<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Sonocrystallization of conjugated polymers with ultrasound fields</title></titleStmt>
			<publicationStmt>
				<publisher></publisher>
				<date>01/01/2018</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10092462</idno>
					<idno type="doi">10.1039/C8SM00905H</idno>
					<title level='j'>Soft Matter</title>
<idno>1744-683X</idno>
<biblScope unit="volume">14</biblScope>
<biblScope unit="issue">24</biblScope>					

					<author>Yuyin Xi</author><author>David S. Li</author><author>Greg M. Newbloom</author><author>Wesley K. Tatum</author><author>Matthew O’Donnell</author><author>Christine K. Luscombe</author><author>Lilo D. Pozzo</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[Ultrasound acoustic waves are demonstrated to assemble poly-3-hexylthiophene (P3HT) chains into nanofibers after they are fully dissolved in what are commonly considered to be ‘good’ solvents. In the absence of ultrasound, the polymer remains fully dissolved and does not self-assemble for weeks. UV-vis spectroscopy, ultra-small angle X-ray scattering (USAXS) and small angle neutron scattering (SANS) are used to characterize the induced assembly process and to quantify the fraction of polymer that forms nanofibers. It is determined that the solvent type, insonation time, and aging periods are all important factors affecting the structure and final concentration of fibers. The effect of changing polymer regio-regularity, alkyl chain length, and side chain to thiophene ratio are also explored. High intensity focused ultrasound (HIFU) fields of variable intensity are utilized to reveal the physical mechanisms leading to nanofiber formation, which is strongly correlated to cavitation events in the solvent. This              in situ              HIFU cell, which is designed for simultaneous scattering analysis, is also used to probe for structural changes occurring over multiple length scales using USAXS and SANS. The proposed acoustic assembly mechanism suggests that, even when dispersed in ‘good’ solvents such as bromobenzene, dichlorobenzene and chloroform, P3HT chains are still not in a thermodynamically stable state. Instead, they are stabilized by local energy barriers that slow down and effectively prevent crystallization. Ultrasound fields are found to provide enough mechanical energy to overcome these barriers, triggering the formation of small crystalline nuclei that subsequently seed the growth of larger nanofibers.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Introduction</head><p>Conjugated polymers (CPs) have been extensively pursued as candidate materials for use in organic photovoltaics (OPVs), organic light emitting diodes (OLEDs), and organic field-effect transistors (OFETs). <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref> In addition to their (opto)electronic properties, properties such as flexibility, bio-compatibility, and highly tunable molecular design make them promising materials for novel sensors and bioelectronic devices. <ref type="bibr">4,</ref><ref type="bibr">5</ref> Unfortunately, limited electrical conductivity is still a major hindrance for the effective application of CPs in many applications. Frequently, amorphous polymer structures lead to inefficient inter-chain charge hopping that limits charge transport. This is often corrected by initiating the formation of ordered polymer phases that are driven by stacking p-orbitals orthogonal to the polymer backbone. The resulting formation of large crystalline structures facilitates inter-chain charge propagation, which enables transport over much longer distances and improves charge-carrier mobility by several orders of magnitude. <ref type="bibr">6</ref> Recently, much work has also been dedicated to further increasing conductivity by engineering polymer structures with external forces, including capillary, <ref type="bibr">7</ref> shear, <ref type="bibr">8</ref> gravitational, <ref type="bibr">9</ref> and electrostatic forces. <ref type="bibr">10</ref> In this work, the use of acoustic fields at ultrasound frequencies (420 kHz) is investigated as an effective method to assemble polymer chains into fibers with long-range order.</p><p>In colloid and polymer science, ultrasound is most frequently used in a destructive way to mechanically break up aggregates, disperse particles, emulsify oils, and even to break up whole cells in a process known as sonofragmentation. <ref type="bibr">[11]</ref><ref type="bibr">[12]</ref><ref type="bibr">[13]</ref><ref type="bibr">[14]</ref> However, and often counter-intuitively, in some cases ultrasound is also used to assemble molecules into highly ordered structures in a process known as sonocrystallization, where the wavelength of the acoustic wave (Bcm) is several orders larger than the size of the molecules. Successful demonstrations of sonocrystallization usually involve small molecules, such as adipic acid, <ref type="bibr">15</ref> sulfamerazine, <ref type="bibr">16</ref> and glucose. <ref type="bibr">17</ref> In the above systems, ultrasound is typically applied to solutions with supersaturation to induce crystallization. Although the mechanism of crystallization under ultrasound is still ambiguous, it has been reported that ultrasound can effectively shorten the induction time (i.e. duration between achievement of supersaturation and appearance of detectable crystals). Recently, pioneering work provided evidence of the possibilities of inducing sonocrystallization on macromolecules including proteins <ref type="bibr">[18]</ref><ref type="bibr">[19]</ref><ref type="bibr">[20]</ref> and conjugated polymers. <ref type="bibr">[21]</ref><ref type="bibr">[22]</ref><ref type="bibr">[23]</ref> It was reported that poly(3-hexylthiophene) (P3HT) polymers chains can assemble into nanofibers that are micrometers long under ultrasound in chloroform or toluene. <ref type="bibr">[21]</ref><ref type="bibr">[22]</ref><ref type="bibr">[23]</ref> Early investigations of P3HT sonication in 'good' solvents (i.e. chlorobenzene and 1,2-dichlorobenzene) did not observe nanofibers formation, but they revealed that the solution's specific viscosity decreased, which was hypothesized to correlate to a change in chain conformation. <ref type="bibr">23</ref> The higher the concentration (namely supersaturation), the more obvious the changes are. Furthermore, the formation of nanofibers was demonstrated to enhance the charge carrier's mobility by up to one order of magnitude due to more efficient inter-chain transport. <ref type="bibr">21</ref> On the other hand, spontaneous nanofiber formation in conjugated polymers is also routinely achieved by tuning solvent quality or changing temperature in the absence of any external fields. <ref type="bibr">[24]</ref><ref type="bibr">[25]</ref><ref type="bibr">[26]</ref><ref type="bibr">[27]</ref> Therefore, there are still important questions remaining on the specific effect of ultrasound on polymer chains and how this relates to spontaneous selfassembly that may occur due to variations in solubility in the absence of ultrasound.