<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Methods for determining equiluminance in terms of L/M cone ratios</title></titleStmt>
			<publicationStmt>
				<publisher></publisher>
				<date>04/09/2020</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10172331</idno>
					<idno type="doi">10.1167/jov.20.4.22</idno>
					<title level='j'>Journal of Vision</title>
<idno>1534-7362</idno>
<biblScope unit="volume">20</biblScope>
<biblScope unit="issue">4</biblScope>					

					<author>Jingyi He</author><author>Yesenia Taveras Cruz</author><author>Rhea T. Eskew</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[Heterochromatic flicker photometry (HFP), minimum motion (MM), and minimally distinct border (MDB)settings have often been used to determine equiluminance, a relative intensity setting for two chromaticities that, in theory, eliminates the responses of a luminance or achromatic psychophysical mechanism. These settings have been taken to reflect the relative contribution of the long (L) and medium (M) wavelength cones to luminance, which varies widely across individuals. The present study compares HFP, MM, and MDB using stimuli that do not modulate the short (S) wavelength cones, in both practiced and naïve observers. MDB was performed with both flashed and steadily viewed stimuli. Results are represented in the (L/L, M/M) plane of cone contrast space. Considering both practiced and naïve observers, both MM and HFP had excellent within-subject precision and high test-retest reliability, whereas HFP also had low between-subject variability. The MDB tasks were less reliable and less precise. The mean L:M contrast ratios at equiluminance were lower for the two temporal tasks (HFP and MM) compared to the spatial tasks (MDB), perhaps consistent with the existence of multiple luminance mechanisms. Overall, the results suggest that the best method for determining equiluminance is HFP, with MM being a close second.
Luminous efficiency represented in cone contrast spaceIn the present study, stimuli only modulated the L and M cones, with the S cone quantal catch kept constant. We present the results in the (L/L, M/M) plane of cone contrast space (Figure 1b). In this space, each axis represents the modulation or change in cone quantal catch due to a test light (e.g., L) divided Citation:]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Introduction</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Luminous efficiency functions V(&#955;)</head><p>Photometric luminance was originally defined by the International Commission on Illumination (CIE) using the 1924 V(&#955;) function, which is based on data from several experimental methods <ref type="bibr">(Wyszecki &amp; Stiles, 1982)</ref>. Proposals to modify the shape of the curve to better agree with psychophysical data, most notably that of Judd <ref type="bibr">(Vos, 1978)</ref>, eventually led to a "physiologically relevant" CIE standard <ref type="bibr">(CIE, 2006</ref><ref type="bibr">(CIE, , 2015))</ref>. One method used to define these V(&#955;) curves was heterochromatic flicker photometry (HFP). In HFP, the observer sets the radiance of each test light to minimize the perceived flicker of the test as it alternates with a standard light; when the tests are monochromatic, the result is a function of wavelength, HFP(&#955;). The curve reflects the activity of the long (L) and medium (M) wavelength cones with little or no input from the short (S) wavelength cones <ref type="bibr">(Eisner &amp; Macleod, 1981;</ref><ref type="bibr">Smith &amp; Pokorny, 1975)</ref>, under the measurement conditions that are most commonly employed <ref type="bibr">(Ripamonti, Woo, Crowther, &amp; Stockman, 2009)</ref>, and the modern standard is modeled as a weighted sum of the Stockman-Sharpe L and M cone fundamentals <ref type="bibr">(Stockman &amp; Sharpe, 2000)</ref>. Because of the relatively high temporal frequency that is normally used in HFP, the minimization of the sensation of flicker that defines the curve is generally believed to result from minimizing the activity in the magnocellular pathway <ref type="bibr">(Lee, Martin, &amp; Valberg, 1988)</ref>. However, luminance and chromatic information may be multiplexed in the parvocellular pathway <ref type="bibr">(Ingling &amp; Martinez, 1983;</ref><ref type="bibr">Ingling &amp; Martinez-Uriegas, 1983)</ref>, and thus there may, in fact, be more than one luminance pathway (for discussion, see <ref type="bibr">Stockman &amp; Brainard, 2010)</ref>.  <ref type="formula">2011</ref>), along with its L cone and M cone fundamental components, all as functions of wavelength. The black bell-shaped curve is the V D65 *(&#955;) curve. The red and green curves are the L cone and M cone fundamentals, respectively, in energy units. The two weighted fundamentals add up to the V D65 *(&#955;). (b) Transformation of 1/V D65 *(&#955;) values to the (L/L, M/M) plane of cone contrast space, at 5-nm steps, from 425 to 675 nm. Each point represents the ( M/M)/( L/L) ratio for a specific wavelength at the flicker null <ref type="bibr">(Eskew et al., 1999;</ref><ref type="bibr">Sharpe et al., 2011)</ref>. Data were downloaded from <ref type="url">http://www.cvrl.org</ref>.