<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Sampled-Data Observer Based Dynamic Surface Control of DelayedNeuromuscular Functional Electrical Stimulation</title></titleStmt>
			<publicationStmt>
				<publisher></publisher>
				<date>2022 October</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10275635</idno>
					<idno type="doi"></idno>
					<title level='j'>Sampled-Data Observer Based Dynamic Surface Control of Delayed Neuromuscular Functional Electrical Stimulation</title>
<idno></idno>
<biblScope unit="volume">84270</biblScope>
<biblScope unit="issue"></biblScope>					

					<author>Q. Zhang</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[Functional electrical stimulation (FES) is a potential technique for reanimating paralyzed muscles post neurological injury/disease. Several technical challenges including difficultyin measuring and compensating for delayed muscle activation levels inhibit its satisfactory control performance. In this paper, an ultrasound (US) imaging approach is proposed to measure delayed muscle activation levels under the implementation of FES. Due to low sampling rates of US imaging, a sampled data observer (SDO) is designed to estimate the muscle activation in a continuous manner. The SDO is combined with continuous-time dynamic surface control (DSC) approach that compensates for the electromechanical delay (EMD) in the tibialis anterior (TA) activation dynamics. The stability analysis based on the Lyapunov-Krasovskii function proves that the SDO-based DSC plus delay compensation (SDO-DSC-DC) approach achieves semi-global uniformly ultimately bounded (SGUUB)tracking performance. Simulation results on an ankle dorsiflexion neuromusculoskeletal system show the root mean square error (RMSE) of desired trajectory tracking is reduced by 19.77 % by using the proposed SDO-DSC-DC compared to the DSC-DC without the SDO. The findings provide potentials for rehabilitative devices, like powered exoskeleton and FES, to assist or enhance human limb movement based on the corresponding muscleactivities in real-time.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="1.">INTRODUCTION</head><p>Ankle dorsiflexion has a critical role in both human balance and walking <ref type="bibr">[1,</ref><ref type="bibr">2]</ref>. Therefore, a weakened function of ankle dorsiflexion impairs gait of affected persons. Drop foot is a typical symptom of weakened ankle dorsiflexion after cerebral vascular accidents and due to neurological disorders such as multiple sclerosis <ref type="bibr">[3,</ref><ref type="bibr">4]</ref>. Affected persons are unable to exhibit normal foot ground clearance during the swing phase, resulting in unnatural steppage gait to avoid tripping/falls <ref type="bibr">[5]</ref>. To correct drop foot, functional electrical stimulation (FES), which is an artificial technique to apply electrical potentials across skeletal muscles, can be applied on the tibialis anterior (TA) muscle. Since the earlier demonstration of FES to correct drop foot by Kantrowitz et al. <ref type="bibr">[6]</ref> and Liberson et al. <ref type="bibr">[7]</ref>, recent studies <ref type="bibr">[8,</ref><ref type="bibr">9]</ref> have started its efficacy on a larger clinical population. Typically the TA muscle is artificially activated during the swing phase using discrete sensors that either detect heel contact or leg inclination <ref type="bibr">[8]</ref>. The applied stimulation is fixed in amplitude or used a fixed pattern, e.g., trapezoid shape <ref type="bibr">[10]</ref>. Although these studies implement event triggered control, their inability to modulate stimulation amplitude is a major drawback, given the nonlinear and timevarying nature of FES.</p><p>Closed-loop FES control can provide robust performance and recreate precise and accurate functional movements, e.g., walking <ref type="bibr">[11,</ref><ref type="bibr">12]</ref>. However, electromechanical delay (EMD) imposes a major challenge in designing closed-loop FES control. To address EMD, nonlinear delay compensation (DC) control methods have recently been proposed <ref type="bibr">[13]</ref><ref type="bibr">[14]</ref><ref type="bibr">[15]</ref>. However, these control methods were designed by considering only the secondorder musculoskeletal dynamics, thereby neglecting the muscle activation dynamics. In <ref type="bibr">[16]</ref>, to account for the EMD and activation dynamics, a proportional-derivative (PD) controller using a dynamic surface control (DSC) error structure along with a DC term was developed. However, the control design was based on the assumption that the muscle activation variable is measurable in real-time. To address the hard-to-measure muscle activation dynamics, the authors then proposed a model-based estimator to predict the muscle activation levels <ref type="bibr">[17]</ref>. The model-based estimator was parameterized by using off-line system identification <ref type="bibr">[18]</ref> before performing the controller in tracking experiments, and there was no muscle physiological state feedback during the experiments.