</p><p>We hypothesize that the role of ultrasound in sonocrystallization of conjugated polymers, from a thermodynamics point of view, follows the energy diagram shown in Fig. <ref type="figure">1</ref>. For ideal good solvents, the dissolved state is supposed to be a global energy minimum within the energy landscape, which means once it is dissolved, it should stay in the thermodynamically favored dissolution state without assembly. However, in reality polymer chains that appear to be fully dissolved in 'good' solvents, are instead confined to a local energy minimum created by an energy barrier. This prevents them from achieving crystallization, which is a more energetically favorable state, in a reasonable time frame. As the solvent quality increases, the energy necessary to cross this stabilizing barrier is larger. This is analogous to the kinetic stabilization of colloidal particles that can remain suspended for long periods of time due to electrostatic repulsion. Although these particles may appear to be in an energetically stable state, the global energy minima is in the aggregated state, but a significant energy barrier prevents them from achieving this state in a reasonable time frame.</p><p>In sonocrystallization, ultrasound provides enough energy to allow molecules and polymers to overcome the stabilizing barrier resulting in the formation of crystalline nuclei that facilitate further crystallization. Still, a persistent question is by what mechanism is ultrasound triggering the crystallization process. We hypothesize that cavitation induces sonocrystallization by modifying the conformation of polymer chains to facilitate the formation of crystal nuclei for continued growth. In this process, the formation of cavitation events is strongly dependent on the applied acoustic field frequency and pressure. In order to quantitatively relate the acoustic field to the nucleation process, to shed light on the mechanism of conjugated polymer sonocrystallization, it is essential to use well-characterized acoustic fields to probe the system.</p><p>To accurately describe an acoustic wave, its pressure and frequency are typically utilized. <ref type="bibr">28</ref> When the pressure of the acoustic wave is lower than ambient pressure (i.e. in the so called negative pressure phase), it exerts a tension on the surrounding liquid medium that could induce the formation of a cavity if its magnitude is above a certain threshold. <ref type="bibr">29</ref> Cavitation is defined by Neppiras as the creation of new surface or cavity within the liquid. <ref type="bibr">30</ref> Cavitation thresholds depend on several factors including the frequency of the acoustic wave, the pressure amplitude, the surface tension, temperature and boiling point. At higher frequencies, larger pressure amplitudes are required to induce cavitation. <ref type="bibr">31,</ref><ref type="bibr">32</ref> The formation of a cavity favors growth under acoustic waves because of rectified diffusion. During expansion (negative pressure), liquid molecules diffuse into vapor bubbles to form a larger gaseous phase. In contrast, vapors condense into the liquid in response to the compression force that is induced at the positive pressure stage of the wave. <ref type="bibr">31</ref> Importantly, the transport into and out of the cavity is not balanced because the bubble surface area during the expansion stage is much larger than that during compression. This results in the growth of the cavity or bubble under continued insonation. When a bubble grows to a critical size, it will eventually resonate with the acoustic wave and this will lead to an abrupt collapse producing localized extreme conditions (i.e. temperature up to 5000 K and pressure up to 1000 atm) and ejecting high-speed jets (100-400 m s &#192;1 ) that mechanically act on the surrounding fluid and container. <ref type="bibr">[33]</ref><ref type="bibr">[34]</ref><ref type="bibr">[35]</ref> Subsequently, rapid cooling (10 7 -10 10 Ks &#192;1 ) occurs and shock waves are generated. <ref type="bibr">36</ref> The extreme effects of thousands of these local cavitation events are largely responsible for the cleaning action and sample manipulation (e.g. emulsification) that makes ultrasound a valuable tool in the laboratory.</p><p>In this work, we provide a detailed mechanistic and structural analysis of the processes involved in the formation of organized crystalline domains (i.e. nanofibers) during the ultrasound activation of conjugated polymers dissolved in what are considered to be 'good' solvents for these materials. We use carefully characterized acoustic waves and perform cavitation and structural analyses to properly inform the mechanisms of fiber formation.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Experimental</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Materials</head><p>All chemicals were used as received. Poly(3-alkylthiophene) (P3AT), including regio-regular, regio-random poly(3-hexylthiophene) (P3HT), and poly(3-dodecylthiophene) (P3DDT) were purchased from Rieke Metals (Lincoln, NE, USA). Poly(3,3 000didodecylquarterthiophene) (PQT-12) was purchased from Solaris Chem (Montreal, Quebec, Canada). Two lots of regioregular P3HT with the same degree of polymerization, dispersity, and regioregularity were utilized: RMI-001E, lot# PTL14-85 and lot# BS 23-49 (M w = 69k, &#208; = 2.3, and regioregularity = 96%). Lot#14-85 was used to collect most of the data with the exception of samples analyzed with in situ neutron scattering during ultrasound. The molecular weights and lot numbers of other conjugated polymers are summarized in Table <ref type="table">S1</ref> in ESI. &#8224; Hydrogenated solvents: chloroform (99.9%) and chlorobenzene were purchased from Fisher Scientific (Waltham, MA, USA). 1,2-Dichlorobenzene (99%) were purchased from Sigma-Aldrich (St. Louis, MO, USA). Deuterated solvents: d-chloroform (D, 99.8%), d 5 -chlorobenzene (D, 99%), d 4 -1,2-dichlorobenzene (D, 99%), and d 5 -bromobenzene (D, 99%) were purchased from Cambridge Isotope Laboratories (Cambridge, MA, USA).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Transmission electron microscopy</head><p>An FEI (Tecnai G2 F20, FEI company, Hillsboro, OR, USA) transmission electron microscope (TEM) was used in scanning mode to take images of conjugated polymer samples. Before analysis, solutions were diluted by 20 times (chloroform) or 40 times (dichlorobenzene) in the same solvent as that was used for sample preparation. The polymer samples were dropcast onto a pure carbon grid (200 mesh Cu, Ted Pella Inc., Redding, CA, USA) placed on top of a filter paper and dried for at least a day in air.