Title: 3D projection electrophoresis for single-cell immunoblotting
Abstract

Immunoassays and mass spectrometry are powerful single-cell protein analysis tools; however, interfacing and throughput bottlenecks remain. Here, we introduce three-dimensional single-cell immunoblots to detect both cytosolic and nuclear proteins. The 3D microfluidic device is a photoactive polyacrylamide gel with a microwell array-patterned face (xy) for cell isolation and lysis. Single-cell lysate in each microwell is “electrophoretically projected” into the 3rddimension (z-axis), separated by size, and photo-captured in the gel for immunoprobing and confocal/light-sheet imaging. Design and analysis are informed by the physics of 3D diffusion. Electrophoresis throughput is > 2.5 cells/s (70× faster than published serial sampling), with 25 immunoblots/mm2device area (>10× increase over previous immunoblots). The 3D microdevice design synchronizes analyses of hundreds of cells, compared to status quo serial analyses that impart hours-long delay between the first and last cells. Here, we introduce projection electrophoresis to augment the heavily genomic and transcriptomic single-cell atlases with protein-level profiling.

 
more » « less
NSF-PAR ID:
10204303
Author(s) / Creator(s):
; ;
Publisher / Repository:
Nature Publishing Group
Date Published:
Journal Name:
Nature Communications
Volume:
11
Issue:
1
ISSN:
2041-1723
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    Class II major histocompatibility complex peptide (MHC‐IIp) multimers are precisely engineered reagents used to detect T cells specific for antigens from pathogens, tumors, and self‐proteins. While the related Class I MHC/peptide (MHC‐Ip) multimers are usually produced from subunits expressed inE. coli, most Class II MHC alleles cannot be produced in bacteria, and this has contributed to the perception that MHC‐IIp reagents are harder to produce. Herein, we present a robust constitutive expression system for soluble biotinylated MHC‐IIp proteins that uses stable lentiviral vector−transduced derivatives of HEK‐293T cells. The expression design includes allele‐specific peptide ligands tethered to the amino‐terminus of the MHC‐II β chain via a protease‐cleavable linker. Following cleavage of the linker, HLA‐DM is used to catalyze efficient peptide exchange, enabling high‐throughput production of many distinct MHC‐IIp complexes from a single production cell line. Peptide exchange is monitored using either of two label‐free methods, native isoelectric focusing gel electrophoresis or matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectrometry of eluted peptides. Together, these methods produce MHC‐IIp complexes that are highly homogeneous and that form the basis for excellent MHC‐IIp multimer reagents. © 2021 Wiley Periodicals LLC.

    This article was corrected on 19 July 2022. See the end of the full text for details.

    Basic Protocol 1: Lentivirus production and expression line creation

    Support Protocol 1: Six‐well assay for estimation of production cell line yield

    Support Protocol 2: Universal ELISA for quantifying proteins with fused leucine zippers and His‐tags

    Basic Protocol 2: Cultures for production of Class II MHC proteins

    Basic Protocol 3: Purification of Class II MHC proteins by anti‐leucine zipper affinity chromatography

    Alternate Protocol 1: IMAC purification of His‐tagged Class II MHC

    Support Protocol 3: Protein concentration measurements and adjustments

    Support Protocol 4: Polishing purification by anion‐exchange chromatography

    Support Protocol 5: Estimating biotinylation percentage by streptavidin precipitation

    Basic Protocol 4: Peptide exchange

    Basic Protocol 5: Analysis of peptide exchange by matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry

    Alternate Protocol 2: Native isoelectric focusing to validate MHC‐II peptide loading

    Basic Protocol 6: Multimerization

    Basic Protocol 7: Staining cells with Class II MHC tetramers

     
    more » « less
  2. Here we describe in detail the design, fabrication and operation of our automated high-throughput single cell microchip electrophoresis device with laser induced fluorescence detection. Our device features on-board integrated peristaltic pumps that generate flow directly within the microfluidic channels. Additionally, we have incorporated an optical fiber bridge that enables simultaneous fluorescence detection at two points of interest within the device without the need for additional optical components or detectors. The second detection spot is used to detect the intact cell immediately prior to lysis giving a signal at t = 0 s for each single-cell electropherogram. We can also use this signal to measure the absolute migration time of the separated analytes to confidently determine the identity of each peak. Finally, we demonstrate the application of our device for the measurement of intracellular nitric oxide (NO) levels in T-lymphocytes. Changes in NO levels within cells is associated with a number of chronic diseases including neurodegenerative, cardiovascular and cancers. We show that our system is capable of measuring NO levels under the following conditions: native, lipopolysaccharide stimulation, and inhibition of inducible nitric oxide synthase. It is our hope that the information and procedures described in this chapter may enable others to use or adapt our system for other analyses at the single cell level. 
    more » « less
  3. Abstract