</p><p>Motivation exists to use direct measurement of FES-induced muscle activation and thus enable FES control based on a more accurate (third-order) musculoskeletal dynamics. Surface electromyography (sEMG) can used to represent muscle activation <ref type="bibr">[19]</ref>, but due to the presence of stimulation artifacts <ref type="bibr">[20]</ref> and noise interference, sEMG is an unreliable sensing technique for measuring muscle activation. Recently, ultrasound (US) imaging has been proposed as an alternative non-invasive technology to directly visualize skeletal muscle contractility. For example, Zhang et al. <ref type="bibr">[21]</ref> combined sEMG signal-induced and US imaging structural features-induced muscle activation levels to predict volitional isometric ankle dorsiflexion effort based on a modified Hill-type neuromuscular model. In <ref type="bibr">[22]</ref>, an adaptive speckle tracking algorithm to detect the quadriceps contraction strain by using US imaging was proposed to quantitatively evaluate muscle fatigue induced by FES. Compared to sEMG, the structural and functional features of US imaging are not affected by stimulation artifacts during FES.</p><p>In this paper, we propose to use US imaging to detect FESinduced muscle activation levels during an ankle trajectory tracking task. One of the main challenges is that US image generation and processing algorithms are computationally intensive. Most studies process US data offline to investigate muscle contractility changes due to FES, thus, the real-time use of US data to monitor muscle activity and aid control performance will be pioneering for FES control. Towards this goal, we assume that US data is available for closed-loop control, although at a much lower sampling frequency compared to other kinematic measurements, like signals from inertia measurement units (IMU) or incremental encoders. Therefore, given the US derived signal at a lower sampling rate, a sampled-measurement data based observer (SDO) is proposed to estimate the TA muscle activation level in a continuous manner, which meets the control requirements of a continuous state feedback.</p><p>Contributions on SDO design have been proposed in recent years. For example, Shen et al. <ref type="bibr">[23]</ref> proposed continuous observer for a class of multi-output nonlinear systems with multirate sampled and delayed output measurements, where the ob- servation error was proven to be globally exponentially stable. In our previous work <ref type="bibr">[24]</ref>, for a volitional ankle neuromusculoskeletal system, a continuous observer was designed based on multi-rate and delayed measurements from US imaging and IMUs. Further studies on SDO-based control for nonlinear system have also been proposed in recent years <ref type="bibr">[25]</ref><ref type="bibr">[26]</ref><ref type="bibr">[27]</ref>. In <ref type="bibr">[28]</ref>, the authors investigated the problem of output feedback stabilization with a linear continuous-discrete observer for a class of upper-triangular nonlinear system based on sampled and delayed single measurement. However, the aforementioned SDO-based control techniques mainly focused on regulation or stabilization task, and few contributions have been proposed for trajectory tracking task.</p><p>In this paper, the continuously estimated muscle activation levels from SDO, based on sampled US imaging measurement, is combined with a newly designed proportional-integral-derivative (PID) type DSC-DC controller to perform ankle dorsiflexion tracking task. The proposed SDO based PID-DSC-DC controller is compared with a PID-DSC-DC controller with the pure solution of muscle activation dynamics using the offline identified model parameters.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.">ANKLE DORSIFLEXION SYSTEM MODEL AND OB-SERVER MODEL</head><p>The dynamic model of the FES-induced ankle dorsiflexion movement, as shown in Fig. <ref type="figure">1</ref>, is given as</p><p>where J &#8712; R + is the unknown inertia term of the foot along the dorsiflexion rotation center axis, &#952; (t) &#8712; R, &#952; (t) &#8712; R, and &#952; (t) &#8712; R denote the angular position, angular velocity, and angular acceleration of the ankle dorsiflexion, respectively. The constant ankle equilibrium point is represented as &#952; eq &#8712; R + , which is the position that the foot is completely relaxed. The passive moment M v ( &#952; ) &#8712; R represents musculoskeletal viscosity, M e (&#952; ) &#8712; R represents musculoskeletal elasticity, and M g (&#952; ) = mgl sin( &#960; 2 + &#952;&#952; eq ) &#8712; R is the gravitational term acting on the ankle. The mass of the foot and the length from foot's center of mass to the ankle rotation center are denoted as m &#8712; R + and l &#8712; R + . The explicit definitions of the functions, M v ( &#952; ) and M e (&#952; ), can be obtained from <ref type="bibr">[29,</ref><ref type="bibr">30]</ref>. The term related to modeling uncertainties and external disturbance is denoted as</p><p>where the positive moment arm for the TA is denoted as r(&#952; ) &#8712; R + . F(&#952; , &#952; ) denotes the nonlinear relationship of muscle force-fascicle length and muscle forcefascicle velocity <ref type="bibr">[21]</ref>, and a(t) &#8712; [0, 1] is the muscle activation level whose dynamics is represented by the following continuous differential equation</p><p>In ( <ref type="formula">2</ref>), &#964; M &#8712; R + is the EMD caused by FES and is assumed to be known, T a &#8712; R + is the muscle activation decay constant, and d 2 (t) &#8712; R is the modeling uncertainties and disturbance in the muscle activation model. The normalized FES input u(t) &#8712; [0, 1] is due to the boundedness of the muscle stimulation. From <ref type="bibr">[31]</ref>, u(t) is modeled by a piece-wise linear function</p><p>where u min and u max &#8712; R &#8805;0 are the stimulation threshold and stimulation saturation, respectively, and &#363;(t) &#8712; R &#8805;0 is the stimulation current amplitude applied on the muscle.