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>UV-vis spectroscopy</head><p>A Thermo (Evolution 300, Thermo Fisher Scientific Inc., Waltham, MA, USA) UV-vis spectrometer was utilized to measure the absorbance spectra of polymer solutions between wavelength of 350 and 700 nm. A glass cuvette with a pathlength of 1 cm was used. After treatment with ultrasound, samples were diluted by B500 times to measure time-dependent absorbance after aging over several days. The spectrum of reference samples that were not exposed to ultrasound were also recorded over the same aging time for comparison. All the spectra were normalized by concentration. The concentration was determined by using the absorption peak of the same polymer solution sample after re-heating and fully re-dissolving it.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Small angle neutron scattering (SANS)</head><p>Small angle neutron scattering (SANS) experiment were conducted at NIST center for Neutron Research (NCNR) on NGB 30. Three standard detector positions were used to cover a q-range of 0.003 &#197; &#192;1 o q o 0.45 &#197; &#192;1 . Part of the scattering data was also collected in the GP-SANS instrument at Oak Ridge national laboratories with a configuration achieving a similar q-range. Standard sample cells with quartz windows and a 1 mm pathlength were used for samples that were insonated outside of the neutron beam in Branson (3510, 40 kHz, 160 W, Danbury, CT, USA) sonication bath. The SANS data was reduced by using standard Igor reduction protocols, <ref type="bibr">37</ref> and SASView software was used to fit to appropriate models. <ref type="bibr">38</ref> Ultra-small angle X-ray scattering (USAXS) Ultra-small angle X-ray scattering (USAXS) experiments were conducted at sector 9-ID-C beamline in Advanced Photon Source (APS) of Argonne National Laboratory. <ref type="bibr">39</ref> Standard configuration was used to cover the range of 0.0001 &#197; &#192;1 o q o 0.3 &#197; &#192;1 . The energy of X-ray beam was 21 keV (l =0 . 5 9 0 4&#197; ) .In situ acoustic sample environment that allows in situ scattering experiment under ultrasound is mounted along the beam path. The detailed description of the customized sample environment is described in the ultrasound insonation section below. The raw USAXS data was collected with Bonse-Hart camera and the Irena macro based on Igor Pro package was used to reduce the USAXS data. <ref type="bibr">40</ref> </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Ultrasound insonation</head><p>Polymers were fully dissolved in good solvents at elevated temperatures (B60 1C for chloroform samples and above 80 1C for those in 1,2-dichlorobenzne) until a homogeneous orange solution was formed. The solutions were then allowed to cool down to room temperature before use. These solutions were then used in sequential characterization with either ex situ or in situ application of ultrasound.</p><p>For ex situ experiment using a sonication bath, fully dissolved samples were then divided to explore different ultrasound conditions. This reduces any error that may be introduced by variations in concentration during preparations of different batches. Moreover, it ensures that aging conditions (i.e. time and temperature) for ultrasound treated and reference samples (i.e. without sonication) are the same. Data for samples in a sonication bath were collected with a Branson 5000 (40 kHz, 160 W, Danbury, CT, USA) sonication bath.</p><p>For in situ experiments, the polymer solutions were injected into a customized sample environment that allows simultaneous application of High Intensity Focused Ultrasound (HIFU). The acoustic sample environment consisted of a central sample holder, two coaxially aligned transmitting focused transducers, and one broadband receiving transducer (Fig. <ref type="figure">2</ref>). Windows were formed from 100 mm thick Kapton films for both acoustic and neutron beam transmission. Two 1.24 MHz spherically focused transducers (H-102, 68 mm diameter, 63 mm focal length, f-number 0.95, Sonic-Concepts Inc., Bothell, WA, USA) coaxially aligned to the left and right of the sample environment were used to sonicate the sample under highly controlled fields in the absence of large reflections. The transducers, which were held in a degassed water chamber that was used as a coupling medium, were able to transmit up to 7.2 MPa of peak negative acoustic pressure. The transducer chambers were designed with angled walls to minimize shadowing of the scattered neutron beam while also accommodating the focusing beam geometry of the transducers. The transducer chamber dimensions ensured that the acoustic beam focus was within the sample holder. The bottom of the sample holder held a custom wide-band polyvinylidene difluoride (PVDF) transducer (28 mm thick) with a nearly constant bandwidth sensitivity at frequencies up to 40 MHz. Medical ultrasound gel was used to facilitate acoustic contact between all transducers and the sample environment.</p><p>During SANS, the scattering volume was defined by cadmium slits to form a 1 mm by 8 mm rectangle that matched the focal volume of the HIFU transducers. For USAXS, slits were not necessary because the beam size (o1 mm) was smaller than the ultrasound focal volume. The ultrasound focal volume was approximately 1.6 mm in the radial direction and 13.2 mm in the axial direction. The beam profiles of the ultrasound transducers were obtained using a needle hydrophone (HNC-1000, Onda Corp., Sunnvale, CA, USA) while the pressure output was calibrated using a fiber optic hydrophone (FOPH 2000, RPI Acoustics, Germany).</p><p>A laptop was used to control and acquire acoustic data from the acoustic sample environment using MATLAB (Mathworks Inc., Watham, MA, USA). The transducers were driven using short N-cycle sine-wave bursts generated from a two-channel arbitrary waveform generator (4154, BK Precision) amplified by 55 dB through a power RF amplifier (A150, ENI). The transducers were activated in an alternating configuration using a custom relay circuit, to avoid sonophoresis from a single transducer (i.e. sample depletion from acoustic radiation force) or sample enrichment at acoustic standing wave antinodes (i.e. during simultaneous transducer activation). The acoustic pressure amplitude, pulse duration, pulse repetition frequency, and transducer switching frequency could be controlled using the laptop through the arbitrary function generator. In general, the acoustic sample environment was driven using peak negative pressure amplitudes ranging from 0 to 7.2 MPa, a pulse duration of 40 cycles (32.3 ms pulse length), pulse repetition frequency of 6.2 KHz, and switching between each transducer at