We present a computational method, termed Wasserstein-induced flux (WIF), to robustly quantify the accuracy of individual localizations within a single-molecule localization microscopy (SMLM) dataset without ground- truth knowledge of the sample. WIF relies on the observation that accurate localizations are stable with respect to an arbitrary computational perturbation. Inspired by optimal transport theory, we measure the stability of individual localizations and develop an efficient optimization algorithm to compute WIF. We demonstrate the advantage of WIF in accurately quantifying imaging artifacts in high-density reconstruction of a tubulin network. WIF represents an advance in quantifying systematic errors with unknown and complex distributions, which could improve a variety of downstream quantitative analyses that rely upon accurate and precise imaging. Furthermore, thanks to its formulation as layers of simple analytical operations, WIF can be used as a loss function for optimizing various computational imaging models and algorithms even without training data.
more »
« less
Quantifying accuracy and heterogeneity in single-molecule super-resolution microscopy
Abstract The resolution and accuracy of single-molecule localization microscopes (SMLMs) are routinely benchmarked using simulated data, calibration rulers, or comparisons to secondary imaging modalities. However, these methods cannot quantify the nanoscale accuracy of an arbitrary SMLM dataset. Here, we show that by computing localization stability under a well-chosen perturbation with accurate knowledge of the imaging system, we can robustly measure the confidence of individual localizations without ground-truth knowledge of the sample. We demonstrate that our method, termed Wasserstein-induced flux (WIF), measures the accuracy of various reconstruction algorithms directly on experimental 2D and 3D data of microtubules and amyloid fibrils. We further show that WIF confidences can be used to evaluate the mismatch between computational models and imaging data, enhance the accuracy and resolution of reconstructed structures, and discover hidden molecular heterogeneities. As a computational methodology, WIF is broadly applicable to any SMLM dataset, imaging system, and localization algorithm.
more »
« less
- Award ID(s):
- 1653777
- PAR ID:
- 10205439
- Publisher / Repository:
- Nature Publishing Group
- Date Published:
- Journal Name:
- Nature Communications
- Volume:
- 11
- Issue:
- 1
- ISSN:
- 2041-1723
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Single-molecule localization microscopy (SMLM) breaks the optical diffraction limit by numerically localizing sparse fluorescence emitters to achieve super-resolution imaging. Spectroscopic SMLM or sSMLM further allows simultaneous spectroscopy and super-resolution imaging of fluorescence molecules. Hence, sSMLM can extract spectral features with single-molecule sensitivity, higher precision, and higher multiplexity than traditional multicolor microscopy modalities. These new capabilities enabled advanced multiplexed and functional cellular imaging applications. While sSMLM suffers from reduced spatial precision compared to conventional SMLM due to splitting photons to form spatial and spectral images, several methods have been reported to mitigate these weaknesses through innovative optical design and image processing techniques. This review summarizes the recent progress in sSMLM, its applications, and our perspective on future work. Graphical Abstractmore » « less
-
Osiński, Marek; Kanaras, Antonios G. (Ed.)Single-molecule localization microscopy (SMLM) strategies based on fluorescence photoactivation permit the imaging of live cells with subdiffraction resolution and the high-throughput tracking of individual biomolecules in their interior. They rely predominantly on genetically-encoded fluorescent proteins to label live cells selectively and allow the sequential single-molecule localization of sparse populations of photoactivated fluorophores. Synthetic counterparts to these photoresponsive proteins are limited to a few remarkable examples at the present stage, mostly because of the daunting challenges in engineering biocompatible molecular constructs with appropriate photochemical and photophysical properties for live-cell SMLM. Our laboratory developed a new family of synthetic photoactivatable fluorophores specifically designed for these imaging applications. They combine a borondipyrromethene (BODIPY) fluorophore and an ortho-nitrobenzyl (ONB) photocage in a single molecular skeleton. The photoinduced ONB cleavage extends electronic delocalization to shift bathochromically the BODIPY absorption and emission bands. As a result, these photochemical transformations can be exploited to switch fluorescence on in a spectral region compatible with bioimaging applications and allow the localization of the photochemical product at the single-molecule level. Furthermore, our compounds can be delivered and operated in the interior of live cells to enable the visualization of organelles with nanometer resolution and the intracellular tracking of single photoactivated molecules.more » « less
-
Abstract Super-resolution microscopy has revolutionized our ability to visualize structures below the diffraction limit of conventional optical microscopy and is particularly useful for investigating complex biological targets like chromatin. Chromatin exhibits a hierarchical organization with structural compartments and domains at different length scales, from nanometers to micrometers. Single molecule localization microscopy (SMLM) methods, such as STORM, are essential for studying chromatin at the supra-nucleosome level due to their ability to target epigenetic marks that determine chromatin organization. Multi-label imaging of chromatin is necessary to unpack its structural complexity. However, these efforts are challenged by the high-density nuclear environment, which can affect antibody binding affinities, diffusivity and non-specific interactions. Optimizing buffer conditions, fluorophore stability, and antibody specificity is crucial for achieving effective antibody conjugates. Here, we demonstrate a sequential immunolabeling protocol that reliably enables three-color studies within the dense nuclear environment. This protocol couples multiplexed localization datasets with a robust analysis algorithm, which utilizes localizations from one target as seed points for distance, density and multi-label joint affinity measurements to explore complex organization of all three targets. Applying this multiplexed algorithm to analyze distance and joint density reveals that heterochromatin and euchromatin are not-distinct territories, but that localization of transcription and euchromatin couple with the periphery of heterochromatic clusters. This work is a crucial step in molecular imaging of the dense nuclear environment as multi-label capacity enables for investigation of complex multi-component systems like chromatin with enhanced accuracy.more » « less
-
Single‐molecule localization microscopy (SMLM) precisely localizes individual fluorescent molecules within the wide field of view (FOV). However, the localization precision is fundamentally limited to around 20 nm due to the physical photon limit of individual stochastic single‐molecule emissions. Using spectroscopic SMLM (sSMLM) to resolve their distinct fluorescence emission spectra, individual fluorophore is specifically distinguished and identified, even the ones of the same type. Consequently, the reported photon‐accumulation enhanced reconstruction (PACER) method accumulates photons over repeated stochastic emissions from the same fluorophore to significantly improve the localization precision. This work shows the feasibility of PACER by resolving quantum dots that are 6.1 nm apart with 1.7 nm localization precision. Next, a Monte Carlo simulation is used to investigate the success probability of the PACER's classification process for distance measurements under different conditions. Finally, PACER is used to resolve and measure the lengths of DNA origami nanorulers with an inter‐molecular spacing as small as 6 nm. Notably, the demonstrated sub‐2 nm localization precision bridges the detection range between Förster resonance energy transfer (FRET) and conventional SMLM. Fully exploiting the underlying imaging capability can potentially enable high‐throughput inter‐molecular distance measurements over a large FOV.more » « less