<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Biodegradable Magnesium Bone Implants Coated with a Novel Bioceramic Nanocomposite</title></titleStmt>
			<publicationStmt>
				<publisher></publisher>
				<date>03/01/2020</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10191247</idno>
					<idno type="doi">10.3390/ma13061315</idno>
					<title level='j'>Materials</title>
<idno>1996-1944</idno>
<biblScope unit="volume">13</biblScope>
<biblScope unit="issue">6</biblScope>					

					<author>Mehdi Razavi</author><author>Mohammadhossein Fathi</author><author>Omid Savabi</author><author>Lobat Tayebi</author><author>Daryoosh Vashaee</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[Magnesium (Mg) alloys are being investigated as a biodegradable metallic biomaterial because of their mechanical property profile, which is similar to the human bone. However, implants based on Mg alloys are corroded quickly in the body before the bone fracture is fully healed. Therefore, we aimed to reduce the corrosion rate of Mg using a double protective layer. We used a magnesium-aluminum-zinc alloy (AZ91) and treated its surface with micro-arc oxidation (MAO) technique to first form an intermediate layer. Next, a bioceramic nanocomposite composed of diopside, bredigite, and fluoridated hydroxyapatite (FHA) was coated on the surface of MAO treated AZ91 using the electrophoretic deposition (EPD) technique. Our in vivo results showed a significant enhancement in the bioactivity of the nanocomposite coated AZ91 implant compared to the uncoated control implant. Implantation of the uncoated AZ91 caused a significant release of hydrogen bubbles around the implant, which was reduced when the nanocomposite coated implants were used. Using histology, this reduction in the corrosion rate of the coated implants resulted in an improved new bone formation and reduced inflammation in the interface of the implants and the surrounding tissue. Hence, our strategy using a MAO/EPD of a bioceramic nanocomposite coating (i.e., diopside-bredigite-FHA) can significantly reduce the corrosion rate and improve the bioactivity of the biodegradable AZ91 Mg implant.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="1.">Introduction</head><p>Over the last decade, the development of biodegradable orthopedic implants has significantly advanced <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref>. Completed and ongoing clinical trials for bone repair and regeneration are mostly focused on biodegradable ceramics include calcium phosphate (ClinicalTrials.gov Identifier: NCT02153372, and NCT02803177 in Germany). Although calcium phosphates are known to be bioactive and support osteoblast adhesion and proliferation <ref type="bibr">[4,</ref><ref type="bibr">5]</ref>, their major limitation is mechanical properties; namely, they are brittle with a poor fatigue resistance <ref type="bibr">[6]</ref><ref type="bibr">[7]</ref><ref type="bibr">[8]</ref>. Brittleness so far restricted their application to non-load bearing areas, filler or coating <ref type="bibr">[9]</ref>, rendering it impossible to use them for the repair or regeneration of load-bearing bone defects <ref type="bibr">[10]</ref><ref type="bibr">[11]</ref><ref type="bibr">[12]</ref>. Biodegradable polymers such as poly-L-lactic acid, poly-glycolic acid, and copolymers with Food and Drug Administration (FDA) approval for human clinical use have also been extensively used in preclinical studies of bone tissue engineering. However, the application of biopolymer materials suffers from poor processability and weak mechanical properties <ref type="bibr">[13]</ref>. Magnesium (Mg) alloys are significantly more flexible than bioceramics, mechanically stronger than biopolymers with the advantage of bioabsorption capabilities over other biometals <ref type="bibr">[14]</ref><ref type="bibr">[15]</ref><ref type="bibr">[16]</ref>. Mg is an essential mineral crucial to bone health and can even stimulate new bone formation, and its physical and mechanical properties are similar to those of human bones <ref type="bibr">[14,</ref><ref type="bibr">17,</ref><ref type="bibr">18]</ref>. Given these characteristics, Mg is considered an attractive element for forming a bone implant. However, a series of clinical trials using Mg-based implants failed prematurely due to the Mg's rapid corrosion and high hydrogen-evolution <ref type="bibr">[14]</ref>. A strategy to tackle this issue is to reduce Mg's corrosion rate <ref type="bibr">[19]</ref>, and the promising future of biodegradable Mg implants is dependent on being able to reduce their corrosion. Several treatments have been proposed to reduce Mg's corrosion rate, including Mg purification <ref type="bibr">[20]</ref>, fluoride conversion coatings <ref type="bibr">[21]</ref>, alloying <ref type="bibr">[19]</ref>, anodizing <ref type="bibr">[22]</ref>, and compositing <ref type="bibr">[23]</ref>.</p><p>An effective technique to reduce the Mg's corrosion rate is surface coating <ref type="bibr">[24]</ref>. For a bone implant, the surface coating can also enhance the implant's surface bioactivity (i.e., osteoproductivity), thereby resulting in improved bone-implant integration <ref type="bibr">[25]</ref>. As a coating material, silicate glass-ceramics are a suitable option given their low biodegradation and their ability for new bone formation <ref type="bibr">[26,</ref><ref type="bibr">27]</ref>. Biocompatible silicate glass-ceramics are diopside (CaMgSi 2 O 6 ) <ref type="bibr">[28]</ref>, akermanite (Ca 2 MgSi 2 O 7 ) <ref type="bibr">[29]</ref>, merwinite (Ca 3 MgSi 2 O 8 ) <ref type="bibr">[30]</ref>, and bredigite (Ca 7 MgSi 4 O 16 ) <ref type="bibr">[31]</ref>. We have previously synthesized and separately coated the mentioned glass-ceramics on Mg implants <ref type="bibr">[29,</ref><ref type="bibr">[32]</ref><ref type="bibr">[33]</ref><ref type="bibr">[34]</ref>. Our results showed that, among tested glass-ceramics, bredigite had the least biodegradation, and diopside indicated the greatest bioactivity.