a rate of 1 Hz. The scattered acoustic data received from the PVDF transducer, which was used for cavitation detection, was preconditioned using a preamplifier (Precision Acoustics, Dorchester, UK). The cavitation signal was a differential ultrasound signal obtained by comparing the received signal to a background measurement. A 40 ms window starting from 43 ms after the transducer was fired, which was the one-way time of flight from transducer face to its focal point, was used for cavitation analysis. When the acoustic signal captured by the PVDF transducer was above a threshold value (in this study it is 9 times above the background noise), this was categorized as a cavitation event. The cavitation probability was then simply calculated from the total number of cavitation events that were generated from a given number of incident ultrasound pulses. This value is dependent on the solvent (lower boiling point solvents cavitate more readily) and also on the properties of the acoustic pulse (e.g. pressure, frequency). The acoustic waveforms were collected by a digital oscilloscope (2190D, BK Precision) and stored on a laptop for cavitation analysis. All acoustic data was time-stamped for possible co-registration with changes observed in scattering profiles.</p><p>Since ultrasound introduces energy into the system, the temperature of samples could also change depending on the ultrasound conditions and history. To control this, all experiments were conducted at room temperature and the duty cycle (on/off ratio) of the incident ultrasound was controlled to allow for heat dissipation to keep the temperature nearly constant. For samples sonicated in a water bath, the change in temperature is negligible due to the high heat capacity of water and the large volume of the bath. Increases in temperature of up to B20 1C were observed towards the end of long experiments performed with the in situ sample environment, which does not currently have active cooling capabilities, but these effects were minimized by controlling the duty cycle. Work is currently in progress to implement active cooling and temperature control schemes into the sample environment for future experiments.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Results</head><p>Scanning transmission electron microscopy (sTEM) was used to directly visualize the structural change induced by acoustic wave after 1 day of aging time in Fig. <ref type="figure">3</ref>. Regio-regular poly (3-hexylthiophene) (RR-P3HT) was fully dissolved in commonly used good solvents: chloroform (CF) (Fig. <ref type="figure">3</ref>(a) and (b)), and 1,2-dichlorobenzene (DCB) (Fig. <ref type="figure">3(c)</ref> and<ref type="figure">(d)</ref>). Acoustic insonation was then applied by placing the polymer solution vials in a commercial sonication bath for 10 min for the sample in CF (Fig. <ref type="figure">3(a)</ref>) and 30 min for that in DCB (Fig. <ref type="figure">3(c)</ref>). Fibers are formed in both solutions after sonication. It is interesting to note that the sample prepared in CF (Fig. <ref type="figure">3(a)</ref>) showed relatively short fibril lengths (o1 mm), whereas DCB produces fibers that are tens of micrometers long (Fig. <ref type="figure">3(c)</ref>). The inset images are taken with higher magnification and the width of the nanofibers cross-sections are B30 nm. In contrast, the sample without sonication does not show fiber formation (Fig. <ref type="figure">3(b</ref>)) in CF.</p><p>In DCB, very different fibril structures with low contrast are observed for samples without ultrasound irradiation (Fig. <ref type="figure">3(d)</ref>), which also appears faintly in the background of the sonicated samples (Fig. <ref type="figure">3(c)</ref>). This effect could originate be from the slow drying process of DCB that is used for sample preparation. sTEM provides representative information on the nanofiber's shape. However, due to the limit in sTEM sample preparation procedure, it cannot determine the overall fraction of fibers formed in the polymer solution. Also, it could be possible that drying, which is required for sTEM, could also induce supersaturation and crystallization. Therefore, in situ techniques that can directly characterize the fiber formation processes in solution would be highly complementary to sTEM.</p><p>UV-vis spectroscopy was used to quantify the amount of RR-P3HT aggregates in solutions based on distinct absorption peaks of crystalline structures due to various vibrational states. <ref type="bibr">41</ref> Visually, solutions of fully dissolved polymers show a transparent orange color. In contrast, the formation of even small numbers of aggregates results in a very dark solution. Fig. <ref type="figure">S1</ref> in the ESI &#8224; shows an example of ultrasound induced color change of RR-P3HT solutions. Spectra are recorded in Fig. <ref type="figure">4</ref> as a function of aging time after sonication of polymer solutions in both CF and DCB. In Fig. <ref type="figure">4(a)</ref>, two new peaks at 566 and 618 nm start to emerge right after sonication in chloroform, which indicates formation of aggregates. The intensity of the two absorption peaks keeps increasing and they stay relatively constant after 6 h of aging. In contrast, the reference sample without acoustic treatment does not show aggregate formation even after 97 h of aging (Fig. <ref type="figure">4(b)</ref>). By switching solvent to DCB (Fig. <ref type="figure">4(c</ref>)), 10 min insonation does not result in any instantly observable change to the spectrum. Longer sonication time (30 min) induces a small peak at 607 nm for the initial spectrum after sonication (Fig. <ref type="figure">4(e)</ref>). Compared to CF, more absorption peaks emerge and more dramatic shifts in absorption peak positions are observed in DCB. Three distinct peaks at 512, 552, and 600 nm develop during this process. The major absorption peak also shows a red shift from 465 nm in the original spectra to 479 nm after 97 h of aging. Similar to samples in CF, RR-P3HT in DCB without ultrasound treatment does not exhibit any optical change due to aging (Fig. <ref type="figure">4(d)</ref>). Amorphous and aggregated peak absorption areas are used to convert the absorption spectrum to polymer aggregates fractions by considering the differences in extinction coefficient of fully dissolved polymers in those two forms. <ref type="bibr">41,</ref><ref type="bibr">42</ref> The spectra after subtraction of the dissolved polymer fraction are shown in Fig. <ref type="figure">S2</ref> in the ESI, &#8224; where the peaks of lowest energy 0-0 transition (A 0-0 ) and 0-1 first vibronic absorption transition (A 0-1 ) are labeled. The relative strength of A 0-0 and A 0-1 can be used to determine the type of aggregates. <ref type="bibr">41,</ref><ref type="bibr">43</ref> It is interesting to note that polymers form J-like aggregates (A 0-0 /A 0-1 4 1) in CF, whereas H-like aggregates (A 0-0 /A 0-1 o 1) are produced in DCB. This implies that intrachain coupling is stronger in CF and interchain coupling signal dominates in DCB. The aggregate fraction is plotted as a function of aging time in Fig. <ref type="figure">4(f)</ref>. It is clear that the polymer fraction that forms aggregates quickly reaches steady-state at 9% in CF. In contrast, no sign of the stabilization of aggregate concentrations is observed for DCB even after 97 h in solution. The fraction of polymer chains in aggregates can be as high as B17% with 30 min sonication time after 97 h of aging in DCB. Longer sonication times also results in sharper increases of the polymer fiber fraction.