<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Thermal Simulation of a CPU Based on Model Order Reduction</title></titleStmt>
			<publicationStmt>
				<publisher></publisher>
				<date>10/11/2020</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10200426</idno>
					<idno type="doi"></idno>
					<title level='j'>IEEE MIT Undergraduate Research Technology Conference 2020</title>
<idno></idno>
<biblScope unit="volume"></biblScope>
<biblScope unit="issue"></biblScope>					

					<author>Jiang L. Ruttan K.</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[A previously developed thermal simulation technique based on model order reduction is applied to the simulation of a CPU. The approach is derived from proper orthogonal decomposition (POD) that projects the physical domain onto the POD space. It has been demonstrated that the developed approach offers an accurate thermal simulation of the CPU with a reduction in numerical degrees of freedom by several orders of magnitude compared to the direct numerical simulation (DNS). In addition, the technique has the capability of providing spatial resolution as fine as the direct numerical simulation for the CPU.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head>I. INTRODUCTION</head><p>With the miniaturization of devices and multifunctional chip design, CPUs and GPUs are being produced with an extremely high density of devices and complex interconnections. According to Moore's, law the number of transistors on semiconductor chips ha s increased, following an exponential curve and in recent decades this number has increased drastically <ref type="bibr">[1]</ref>. Along with the increase in the number of devices integrated into these chips, the power density has also increased substantially leading to undesirable temperature gradients and hot-spot formation <ref type="bibr">[2]</ref>. High-temperature gradients and hotspot formations have led to a degradation in the performance and reliability of CPU and GPU technology <ref type="bibr">[3]</ref>, <ref type="bibr">[4]</ref>. A more effective thermal management is thus vital to assist in protecting these chips and improving their performance. Since the beginning of integrated-circuit (IC) technology, more than 60 years ago, thermal simulations for semiconductor chips have been modeled using lumped RC thermal circuits that, although offering efficient thermal analysis, do not provide accurate thermal prediction and very often fitting/scaling factors are needed to improve the accuracy <ref type="bibr">[5]</ref>, <ref type="bibr">[6]</ref>. In addition, the poor resolution in the lumped elements of the RC thermal circuit models is incapable of capturing submicron-or nano-scale hot spots. To obtain high resolution and accurate prediction of the thermal distribution on the semiconductor chips, direct numerical simulations (DNSs) based on finite difference <ref type="bibr">[7]</ref>- <ref type="bibr">[9]</ref> or finite element methods <ref type="bibr">[10]</ref>- <ref type="bibr">[12]</ref> are usually needed. These approaches are however computationally time-consuming and are prohibitive for thermal simulation at the architecture level. We have recently developed an innovative thermal simulation approach based on model order reduction enabled by a datadriven learning process <ref type="bibr">[13]</ref>, <ref type="bibr">[14]</ref> for semiconductor ICs. The approach is able to offer a thermal prediction with the efficiency of the RC thermal model and the accuracy of the DNS. In this work, the approach is applied to the thermal simulation of a selected CPU at the architecture level.</p><p>The developed approach utilizes proper orthogonal decomposition (POD) <ref type="bibr">[15]</ref>, a projection-based reduced-order model that generates the basis functions (or modes hereafter) and projects the system partial differential equation(s) onto a functional space described by these modes <ref type="bibr">[13]</ref>- <ref type="bibr">[18]</ref>. The POD generates orthogonal modes from solution data of the DNSs in a domain subjected to the parametric variations. For heat transfer problems, these usually include variations of spatial/temporal power sources and boundary conditions (BCs). In this study, DNSs are performed in a n open-source computational platform known as FEniCS <ref type="bibr">[19]</ref>. The POD approach optimizes the modes from the thermal data specifically tailored to the geometry and parametric variations of the problem using a data -driven learning process. With the heat conduction equation projected to the POD modes, the approach can significantly reduce the degree of freedom (DoF) needed to accurately predict the thermal profile in the domain.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>II. BRIEF OVERVIEW OF PROPER ORTHOGONAL</head><p>DECOMPOSITION POD generates a set of modes from spatial/temporal thermal data accounting for the parametric variation. This is done by maximizing the mean square inner product of the thermal data and the modes in the domain &#61527;,</p><p>where &#9001; &#61655; &#9002; indicates an average. Each mode derived from this maximization process contains the maximum least squares (LS) information of the thermal behavior described by the thermal data <ref type="bibr">[20]</ref>, <ref type="bibr">[21]</ref>. The generated modes constitute an orthogonal functional space and can offer the best LS solution provided by the thermal data with a very small number of modes (i.e., DoF).</p><p>Applying variational calculus to (1), this problem is reformulated to the Fredholm equation,</p><p>where &#119929;(&#119909; &#8407;, &#119909; &#8407; &#8242; ) is a two-point correlation tensor given by</p><p>and &#61548; is the POD eigenvalue R represents the mean squared temperature captured by the corresponding POD mode. This decomposition process leads to an eigenvalue problem represented by (2) for R. Once the POD modes are found, the temperature &#119879;(&#119909; &#8407;, &#119905;) can be represented by a linear combination of the POD modes,</p><p>where M is the selected number of modes for the temperature solution and aj is the time-dependent coefficient for each mode.