</p><p>Furthermore, compared to calcium phosphates coated on the surface of Mg implants, fluoridated hydroxyapatite (FHA: Ca 10 (PO 4 ) 6 (OH) 2-x F x ) has indicated the improved bioactivity and biocompatibility <ref type="bibr">[35]</ref>. Accordingly, we synthesized a diopside-bredigite-fluoridated hydroxyapatite nanocomposite and coated on the surface of an Mg implant. We used the electrophoretic deposition (EPD) method to coat our nanocomposite on the surface of the AZ91 Mg alloy. EPD was chosen since it offers many advantages as a coating method, including simplicity, cost-effectiveness, and environmentally friendly processing <ref type="bibr">[36,</ref><ref type="bibr">37]</ref>. EPD has also already been utilized for coating the bioceramics on the surface of biometals for orthopedic implants <ref type="bibr">[38]</ref><ref type="bibr">[39]</ref><ref type="bibr">[40]</ref>. However, before coating with EPD, we first treated our AZ91 substrate with micro-arc oxidation (MAO) technique. On an Mg alloy, a conversion coating such as MAO acts as an intermediate layer to reduce not only the Mg's corrosion rate, but also enhance the adhesion between the Mg and final coating <ref type="bibr">[22]</ref>.</p><p>Hence, the main aim of this work was to reduce the corrosion rate and also enhance the bioactivity of a biodegradable AZ91 Mg implant using a nanocomposite coating composed of diopside, bredigite, and fluoridated hydroxyapatite which was prepared using MAO/EPD technique.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.">Materials and Methods</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.1.">Preparation of AZ91 Mg Alloy Substrate</head><p>A commercial AZ91 Mg alloy (Al 9%, Zn 1%, Mn 0.2%, Fe &lt; 0.005%, all in wt.%) was machined to obtain the substrates with dimensions of 20 &#215; 15 &#215; 5 mm. Samples were then polished with SiC papers from 80 to 600 grit.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.2.">Surface Coating</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.2.1.">Nanocomposite Powder Preparation</head><p>The diopside, bredigite, and fluoridated hydroxyapatite (FHA) nanoparticles were first separately synthesized according to our previously published protocols <ref type="bibr">[16,</ref><ref type="bibr">41,</ref><ref type="bibr">42]</ref>. They were then blended with the ratio of 1/3:1/3:1/3, respectively, to acquire the nanocomposite powder. The nanocomposite powder was then coated on the surface of AZ91 samples using the combined MAO/EPD method.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.2.2.">Micro Arc Oxidation (MAO)</head><p>MAO was performed according to our previously published protocol <ref type="bibr">[22]</ref>. In brief, an AZ91 sample was used as the anode and a stainless-steel plate as the cathode electrode, an aqueous solution of NaOH (200 g/L) and Na 2 SiO 3 (200 g/L) as the electrolyte along with a power supply. MAO treatment was performed in the applied voltage of 60 V for 30 min.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.3.">Electrophoretic Deposition (EPD)</head><p>EPD was performed according to our previously published protocol <ref type="bibr">[42]</ref>. In brief, an AZ91 sample was used as the cathode and a graphite rod as the anode electrode. The electrolyte was a suspension of nanocomposite particles at a concentration of 10 g particles/100 mL methanol (99.9%). Before starting the EPD process, the nanoparticles were dispersed into the suspension by placing them in an ultrasonic bath for 60 min and then stirring with a magnetic stirrer for 30 min. EPD was then performed under a constant voltage of 100 V for 3 min at room temperature (Figure <ref type="figure">1</ref>). the ratio of 1/3:1/3:1/3, respectively, to acquire the nanocomposite powder. The nanocomposite powder was then coated on the surface of AZ91 samples using the combined MAO/EPD method.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.2.2.">Micro Arc Oxidation (MAO)</head><p>MAO was performed according to our previously published protocol <ref type="bibr">[22]</ref>. In brief, an AZ91 sample was used as the anode and a stainless-steel plate as the cathode electrode, an aqueous solution of NaOH (200 g/L) and Na2SiO3 (200 g/L) as the electrolyte along with a power supply. MAO treatment was performed in the applied voltage of 60 V for 30 min.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.3.">Electrophoretic Deposition (EPD)</head><p>EPD was performed according to our previously published protocol <ref type="bibr">[42]</ref>. In brief, an AZ91 sample was used as the cathode and a graphite rod as the anode electrode. The electrolyte was a suspension of nanocomposite particles at a concentration of 10 g particles/100 mL methanol (99.9%). Before starting the EPD process, the nanoparticles were dispersed into the suspension by placing them in an ultrasonic bath for 60 min and then stirring with a magnetic stirrer for 30 min. EPD was then performed under a constant voltage of 100 V for 3 min at room temperature (Figure <ref type="figure">1</ref>).