Water T1and T2maps, water image, and fat image were generated with B0inhomogeneity correction using a B0map derived from the cMRF data themselves. The proposed water–fat separation rosette cMRF approach was validated in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and water/oil phantoms. It was also applied for myocardial tissue mapping of healthy subjects at both 3T and 1.5T.
Results Water T1and T2values measured using rosette cMRF in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom agreed well with the reference values. In the water/oil phantom, oil was well suppressed in the water images and vice versa. Rosette cMRF yielded comparable T1but 2~3 ms higher T2values in the myocardium of healthy subjects than the original spiral cMRF method. Epicardial fat deposition was also clearly shown in the fat images.
Conclusion Rosette cMRF provides fat images along with myocardial T1and T2maps with significant fat suppression. This technique may improve visualization of the anatomical structure of the heart by separating water and fat and could provide value in diagnosing cardiac diseases associated with fibrofatty infiltration or epicardial fat accumulation. It also paves the way toward comprehensive myocardial tissue characterization in a single scan.