</p><p>by the cone activity produced by the steady lights to which the observer is adapted (L) <ref type="bibr">(Brainard, 1996;</ref><ref type="bibr">Eskew, McLellan, &amp; Giulianini, 1999)</ref>. Thus, the origin represents the adapting condition, and the increments and decrements in cone activity are represented in the four quadrants of the plane; the second and fourth quadrants (QII and QIV), in which the two cone contrasts have opposite signs, are the focus of attention in this study.</p><p>Figure <ref type="figure">1</ref> illustrates the relationship between a traditional luminous efficiency curve and its cone contrast representation. In panel (a), we plot the CIE (2006) 2&#176;V D65 *(&#955;) luminous efficiency function of <ref type="bibr">Sharpe, Stockman, Jagla, and J&#228;gle (2005)</ref> in energy terms, as derived from HFP <ref type="bibr">(Sharpe, Stockman, Jagla, &amp; J&#228;gle, 2011;</ref><ref type="bibr">Stockman, Jagle, Pirzer, &amp; Sharpe, 2008)</ref>. V D65 *(&#955;) is intended to be used for daylight (D65) adapting conditions; the data were corrected for chromatic adaptation to the test lights themselves. The height of the curve represents flicker sensitivity as a function of wavelength, relative to a 560-nm standard light. When the sensitivity curve is inverted, its height is proportional to the radiance required to minimize the flicker of the test light against the standard light (for an average observer). The curve is a sum of the L (red curve) and M (green curve) cone fundamentals, with the L function weighted by 1.98 compared to the M function. Like any HFP(&#955;) function, V D65 *(&#955;) represents stimuli.</p><p>In contrast, a luminance or achromatic mechanism may be modeled as a weighted sum of cone signals <ref type="bibr">(Eskew et al., 1999;</ref><ref type="bibr">Kaiser &amp; Boynton, 1996;</ref><ref type="bibr">Stockman &amp; Brainard, 2010;</ref><ref type="bibr">Stromeyer et al., 2000)</ref>. Under conditions where the cones adapt independently according to Weber's law, the effect of adaptation may be accounted for by representing the cone signals as contrasts; thus,</p><p>with k 1 and k 2 being non-negative weights. When the response is constant, as is believed to be the result of HFP, the equation forms a line in the (L/L, M/M) plane. For simplicity, we assume that the modulation produced in the luminance mechanism is zero at the HFP setting-that is, when the test and standard are equiluminant.</p><p>In Figure <ref type="figure">1b</ref>, the inverses of the sensitivities from the V D65 *(&#955;) curve at every 5 nm have been transformed into L and M cone contrasts (assuming fixed adapting conditions and cone-independent, Weberian adaptation 1 ); in effect, we have computed the pair of cone contrast values for the test peak of the flicker waveform at different wavelengths of flicker. The cone contrast pairs fall along a line through the origin; this line is parallel to the luminance mechanism threshold line under these same assumptions <ref type="bibr">(Eskew et al., 1999)</ref>. At equiluminance, test wavelengths shorter than 560 nm produce relatively positive modulations in the M cones and negative modulations in the L cones, and test wavelengths longer than 560 nm produce positive modulations in the L cones and negative modulations in the M cones, at the peak of the flickering waveform, both in reference to the 560-nm standard. The 560-nm light produces zero contrast when it is both test and standard and therefore plots at the origin. The HFP thresholds from V D65 *(&#955;) fall along a line of slope -2.23. Downloaded from jov.arvojournals.org on 05/02/2020</p><p>As shown in Appendix A, the relative L cone fundamental weight w in an HFP function such as V D65 *(&#955;) is equal to the slope in cone contrast space multiplied by the ratio of the two adapting levels, M adapt /L adapt . According to the ideas outlined above, at the HFP setting where the mechanism response is zero,</p><p>As shown in Appendix A, the relative weight (w) on the L cone fundamental in V D65 *(&#955;) (Figure <ref type="figure">1a</ref>) is</p><p>Under the stated (rather restrictive) conditions, the relative adaptive states determine the relative contribution of the L and M cones to this HFP function, as also shown by <ref type="bibr">Stockman et al. (2008)</ref> using a different approach.