Title: Kinetic Spectroelectrochemical Assay for Uric Acid in Human Urine
Abstract

A spectroelectrochemical (SEC) assay for uric acid in human urine has been developed that is essentially reagent‐free and involves relatively short analysis times of ∼12 min per specimen using a single‐point standard addition approach. The SEC method was demonstrated to be selective for uric acid in human urine, avoiding interference through both the usual control parameters (electrolysis potential and measurement wavelength) and the relatively slow kinetics of a post‐electrolysis reaction involving the oxidation product. Results from the SEC analysis of a split set of human urine specimens were well correlated to those obtained using a standard high‐performance liquid chromatography method, suggesting the feasibility of clinical applications.

 
more » « less
NSF-PAR ID:
10238760
Author(s) / Creator(s):
 ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Electroanalysis
Volume:
33
Issue:
1
ISSN:
1040-0397
Page Range / eLocation ID:
p. 75-80
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    Objective.Pathological mineralizations form throughout the body and can be difficult to detect using conventional imaging methods. Color Doppler ultrasound twinkling highlights ∼60% of kidney stones with a rapid color shift and is theorized to arise from crevice microbubbles as twinkling disappears on kidney stones at elevated pressures and scratched acrylic balls in ethanol. Twinkling also sometimes appears on other pathological mineralizations; however, it is unclear whether the etiology of twinkling is the same as for kidney stones.Approach.In this study, five cholesterol, calcium phosphate, and uric acid crystals were grownin vitroand imaged in Doppler mode with a research ultrasound system and L7-4 transducer in water. To evaluate the influence of pressure on twinkling, the same crystals were imaged in a high-pressure chamber. Then, the effect of surface tension on twinkling was evaluated by imaging crystals in different concentrations of surfactant (1%, 2%, 3%, 4%) and ethanol (10%, 30%, 50%, 70%), artificial urine, bovine blood, and a tissue-mimicking phantom.Main results. Results showed that all crystals twinkled in water, with cholesterol twinkling significantly more than calcium phosphate and uric acid. When the ambient pressure was increased, twinkling disappeared for all tested crystals when pressures reached 7 MPa (absolute) and reappeared when returned to ambient pressure (0.1 MPa). Similarly, twinkling across all crystals decreased with surface tension when imaged in the surfactant and ethanol (statistically significant when surface tension <22 mN m−1) and decreased in blood (surface tension = 52.7 mN m−1) but was unaffected by artificial urine (similar surface tension to water). In the tissue-mimicking phantom, twinkling increased for cholesterol and calcium phosphate crystals with no change observed in uric acid crystals.Significance.Overall, these results support the theory that bubbles are present on crystals and cause twinkling, which could be leveraged to improve twinkling for the detection of other pathological mineralizations.

     
    more » « less
  2. Abstract

    Simultaneous analysis of ascorbic acid (AA), uric acid (UA), and dopamine (DA) is desirable as they are important biomarkers that coexist in biological fluids. Electrochemical detection of these molecules can be challenging as their oxidation peaks are poorly resolved at most unmodified electrodes. Modifications are typically necessary for analysis which increase cost and complicate fabrication. Herein, inexpensive and moldable polystyrene thermoplastic electrodes (PS TPEs), that can be used for simultaneous analysis of AA, DA, and UA, without surface modification, were presented. Electrode composition was optimized for conductivity, capacitance, and electrochemistry. Detection limits were 4, 0.9, and 4 μmfor AA, DA and UA respectively. PS TPEs were also challenged in urine; excellent recoveries (90–110 %) were seen for AA and UA. DA showed lower recoveries (82 % for 10 μmand 47 % for 5 μm), but in the future, higher recoveries can be achieved through design considerations and further material optimization.

     
    more » « less
  3. Abstract

    Glyphosate is a globally applied herbicide yet it has been relatively undetectable in‐field samples outside of gold‐standard techniques. Its presumed nontoxicity toward humans has been contested by the International Agency for Research on Cancer, while it has been detected in farmers’ urine, surface waters and crop residues. Rapid, on‐site detection of glyphosate is hindered by lack of field‐deployable and easy‐to‐use sensors that circumvent sample transportation to limited laboratories that possess the equipment needed for detection. Herein, the flavoenzyme, glycine oxidase, immobilized on platinum‐decorated laser‐induced graphene (LIG) is used for selective detection of glyphosate as it is a substrate for GlyOx. The LIG platform provides a scaffold for enzyme attachment while maintaining the electronic and surface properties of graphene. The sensor exhibits a linear range of 10–260µm, detection limit of 3.03µm, and sensitivity of 0.991 nAµm−1. The sensor shows minimal interference from the commonly used herbicides and insecticides: atrazine, 2,4‐dichlorophenoxyacetic acid, dicamba, parathion‐methyl, paraoxon‐methyl, malathion, chlorpyrifos, thiamethoxam, clothianidin, and imidacloprid. Sensor function is further tested in complex river water and crop residue fluids, which validate this platform as a scalable, direct‐write, and selective method of glyphosate detection for herbicide mapping and food analysis.