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Figure 1. Schematic representation of MAO-EPD coating method:</head><p>In step 1, i.e., MAO, a power supply was used; an AZ91 sample was used as the anode and a stainless-steel plate as the cathode electrodes; a mixture of NaOH (200 g/L) and Na2SiO3 (200 g/L) were also used as the electrolyte solution. MAO was performed in the voltage of 60 V for 30 min. In step 2, i.e., EPD, an AZ91 sample was used as the cathode and a graphite rod as the anode electrode. A suspension of nanocomposite particles at a concentration of 10 g particles/100 mL methanol was also used as the electrolyte. EPD was then performed under a voltage of 100 V for 3 min at room temperature.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.4.">Characterizations</head><p>The size and morphology of synthesized nanocomposite particles were measured using a transmission electron microscope (TEM, JEOL JEM-2100). The morphology and chemical composition of surfaces were observed under a scanning electron microscope (SEM) equipped with energy dispersive MAO was performed in the voltage of 60 V for 30 min. In step 2, i.e., EPD, an AZ91 sample was used as the cathode and a graphite rod as the anode electrode. A suspension of nanocomposite particles at a concentration of 10 g particles/100 mL methanol was also used as the electrolyte. EPD was then performed under a voltage of 100 V for 3 min at room temperature.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.4.">Characterizations</head><p>The size and morphology of synthesized nanocomposite particles were measured using a transmission electron microscope (TEM, JEOL JEM-2100). The morphology and chemical composition of surfaces were observed under a scanning electron microscope (SEM) equipped with energy dispersive spectroscopy (EDS) (Philips XL 30: Eindhoven). The topography of surfaces was also observed using a laser scanning microscope (LSM) (Keyence, VK X100/X200). Phase structure analysis was performed using an X-ray diffractometer (XRD, Philips Xpert). The obtained XRD patterns were compared with the standards compiled by the Joint Committee on Diffraction Pattern and Standards (JCDPS). The grain size of synthesized nanocomposite particles was also estimated by broadening XRD peaks using the Williamson-Hall equation (Equation ( <ref type="formula">1</ref>)) <ref type="bibr">[43]</ref>:</p><p>where &#946; is the full width of diffraction peak (rad) in the middle of its height, &#952; is Bragg's angle ( &#8226; ), and &#955; is the wavelength of the X-ray (nm) considered after computer fitting of the X-ray data using Gaussian line shape. When &#946; cos&#952; is plotted against sin&#952;, a straight line is obtained with the slope of 2&#949; and the intercept as (0.89 &#955;/D) and the grain size, d (nm), can be calculated.</p><p>A compression test was performed on our AZ91 Mg alloy according to ASTM E9 standard. The rod samples with a diameter of 3 mm and a length of 6 mm were machined for the experiment. To measure the compressive properties of samples, we used an INSTRON 8562 universal tensile testing machine at a crosshead displacement rate of 0.5 mm/min.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.5.">Corrosion Tests</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.5.1.">Electrochemical Test</head><p>A PARSTAT 2273 Ametek potentiostat was used for measuring the electrochemical (i.e., polarization and electrochemical impedance spectroscopy (EIS)) properties of samples in the standard simulated body fluid (SBF) solution prepared according to Kokubo's protocol <ref type="bibr">[44]</ref>. A three-electrode cell was used include the working electrode (i.e., AZ91 sample), the reference electrode (i.e., calomel), and the counter electrode (i.e., platinum). The experiment started after the sample was incubated in the SBF solution for 60 min to be stabilized, and a scanning rate of 1 mV.s -1 was applied for the polarization experiment. The impedance data were recorded with a frequency range of 100 kHz to 10 mHz.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.5.2.">Immersion Test</head><p>The immersion test was performed in the SBF, according to ASTM-G31-72 <ref type="bibr">[45]</ref>, to monitor the corrosion rate of samples. Each sample was individually immersed into a falcon tube containing SBF and incubated at 37 &#8226; C for 672 h (28 days). The corrosion rate was determined by measuring the weight loss of each sample after 0, 72 h, 168 h, 336 h, 504 h, and 672 h immersion. The corrosion products formed on the surface of samples during the corrosion were removed using chromic acid (200 g/L CrO 3 ) <ref type="bibr">[16]</ref>. The difference in weight of samples before and after the immersion into chromic acid showed the amount of weight loss, and the corrosion rate of the samples was then calculated using the weight loss as a function of immersion time, according to Equation (2):</p><p>where W is the weight loss, A is the sample's surface area exposed to the SBF, and t is the immersion time.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.6.">In Vivo Animal Study</head><p>The animal experiments in our study were approved by the University Ethics Committee of the Isfahan University of Medical Sciences. Rabbits with average weights of 3 kg were anesthetized by subcutaneous administration of Ketamine (35 mg/kg), Xylazine (5 mg/kg) and Acepromazine (1 mg/kg). After anesthesia, the operation sites were shaved, decortication was carried out, and then the holes with 3 mm diameter were created at the greater trochanter of rabbits using a hand driller. AZ91, MAO, and composite coated rod implants (n = 3) were then implanted into the created bone defects. After the operation, all rabbits received subcutaneous injections of antibiotics. The rabbits were then allowed to move freely in their cages without any external support. The rabbits were sacrificed 2 months post-implantation. Also, a radiography imaging was performed on the implantation site 2 weeks after the surgery and prior to sacrificing the rabbits. For histology, the bone samples were fixed in the formaldehyde solution (4%), dehydrated using ethanol, and then decalcified in a nitric acid solution. The samples were then embedded in paraffin and cut into films. The sectioned samples were stained with Hematoxylin and Eosin (H&amp;E) stain, and the morphological and histological analyses were performed under a microscope to observe the bone regeneration and inflammation around the implant.