</p><p>In addition to using HFP to model the relative L/M inputs to luminance mechanisms, HFP settings have been taken as indicating the relative numbers of L and M cones in the retina <ref type="bibr">(Gunther &amp; Dobkins, 2002;</ref><ref type="bibr">Kremers et al., 2000;</ref><ref type="bibr">Rushton &amp; Baker, 1964)</ref>. This latter interpretation is complicated, as the relative L-to-M input to HFP-and thus the given luminous efficiency function V(&#955;)-is altered by chromatic adaptation <ref type="bibr">(Eisner &amp; Macleod, 1981;</ref><ref type="bibr">Stockman et al., 2008;</ref><ref type="bibr">Stromeyer, Cole, &amp; Kronauer, 1987)</ref>, and obviously the cone numbers are not (for discussion, see <ref type="bibr">Stockman &amp; Sharpe, 2000)</ref>. However, if the adapting conditions are held constant-something that is not the case in conventional HFP studies with monochromatic lights <ref type="bibr">(Stockman et al., 2008)</ref>-then the relative weighting of L-to-M fundamentals w might be proportional to the relative cone numbers. The relative cone contrast weight k 1 /k 2 might be more directly related to relative cone numbers, as the contrast calculation approximately accounts for adaptation.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Current study</head><p>For all the reasons discussed above, the determination of luminance sensitivity is potentially important. Various methods have been used and compared previously (see, for example, <ref type="bibr">Koenderink, van Doorn, &amp; Gegenfurtner, 2018;</ref><ref type="bibr">Lennie, Pokorny, &amp; Smith, 1993;</ref><ref type="bibr">Stockman &amp; Brainard, 2010;</ref><ref type="bibr">Wagner &amp; Boynton, 1972)</ref>. The current study compares four different methods for setting equiluminance in both practiced and na&#239;ve observers, with the primary goal of the study being to select the most precise and reliable method for use with modern stimulus generation technology and minimizing changes in chromatic adaptation due to the stimuli (see the section on effects of adaptational changes). Overall, HFP and minimum motion (MM) proved to be the best methods, and there were intriguing suggestions of differences between the temporal tasks (HFP and MM) and the spatial tasks (minimally distinct border [MDB]).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Methods</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Observers</head><p>Two groups of observers participated in this study. Twenty-two participants were undergraduate students from Northeastern University who received course credit for their participation. These observers were na&#239;ve, having had no prior psychophysical experience and no knowledge of the theory underlying the experiment. All of these observers reported having normal color vision. The second group consisted of four practiced observers, all of whom were experienced with psychophysical observation and also knowledgeable about the experimental hypotheses and background. The experienced observers had normal scores on the Farnsworth-Munsell 100-hue test <ref type="bibr">(Farnsworth, 1943)</ref>, normal performance on the Ishihara plates, and normal Rayleigh match settings on a Nagel anomaloscope.</p><p>This study was approved by the Northeastern University Institutional Review Board. All procedures followed the principles in the Declaration of Helsinki. Informed consent was provided by all observers.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Apparatus</head><p>Stimuli presentation was performed using an Apple Mac computer (Cupertino, CA) running a Bits# display controller (Cambridge Research Systems, Rochester, UK), which drove a Sony GDM-F520 CRT monitor (Tokyo, Japan) at an 85-Hz frame rate. Experimental software was written in MATLAB (MathWorks, Natick, MA) using the Psychtoolbox <ref type="bibr">(Kleiner, Brainard, &amp; Pelli, 2007)</ref>.</p><p>The experiment was conducted in a dark room. Head position was stabilized using a chin rest, at a distance of 130 cm from the screen. A 4.9&#176;black X, with its central 3.4&#176;(diagonal) blank, guided fixation in all experiments. Experienced observers viewed the stimulus monocularly by their dominant eye through ophthalmic trial lenses, with the other eye patched. Na&#239;ve participants viewed the screen binocularly and wore their own corrective eyewear.</p><p>The monitor spectra were carefully calibrated with a Photo Research PR-650 spectroradiometer (Photo Research, Chatsworth, CA), and gamma correction was achieved by loading in a look-up table to the Bits#. Luminance of the mid-gray (x = 0.289, y = 0.315) background was 75 cd/m 2 (approximately 2.6 log Td). Temporal frequency of the flickering stimuli was calibrated by an oscilloscope driven by a fast photocell.