skip to main content

Title: Label-Free Optical Detection of Multiple Biomarkers in Sweat, Plasma, Urine, and Saliva
We report a novel label-free quantitative detection of human performance “stress” biomarkers in different body fluids based on optical absorbance of the biomarkers in the ultraviolet (UV) region. Stress biomarker (hormones and neurotransmitters) concentrations in bodily fluids (blood, sweat, urine, saliva) predict the physical and mental state of the individual. The stress biomarkers primarily focused on in this manuscript are cortisol, serotonin, dopamine, norepinephrine, and neuropeptide Y. UV spectroscopy of stress biomarkers performed in the 190–400 nm range has revealed primary and secondary absorption peaks at near-UV wavelengths depending on their molecular structure. UV characterization of individual and multiple biomarkers is reported in various biofluids. A microfluidic/optoelectronic platform for biomarker detection is reported, with a prime focus toward cortisol evaluation. The current limit of detection of cortisol in sweat is ∼200 ng/mL (∼0.5 μM), which is in the normal (healthy) range. Plasma samples containing both serotonin and cortisol resulted in readily detectable absorption peaks at 203 (serotonin) and 247 (cortisol) nm, confirming feasibility of simultaneous detection of multiple biomarkers in biofluid samples. UV spectroscopy performed on various stress biomarkers shows a similar increasing absorption trend with concentration. The detection mechanism is label free, applicable to a variety of biomarker types, more » and able to detect multiple biomarkers simultaneously in various biofluids. A microfluidic flow cell has been fabricated on a polymer substrate to enable point-of-use/care UV measurement of target biomarkers. The overall sensor combines sample dispensing and fluid transport to the detection location with optical absorption measurements with a UV light emitting diode (LED) and photodiode. The biomarker concentration is indicated as a function of photocurrent generated at the target wavelength. « less
Authors:
;
Award ID(s):
1841509 1841473
Publication Date:
NSF-PAR ID:
10127277
Journal Name:
ACS sensors
Volume:
4
Issue:
5
Page Range or eLocation-ID:
1346-1357
ISSN:
2379-3694
Sponsoring Org:
National Science Foundation
More Like this
  1. Stress biomarkers produced by the body are briefly reviewed and our recent research is presented. Quantitative detection using aptamer-LFA demonstrated against cortisol, dopamine, and endotoxin. Microfluidic label-free optical method presented simultaneous detection of multiple biomarkers in bodily fluids, promising real-time detection. Lastly, future biomarker detection is discussed.
  2. Lab-on-a-chip technology offers an ideal platform for low-cost, reliable, and easy-to-use diagnostics of key biomarkers needed for early screening of diseases and other health concerns. In this work, a graphene field-effect transistor (GFET) functionalized with target-binding aptamers is used as a biosensor for the detection of thrombin protein biomarker. Furthermore, this GFET is integrated with a microfluidic device for enhanced sensing performances in terms of detection limit, sensitivity, and continuous monitoring. Under this platform, a picomolar limit of detection was achieved for measuring thrombin; in our experiment measured as low as 2.6 pM. FTIR, Raman and UV-Vis spectroscopy measurements weremore »performed to confirm the device functionalization steps. Based on the concentration-dependent calibration curve, a dissociation constant of K D = 375.8 pM was obtained. Continuous real-time measurements were also conducted under a constant gate voltage ( V GS ) to observe the transient response of the sensor when analyte was introduced to the device. The target selectivity of the sensor platform was evaluated and confirmed by challenging the GFET biosensor with various concentrations of lysozyme protein. The results suggest that this device technology has the potential to be used as a general diagnostic platform for measuring clinically relevant biomarkers for point-of-care applications.« less