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.7.">Statistical Analysis</head><p>All values were expressed as the mean &#177; standard deviation (SD). Statistical analysis of all quantitative data was performed using a one-way ANOVA (Analysis of Variance) with post-hoc Tukey test (Astatsa.com; Online Web Statistical Calculators, USA) with any differences considered statistically significant when p &lt; 0.05.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.">Results and Discussion</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.1.">Characterizations</head><p>The microstructure of our AZ91 Mg alloy substrate has been shown in Figure <ref type="figure">2a</ref>. Using compression test, we determined that this alloy has an elastic modulus of 45 GPa (Figure <ref type="figure">2b</ref>), which is similar to human cancellous bones (40 GPa) <ref type="bibr">[46]</ref>. This lower elastic modulus compared to biometals or bioceramics enhances implant-to-bone stress loading and can minimize bone atrophy due to stress shielding <ref type="bibr">[47]</ref>.</p><p>Materials 2020, 13, 1315 5 of 15 weeks after the surgery and prior to sacrificing the rabbits. For histology, the bone samples were fixed in the formaldehyde solution (4%), dehydrated using ethanol, and then decalcified in a nitric acid solution. The samples were then embedded in paraffin and cut into films. The sectioned samples were stained with Hematoxylin and Eosin (H&amp;E) stain, and the morphological and histological analyses were performed under a microscope to observe the bone regeneration and inflammation around the implant.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.7.">Statistical Analysis</head><p>All values were expressed as the mean &#177; standard deviation (SD). Statistical analysis of all quantitative data was performed using a one-way ANOVA (Analysis of Variance) with post-hoc Tukey test (Astatsa.com; Online Web Statistical Calculators, USA) with any differences considered statistically significant when p &lt; 0.05.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.">Results and Discussion</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.1.">Characterizations</head><p>The microstructure of our AZ91 Mg alloy substrate has been shown in Figure <ref type="figure">2a</ref>. Using compression test, we determined that this alloy has an elastic modulus of 45 GPa (Figure <ref type="figure">2b</ref>), which is similar to human cancellous bones (40 GPa) <ref type="bibr">[46]</ref>. This lower elastic modulus compared to biometals or bioceramics enhances implant-to-bone stress loading and can minimize bone atrophy due to stress shielding <ref type="bibr">[47]</ref>. The results of TEM imaging showed that our composite nanoparticles had a size of 50 &#177; 20 nm (Figure <ref type="figure">3a</ref>). Following MAO treatment, a porous and rough surface was formed on AZ91 samples (Figure <ref type="figure">3b</ref>). The MAO layer has been composed of one external porous layer and one internal compact barrier layer. The external layer is coarse with many microholes which have been formed due to the oxygen bubbles released during the growth process as well as the thermal stress as a result of the rapid solidification of the molten oxide in the relatively cooling electrolyte. However, the internal layer has been attached to the Mg substrate, is compact and uniform, and can act as a barrier to block the exposure of corrosive solutions to the Mg substrate <ref type="bibr">[48]</ref>. The compact internal layer can insulate the substrate from the corrosive electrolyte ions while the external layer can absorb more corrosive electrolytes and therefore reduce the corrosion resistance of the Mg alloy substrate. Hence, the external layer of the MAO coating should be sealed by another coating layer. In addition, an MAO layer with a porous and rough surface can offer sites for our composite nanoparticles to be settled in. We then coated our MAO treated AZ91 with composite nanoparticles using the EPD process. The nanocomposite coating could adequately cover the pores of the MAO layer; this can then prevent the MAO layer from The results of TEM imaging showed that our composite nanoparticles had a size of 50 &#177; 20 nm (Figure <ref type="figure">3a</ref>). Following MAO treatment, a porous and rough surface was formed on AZ91 samples (Figure <ref type="figure">3b</ref>). The MAO layer has been composed of one external porous layer and one internal compact barrier layer. The external layer is coarse with many microholes which have been formed due to the oxygen bubbles released during the growth process as well as the thermal stress as a result of the rapid solidification of the molten oxide in the relatively cooling electrolyte. However, the internal layer has been attached to the Mg substrate, is compact and uniform, and can act as a barrier to block the exposure of corrosive solutions to the Mg