     
    more » « less
  4. ABSTRACT Objectives:

    Environmental enteric dysfunction (EED) may inhibit growth and development in low‐ and middle‐income countries, but available assessment methodologies limit its study. In rural Bangladesh, we measured EED using the widely used lactulose mannitol ratio (L:M) test and a panel of intestinal and systemic health biomarkers to evaluate convergence among biomarkers and describe risk factors for EED.

    Methods:

    In 539 18‐month‐old children finishing participation in a randomized food supplementation trial, serum, stool, and urine collected after lactulose and mannitol dosing were analyzed for biomarkers of intestinal absorption, inflammation, permeability and repair, and systemic inflammation. EED scores for each participant were developed using principal component analysis and partial least squares regression. Associations between scores and L:M and with child sociodemographic and health characteristics were evaluated using regression analysis.

    Results:

    EED prevalence (L:M > 0.07) was 39.0%; 60% had elevated acute phase proteins (C‐reactive protein >5 mg/L or α‐1 acid glycoprotein >100 mg/dL). Correlations between intestinal biomarkers were low, with the highest between myeloperoxidase and α‐1 antitrypsin (r= 0.33,P< 0.01), and biomarker values did not differ by supplementation history. A 1‐factor partial least squares model with L:M as the dependent variable explained only 8.6% of L:M variability. In adjusted models, L:M was associated with child sex and socioeconomic status index, whereas systemic inflammation was predicted mainly by recent illness, not EED.

    Conclusions:

    Impaired intestinal health is widespread in this setting of prevalent stunting, but a panel of serum and stool biomarkers demonstrated poor agreement with L:M. Etiologies of intestinal and systemic inflammation are likely numerous and complex in resource‐poor settings, underscoring the need for a better case definition with corresponding diagnostic methods to further the study of EED.

     
    more » « less
  5. Rationale

    Simple, affordable, and rapid methods for identifying the molecular weight (MW) distribution and macromolecular composition of polymeric materials are limited. Current tools require extensive solvent consumption, linear calibrations, and expensive consumables. A simple method for the determination of average MW (Mn,Mw) and chain end groups is demonstrated for synthetic homopolymer standards using direct injection electrospray ionization‐mass spectrometry (ESI‐MS) and an open‐sourced charge deconvolution (CDC) algorithm.

    Methods

    Five homopolymer standards in the 1–7 kDa MW range were analyzed using direct‐injection ESI‐MS on a quadrupole/time‐of‐flight mass spectrometer. The samples investigated, viz. two poly(ethylene oxide) (PEO) and two poly(styrene sulfonic acid) (PSS) standards with narrow polydispersity and one poly(d,l‐alanine) (pAla) standard with undefined polydispersity, were chosen to illustrate challenges with ESI‐MS quantitation. Using the UniDec program, weight average MWs (Mw) obtained from the charge‐deconvoluted spectra were compared to the reportedMwdata of the standards from size exclusion chromatography (SEC) measurements.

    Results

    The MW data derived for the PSS, PEO, and pAla standards agreed well with the corresponding reportedMwor MW range values. The method was able to provide MW, degree of polymerization (DP), and polydispersity index (PDI) information for polymers with narrow (PSS, PEO) as well as broader (pAla) molecular weight distribution; this feature provides an advantage over MW analysis via matrix‐assisted laser desorption/ionization (MALDI) for ESI‐compatible materials. PSS standards differing in average MW by only a few repeat units could be confidently distinguished. Additionally, the oligomeric resolution observed for all samples studied unveiled chain‐end information not available through chromatographic analysis.

    Conclusions

    Overall, the free and easy‐to‐use UniDec CDC algorithm provides a simple, alternative method to measuring MW and DP for polymeric materials without high solvent consumption, expensive ionization sources, or calibration curves. Information about the masses of individual oligomers and the possibility to further characterize these oligomers using tandem mass spectrometry and/or ion mobility techniques constitutes additional benefits of this approach vis‐à‐vis traditional MW and PDI elucidation through SEC.

     
    more » « less