</p><p>In addition to UV-vis measurements, small angle neutron scattering (SANS) was carried out to quantitatively analyze fiber formation in solution. Moreover, this is a sensitive technique that probes the system over multi-length scales and can provide information on the cross-sectional dimensions of these polymer fibers. It is important to note that fiber fractions from SANS resolves RR-P3HT portions in fibril form, whereas UV-vis probes total aggregate fraction that may or may not incorporate into fibers. Fig. <ref type="figure">5</ref> shows the SANS profiles of RR-P3HT solution  with various sonication times in both CF and DCB after approximately 1 day of aging. After ex situ acoustic field irradiation, an increase in intensity at low-q range is observed in both solvents after sonication. In contrast, reference samples without ultrasonic treatment do not show fiber formation. The lack of assembly is also observed in the sTEM images shown in Fig. <ref type="figure">3</ref>. Also, the longer the insonation time, the more significant the enhancement of the SANS intensity (Fig. <ref type="figure">5(b)</ref>). A combined model, eqn (S1) in ESI, &#8224; is utilized to fit the scattering profiles to extrapolate the fiber fractions and cross-sectional dimensions. This model was successfully demonstrated by our group for nanofiber system containing dissolved polymers. <ref type="bibr">26,</ref><ref type="bibr">27,</ref><ref type="bibr">[44]</ref><ref type="bibr">[45]</ref><ref type="bibr">[46]</ref> Excluded volume effects (P PExV (q)) are considered when describing the dissolved polymers. <ref type="bibr">47,</ref><ref type="bibr">48</ref> Meanwhile, the nanofibers are modeled by a long parallelepiped form factor with a rectangular cross-section (P PP (q)). <ref type="bibr">49,</ref><ref type="bibr">50</ref> The details of the model and the corresponding equations are shown in the ESI. &#8224; A schematic representation of the cross-sectional height (a), width(b),andfiberlength(c)isillustratedintheinsetschematic drawing of Fig. <ref type="figure">5(b)</ref>. Both a and b are left as fitting variables while cisfixedat1mm, since it is outside of the q-range SANS is probing and cannot be determined accurately. However, this length can be justified by the fiber lengths observed from sTEM images (Fig. <ref type="figure">3</ref>). The fiber fraction for P3HT in chloroform after sonication is 2.79%, which is less than the fiber fractions obtained from UV-vis measurement (B9%). The difference could be due to the fact that UV-vis is probing the total number of aggregates but some of them may not be in fiber forms. For samples in DCB, the fiber percentages associated with each insonation periods are labeled in Fig. <ref type="figure">5(b</ref>). Longer exposure time to ultrasound leads to higher amounts of fiber formed. The fiber fractions after 10 min and 30 min ultrasound application time are 0.75% and 3.85%, respectively. The cross-sectional dimensions, 'a' and 'b', of the nanofibers formed in those two solvents, as extracted from SANS fits, are also listed in Table <ref type="table">1</ref>. The nanofiber formed in CF has a similar size to that in DCB, but may be a little thinner. The dimensions in both solutions are consistent with what is observed from sTEM images in Fig. <ref type="figure">2</ref>. They are also similar in size to P3HT fibers formed using poor solvent induced self-assembly. <ref type="bibr">26,</ref><ref type="bibr">44,</ref><ref type="bibr">46</ref> Acoustic fields can also affect the assembly of other conjugated polymers with different molecular structures. Side chain engineering is an important strategy in conjugated polymers to tune their solubility in solutions and molecular packing in films, which plays a critical role in affecting charge transport. It is also found that the final assembly structure is strongly dependent on side-chain arrangements. To gain insights into this, three polymers with variable regio-regularity, side chain length, and alkyl chain to thiophene ratio are chosen: regio-random P3HT (RRa-P3HT), P3DDT, and PQT-12. The molecular structures are depicted in the inset images in Fig. <ref type="figure">6</ref>. All the three polymers were dissolved in DCB at the same concentration (10 mg ml &#192;1 ). The samples are either not treated or exposed to 10 min ultrasound irradiation in the sonication bath.</p><p>The steep slope of the SANS profile in the low-q region of RRa P3HT in Fig. <ref type="figure">6</ref>   The models used for fitting the experimental data are the sphere model <ref type="bibr">51</ref> combined with dissolved polymer with excluded volume for RRa P3HT and also a combined model of parallelepipeds <ref type="bibr">49,</ref><ref type="bibr">50</ref> with dissolved polymer with excluded volume for PQT-12. The scattering profile of P3DDT is fit with just the dissolved polymer model with excluded volume. <ref type="bibr">47,</ref><ref type="bibr">48</ref> while fixing the total concentration of polymers. The results are tabulated in Table <ref type="table">2</ref>. Based on the fits, sonication can break these clusters down to smaller sizes from 441 nm to 57 nm while, a tt h es a m et i m e ,al i t t l eo v e rs i xt i m e sm o r ep o l y m e rc h a i n sa r e assembled into these aggregated clusters of RRa polymer. It is worth mentioning that a small fraction of the RRa P3HT polymers form aggregates in solution even before sonication. Considering that the fit has an estimated uncertainty of AE0.01%, this value is still much smaller than the aggregated polymer fraction that results after ultrasound.</p><p>In comparison, by increasing the side chain length from 6 carbons to 12 carbons (P3DDT), the scattering profile remains unchanged after sonication (Fig. <ref type="figure">6(b)</ref>). This suggests that P3DDT may be closer to a thermodynamically stable solution in these solvents due to a higher solubility imposed by the longer chains. A simple model of dissolved polymer with excluded volume is used to fit this data. The radius of gyration (R g ) is found to be 5.8 nm with Porod exponent being 1.8.