substrate <ref type="bibr">[48]</ref>. The compact internal layer can insulate the substrate from the corrosive electrolyte ions while the external layer can absorb more corrosive electrolytes and therefore reduce the corrosion resistance of the Mg alloy substrate. Hence, the external layer of the MAO coating should be sealed by another coating layer. In addition, an MAO layer with a porous and rough surface can offer sites for our composite nanoparticles to be settled in. We then coated our MAO treated AZ91 with composite nanoparticles using the EPD process. The nanocomposite coating could adequately cover the pores of the MAO layer; this can then prevent the MAO layer from being directly exposed to the corrosive solutions. Similar to the MAO layer, the surface of our nanocomposite coating was rough and porous (Figure <ref type="figure">3c,</ref><ref type="figure">d</ref>). Using LSM, the surface roughness of AZ91 obtained 5 &#177; 3 &#181;m; however, following coating with MAO and composite, the surface roughness increased to 12 &#177; 8, and 150 &#177; 80 &#181;m, respectively. This can promote bone-implant integration since previous research has suggested that a rough and porous surface can encourage cell attachment and bone in-growth, which can enhance the anchorage of the implant to the bone <ref type="bibr">[36]</ref>. Also, using SEM, the thickness of the MAO layer and nanocomposite coat obtained 100 and 250 &#181;m, respectively (Figure <ref type="figure">3e,</ref><ref type="figure">f</ref>). The line-scan analysis of the cross-sectional SEM image confirmed that the nanocomposite coat mainly consists of Ca, P, and Mg elements. The intensity of Ca and P gradually decreased from nanocomposite coat to substrate, while Mg had an opposite trend (Figure <ref type="figure">3e</ref>).</p><p>In the XRD pattern of the AZ91 substrate, Mg peaks were detected. When MAO treated AZ91 was tested with XRD, MgO, and Mg 2 SiO 4 peaks were detected. MgO is formed by dissolving Mg 2+ outward from the substrate and the oxidized oxygen O 2-inward from electrolyte according to reaction (3): At high temperatures, both SiO 2 and MgO are present in the fused state <ref type="bibr">[49]</ref>. However, during the interval stops of anodization sparking and micro-arcing, and by the cooling effect of the electrolyte, the fused state SiO 2 and MgO forms Mg 2 SiO 4 according to reaction (6):</p><p>Mg 2 SiO 4 is a bioactive ceramic <ref type="bibr">[50]</ref>, which can also have a protective effect on the AZ91 substrate <ref type="bibr">[22]</ref>.</p><p>The XRD patterns also confirmed the peaks related to diopside, bredigite, and FHA within the composite coat. The grain size of the composite coating was obtained to be approximately 25 nm according to the Williamson-Hall equation, confirming that our composite coating is a nanostructure material (Figure <ref type="figure">3g</ref>).  <ref type="figure">c,</ref><ref type="figure">d</ref>) and cross-section (e,f) of nanocomposite coated samples showing that the coating could effectively cover the pores of the MAO layer, the surface of nanocomposite coating was rough and porous, and the thickness of the MAO layer and nanocomposite coating was 100 and 250 &#181;m, respectively. Also, the line-scan analysis of the cross-sectional SEM image confirmed that the nanocomposite coating mainly consists of Ca, P, and Mg elements. The intensity of Ca and P gradually decreased from nanocomposite coat to substrate, while Mg had an opposite trend (e); (g) XRD patterns of AZ91, MAO, and nanocomposite coated samples showing that AZ91 substrate had peaks related to Mg; MAO treated AZ91 had MgO and Mg2SiO4 peaks, and nanocomposite coating had peaks related to diopside, bredigite, and FHA.  <ref type="figure">c,</ref><ref type="figure">d</ref>) and cross-section (e,f) of nanocomposite coated samples showing that the coating could effectively cover the pores of the MAO layer, the surface of nanocomposite coating was rough and porous, and the thickness of the MAO layer and nanocomposite coating was 100 and 250 &#181;m, respectively. Also, the line-scan analysis of the cross-sectional SEM image confirmed that the nanocomposite coating mainly consists of Ca, P, and Mg elements. The intensity of Ca and P gradually decreased from nanocomposite coat to substrate, while Mg had an opposite trend (e); (g) XRD patterns of AZ91, MAO, and nanocomposite coated samples showing that AZ91 substrate had peaks related to Mg; MAO treated AZ91 had MgO and Mg 2 SiO 4 peaks, and nanocomposite coating had peaks related to diopside, bredigite, and FHA.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.2.">Corrosion Tests</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.2.1.">Electrochemical Tests</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.2.">Corrosion Tests</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.2.1.">Electrochemical Tests</head><p>The values of corrosion current density (i corr ), and corrosion potential (E corr ) derived from the potentiodynamic polarization curves (Figure <ref type="figure">4a</ref>) showed that AZ91 sample has a 63,100 nA/cm 2 i corr ; This value decreased to 53,700, and 1.99 nA/cm 2 for MAO and nanocomposite coated samples, respectively. The polarization test also recorded an increase in E corr from -1.60 V to -1.56 and -1.45 V for AZ91, MAO, and nanocomposite coated samples, respectively. In general, a decrease in i corr and an increase in E corr is an indication of improvement in corrosion resistance <ref type="bibr">[51]</ref>. EIS Nyquist plots showed that the Zim/Zre ratio of AZ91 increased with the MAO and nanocomposite