skip to main content


Title: Local direction change of surface gliding microtubules
Abstract

In vitro gliding assay, microtubule translocation by kinesin motor proteins on a surface, has been used as an engineering tool in analyte detection, molecular cargo transport, and other applications. Although controlling the moving direction is often necessary to realize these applications, current direction control methods focus largely on lithographic microfabrication of tracks or external fields on the microtubules. These methods are effective, but are relatively complicated. In addition, they cannot target particular microtubules without affecting others. In this study, we propose a facile approach that can make local direction changes for selected microtubules using a polystyrene particle as a circular motion center and a DNA double helix with streptavidin as a capture arm. The DNA arm captures a microtubule in the close proximity of the immobilized particle via biotin–streptavidin interaction and changes the moving direction ~10° on average. In contrast, no significant direction changes are observed other than random variations with streptavidin‐less DNA arms (normal distribution centered at 0°), similar to regular motility assay. The particle‐assisted local direction change scheme is compared with a flow field‐based ensemble method. The combination of flow and kinesin interactions with each microtubule exerts a force to change the direction, ultimately aligning it to the flow field, regardless of its initial direction. A simple model based on the force balance predicts the time needed for such an alignment. Overall, the particle‐based local scheme is distinct and different from ensemble methods such as crossflow that changes directions of all microtubules in the field, thus offering unique utility in engineering applications.

 
more » « less
Award ID(s):
1710344
NSF-PAR ID:
10085008
Author(s) / Creator(s):
 ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Biotechnology and Bioengineering
Volume:
116
Issue:
5
ISSN:
0006-3592
Page Range / eLocation ID:
p. 1128-1138
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    Microtubules regulate cell polarity and migration via local activation of focal adhesion turnover, but the mechanism of this process is insufficiently understood. Molecular complexes containing KANK family proteins connect microtubules with talin, the major component of focal adhesions. Here, local optogenetic activation of KANK1-mediated microtubule/talin linkage promoted microtubule targeting to an individual focal adhesion and subsequent withdrawal, resulting in focal adhesion centripetal sliding and rapid disassembly. This sliding is preceded by a local increase of traction force due to accumulation of myosin-II and actin in the proximity of the focal adhesion. Knockdown of the Rho activator GEF-H1 prevented development of traction force and abolished sliding and disassembly of focal adhesions upon KANK1 activation. Other players participating in microtubule-driven, KANK-dependent focal adhesion disassembly include kinases ROCK, PAK, and FAK, as well as microtubules/focal adhesion-associated proteins kinesin-1, APC, and αTAT. Based on these data, we develop a mathematical model for a microtubule-driven focal adhesion disruption involving local GEF-H1/RhoA/ROCK-dependent activation of contractility, which is consistent with experimental data.

     
    more » « less
  2. Cytoskeletal active nematics exhibit striking nonequilibrium dynamics that are powered by energy-consuming molecular motors. To gain insight into the structure and mechanics of these materials, we design programmable clusters in which kinesin motors are linked by a double-stranded DNA linker. The efficiency by which DNA-based clusters power active nematics depends on both the stepping dynamics of the kinesin motors and the chemical structure of the polymeric linker. Fluorescence anisotropy measurements reveal that the motor clusters, like filamentous microtubules, exhibit local nematic order. The properties of the DNA linker enable the design of force-sensing clusters. When the load across the linker exceeds a critical threshold, the clusters fall apart, ceasing to generate active stresses and slowing the system dynamics. Fluorescence readout reveals the fraction of bound clusters that generate interfilament sliding. In turn, this yields the average load experienced by the kinesin motors as they step along the microtubules. DNA-motor clusters provide a foundation for understanding the molecular mechanism by which nanoscale molecular motors collectively generate mesoscopic active stresses, which in turn power macroscale nonequilibrium dynamics of active nematics.

     
    more » « less
  3. Abstract

    Microtubules, cylindrical assemblies of tubulin proteins with a 25 nm diameter and micrometer lengths, are a central part of the cytoskeleton and also serve as building blocks for nanobiodevices. Microtubule breaking can result from the activity of severing enzymes and mechanical stress. Breaking can lead to a loss of structural integrity, or an increase in the numbers of microtubules. We observed breaking of taxol-stabilized microtubules in a gliding motility assay where microtubules are propelled by surface-adhered kinesin-1 motor proteins. We find that over 95% of all breaking events are associated with the strong bending following pinning events (where the leading tip of the microtubule becomes stuck). Furthermore, the breaking rate increased exponentially with increasing curvature. These observations are explained by a model accounting for the complex mechanochemistry of a microtubule. The presence of severing enzymes is not required to observe breaking at rates comparable to those measured previously in cells.

     
    more » « less
  4. Dynamic lane formation and long-range active nematic alignment are reported using a geometry in which kinesin motors are directly coupled to a lipid bilayer, allowing for in-plane motor diffusion during microtubule gliding. We use fluorescence microscopy to image protein distributions in and below the dense two-dimensional microtubule layer, revealing evidence of diffusion-enabled kinesin restructuring within the fluid membrane substrate as microtubules collectively glide above. We find that the lipid membrane acts to promote filament–filament alignment within the gliding layer, enhancing the formation of a globally aligned active nematic state. We also report the emergence of an intermediate, locally ordered state in which apolar dynamic lanes of nematically aligned microtubules migrate across the substrate. To understand this emergent behavior, we implement a continuum model obtained from coarse graining a collection of self-propelled rods, with propulsion set by the local motor kinetics. Tuning the microtubule and kinesin concentrations as well as active propulsion in these simulations reveals that increasing motor activity promotes dynamic nematic lane formation. Simulations and experiments show that, following fluid bilayer substrate mediated spatial motor restructuring, the total motor concentration becomes enriched below the microtubule lanes that they drive, with the feedback leading to more dynamic lanes. Our results have implications for membrane-coupled active nematics in vivo as well as for engineering dynamic and reconfigurable materials where the structural elements and power sources can dynamically colocalize, enabling efficient mechanical work. 
    more » « less
  5. Active fluid, composed of kinesin-driven extensile bundles of microtubules, consumes ATP locally to create a self-mixing flow. Mean speed of microtubule-kinesin active fluid was shown to be tunable by varying its components’ concentrations. Such tunability demonstrated the controllability of active fluid with uniform activity. However, how active fluid self-organizes when its activity is non-uniform remains poorly understood. Here, we characterized active fluid behavior and its associated mixing performance in an activity gradient. The activity gradient was created by imposing a temperature gradient because our previous work showed that microtubule-kinesin active fluid exhibited an Arrhenius response to temperature: Increasing temperature sped up active fluid flow, and thus, along a temperature gradient, active fluid flowed faster on one side and slower on the other, forming an activity gradient. We characterized how such a gradient influenced the mixing performance of active fluid in terms of mixing efficiency, stretching rate, and mean squared displacement, comparing with an activity-uniform sample. Our work suggests that applying an activity gradient can serve as a new in-situ method for controlling self-organization and mixing performance of microtubule-kinesin active fluid. 
    more » « less