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Tasks and stimuli</head><p>Four different tasks were performed by each observer, each at two levels of stimulus contrast (Figure <ref type="figure">2</ref>). For the MM task <ref type="bibr">(Anstis &amp; Cavanagh, 1983;</ref><ref type="bibr">Cavanagh, MacLeod, &amp; Anstis, 1987)</ref>, a 2&#176;square patch was filled with the superposition of two 2.5-cycles/degree (cpd) horizontal gratings, a chromatic grating (chromaticity in the L/M plane) and an achromatic grating (black and white). These gratings were superimposed and displaced by a quarter cycle vertically and flickered at 2 Hz to create motion (i.e., the bars moved either upward or downward) (Figure <ref type="figure">2a</ref>). When the two color components of the chromatic grating have input equal to the motion mechanism-presumably a luminance input-the perceived motion is eliminated, and the net result is a counterphase flickering grating. When the luminance component of one chromaticity is stronger than the other, upward or downward motion is perceived. Observers adjusted the stimulus chromaticity (as described below) to minimize the sensation of motion, leaving predominantly or only a flickering percept.</p><p>For the HFP task <ref type="bibr">(Ives, 1912)</ref>, a 2&#176;square spot was sine-wave flickered between two complementary color directions at 10.63 Hz (Figure <ref type="figure">2b</ref>). Observers adjusted the stimulus chromaticity to minimize the sensation of flicker. The MDB task <ref type="bibr">(Boynton, 1978;</ref><ref type="bibr">Boynton &amp; Kaiser, 1968;</ref><ref type="bibr">Kaiser, Herzberg, &amp; Boynton, 1971</ref>) had two variations. The stimulus in both variants was an isolated edge <ref type="bibr">(McLellan, Goodman, &amp; Eskew, 1994)</ref>, created by multiplying a horizontal step edge by a two-dimensional Gaussian (centered at fixation, with a 1&#176;standard deviation) (Figure <ref type="figure">2c</ref>). In variant 1 (MDB1), the stimulus was flashed with a sawtooth temporal profile for 500 ms (Figure <ref type="figure">2d</ref>). The observers' task was to adjust the chromaticity of the two juxtaposed areas to minimize the distinctness of the central edge. A second MDB variation (MDB2) kept the stimulus steady, but the stimulus and task were otherwise the same as for MDB1.</p><p>The purpose of using a flashed stimulus for the MDB1 task was to minimize the observer's adaptation to the stimulus itself. Although at the threshold multiples used here there would be some change in the adaptation state during each presentation, there should be less with the flashed MDB1 compared to the steady MDB2. The MM and HFP stimuli modulate rapidly around the mean gray, so presumably they produce relatively little change in the observer's adaptive state as the chromatic angle is adjusted (as noted by <ref type="bibr">Gunther &amp; Dobkins, 2002)</ref>. Note that the HFP and MM tasks depend strongly on temporal factors, whereas the MDB tasks are primarily spatial.</p><p>The HFP and MM stimuli were 2&#176;square, and the two MDB tasks used a Gaussian blob with &#963; = 1&#176;. Stimuli size were kept at around 2&#176;to be able to better compare methods and to match the stimulus size in <ref type="bibr">Sharpe et al. (2011)</ref>. A moderate temporal frequency (10.63 Hz) for HFP was chosen to reduce S-cone sensitivity (for observers who are not exactly Stockman-Sharpe observers; see next paragraph). The spatial and temporal frequencies used in MM in our experiment were similar to values that have been used in previous studies. Changes in these parameters, especially the temporal frequency in MM, could have produced somewhat different results <ref type="bibr">(Cavanagh et al., 1987)</ref>.</p><p>All of the stimuli were calculated to be constant for S cones (they only modulated L and M) based upon the Stockman-Sharpe cone fundamentals <ref type="bibr">(Stockman &amp; Sharpe, 2000)</ref>. These fundamentals represent averages across variation in preretinal filtering, effective photopigment optical density, and cone &#955; max . Although it is certain that not all of our observers were exactly Stockman-Sharpe observers, and thus our calculated (L/L, M/M) plane does not completely eliminate S cone modulations in all cases, the actual S cone contrasts produced by our stimuli are likely to be low <ref type="bibr">(Smith &amp; Pokorny, 1995)</ref>. S cone contributions to the tasks used here have been shown to be quite small <ref type="bibr">(Boynton, Eskew, &amp; Olson, 1985;</ref><ref type="bibr">Cavanagh et al., 1987;</ref><ref type="bibr">Smith &amp; Pokorny, 1975)</ref>, and it is unlikely that our results are much influenced by actual S cone modulation across observers.</p><p>In the regions of primary interest in the (L/L, M/M) plane (QII and QIV), the monitor gamut was nearly parallel to the detection contour <ref type="bibr">(Giulianini &amp; Eskew, 1998</ref>  2016), as shown in Figure <ref type="figure">3</ref>. The stimuli in the present study were always on a contrast-scaled version of the gamut (gray contours in Figure <ref type="figure">3</ref>) and thus were very nearly a constant multiple of threshold (&#8764;2.7 and 5.4 times threshold of observer TGS in <ref type="bibr">Shepard et al., 2016)</ref>.