</p><p>In contrast, SANS profiles of PQT-12, which has the same side chain length as P3DDT but half the number of side chains per chain length, shows significant ultrasound effects (Fig. <ref type="figure">6(c)</ref>). Interestingly, sonication changes the scattering profile by increasing intensity at low-q. sTEM images were also utilized to visualize the final structure formed by PQT-12 (Fig. <ref type="figure">S4</ref> in ESI &#8224;). Without sonication, PQT-12 itself has a strong tendency to selfassemble into complex structures. They can form short fibers that are 4100 nm long, or spherulites that can be up to several micro-meters in diameter. After sonication, longer fibers are observed and the large spherulitic particles become more branched on the perimeter. To quantify the fraction and cross-sectional sizes of the fibril structure, the parallelepiped model combined with the dissolved polymer model was used once again. Since the spherulites are large in size, the SANS results in this q-range characterizes both the free-standing fibers and also the fibril shapes grouped radially within the spherulites. The fiber crosssectional dimensions are similar in size, but the polymer fraction in fiber form is enhanced by about one order of magnitude from 0.03% to 0.3% after sonication. The fitting results are summarized in Table <ref type="table">3</ref>.</p><p>Well-characterized focused acoustic field experiments were also used to quantitatively draw mechanistic information. Typically, acoustic wave fields in laboratory sonication baths are chaotic and complex. This means that acoustic pressure distributions vary from place to place and may also change as a function of time. Moreover, sonication baths only operate at low frequencies (20-40 kHz) where cavitation is always present and also have poor power level control to sweep over acoustic pressures. In order to better control the incident acoustic field that is applied to the polymer solution, spherically focused transducers were utilized to systematically vary the applied acoustic pressures at the focal point and to reduce the influence of acoustic reflections. Samples in this setup were also characterized during ultrasound application to more effectively correlate the process of fiber formation to the acoustic field. Since polymer solutions in chloroform show instantaneous color change right after ultrasound application (Fig. <ref type="figure">4</ref>), UV-vis measurement was also used to calculate the aggregate fraction. The normalized UV-vis spectra are plotted in Fig. <ref type="figure">S5</ref> in the ESI. &#8224; The cavitation probability, which is defined as the probability of detecting a cavitation event from each acoustic pulse, for pure chloroform is shown in Fig. <ref type="figure">7</ref> as a function of peak negative pressure. The threshold pressure for cavitation is at B4 MPa, above which the cavitation dominates. Below this pressure, the sample is still exposed to the acoustic field and its effects, but not to the violent temperature and flow fluctuations that are induced by bubble cavitation.</p><p>Results (Fig. <ref type="figure">7</ref>) show that the cavitation pressure is closely related to the onset for fiber formation, below which the polymers stay fully dissolved. When the system is exposed to a pressure above threshold, the longer the irradiation time, the higher the amount of fibers formed. Fig. <ref type="figure">S6</ref> in the ESI &#8224; shows a series of UV-vis spectra collected under 7.2 MPa over different ultrasound durations. This shows that B100 s of insonation is enough to induce fiber formation. On the other hand, 1500 s of sonication more than doubled the amount of fibers compared  to that obtained with just 100 s. In contrast, if the peak negative pressure is below the threshold, 3 MPa for example, even four times longer ultrasound application time (6000 s) is not enough to result in any observable optical change (Fig. <ref type="figure">S7</ref> in the ESI &#8224;). Compared to solutions in chloroform, the optical change right after ultrasound application in DCB is not as obvious (Fig. <ref type="figure">4</ref>). In order to probe the instantaneous structural change under ultrasound, a new sample environment was built to allow for in situ characterization using scattering techniques (i.e. SANS, SAXS, USAXS). Fig. <ref type="figure">2</ref> shows a schematic view of the setup. The sample holder is sandwiched between two identical transducers that operate alternatively to prevent accumulation of materials on either side of the container via sonophoresis. Thin Kapton films are used as front and back windows of the sample cell to provide transparent pathways for the X-ray or neutron beam. Fig. <ref type="figure">8(a)</ref> shows scattering profiles obtained from a combination of USAXS and SANS of RR-P3HT in DCB during sonication. Similar to ex situ SANS results for samples exposed to ultrasound in a sonication bath (Fig. <ref type="figure">5</ref>), an increase in intensity is observed at the low-q range (o0.01 &#197; &#192;1 )o f the data after exposure to acoustic waves at 7.2 MPa, demonstrating the formation of fiber structures. USAXS allows probing of a much lower q-range (0.0001 &#197; &#192;1 o q o 0.001 &#197; &#192;1 )a n di tw a su s e dt o track simultaneous structural changes for polymer solutions under ultrasound as a function of insonation time. Fig. <ref type="figure">8(a)</ref> shows a substantial increase of USAXS (i.e. low q) intensity after just 5 min of ultrasound application. The extension in sonication time lead to increased scattering intensities and decreased slopes. A power law model (eqn (1)) is used to fit the USAXS data from 0.00014 to 0.0006 &#197; &#192;1 , where both the scale factor (B) and power-law exponents (A) are left as variables for fitting.</p><p>Fig. <ref type="figure">8</ref>(b) shows the fit results corresponding to both of the parametersineqn(1)asafunctionofsonicationtime.Thepowerlaw exponent starts at B3.3 and steadily decreased to B2.3 at 17 min. It then plateaus with increased sonication time. The scale factor (B) is proportional to the fiber volume and the total amount of polymer that is forming assembled structures. This parameter increasesandreachessteadystate at the same time as the powerlaw exponents plateau. By fitting the SANS data at low-q range (0.003 to 0.01 &#197; &#192;1 ), a similar power-law exponent (2.39) and scale factor (6.96 &#194; 10 &#192;6 ) as in the USAXS data are obtained showing consistency in the results. All fit results are plotted with the corresponding scattering profile in Fig. <ref type="figure">S9</ref> in the ESI. &#8224; Consistent with what is observed in P3HT samples in DCB that are insonated with sonication baths, no optical shift was observed when aging for a short time (10 h) (Fig. <ref type="figure">S10</ref>(a) in ESI &#8224;), in spite of the obvious changes in the scattering profiles. After an extended time aging (108 days), crystallization is observed for polymer solutions with and without ultrasound treatment based on new absorption peak formation of UV-vis spectra (Fig. <ref type="figure">S10(b</ref>) in ESI &#8224;). sTEM images also confirm that nanofibers are formed in both samples that were aged for 108 days. However, without ultrasound treatment the fibers are thick and short (typically under 500 nm) while nanofibers formed on sonicated samples are several micro-meters long.