Cardiomyocytes (CMs) and fibroblast cells are two essential elements for cardiac tissue structure and function. The interactions between them can alter cardiac electrophysiology and thus contribute to cardiac diseases, such as arrhythmogenesis. One possible explanation is that fibroblasts can directly affect cardiac electrophysiology through electrical coupling with CMs. Therefore, detecting the electrical activities in the CM-fibroblast network is vital for understanding the coupling dynamics among them. Current commercialized platforms for studying cardiac electrophysiology utilize planar microelectrode arrays (MEAs) to record the extracellular field potential (FP) in real-time, but the prearranged electrode configuration highly limits the measurement capabilities at specific locations. Here, we report a custom-designed MEA device with a novel micropatterning method to construct a controlled network of neonatal rat CMs (rCMs) and fibroblast connections for monitoring the electrical activity of rCM-fibroblast co-cultures in a spatially controlled fashion. For the micropatterning of the co-culture, surface topographical features and mobile blockers were used to control the initial attachment locations of a mixture of rCMs and fibroblasts, to form separate beating rCM-fibroblast clusters while leaving empty space for fibroblast growth to connect these clusters. Once the blockers are removed, the proliferating fibroblasts connect and couple the separate beating clusters. Using this method, electrical activity of both rCMs and human-induced-pluripotent-stem-cell-derived cardiomyocytes (iCMs) was examined. The coupling dynamics were studied through the extracellular FP and impedance profile recorded from the MEA device, indicating that the fibroblast bridge provided an RC-type coupling of physically separate rCM-containing clusters and enabled synchronization of these clusters.
more »
« less
Constant-potential environment for activating and synchronizing cardiomyocyte colonies with on-chip ion-depleting perm-selective membranes
In this study, an ion depleted zone created by an ion-selective membrane was used to impose a high and uniform constant extracellular potential over an entire ∼1000 cell rat cardiomyocyte (rCM) colony on-a-chip to trigger synchronized voltage-gated ion channel activities while preserving cell viability, thus extending single-cell voltage-clamp ion channel studies to an entire normalized colony. Image analysis indicated that rCM beating was strengthened and accelerated (by a factor of ∼2) within minutes of ion depletion and the duration of contraction and relaxation phases was significantly reduced. After the initial synchronization, the entire colony responds collectively to external potential changes such that beating over the entire colony can be activated or deactivated within 0.1 s. These newly observed collective dynamic responses, due to simultaneous ion channel activation/deactivation by a uniform constant-potential extracellular environment, suggest that perm-selective membrane modules on cell culture chips can facilitate studies of extracellular cardiac cell electrical communication and how ion-channel related pathologies affect cardiac cell synchronization. The future applications of this new technology can lead to better drug screening platforms for cardiotoxicity as well as platforms that can facilitate synchronized maturation of pluripotent stem cells into colonies with high electrical connectivity.