</p><p>In each task, observers adjusted the stimulus chromaticity by the use of three pairs of buttons on a numeric keypad. These buttons altered the color angle of the stimulus in the (L/L, M/M) plane of cone contrast space (i.e., S cones were never modulated), with the three pairs producing large, medium, and small changes in one color rotation direction or its opposite. Figure <ref type="figure">4</ref> illustrates the procedure. The two peaks of the stimulus are displayed symmetrically around the origin, which represents the gray of the monitor background. The greenish component is generally in QII, where M cone contrast is positive and L cone contrast is negative, and the reddish component is generally in QIV, where L cone contrast is positive and M cone contrast is negative. Button presses moved the stimulus chromaticity along a line parallel to the gamut of the monitor in this plane of cone contrast space, with the distance of that line from the outer gamut being determined by the contrast: 25% or 50% of the maximum available (gray lines in Figure <ref type="figure">3</ref>). For a given task and contrast, the observers adjusted the stimulus angle (defined by the chromaticity of the stimulus component on the top half of the cone contrast plane) between 45 &#176;and 225 &#176;(with the stimulus constrained to lie on the gamut line) for the minimization judgment.  <ref type="figure">3</ref>). Using HFP as an example, the stimulus flickers between the two chromaticities at 10.63 Hz, as indicated by each of the thick arrows. The angle in the plane was adjusted to increase or decrease the ratio of M/M to L/L of the stimulus. For example, starting from 115&#176;and 295&#176;(flickering between bluish-green and purplish-pink), the observer could reduce the angle and set it to 60&#176;and 240&#176;( flickering between yellowish-green and light purple) or increase the angle and set it to 210&#176;and 30&#176;(flickering between blue and pink). Observers were instructed to find the angle that minimized the sensation of flicker (HFP), motion (MM), or distinctness of the central border (MDB1 and MDB2).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Procedure</head><p>The observers participated in either one or two sessions. The second session occurred at least 1 week after completion of the first one. During each session, four runs (for tasks MM, HFP, MDB1, and MDB2) were completed in random order. Prior to each run, the observers adapted to the gray screen for 60 seconds. Tones were used to signal the end of the adaptation period and the end of each trial. Each run consisted of 10 trials, five at each of the contrast levels (in random order). At the start of the run, the stimulus appeared on the screen with a random color angle. Observers then used the three pairs of keys of different levels of steps to adjust the chromaticity for the given criterion. In the MDB1 task, the stimulus was flashed with the time course shown in Figure <ref type="figure">2d</ref> when a key was pressed; in all the other tasks, the stimulus was continuously visible.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Results and discussion</head><p>Data of two na&#239;ve participants were excluded because they did not follow instructions. Four na&#239;ve observers participated in only one session. Therefore, all analyses were done based on four experienced observers Downloaded from jov.arvojournals.org on 05/02/2020 and the 14 na&#239;ve observers who participated in both sessions. The four na&#239;ve observers who completed only one session were excluded from the analysis of test-retest reliability, but their single session data were included in all of the other analyses.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Data analysis</head><p>Each setting results in two redundant cone contrast coordinates: the (L/L, M/M) for each of the two stimulus peaks (Figure <ref type="figure">4</ref>). The angle between 45&#176;and 225&#176;was used for analysis. An individual's equiluminant angle was calculated as the average of 20 settings (10 settings for the four subjects who completed one session). Two examples in the HFP task are shown in Figure <ref type="figure">5</ref>, a practiced observer and a na&#239;ve observer; each circle is a single setting, and the red line through the origin indicates the average equiluminant direction for this observer. The slope of this is the average ratio of M/M to L/L at equiluminance. For each observer, we computed a measure of the precision of the settings in each task using the 90% confidence limits on the mean angle.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Equiluminant angles</head><p>All settings are shown in histograms in Figure <ref type="figure">6</ref>; settings falling in the first quadrant (QI) or third quadrant (QIII) are indicated by angles less than 90&#176;o r larger than 180&#176;. Figure <ref type="figure">7</ref> illustrates the mean equiluminant directions for each of the four tasks, for the practiced observers in the left panel and the na&#239;ve observers in the right, and Table <ref type="table">1</ref> reports the descriptive statistics.