</p><p>A question still remains as to whether ultrasound can provide enough energy to induce crystallization for samples dissolved in even better solvents. To do this we used bromobenzene, which is a much better solvent for P3HT. Bromobenzene has more than five times higher solubility than DCB and to the best of our knowledge is currently the best known solvent for P3HT. <ref type="bibr">52</ref> In addition, deuterated bromobenzene also provides good neutron scattering contrast for P3HT. The polymer concentration and insonation time are kept the same as samples in DCB. nucleation. Polymers are in a coil conformation after they are fully dissolved at higher temperatures. <ref type="bibr">53,</ref><ref type="bibr">54</ref> When the applied acoustic wave exceeds the cavitation threshold pressure for the solvent, bubbles form. Due to rectified diffusion into and out of the bubbles, ultrasound oscillation favors bubble growth until the bubbles grow large enough to resonate with the field and collapse under the positive pressure phase of acoustic waves. <ref type="bibr">29</ref> The large pressures generated during the bubble collapse process alters the polymer chains to induce a more planar configuration that is more favorable for p-p stacking. This is evidenced by the UV-vis data in Fig. <ref type="figure">4</ref>(a) that improved intrachain coupling is observed right after sonication in CF. It is possible that strong shear fields, which are produced by ultrasound induced cavitation, are able to stretch the chains allowing them to form extended conformations. If two extended polymers get close to each other, they could form larger structures that serve as nucleation sites for further crystallization into nanofibers. Another possibility is that the formation of a new bubble-liquid interface may also trigger the assembly of conjugated polymer nanofibers. When cavitation is generated, polymer chains can accumulate at the interface by adsorption. Since bubbles undergo a large volume expansion, they sweep through a large region of the solvent. This increases the opportunity for polymer chains to assemble when the bubble collapses and they are brought close to each other. Unfortunately, our current data is insufficient to unequivocally determine the dominating effect.</p><p>To provide evidence of nuclei formation under ultrasound at early stages, in situ scattering characterization experiments were performed. USAXS data in Fig. <ref type="figure">8</ref>(a) shows that nucleation sites are formed after very short time of sonication (within 5 min). The high power-law exponents at the beginning of the sonication process in Fig. <ref type="figure">8</ref>(b) indicates that the initial structures are highly branched. Those fractal dimensions are typical values that are also observed in P3HT colloidal and gel system. <ref type="bibr">10,</ref><ref type="bibr">44</ref> The decrease of the power-law exponents can be attributed to the favored growth of fibril structure due to one-dimensional sonocrystallization (Fig. <ref type="figure">10</ref>) or the breakup of the large aggregates into small anisotropic fibrils. At the same time, the scale factor of the power law model increased with longer time of sonication. The scale factor is proportional to the volume fraction of fibers in solution and the increase can be explained by the integrated energy that is placed into the system by continued ultrasound insonation. An equilibrium is eventually established at around 17 min of sonication, which could be a steady-state process involving the growth of new fibers induced by ultrasound, the mechanical fracture of larger fibers and the re-dissolution of fibers through dissipated heat. In a much better solvent, such as in bromobenzene (Fig. <ref type="figure">9</ref>), the initial nucleation is also observed with ultrasound but it is not as obvious as in 1,2-dichlorobenzene. This could be due to a larger energy barrier for inducing sonocrystallization. Since bromobenzene is a better solvent, it should be easier to re-dissolve the nucleation sites and limit the equilibrium concentration of nucleation sites. During the scattering experiment, the energy input from ultrasound could also potentially raise the sample temperature and affect the crystallization. However, an increase in temperature would act in reverse to the process of assembly since it would further increase the solubility of the polymer in the solvent. Therefore, it is conclusive that the nucleation of fibers that is observed in scattering experiments originates from ultrasound induced cavitation.  In all the 'good' solvents that were investigated in this work, nucleation and growth of fibers still resulted from application of ultrasound. It is important to note that this suggests that none of the samples were 'good' solvents in a thermodynamic sense (i.e. where the solvated state is a minimum free energy configuration). Indeed, the crystalline nanofiber state represented a minimum energy configuration and the polymer samples were only kinetically stabilized (Fig. <ref type="figure">1</ref>). This argument is further supported by the formation of nanofibers from fully dissolved RR-P3HT in DCB after aging for 108 days (Fig. <ref type="figure">S10(c</ref>) in the ESI &#8224;). When the temperature is raised, polymers fully dissolve in a thermodynamic sense but, as the temperature is lowered to room temperature, the polymer chains are kinetically trapped in a local energy minimum and crystallization is slowed down. Ultrasound only accelerates the crystallizationprocessbypr ovi dingv eryhig h energy locally and in a short time to enable polymers to achieve other configurations.