</p><p>To generate POD modes and eigenvalues more efficiently, the method of snapshots <ref type="bibr">[13]</ref>, <ref type="bibr">[14]</ref>, <ref type="bibr">[18]</ref> is applied.</p><p>Using the Galerkin projection method, a set of equations for aj is derived by projecting the heat conduction equation onto an eigenspace,</p><p>where k is the thermal conductivity, Pd the power density, &#61554; the </p><p>The crucial but time-consuming steps for developing a POD thermal model for thermal simulation of a CPU include (i) collection of thermal data from DNSs of the selected CPU, (ii) generation of the POD modes given in (2), and (iii) evaluation of the POD model parameters in <ref type="bibr">(7)</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>III. DEVELOPMENT OF POD MODELS FOR THERMAL SIMULATION OF A CPU</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>A. Thermal data collection</head><p>The Alpha EV6 processor shown in Fig. <ref type="figure">1</ref> [22] is selected for this work. Dynamic thermal simulations of the selected CPU are performed from a finite element simulator FEniCS [19] to collect thermal data that are needed for generating (or training) the POD modes. Adiabatic boundary conditions are applied to the surfaces of the chip except for the bottom of its substrate where the Robin boundary condition is used with ambient temperature taken as 0&#8451;. In Fig. <ref type="figure">1, A, B</ref> and<ref type="figure">C</ref> are the locations of the functional units where the uniform power pulses are applied. Each power source with a period of 3.333&#956;s represents an average, over 10k cycles at 3 GHz. Thermal simulation of the CPU structure with meshes of 129&#215;129&#215;7 is performed in FEniCS for 3ms. </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>B. Generation of POD mode and evaluation of model parameters</head><p>Once the thermal data are collected from the FEniC S simulation of the CPU, the method of snapshots <ref type="bibr">[13]</ref>, <ref type="bibr">[14]</ref>, <ref type="bibr">[18]</ref> is applied to solve (2) for POD modes and eigenvalues. The eigenvalue &#955; of each mode solved from (2) represents the mean squared temperature variations captured by the mode and thus reveals the importance of the mode. The eigenvalue for the collected data is displayed in Fig. <ref type="figure">2</ref> which shows that the eigenvalue decreases by 4 orders of magnitude from the first POD mode to the 3 rd mode and nearly 6 orders to the 5 th mode. This strongly indicates that the POD approach would provide very good accuracy with 3 to 5 modes. The eigenvalue curve becomes nearly flat beyond the 17 th mode due to the machine precision.</p><p>With the modes determined from (2), the model parameters, ci,j and gi,j in <ref type="bibr">(7)</ref> and power density in the POD space Ppod,i in (8) need to be evaluated to solve aj from the ODEs given in <ref type="bibr">(6)</ref>. The spatial and dynamic temperature on the CPU chip can then be determined from (4). It should be noted that the resolution of the temperature solved from the POD approach is determined by the POD modes &#120593; &#119894; whose resolution is identical to the DNS.  </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>IV. POD THERMAL SIMULATION OF THE SELECTED CPU</head><p>The developed POD approach presented in Section III is applied to the thermal simulation of the CPU structure given in Fig. <ref type="figure">1</ref>. The results are compared to the thermal FEniCS simulation of the same CPU. For a meaningful comparison, power sources and BCs a re identical between these 2 approaches. Power sources are located in the same functional units shown in Fig. <ref type="figure">1</ref>. The thermal profile of the CPU at t = 3ms (see Fig. <ref type="figure">4(a)</ref>) on the device layer, where the power sources are located, is illustrated in Fig. <ref type="figure">3</ref>.  <ref type="figure">1</ref>) is shown in Fig. <ref type="figure">4(a)</ref>. Although the one-mode POD provides the dynamic thermal prediction with a large LS error, the inclusion of 3 modes in the POD approach offers a good agreement with the FEniCS result. Results from these 2 approaches are indistinguishable when 5 modes are included. Such a small DoF can be achieved by the POD approach is clearly indicated by the substantial decrease in the eigenvalue shown in Fig. <ref type="figure">2</ref>. Spatial profiles of temperature on the device layer along the x and y directions (see Fig. <ref type="figure">1</ref>) reveal a similar capability to that of the POD approach, as shown in Figs. <ref type="figure">4(b</ref>) and 4(c) when comparing the POD and FEniCS simulation results. That is, the 3 -mode POD model provides an accurate prediction, compared to the FEniCS simulation. Also, the 5-mode POD results are in excellent agreement with FEniCS simulation results. In addition, the resolution derived from the POD models is as fine as that in FEniCS simulation.</p><p>V. CONCLUSION A reduced-order thermal model based on POD has been applied to the thermal simulation of a CPU structure subjected to several dynamic power sources. It is found the POD model with only 3 modes presents a thermal prediction of a CPU with good accuracy, compared to DNSs using the finite element method from FEniCS. With 5 modes included in the POD model, an excellent agreement with FEniCS can be achieved. This amounts to a reduction of numerical DoF by more than 4 orders of magnitude. In cases where finer resolutions are needed, the reduction in the DoF will be even greater. With such a small DoF, even smaller tha n the lumped thermal circuit model, the POD not only offers thermal prediction as accurate as that of the DNSs, but also provides resolution as fine as that of the DNSs. This is compared to the conventional thermal simulations at the architecture level where only a lower resolution can be achieved due to the simulation efficiency. The developed POD technique offers a n innovative approach that will offer accurate and efficient thermal simulations for CPUs and GPUs with a finer resolution that has been unattainable in the past.</p></div></body>
		</text>
</TEI>