</p><p>Figure <ref type="figure">8</ref> shows the mean angles for the practiced and na&#239;ve observers (left two panels) with indications of the variability across observers in mean angle. MM and HFP have the smallest angle (lowest L:M contrast ratio at equiluminance), with MDB1 and MDB2 producing larger angles (higher L:M contrast ratio at equiluminance), especially for the na&#239;ve group. The relative L to M contrast weight k 1 /k 2 (the negative of Figure <ref type="figure">6</ref>. Histograms of all settings. The practiced group is on the top and the na&#239;ve group is on the bottom.   but not from each other. These differences also hold at the level of the individual observer, not just in the means. As shown in Figure <ref type="figure">9</ref>, when plotting HFP or MM settings against settings of the average of the two MDB tasks, most of the points fall below the line of equality, indicating that MDB angles are generally larger than HFP or MM angles; the MDB occurs at a larger L:M ratio than the two temporal tasks.</p><p>The first column of Table <ref type="table">1</ref> shows the percentage of settings made in QI/QIII, in which the L and M contrasts have the same sign. For the practiced observers, all settings in the MM and the HFP task are in the second quadrant (as in Figures <ref type="figure">1b</ref> and<ref type="figure">7</ref>). The L and M cone contrasts at equiluminance have opposite signs as expected for a mechanism that sums cone contrasts (Equation <ref type="formula">1</ref>). A small fraction of the settings in the MDB tasks is in QI/QIII. For na&#239;ve participants, some settings in every task fall in QI (45&#176;to 90&#176;) or QIII (180&#176;to 225&#176;), with the HFP task having the lowest proportion, only 1.25%.</p><p>The right-hand panels in Figure <ref type="figure">8</ref> show 90% confidence intervals on the angles (inversely proportional to the precision of the settings); the means are given in Table <ref type="table">1</ref>. For the practiced observers, the MDB2 settings were less precise than the others, showing that the observers were inconsistent in their MDB settings when the stimulus was steadily presented. This might be an indication that observers were adapting to the steadily presented stimuli, changing their relative M:L adaptation across settings depending on the starting angle, making the results more variable. The na&#239;ve observers were less precise in general and had especially low precision for both MDB tasks; however, HFP had the same average precision for the two groups. Here, the ANOVA for the practiced group did reach conventional significance (F(3, 9) = 9.27, p &lt; 0.01), with LSD tests indicating that MM had greater precision than MDB2. For the na&#239;ve group, F(3, 51) = 48.68, p &lt; 0.01, and the LSD tests indicated that HFP and MM were more precise than the two MDBs.</p><p>Table <ref type="table">1</ref> also shows the between-subject standard deviation multiplied by 1.645 (the z-score corresponding to 90% confidence). HFP was most consistent across na&#239;ve observers, and MM was least consistent across practiced observers. It is important to note that this consistency may reflect genuine individual differences; thus, low consistency is not necessarily a negative characteristic in these tasks. Individual differences in psychophysical measurements of luminous efficiency are generally large <ref type="bibr">(Gibson &amp; Tyndall, 1923)</ref>; in <ref type="bibr">Sharpe et al. (2005)</ref>, the relative L cone weight required to fit HFP(&#955;) functions varied by a factor of 34 across observers (considering ser180 and ala180 L cone polymorphism observers together). Flicker electroretinogram (ERG)-derived L:M cone contribution ratios varied by a factor of about 32 in one study <ref type="bibr">(Carroll, Neitz, &amp; Neitz, 2002)</ref>. If we exclude the mean angles that fall outside of QII, the ranges of individual mean angles we found for practiced and na&#239;ve observers were 100.8&#176;to 149.0&#176;and 96.5&#176;to 178.6&#176;, respectively, and the corresponding L:M contrast weights ranged from 5.242 to 0.601 and 8.777 to 0.024, with factors of 9 and 366, respectively, combining the data from all tasks. In our HFP results, the average L:M contrast weight k 1 /k 2 across all participants (n = 22) was about 2.0 (and on this measure there was little difference between practiced and na&#239;ve participants relative to the variation within these groups) (Figure <ref type="figure">8</ref>; Table <ref type="table">1</ref>). <ref type="bibr">Sharpe et al. (2011)</ref> reported that their mean L:M weight in HFP was 2.67 (n = 40). This variation across studies and across individuals must include individual differences in preretinal filtering, effective cone optical density, and cone &#955; max , and perhaps as well as in L:M cone numbers. </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Inter-method consistency and test-retest reliability</head><p>Test-retest reliability was