    The ability to perform sophisticated, high-throughput optogenetic experiments has been greatly enhanced by recent open-source illumination devices that allow independent programming of light patterns in single wells of microwell plates. However, there is currently a lack of instrumentation to monitor such experiments in real time, necessitating repeated transfers of the samples to stand-alone analytical instruments, thus limiting the types of experiments that could be performed. Here we address this gap with the development of the optoPlateReader (oPR), an open-source, solid-state, compact device that allows automated optogenetic stimulation and spectroscopy in each well of a 96-well plate. The oPR integrates an optoPlate illumination module with a module called the optoReader, an array of 96 photodiodes and LEDs that allows 96 parallel light measurements. The oPR was optimized for stimulation with blue light and for measurements of optical density and fluorescence. After calibration of all device components, we used the oPR to measure growth and to induce and measure fluorescent protein expression inE. coli. We further demonstrated how the optical read/write capabilities of the oPR permit computer-in-the-loop feedback control, where the current state of the sample can be used to adjust the optical stimulation parameters of the sample according to pre-defined feedback algorithms. The oPR will thus help realize an untapped potential for optogenetic experiments by enabling automated reading, writing, and feedback in microwell plates through open-source hardware that is accessible, customizable, and inexpensive.

     
    more » « less
  4. Abstract

    Circulating tumor cells (CTCs) have been proven to have significant prognostic, diagnostic, and clinical values in early‐stage cancer detection and treatment. The efficient separation of CTCs from peripheral blood can ensure intact and viable CTCs and can, thus, give proper genetic characterization and drug innovation. In this study, continuous and high‐throughput separation of MDA‐231 CTCs from overlapping sized white blood cells (WBCs) is achieved by modifying inertial cell focusing with dielectrophoresis (DEP) in a single‐stage microfluidic platform by numeric simulation. The DEP is enabled by embedding interdigitated electrodes with alternating field control on a serpentine microchannel to avoid creating two‐stage separation. Rather than using the electrokinetic migration of cells which slows down the throughput, the system leverages the inertial microfluidic flow to achieve high‐speed continuous separation. The cell migration and cell positioning characteristics are quantified through coupled physics analyses to evaluate the effects of the applied voltages and Reynolds numbers (Re) on the separation performance. The results indicate that the introduction of DEP successfully migrates WBCs away from CTCs and that separation of MDA‐231 CTCs from similar sized WBCs at a highReof 100 can be achieved with a low voltage of magnitude 4 ×106 V/m. Additionally, the viability of MDA‐231 CTCs is expected to be sustained after separation due to the short‐term DEP exposure. The developed technique could be exploited to design active microchips for high‐throughput separation of mixed cell beads despite their significant size overlap, using DEP‐modified inertial focusing controlled simply by adjusting the applied external field.

     
    more » « less
  5. Abstract

    Microfluidic fluorescence‐activated cell sorters (μFACS) have attracted considerable interest because of their ability to identify and separate cells in inexpensive and biosafe ways. Here a high‐performance μFACS is presented by integrating a standing surface acoustic wave (SSAW)‐based, 3D cell‐focusing unit, an in‐plane fluorescent detection unit, and an SSAW‐based cell‐deflection unit on a single chip. Without using sheath flow or precise flow rate control, the SSAW‐based cell‐focusing technique can focus cells into a single file at a designated position. The tight focusing of cells enables an in‐plane‐integrated optical detection system to accurately distinguish individual cells of interest. In the acoustic‐based cell‐deflection unit, a focused interdigital transducer design is utilized to deflect cells from the focused stream within a minimized area, resulting in a high‐throughput sorting ability. Each unit is experimentally characterized, respectively, and the integrated SSAW‐based FACS is used to sort mammalian cells (HeLa) at different throughputs. A sorting purity of greater than 90% is achieved at a throughput of 2500 events s−1. The SSAW‐based FACS is efficient, fast, biosafe, biocompatible and has a small footprint, making it a competitive alternative to more expensive, bulkier traditional FACS.

     