coating, indicating an enhanced capacitive behavior for the solid/liquid interface. The MAO and nanocomposite coated samples showed larger capacitive loops in the EIS spectra than the AZ91 sample. Since a larger diameter loop represents better corrosion resistance [52], the EIS results confirm that the MAO and nanocomposite coating can improve the corrosion resistance of the AZ91 Mg alloy. Also, in the Nyquist plots, two capacitive loops and one inductive loop are seen for samples, similar to previously reported Nyquist plots of pure Mg <ref type="bibr">[53]</ref>. The diameter of the loop in the high-frequency range is normally attributed to the charge transfer reaction, which is proportional to the transfer resistance value, i.e., R t . The larger the R t , the better is the corrosion resistance of coating <ref type="bibr">[16]</ref>. From R t value, the exchange-current density (j 0 ) could also be calculated using Equation ( <ref type="formula">7</ref>) <ref type="bibr">[54]</ref>:</p><p>where n is the number of transferred charges, and F is Faraday constant. In Equation ( <ref type="formula">7</ref>), j 0 is in opposite proportion to R t , i.e., the higher the R t is, the lower would be the corrosion rate <ref type="bibr">[53]</ref>. Hence, charge transfer resistance could be utilized to assess the corrosion rate of the samples. This is because an increase in j 0 should correspond to an increase in the corrosion rate. It can be deduced from EIS spectra that R t of AZ91 samples increased from 137.6 &#8486; cm 2 to 439.7 &#8486; cm 2 and 5432.7 &#8486; cm 2 for MAO and nanocomposite coated samples, suggesting that the nanocomposite coating is more corrosion resistant than AZ91, which is in good agreement with the results of polarization measurements (Figure <ref type="figure">4b</ref>). Hence, the results of electrochemical tests reveal the increased corrosion resistance afforded by the nanocomposite coating. A delayed corrosion process is critical for a biodegradable implant, as the implant needs to maintain its mechanical functionality for a certain period before the bone defect is fully healed <ref type="bibr">[55]</ref>. Therefore, the immersion tests can provide additional information regarding the corrosion rates of the AZ91, MAO, and nanocomposite coated samples for a longer time.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.2.2.">Immersion Tests</head><p>The corrosion rate of the AZ91 sample obtained significantly higher than the MAO and nanocomposite coated samples (0.57 &#177; 0.02 vs. 0.39 &#177; 0.01 and 0.08 &#177; 0.01 mg/cm 2 /hr, respectively after 72 h immersion in the SBF) showing the effective protection provided by the MAO and nanocomposite coating (Figure <ref type="figure">4c</ref>). Following the immersion test, local areas of the AZ91 surface were corroded, and many large cracks and pores were detected on the surface due to significant corrosion. Clusters of white particles had also been formed on the AZ91 surface (Figure <ref type="figure">4d,</ref><ref type="figure">g</ref>). The surface morphology of MAO treated AZ91 had too been corroded, and some pits and cracks were seen (Figure <ref type="figure">4e,</ref><ref type="figure">h</ref>). Comparing the surface morphology of samples following immersion showed that the density of cracks and pits formed on the AZ91 sample due to the corrosion were significantly higher than those formed on MAO and nanocomposite coated samples. It could be clearly seen that the MAO and nanocomposite coated samples had a more uniform and milder corrosion attack when compared to the AZ91 sample. The density of white particles formed on the surface of nanocomposite coated samples was also higher than MAO and AZ91 samples. In fact, the total surface of nanocomposite coated samples had been covered with cauliflower-like white particles (Figure <ref type="figure">4f,</ref><ref type="figure">i</ref>). Also, the degree of corrosion attack and formed white particles for the MAO sample was between AZ91 and nanocomposite coated samples (Figure <ref type="figure">4e,</ref><ref type="figure">h</ref>).  <ref type="figure">f</ref>) and after (g-i) removal of degradation products. SEM images show that the cracks and pits formed on the AZ91 sample due to the corrosion were significantly more than MAO and nanocomposite coated samples. Furthermore, the surface of nanocomposite coated samples had been totally covered with cauliflower-like white particles. Significant differences: * P &lt; 0.05: AZ91 vs. MAO or Composite coat, # P &lt; 0.05: MAO vs. Composite coat.</p><p>Due to the excellent castability, mechanical properties, corrosion resistance, and high maximum solubility of 12.7 wt.% in Mg, aluminum (Al) has been one of the most commonly used alloying elements for Mg-alloy systems in the early development stage of biodegradable orthopedic implants <ref type="bibr">[56]</ref>. Mg-Al alloy systems such as AZ alloys, which were already processed for industrial applications, are currently available for further optimization, such as a surface coating as used in our study. In general, an increased Al content in Mg alloys enhances the ultimate tensile strength (UTS) and elongation up to 6 wt.% while reducing the corrosion rate by forming an aluminum oxide film <ref type="bibr">[57]</ref>. Although Al is a well-known neurotoxicant linked with Alzheimer's disease and dementia <ref type="bibr">[58]</ref>, researchers argue that the amount of Al released from such alloy systems with less than 5 wt.% Al is well below the weekly intake limits, and long-term in vivo studies have shown no direct detrimental effect <ref type="bibr">[14,</ref><ref type="bibr">59]</ref>. AZ91 Mg alloy used in our study consists of 9 wt.