Title: Open software platform for automated analysis of paper-based microfluidic devices
Abstract Development of paper-based microfluidic devices that perform colorimetric measurements requires quantitative image analysis. Because the design geometries of paper-based microfluidic devices are not standardized, conventional methods for performing batch measurements of regularly spaced areas of signal intensity, such as those for well plates, cannot be used to quantify signal from most of these devices. To streamline the device development process, we have developed an open-source program called ColorScan that can automatically recognize and measure signal-containing zones from images of devices, regardless of output zone geometry or spatial arrangement. This program, which measures color intensity with the same accuracy as standard manual approaches, can rapidly process scanned device images, simultaneously measure identified output zones, and effectively manage measurement results to eliminate requirements for time-consuming and user-dependent image processing procedures.  more » « less
Award ID(s):
1846846
PAR ID:
10169828
Author(s) / Creator(s):
; ;
Publisher / Repository:
Nature Publishing Group
Date Published:
Journal Name:
Scientific Reports
Volume:
10
Issue:
1
ISSN:
2045-2322
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Code-multiplexed Coulter sensors can easily be integrated into microfluidic devices and provide information on spatiotemporal manipulations of suspended particles for quantitative sample assessment. In this paper, we introduced a deep learning-based decoding algorithm to process the output waveform from a network of code- multiplexed Coulter sensors on a microfluidic device. Our deep learning-based algorithm both simplifies the design of coded Coulter sensors and increases the signal processing speed. As a proof of principle, we designed and fabricated a microfluidic platform with 10 code-multiplexed Coulter sensors, and used a suspension of human ovarian cancer cells as a test sample to characterize the system. Our deep learning-based algorithm resulted in an 87% decoding accuracy at a sample processing speed of 800 particles/s. 
    more » « less
  2. Paper-based microfluidic devices are an attractive platform for developing low-cost, point-of-care diagnostic tools. As paper-based devices’ detection chemistries become more complex, more complicated devices are required, often entailing the sequential delivery of different liquids or reagents to reaction zones. Most research into flow control has been focused on introducing delays. However, delaying the flow can be problematic due to increased evaporation leading to sample loss. We report the use of a CO2 laser to uniformly etch the surface of the paper to modify wicking speeds in paper-based microfluidic devices. This technique can produce both wicking speed increases of up to 1.1× faster and decreases of up to 0.9× slower. Wicking speeds can be further enhanced by etching both sides of the paper, resulting in wicking 1.3× faster than unetched channels. Channels with lengthwise laser-etched grooves were also compared to uniformly etched channels, with the most heavily grooved channels wicking 1.9× faster than the fastest double-sided etched channels. Furthermore, sealing both sides of the channel in packing tape results in the most heavily etched channels, single-sided, double-sided, and grooved, wicking over 13× faster than unetched channels. By selectively etching individual channels, different combinations of sequential fluid delivery can be obtained without altering any channel geometry. Laser etching is a simple process that can be integrated into the patterning of the device and requires no additional materials or chemicals, enabling greater flow control for paper-based microfluidic devices. 
    more » « less
  3. Abstract Droplet microfluidics enable high-throughput screening, sequencing, and formulation of biological and chemical systems at the microscale. Such devices are generally fabricated in a soft polymer such as polydimethylsiloxane (PDMS). However, developing design masks for PDMS devices can be a slow and expensive process, requiring an internal cleanroom facility or using an external vendor. Here, we present the first complete droplet-based component library using low-cost rapid prototyping and electrode integration. This fabrication method for droplet microfluidic devices costs less than $12 per device and a full design-build-test cycle can be completed within a day. Discrete microfluidic components for droplet generation, re-injection, picoinjection, anchoring, fluorescence sensing, and sorting were built and characterized. These devices are biocompatible, low-cost, and high-throughput. To show its ability to perform multistep workflows, these components were used to assemble droplet “pixel arrays, where droplets were generated, sensed, sorted, and anchored onto a grid to produce images. 
    more » « less
  4. The correct interpretation of the result from a point-of-care device is crucial for an accurate and rapid diagnosis to guide subsequent treatment. Lateral flow tests (LFTs) use a well-established format that was designed to simplify the user experience. However, the LFT device architecture is inherently limited to detecting analytes that can be captured by molecular recognition. Microfluidic paper-based analytical devices (µPADs), like LFTs, have the potential to be used in diagnostic applications at the point of care. However, µPADs have not gained significant traction outside of academic laboratories, in part, because they have often demonstrated a lack of homogeneous shape or color in signal outputs, which consequently can lead to inaccurate interpretation of results by users. Here, we demonstrate a new class of µPADs that form colorimetric signals at the interfaces of converging liquid fronts (i.e., lines) to control where colorimetric signals are formed without relying on capture techniques. We demonstrate our approach by developing assays for three classes of analytes—an ion, an enzyme, and a small molecule—to measure using iron (III), acetylcholinesterase, and lactate, respectively. Additionally, we show these devices have the potential to support multiplexed assays by generating multiple lines in a common readout zone. These results highlight the ability of this new paper-based device architecture to aid the interpretation of assays that create soluble products by using flow to constrain those colorimetric products in a familiar, line-format output. 
    more » « less
  5. We report the implementation of a fully on-chip, lensless microscopy technique termed optofluidic ptychography. This imaging modality complements the miniaturization provided by microfluidics and allows the integration of ptychographic microscopy into various lab-on-a-chip devices. In our prototype, we place a microfluidic channel on the top surface of a coverslip and coat the bottom surface with a scattering layer. The channel and the coated coverslip substrate are then placed on top of an image sensor for diffraction data acquisition. Similar to the operation of a flow cytometer, the device utilizes microfluidic flow to deliver specimens across the channel. The diffracted light from the flowing objects is modulated by the scattering layer and recorded by the image sensor for ptychographic reconstruction, where high-resolution quantitative complex images are recovered from the diffraction measurements. By using an image sensor with a 1.85 μm pixel size, our device can resolve the 550 nm linewidth on the resolution target. We validate the device by imaging different types of biospecimens, including C. elegans , yeast cells, paramecium , and closterium sp . We also demonstrate a high-resolution ptychographic reconstruction at a video framerate of 30 frames per second. The reported technique can address a wide range of biomedical needs and engenders new ptychographic imaging innovations in a flow cytometer configuration. 
    more » « less