determined for observers who participated in both sessions, and the correlation coefficients are shown in Table <ref type="table">2</ref>. In the MM and HFP task, practiced observers show reliable settings across sessions; the correlations for MDB1 and MDB2 are not statistically different from zero. For the na&#239;ve group, the flicker photometry task has the highest reliability, and MM and MDB2 have good reliability. Intercorrelations among the tasks are reported in Table <ref type="table">3</ref>. Overall, the practiced observers show good agreement between MM and HFP tasks and between the two MDB tasks. The correlations between MM/HFP and MDB1/MDB2 are negative, suggesting disagreements between observer variation in the temporal tasks and the spatial tasks. However, these correlations are not statistically significant. For the na&#239;ve observers, all of the intercorrelations are positive. Like the practiced observers, the two temporal tasks (MM and HFP) are well correlated, as are the two spatial tasks (MDB1 and MDB2), but the temporal and spatial tasks are only weakly correlated, perhaps consistent with the negative intercorrelations for the practiced observers. These negative intercorrelations by the practiced observers may be worth further study, suggesting that perhaps the different methods of setting equiluminance may actually be tapping different systems.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Effects of adaptational changes</head><p>It is very well established that HFP(&#955;) functions change shape under different steady adaptation conditions <ref type="bibr">(Eisner &amp; Macleod, 1981;</ref><ref type="bibr">Stockman, MacLeod, &amp; Vivien, 1993)</ref>. <ref type="bibr">Stockman et al. (2008)</ref> dealt with the more difficult issue of adaptation to the test lights themselves, which alters relative L/M input across settings, even when the tests are fairly close to threshold (an effect corrected for in the V D65 *(&#955;) function of Figure <ref type="figure">1</ref>). The stimuli used in our MDB tasks are highly likely to alter the adaptation state of the observer as the adjustment was being made (as in most prior MDB studies; see <ref type="bibr">Ingling et al., 1978)</ref>, with the adaptational effect being perhaps smaller in the flashed MDB1 compared to the steady MDB2. This difference between the two MDB tasks might be consistent with the result that the precision of MDB1 is better than that of MDB2 for the practiced group (Figure <ref type="figure">8</ref>, upper right panel; Table <ref type="table">1</ref>, rightmost column).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>General discussion and conclusions</head><p>Of all the tasks, HFP produced the smallest proportion of settings in QI or QIII (Table <ref type="table">1</ref>); nearly all of the HFP settings produced L and M cone modulations of opposite sign, as expected for a mechanism that sums cone signals. In addition, na&#239;ve observers informally reported that HFP was the easiest task (and MDB was the hardest). The MM task shows good precision and moderate reliability; however, some participants reported that the MM stimulus was uncomfortable to view. This might have been due to our use of four diagonal lines to guide fixation. Those lines might have been insufficient to control eye movements in this task for the na&#239;ve observers, perhaps contributing to the discomfort; a small central dot might have been better.</p><p>The MDB tasks differ from HFP and MM in at least two important ways. First, the critical feature of the stimulus in MDB (the border itself) is likely to be centrally fixated by the observer, in comparison to the larger HFP and MM stimuli. Thus, retinal inhomogeneities (especially higher macular pigment density and higher cone photopigment optical density in central fovea) might contribute to differences between MDB and HFP/MM. The second difference is that the MDB tasks are primarily spatial, in contrast to the temporal HFP and MM tasks. One might therefore speculate that MDB might depend upon the multiplexed luminance signal in parvocellular neurons <ref type="bibr">(Ingling &amp; Martinez, 1983;</ref><ref type="bibr">Ingling &amp; Martinez-Uriegas, 1983)</ref>, whereas the temporal tasks could depend upon magnocellular activity <ref type="bibr">(Lee et al., 1988)</ref>. If this were the case, our results would suggest that, on average, near-foveal magnocellular cells would receive relatively stronger L cone input than parvocellular cells, as both our na&#239;ve and practiced observers required greater M cone contrasts to produce equiluminance in the temporal tasks compared to the MDB (Figure <ref type="figure">7</ref>; Table <ref type="table">1</ref>). However, complicating this interpretation of a magnocellular substrate for HFP and MM and a parvocellular substrate for MDB is the fact that MDB settings are undisturbed by moderate amounts of blur <ref type="bibr">(Lindsey &amp; Teller, 1989</ref>)-high acuity is not required-and, more to the point, the claim that magnocellular activity can account for MDB settings <ref type="bibr">(Kaiser, Lee, Martin, &amp; Valberg, 1990)</ref>. Nonetheless, this difference between spatial and temporal luminance tasks is worth further exploration, as are the effects of retinal inhomogeneity.