Abstract Variable stiffness robots may provide an effective way of trading-off between safety and speed during physical human–robot interaction. In such a compromise, the impact force reduction capability and maximum safe speed are two key performance measures. To quantitatively study how dynamic parameters such as mass, inertia, and stiffness affect these two performance measures, performance indices for impact force reduction capability and maximum speed of variable stiffness robots are proposed based on the impact ellipsoid in this paper. The proposed performance indices consider different impact directions and kinematic configurations in the large. Combining the two performance indices, the global performance of variable stiffness robots is defined. A two-step optimization method is designed to achieve this global performance. A two-link variable stiffness link robot example is provided to show the efficacy of the proposed method.
more »
« less
A Comparative Study on the Effect of Mechanical Compliance for a Safe Physical Human–Robot Interaction
Abstract In this paper, we study the effects of mechanical compliance on safety in physical human–robot interaction (pHRI). More specifically, we compare the effect of joint compliance and link compliance on the impact force assuming a contact occurred between a robot and a human head. We first establish pHRI system models that are composed of robot dynamics, an impact contact model, and head dynamics. These models are validated by Simscape simulation. By comparing impact results with a robotic arm made of a compliant link (CL) and compliant joint (CJ), we conclude that the CL design produces a smaller maximum impact force given the same lateral stiffness as well as other physical and geometric parameters. Furthermore, we compare the variable stiffness joint (VSJ) with the variable stiffness link (VSL) for various actuation parameters and design parameters. While decreasing stiffness of CJs cannot effectively reduce the maximum impact force, CL design is more effective in reducing impact force by varying the link stiffness. We conclude that the CL design potentially outperforms the CJ design in addressing safety in pHRI and can be used as a promising alternative solution to address the safety constraints in pHRI.
more »
« less
- Award ID(s):
- 1637656
- PAR ID:
- 10197583
- Date Published:
- Journal Name:
- Journal of Mechanical Design
- Volume:
- 142
- Issue:
- 6
- ISSN:
- 1050-0472
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract To reduce injury in physical human–robot interactions (pHRIs), a common practice is to introduce compliance to joints or arm of a robotic manipulator. In this paper, we present a robotic arm made of parallel guided beams whose stiffness can be continuously tuned by morphing the shape of the cross section through two four-bar linkages actuated by servo motors. An analytical lateral stiffness model is derived based on the pseudo-rigid-body model and validated by experiments. A physical prototype of a three-armed manipulator is built. Extensive stiffness and impact tests are conducted, and the results show that the stiffness of the robotic arm can be changed up to 3.6 times at a morphing angle of 37 deg. At an impact velocity of 2.2 m/s, the peak acceleration has a decrease of 19.4% and a 28.57% reduction of head injury criteria (HIC) when the arm is tuned from the high stiffness mode to the low stiffness mode. These preliminary results demonstrate the feasibility to reduce impact injury by introducing compliance into the robotic link and that the compliant link solution could be an alternative approach for addressing safety concerns of physical human–robot interactions.more » « less
-
Abstract In this paper, the realization of any specified planar Cartesian compliance for an object grasped by a compliant hand is addressed. The hands considered have 2 or more fingers for which each has 3 modulated elastic joints and predetermined link lengths. Geometric construction-based compliance synthesis procedures are developed. Using these procedures, a large set of compliant behaviors can be realized by a single hand simply by adjusting the configuration of each finger and by adjusting the joint stiffness (using variable stiffness actuation) of each finger joint.more » « less
-
Abstract In this article, the synthesis of any specified planar compliance with a serial elastic mechanism having previously determined link lengths is addressed. For a general n-joint serial mechanism, easily assessed necessary conditions on joint locations for the realization of a given compliance are identified. Geometric construction-based synthesis procedures for five-joint and six-joint serial mechanisms having kinematically redundant fixed link lengths are developed. By using these procedures, a given serial manipulator can achieve a large set of different compliant behaviors by using variable stiffness actuation and by adjusting the mechanism configuration.more » « less
-
Abstract Variable stiffness manipulators balance the trade-off between manipulation performance needing high stiffness and safe human-robot interaction desiring low stiffness. Variable stiffness compliant links provide a solution to enable this flexible manipulation function in human-robot co-working scenarios. In this paper, we propose a novel variable stiffness link based on discrete variable stiffness units (DSUs). A DSU is a parallel guided beam that can adjust stiffness discretely by changing the cross-sectional area properties of the hollow beam segments. The variable stiffness link (named Tri-DSU) consists of three tandem DSUs to achieve eight stiffness modes and a maximum stiffness change ratio of 31. To optimize the design, stiffness analysis of the DSU and Tri-DSU under various configurations and forces was performed by a derived theoretical model compared with finite element analysis (FEA). The analytical stiffness model is derived using the approach of serially connected beams and superposition combinations. It works not only for thin-walled flexure beams but also for general thick beam models. 3-D printed prototypes were built to verify the feature and performance of the Tri-DSU in comparison with the FEA and analytical model results. It’s demonstrated that our analytical model can accurately predict the stiffnesses of the DSU and Tri-DSU within a certain range of parameters. The developed variable stiffness link method and analytical model are extendable to multiple DSUs with different sizes and parameter configurations to achieve modularization and customization. The advantages of the stiffness change mechanism are rapid actuation, simple structure, and compact layout. These methods and results provide a new conceptual and theoretical basis for the development of new reconfigurable cobot manipulators, variable stiffness structures, and compliant mechanisms.more » « less