% Al, i.e., higher than the threshold mentioned above (5 wt.%), however, using our nanocomposite coating system, the corrosion rate of AZ91 significantly reduced from 0.57 &#177; 0.02 to 0.08 &#177; 0.01 mg/cm 2 /hr which will also cause a significant reduction in Al release from our AZ91 substrate. Hence, our composite coated AZ91 offers a reduced corrosion rate as well as high mechanical properties.</p><p>The corrosion of Mg alloy proceeds by the following reactions:</p><p>Cathodic reaction:</p><p>Total reaction:  <ref type="figure">d-f</ref>) and after (g-i) removal of degradation products. SEM images show that the cracks and pits formed on the AZ91 sample due to the corrosion were significantly more than MAO and nanocomposite coated samples. Furthermore, the surface of nanocomposite coated samples had been totally covered with cauliflower-like white particles. Significant differences: * p &lt; 0.05: AZ91 vs. MAO or Composite coat, # p &lt; 0.05: MAO vs. Composite coat.</p><p>Due to the excellent castability, mechanical properties, corrosion resistance, and high maximum solubility of 12.7 wt.% in Mg, aluminum (Al) has been one of the most commonly used alloying elements for Mg-alloy systems in the early development stage of biodegradable orthopedic implants <ref type="bibr">[56]</ref>. Mg-Al alloy systems such as AZ alloys, which were already processed for industrial applications, are currently available for further optimization, such as a surface coating as used in our study. In general, an increased Al content in Mg alloys enhances the ultimate tensile strength (UTS) and elongation up to 6 wt.% while reducing the corrosion rate by forming an aluminum oxide film <ref type="bibr">[57]</ref>. Although Al is a well-known neurotoxicant linked with Alzheimer's disease and dementia <ref type="bibr">[58]</ref>, researchers argue that the amount of Al released from such alloy systems with less than 5 wt.% Al is well below the weekly intake limits, and long-term in vivo studies have shown no direct detrimental effect <ref type="bibr">[14,</ref><ref type="bibr">59]</ref>. AZ91 Mg alloy used in our study consists of 9 wt.% Al, i.e., higher than the threshold mentioned above (5 wt.%), however, using our nanocomposite coating system, the corrosion rate of AZ91 significantly reduced from 0.57 &#177; 0.02 to 0.08 &#177; 0.01 mg/cm 2 /hr which will also cause a significant reduction in Al release from our AZ91 substrate. Hence, our composite coated AZ91 offers a reduced corrosion rate as well as high mechanical properties.</p><p>The corrosion of Mg alloy proceeds by the following reactions:</p><p>Cathodic reaction:</p><p>Total reaction: Mg (s) + 2H 2 O (aq) &#8594; Mg(OH) 2 (s) + H 2 (g) , ( <ref type="formula">10</ref>)</p><p>Following the immersion of an Mg alloy in the SBF, the electrolyte penetration followed by chemical dissolution results in the substrate to undergo rapid corrosion, and a magnesium hydroxide (Mg(OH) 2 ) layer is then formed on its surface (reactions ( <ref type="formula">8</ref>)-( <ref type="formula">10</ref>)). The deposition of Mg(OH) 2 layer on the surface of the Mg alloy substrate can also act as a protective film that can prevent direct exposure of corrosion medium to Mg alloy. Mg(OH) 2 would then react with chloride ions in the SBF and form the soluble MgCl 2 (reaction ( <ref type="formula">11</ref>)) <ref type="bibr">[60]</ref>. This is the reason why our AZ91 Mg alloy sample had been subjected to a significant rate in the initial phase of immersion. Next, the formed corrosion product, which mainly contains Mg(OH) 2 , would thicken with immersion time, and the corrosion rate gradually decreases <ref type="bibr">[61]</ref>. Although Mg(OH) 2 forms on the surface of Mg alloy, it is too porous to protect the AZ91 substrate from corrosion effectively. Hence, continuous corrosion happens on Mg. This corrosion trend, i.e., fast corrosion initially followed by slow corrosion as time evolves, is also supported by our results (Figure <ref type="figure">4c</ref>). However, our MAO and nanocomposite coating could act as an effective barrier to protect the AZ91 substrate from corrosion. Ca 2+ ions and PO 4 3-groups from the SBF and Mg 2+ ions released from the AZ91 substrate also took part in the surface reaction of samples and form a calcium phosphate layer such as Ca 3 Mg 3 (PO 4 ) 4 on the sample (reaction ( <ref type="formula">12</ref>)) which has a cauliflower-like structure <ref type="bibr">[62]</ref>. Our SEM results also confirmed the formation of a layer with a cauliflower-like structure on the samples (Figure <ref type="figure">4f</ref>). The formation of this phosphate coating can further protect the substrate from fast corrosion <ref type="bibr">[63]</ref>. Therefore, a plateau in corrosion rates of AZ91, MAO, and nanocomposite coated samples were observed at the last stage of our immersion test, i.e., from 336 h to 672 h (Figure <ref type="figure">4c</ref>).</p><p>Mg 2+ + Ca 2+ + PO 4 3-&#8594; Ca 3 Mg 3 (PO 4 ) 4 .</p><p>(12)</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.3.">In Vivo Animal Study</head><p>Following implantation, animals did not exhibit any sign of moribund/lethargic, distress, or local infections. Also, a normal wound healing was reported post-operation. In radiography images, AZ91 implants showed the highest hydrogen bubbles formation at the beginning, followed by a reduction over time. However, hydrogen bubbles formation reduced when MAO implants were used, and almost no hydrogen bubbles were seen around the nanocomposite coated implants (Figure <ref type="figure">5d-i</ref>).