</p><p>In Figure <ref type="figure">10a</ref>, we reconstruct an HFP(&#955;) based upon the mean of our practiced observers and our M adapt /L adapt ratio of 0.86, with the relative L cone fundamental weight being 1.32; compare this figure to Figure <ref type="figure">1a</ref>, which has a relative L cone fundamental weight of 1.98. This curve is the prediction, based upon our results, of the HFP using monochromatic lights, Downloaded from jov.arvojournals.org on 05/02/2020 assuming the observer's adaptation state did not change with test wavelength (or that the data were corrected for that change in adaptation) <ref type="bibr">(Stockman et al., 2008)</ref>. Figure <ref type="figure">10b</ref> shows the difference between the normalized V D65 *(&#955;) of Figure <ref type="figure">1</ref> and our reconstructed HFP(&#955;) in the top panel, as a function of wavelength. The differences are very small but are of course systematic.</p><p>For our stimulus conditions, and considering practiced and na&#239;ve observers together, heterochromatic flicker photometry proved to be the best method, in terms of its within-subject precision and high test-retest reliability across groups. The minimum motion task performed the second best among these tasks in the present study.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Keywords: equiluminance, luminance, luminous efficiency, cone contrast, heterochromatic flicker photometry (HFP), minimum motion (MM), minimally distinct border (MDB)</head><p>differently depending on the chromatic conditions <ref type="bibr">(Eisner &amp; Macleod, 1981;</ref><ref type="bibr">Sharpe et al., 2011;</ref><ref type="bibr">Stromeyer et al., 2000)</ref>.</p><p>The purpose of this appendix is to show how the weight (w) in an HFP function such as V* D65 (&#955;) in Figure <ref type="figure">1a</ref> is related to the cone contrast weight (k) under the limited conditions described above: von Kries adaptation and constant adaptation. We also ignore here possible phase shifts between the cone classes produced by differential adaptation <ref type="bibr">(Stromeyer et al., 1987;</ref><ref type="bibr">Stromeyer et al., 2000)</ref>.</p><p>In heterochromatic flicker photometry, the radiance of the test light is adjusted to minimize the flicker at each test wavelength; thus, the radiance of the test R(&#955;) is inversely proportional to the HFP(&#955;) function (for example, the V* D65 (&#955;) shown in Figure <ref type="figure">1a</ref>):</p><p>where C is the constant of proportionality. Thus, the effect of each monochromatic test light on the cones is L test = R(&#955;)L(&#955;) and M test = R(&#955;)M(&#955;), and from Equation A4 above we have for the mechanism at equiluminance</p><p>Comparing coefficients in Equations A6 and A7, we see that C = (k +1)M adapt and w = k(M adapt /L adapt ). This conclusion is analogous to one derived by <ref type="bibr">Stockman et al. (2008)</ref> using a different approach.</p><p>Thus, in modeling the results of a flicker photometric study by a weighted sum of the L and M cones, the relative L/M weight is given by the relative cone contrast weight (k) multiplied by the ratio of the two cone adapting states. The slope of the line in Figure <ref type="figure">1b is -k</ref>; the relative cone weight in Equation 2 and illustrated in Figure <ref type="figure">1a</ref> is k multiplied by the M-to-L adapting states.</p><p>Under the assumptions stated above, the weighting making up the HFP function depends upon the adapting states of the cones; the weighting of the cone contrasts in the mechanism does not because the cone contrasts take the adapting states into account.</p><p>Note that, although the M adapting state appears in both C and w above and L adapt only appears in w, there is nothing privileged about either of the two cone adapting conditions. If instead of casting the problem in terms of the weighting the L cone relative to the M cone as above, we instead begin with the relative weight being on the M cones, then</p><p>, where I = &#206; k 1 and As noted, von Kries adaptation holds only approximately true under some conditions, and the assumption that the adapting condition does not change across test wavelengths in HFP with monochromatic lights is probably never fulfilled <ref type="bibr">(Stockman et al., 2008)</ref>.</p></div><note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_0"><p>This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. Downloaded from jov.arvojournals.org on 05/02/2020</p></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_1"><p>Downloaded from jov.arvojournals.org on 05/02/2020</p></note>