  3. Wearable technologies for personalized monitoring require sensors that track biomarkers often present at low levels. Cortisol—a key stress biomarker—is present in sweat at low nanomolar concentrations. Previous wearable sensing systems are limited to analytes in the micromolar-millimolar ranges. To overcome this and other limitations, we developed a flexible field-effect transistor (FET) biosensor array that exploits a previously unreported cortisol aptamer coupled to nanometer-thin-film In 2 O 3 FETs. Cortisol levels were determined via molecular recognition by aptamers where binding was transduced to electrical signals on FETs. The physiological relevance of cortisol as a stress biomarker was demonstrated by tracking salivarymore »cortisol levels in participants in a Trier Social Stress Test and establishing correlations between cortisol in diurnal saliva and sweat samples. These correlations motivated the development and on-body validation of an aptamer-FET array–based smartwatch equipped with a custom, multichannel, self-referencing, and autonomous source measurement unit enabling seamless, real-time cortisol sweat sensing.« less
  4. Abstract. We assessed the influence of the marine diazotrophic cyanobacterium Trichodesmium on the bio-optical properties of western tropical South Pacific (WTSP) waters (18–22°S, 160°E–160°W) during the February–March 2015 OUTPACE cruise. We performed measurements of backscattering and absorption coefficients, irradiance, and radiance in the euphotic zone with a Satlantic MicroPro free-fall profiler and took Underwater Vision Profiler 5 (UPV5) pictures for counting the largest Trichodesmium spp. colonies. Pigment concentrations were determined by fluorimetry and high-performance liquid chromatography and picoplankton abundance by flow cytometry. Trichome concentration was estimated from pigment algorithms and validated by surface visual counts. The abundancemore »of large colonies counted by the UVP5 (maximum 7093coloniesm−3) was well correlated to the trichome concentrations (maximum 2093trichomesL−1) with an aggregation factor of 600. In the Melanesian archipelago, a maximum of 4715trichomesL−1 was enumerated in pump samples (3.2m) at 20°S,16730°E. High Trichodesmium abundance was always associated with absorption peaks of mycosporine-like amino acids (330, 360nm) and high particulate backscattering, but not with high Chl a fluorescence or blue particulate absorption (440nm). Along the west-to-east transect, Trichodesmium together with Prochlorococcus represented the major part of total chlorophyll concentration; the contribution of other groups were relatively small or negligible. The Trichodesmium contribution to total chlorophyll concentration was the highest in the Melanesian archipelago around New Caledonia and Vanuatu (60%), progressively decreased to the vicinity of the islands of Fiji (30%), and reached a minimum in the South Pacific Gyre where Prochlorococcus dominated chlorophyll concentration. The contribution of Trichodesmium to zeaxanthin was respectively 50, 40 and 20% for these regions. During the OUTPACE cruise, the relationship between normalized water-leaving radiance (nLw) in the ultraviolet and visible and chlorophyll concentration was similar to that found during the BIOSOPE cruise in the eastern tropical Pacific. Principal component analysis (PCA) of OUTPACE data showed that nLw at 305, 325, 340, 380, 412 and 440nm was strongly correlated to chlorophyll and zeaxanthin, while nLw at 490 and 565nm exhibited lower correlations. These results, as well as differences in the PCA of BIOSOPE data, indicated that nLw variability in the greenish blue and yellowish green during OUTPACE was influenced by other variables associated with Trichodesmium presence, such as backscattering coefficient, phycoerythrin fluorescence and/or zeaxanthin absorption, suggesting that Trichodesmium detection should involve examination of nLw in this spectral domain.

    « less
  5. Abstract

    Active biofluid management is central to the realization of wearable bioanalytical platforms that are poised to autonomously provide frequent, real-time, and accurate measures of biomarkers in epidermally-retrievable biofluids (e.g., sweat). Accordingly, here, a programmable epidermal microfluidic valving system is devised, which is capable of biofluid sampling, routing, and compartmentalization for biomarker analysis. At its core, the system is a network of individually-addressable microheater-controlled thermo-responsive hydrogel valves, augmented with a pressure regulation mechanism to accommodate pressure built-up, when interfacing sweat glands. The active biofluid control achieved by this system is harnessed to create unprecedented wearable bioanalytical capabilities at both themore »sensor level (decoupling the confounding influence of flow rate variability on sensor response) and the system level (facilitating context-based sensor selection/protection). Through integration with a wireless flexible printed circuit board and seamless bilateral communication with consumer electronics (e.g., smartwatch), contextually-relevant (scheduled/on-demand) on-body biomarker data acquisition/display was achieved.