</p><p>Similarly, previous research has also shown that hydrogen bubbles are found around the Mg implants, which are then disappeared after 2-3 weeks <ref type="bibr">[17,</ref><ref type="bibr">64]</ref>. In the first two weeks post-implantation, the rate of hydrogen-evolution from Mg implants is quicker than the hydrogen absorption rate. Over time, the corrosion rate reduces because of the formation of Mg(OH) 2 and other corrosion products such as Ca 3 Mg 3 (PO 4 ) 4 <ref type="bibr">[65]</ref>. Hence, the hydrogen bubbles around implants reduced from two weeks to two months. When the volume and weight of explanted implants were measured, the change in volume and weight of nanocomposite coated implants were significantly lower compared to AZ91 and MAO treated implants (volume change: 9.1 &#177; 0.2% vs. 42.8 &#177; 3.3% and 32 &#177; 1.7%; weight change: 4 &#177; 1 vs. 25 &#177; 4, and 16 &#177; 3 mg/cm 2 ) showing the reduced in vivo corrosion of AZ91 implants when coated with our composite nanoparticles. Using histology, we observed new bone had been formed around the implants for all implants. However, compare to both AZ91 and MAO implants, nanocomposite coated implants showed the highest amount of new bone formation (56 &#177; 5% vs. 27 &#177; 1% and 31 &#177; 2%; Figure <ref type="figure">5j-o,r</ref>). When inflammatory response in the tissue surrounding implants was compared, AZ91 had the highest inflammatory response; however, it decreased when MAO or composite coated implant was used (15 &#177; 3% vs. 42 &#177; 4% and 32 &#177; 4%; Figure <ref type="figure">5j-o,s</ref>). This increase in bone formation and reduction in inflammatory response due to the composite coating on implants can be due to several reasons. One reason is a reduced corrosion rate and, therefore hydrogen-evolution since the coating decreases the direct contact of the implant with the body fluid. Furthermore, the production of hydrogen bubbles due to high corrosion of Mg alloys can prevent physiological bone reaction and callus formation <ref type="bibr">[66]</ref>, thereby resulting in a decrease in new bone formation and higher inflammation around the uncoated implants when compared to the coated ones. Previous studies on biodegradable Mg alloys have shown that AZ91 Mg alloy corrodes at a rate of 1.1 mm/year [67], LAE442 at 2.8 mm/year <ref type="bibr">[68]</ref>, and WE43 at 3.9 mm/year <ref type="bibr">[69]</ref>. Zinc, another biodegradable metallic implant, corrodes at a rate of 0.2 mm/year, which is a critically low corrosion rate for satisfactory biodegradable cardiovascular stents, although zinc corrodes more quickly after 3 months and should be removed away from the artery <ref type="bibr">[70,</ref><ref type="bibr">71]</ref>. The corrosion rate for the AZ91 Mg Previous studies on biodegradable Mg alloys have shown that AZ91 Mg alloy corrodes at a rate of 1.1 mm/year [67], LAE442 at 2.8 mm/year <ref type="bibr">[68]</ref>, and WE43 at 3.9 mm/year <ref type="bibr">[69]</ref>. Zinc, another biodegradable metallic implant, corrodes at a rate of 0.2 mm/year, which is a critically low corrosion rate for satisfactory biodegradable cardiovascular stents, although zinc corrodes more quickly after 3 months and should be removed away from the artery <ref type="bibr">[70,</ref><ref type="bibr">71]</ref>. The corrosion rate for the AZ91 Mg alloy in our study obtained 1.3 mm/year, which is similar to the value reported for AZ91, i.e., 1.1 mm/year <ref type="bibr">[72]</ref>. However, following MAO treatment and composite coating, the corrosion rate of AZ91 significantly reduced to 1.2 and 0.00005 mm/year, respectively, which is considerably lower than the corrosion rate of widely studied Mg alloys such as LAE442 or WE43 for orthopedic implant applications. This result demonstrates that our composite coat prepared by the MAO/EPD method is promising for applications with a strict requirement for corrosion rate. In addition to reducing the corrosion rate, our strategy will also give bioactivity, i.e., osteoproductivity to Mg, which makes it a suitable platform for bone implantation and regeneration. Although our nanocomposite coating has been applied on AZ91 Mg alloy, this surface coating material (i.e., diopside-bredigite-FHA) with its coating method (i.e., MAO/EPD) can also be utilized on other biodegradable Mg alloys where a reduced corrosion rate, as well as an enhanced bioactivity, are required.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="4.">Conclusions</head><p>A nanocomposite made of diopside, bredigite, and fluoridated hydroxyapatite bioceramics were successfully coated on a biodegradable AZ91 Mg alloy using micro-arc oxidation followed by an electrophoretic deposition method. Following coating, the corrosion rate of AZ91 reduced from 0.57 &#177; 0.02 to 0.08 &#177; 0.01 mg/cm 2 /hr, which resulted in a reduced hydrogen-evolution in vivo. Improved bone regeneration (27 &#177; 1% to 56 &#177; 5%) with a reduced inflammatory response (42 &#177; 4% to 15 &#177; 3%) was detected in the tissue surrounding the composite coated implant compared to the uncoated ones. Hence, our composite coating strategy can be used on biodegradable Mg bone implants, where a reduced corrosion rate and improved implant osteointegration are required. Our results will help shed not only new light on the possible development of Mg-based orthopedic implants, i.e., bone plates, screws, pins, and nails, but also provide guidelines for the development and surface coating of Mg-based porous scaffolds for bone tissue engineering.</p></div></body>
		</text>
</TEI>