</p><p>Based on the above mechanism, ultrasound serves as the driving force for polymers to assemble into nucleation sites. At the same time, the high mechanical energy is also likely to break up larger structures (i.e. sonofragmentation). It is important to note that ultrasound does not break apart covalent bonds and cause polymer chain scission. This is proved by gel permeation chromatography (GPC) measurement that no obvious change is observed on P3HT samples before and after ultrasound application (Table <ref type="table">S2</ref> in the ESI &#8224;). The unaffected molecular weight by ultrasound is also reported by Amassian's group. <ref type="bibr">25</ref> For large structures, it has been demonstrated by kinetics experiment that the primary mechanism for sonofragmentation is based on shock waves. <ref type="bibr">55</ref> The shock wave generated during cavitation collapse can break assembled nanofibers preventing them from growing too long. In systems with violent cavitation events, such as chloroform (i.e. low cavitation threshold) under high peak negative pressures, defects can be generated that are detrimental for producing high quality nanofibers. UV-vis results in chloroform show that very small amounts of fibers formed right after sonication (Fig. <ref type="figure">4</ref>) but growth continued after sonication was halted.</p><p>SANS data of RRa P3HT (Fig. <ref type="figure">6</ref>(a)) also reveals that large aggregates are broken into smaller sizes after sonication while at the same time the total fraction of polymers in aggregate form increased (Table <ref type="table">2</ref>). The decreased size can be attributed to sonofragmentation and the increased volume fraction of aggregates is due to sonocrystallization. For PQT-12 (Fig. <ref type="figure">6(c</ref>)), SANS also confirms that ultrasound assembles the polymer chains into fibers. On the other hand, sTEM results in Fig. <ref type="figure">S4(c)</ref> and<ref type="figure">(d)</ref> in ESI &#8224; suggest that smaller fibers are fragments produced by ultrasound breakup of branched spherulites. Although both processes are observed in polymer systems and caused by the ultrasound field, sonocrystallization is the desirable effect for improving charge transport by producing nanofibers for electronic applications. Thus, it is important to understand the underlying physics of both processes.</p><p>In sonocrystallization, after nucleation sites are initially formed, an aging process without any additional ultrasound produces larger fibers without an acoustic field to break the fibers (Fig. <ref type="figure">3</ref>). In chloroform, although fiber formation is observed by UV-vis right after sonication, the majority of the fibers (B4 times more) come from aging after cessation of ultrasound. In Fig. <ref type="figure">4</ref>(f), the quick establishment of a steady-state aggregate concentration in chloroform is due to the low cavitation threshold of the solvent (Fig. <ref type="figure">S8</ref> in ESI &#8224;), which results in more cavitation events and nucleation sites at a given acoustic input.</p><p>In contrast, P3HT in DCB has a higher cavitation threshold (Fig. <ref type="figure">S8</ref> in ESI &#8224;) and a larger energy barrier to confine polymers in the fully dissolved local minimum, creating fewer nucleation sites. Therefore, it does not form enough crystallites to cause optical shifts in UV-vis measurement right after ultrasound application without aging. This also results in a slower crystallization process, which produces longer fibers (Fig. <ref type="figure">3(c</ref>)). A longer sonication time in DCB also results in faster fiber growth because more energy input produces more crystalline nuclei. For this reason, both the UV-vis and SANS data show that longer sonication times creates more fibers (Fig. <ref type="figure">4</ref>(f) and 5).</p><p>It is worth mentioning that the capability of tuning the excitonic coupling could be useful for changing the population of different spin states, thus controlling the photophysics. <ref type="bibr">41</ref> For example, J-like aggregates have been shown to promote triplet formation that leads to stronger photoluminescence (PL) quenching as compared to H-like aggregates. <ref type="bibr">41</ref> Not many reports exist on methods to form J-like aggregates. They are often formed in toluene and it requires polymers to have high regioregularity or low dispersity. <ref type="bibr">43,</ref><ref type="bibr">56,</ref><ref type="bibr">57</ref> This work provides an alternative and simple method to reliably generate J-like aggregates from commercially available P3HT in chloroform. The aggregate type can also be tuned using different solvents. In Fig. <ref type="figure">4</ref>(a), polymers exhibit stronger intrachain coupling in CF (J-like aggregates), which indicates that p-p stacking is weaker than when compared to fibers formed in DCB (H-like aggregates). The stronger intrachain coupling in CF could also explain why the fiber length is shorter in CF as compared to DCB.</p><p>During the crystallization process, the interactions between polymer chains can alter the final assembled structures. This can be achieved by changing the polymer molecular structure, such as the side chains as shown in Fig. <ref type="figure">6</ref>. RRa-P3HT (Fig. <ref type="figure">6(a)</ref>) is known not to crystallize because of the steric hindrance imposed by randomly oriented side chains. Still, ultrasound promotes polymer chains to form aggregates (Table <ref type="table">2</ref> and Fig. <ref type="figure">S3</ref> in ESI &#8224;). In contrast, RR polythiophenes with longer side-chains (i.e. 12 carbons in P3DDT) achieve a high solubility at room temperature so that ultrasound fields are unable to produce any fiber crystallization or induced-assembly. Interestingly, assembled structures can still be induced by ultrasound for PQT-12, which also has long side-chains (12 carbons) but fewer chains-per-monomer resulting in a lower solubility when compared to P3DDT. Therefore, the capacity to sonocrystallize a conjugated polymer seems to correlate best with its solubility.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Conclusions</head><p>In summary, it is demonstrated that P3HT can be assembled into nanofibers under ultrasound in solvents that are commonly believed to be 'good' solvents in a thermodynamic sense. Our results suggest that the dissolved state of these polymers is not a global minimum in the free-energy landscape. The formation of fiber in solution was quantified by both UV-vis and SANS measurements with consistent results. Ultrasound was determined to induce the formation of nucleation sites in the system and continued aging without acoustic insonation is crucial to achieve high fiber fractions. The molecular structure of the conjugated polymers was also found to be critical for ultrasounddirected polymer assembly. It was also shown via in situ experiments that polymer assembly is strongly correlated to solvent cavitation. The mechanism of sonocrystallization is proposed to be based on nucleation-and-growth.</p></div><note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_0"><p>This journal is &#169; The Royal Society of Chemistry 2018</p></note>
		</body>
		</text>
</TEI>