more »
« less
- Award ID(s):
- 1807551
- PAR ID:
- 10234865
- Date Published:
- Journal Name:
- Lab on a Chip
- Volume:
- 20
- Issue:
- 22
- ISSN:
- 1473-0197
- Page Range / eLocation ID:
- 4273 to 4284
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Abstract Electrical pacing/stimulations (EP) have been widely adopted to promote the maturation of hiPSC‐derived cardiomyocytes. However, there is a debate about their functions and effectiveness due to non‐optimized pacing conditions. Here, the effectiveness of EP (13 V cm−1, 2 ms in width, and 5 Hz frequency) on cardiac tissue beating mechanics are analyzed using digital image correlation (DIC). The cardiac tissues with and without EP at tissue culture time from day 2 to 11 (D2–D11) are characterized and compared. The results indicate EP decreased cardiac beating motion for ≈2–15 times, promote synchronization, and improve ion handling. A positive correlation between cardiac beating mechanics and ion handling is observed. DIC method can optimize chemical, mechanical, and electrical stimulation, which could help create more mature cardiac tissues.more » « less
-
Tolkacheva, Elena G (Ed.)Recent advances in human induced pluripotent stem cell (hiPSC)-derived cardiac microtissues provide a unique opportunity for cardiotoxic assessment of pharmaceutical and environmental compounds. Here, we developed a series of automated data processing algorithms to assess changes in action potential (AP) properties for cardiotoxicity testing in 3D engineered cardiac microtissues generated from hiPSC-derived cardiomyocytes (hiPSC-CMs). Purified hiPSC-CMs were mixed with 5–25% human cardiac fibroblasts (hCFs) under scaffold-free conditions and allowed to self-assemble into 3D spherical microtissues in 35-microwell agarose gels. Optical mapping was performed to quantify electrophysiological changes. To increase throughput, AP traces from 4x4 cardiac microtissues were simultaneously acquired with a voltage sensitive dye and a CMOS camera. Individual microtissues showing APs were identified using automated thresholding after Fourier transforming traces. An asymmetric least squares method was used to correct non-uniform background and baseline drift, and the fluorescence was normalized (ΔF/F0). Bilateral filtering was applied to preserve the sharpness of the AP upstroke. AP shape changes under selective ion channel block were characterized using AP metrics including stimulation delay, rise time of AP upstroke, APD30, APD50, APD80, APDmxr(maximum rate change of repolarization), and AP triangulation (APDtri= APDmxr−APD50). We also characterized changes in AP metrics under various ion channel block conditions with multi-class logistic regression and feature extraction using principal component analysis of human AP computer simulations. Simulation results were validated experimentally with selective pharmacological ion channel blockers. In conclusion, this simple and robust automated data analysis pipeline for evaluating key AP metrics provides an excellentin vitrocardiotoxicity testing platform for a wide range of environmental and pharmaceutical compounds.more » « less
-
null (Ed.)Scanning ion conductance microscopy (SICM) offers the ability to obtain nanoscale resolution images of the membranes of living cells. Here, we show that a dual-barrel nanopipette probe based potentiometric SICM (P-SICM) can simultaneously map the topography and surface potential of soft, rough and heterogeneously charged surfaces under physiological conditions. This technique was validated and tested by systematic studies on model samples, and the finite element method (FEM) based simulations confirmed its surface potential sensing capability. Using the P-SICM method, we compared both the topography and extracellular potential distributions of the membranes of normal (Mela-A) and cancerous (B16) skin cells. We further monitored the structural and electrical changes of the membranes of both types of cells after exposing them to the elevated potassium ion concentration in extracellular solution, known to depolarize and damage the cell. From surface potential imaging, we revealed the dynamic appearance of heterogeneity of the surface potential of the individual cell membrane. This P-SICM method provides new opportunities to study the structural and electrical properties of cell membrane at the nanoscale.more » « less
-
Anisotropic environmental signals or polarized membrane ion/solute carriers can generate spatially varying intracellular gradients, leading to polarized cell dynamics. For example, the directional migration of neutrophils, galvanotaxis of glioblastoma, and water flux in kidney cells all result from the polarized distribution of membrane ion carriers and other intracellular components. The underlying physical mechanisms behind how polarized ion carriers interact with environmental signals are not well studied. Here, we use a physiology-relevant, physics-based mathematical model to reveal how ion carriers generate intracellular ion and voltage gradients. The model can discern the contribution of individual ion carriers to the intracellular pH gradient, electric potential, and water flux. We discover that an extracellular pH gradient leads to an intracellular pH gradient via chloride-bicarbonate exchangers, whereas an extracellular electric field leads to an intracellular electric potential gradient via passive potassium channels. In addition, mechanical-biochemical coupling can modulate actin distribution and flow, creating a biphasic dependence of cell speed on water flux. Moreover, we find that F-actin interaction with NHE alone can generate cell movement, even when other ion carriers are not polarized. Taken together, the model highlights the importance of cell ion dynamics in modulating cell migration and cytoskeletal dynamics. Published by the American Physical Society2024more » « less