</p><p>To facilitate the control development and stability analysis, the musculoskeletal system dynamics in (1) are rewritten to a state space form as</p><p>where</p><p>&#915; . In the meanwhile, the measurement model is also given as</p><p>where angular position &#952; and velocity &#952; are measurable by using IMU or encoders with high sampling frequency, so they satisfy the requirement as feedback signals in real-time. The muscle activation a is measurable by using normalized variables, like pennation angle, fascicle length, and echogenicity from US imaging <ref type="bibr">[21]</ref>, but with much lower sampling frequency due to the computationally intensive image processing. The US imagingderived muscle activation signals are available at discrete instant t k , and {t k } is a monotonically increasing sequence and satisfies lim k&#8594;&#8734; t k = &#8734;. The sampling interval is assumed as a positive constant value T , including the elapsed time on US image generation and processing.</p><p>The following assumptions are given to finalize the observer and controller design.</p><p>Assumption 1: The nonlinear functions r(&#952; ) and F(&#952; , &#952; ) are assumed to be nonzero, positive, bounded functions, and their first-order and second-order time derivative exist and are bounded. Therefore, &#915; is also a nonzero, positive, and bounded function, and the first-order and second-order time derivative exist and are bounded.</p><p>Assumption 2: The modeling uncertainties and disturbance d 1 in (1) and d 2 in (2) are bounded, and their first-order and second-order time derivative exist and are bounded. So based on Assumption 1, d &#915;1 is also assumed to be bounded and its firstorder and second-order time derivative exist and are bounded.</p><p>Assumption 3: Based on Assumption 1, the term J &#915; is bounded and its first-order and second-order time derivative exist and are bounded.</p><p>Assumption 4: The desired ankle trajectory &#952; d &#8712; R and its time derivatives, &#952;d and &#952;d , are bounded.</p><p>To fulfill the goal of continuous muscle activation feedback, the proposed SDO for TA muscle activation in <ref type="bibr">(5)</ref> </p><p>where &#947; is a positive observation gain that will be subsequently constrained in stability analysis section.</p><p>is a constant value during the time interval t &#8712; [t k , t k+1 ), will be updated at every time point when the US imaging-derived normalized variable is available, and it is assumed to be bounded. Therefore, the observer model is of a hybrid nature with continuous and discrete variables. By taking the error between the continuous muscle activation dynamics in (4) and the SDO in ( <ref type="formula">6</ref>), the observation error dynamics is given as</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.">CONTROL DEVELOPMENT WITH SDO</head><p>The objective of this paper is to develop a trajectory tracking controller for FES-actuated ankle neuromusculoskeletal system that considers the continuous muscle activation and the EMD in the FES system. This will be achieved by designing a PID controller that uses a DSC framework along with a SDO to address hard-to-measure problem for muscle activation. In addition, a delay compensation (DC) term is added to address the FES-induced EMD problem in TA activation dynamics.</p><p>The trajectory tracking error for the proposed closed-loop control system is given as</p><p>where x d (t) &#8712; R is the desired continuously differentiable ankle dorsiflexion trajectory. For facilitating control design and stability analysis, the following two auxiliary error signals e 1 (t) and e 2 (t) &#8712; R are defined as</p><p>where &#945; 0 and &#945; 1 &#8712; R + are control gains and e 0 (t) is another auxiliary error signal to incorporate integral control, which is defined as</p><p>After taking the time derivative of e 2 (t), multiplying with J &#915; , and using ( <ref type="formula">4</ref>), ( <ref type="formula">8</ref>)-( <ref type="formula">10</ref>), we get</p><p>where f &#915; = M &#915;v + M &#915;e + M &#915;g . Assume the desired differentiable TA muscle activation signal as x 3d &#8712; R &#8805;0 , then the surface error is defined as</p><p>By adding and subtracting x 3d , x3 , and a DC term, e I &#8712; R, multiplied by a constant gain &#948; &#8712; R + , where e I (t) = t t-&#964; M u(s)ds in <ref type="bibr">(11)</ref>, the rearranged format of (11) can be given as</p><p>where the auxiliary signals H (e, e 1 , e 2 , e I , x d , &#7819;d , &#7821;d , t) &#8712; R and O (x d , &#7819;d , &#7821;d , &#915;, t) &#8712; R are defined as</p><p>where</p><p>. Furthermore, according to the Assumptions 1-4, the two auxiliary signals H and O can be bounded as</p><p>where </p><p>In the expression (13), the desired muscle activation is defined as <ref type="bibr">[17]</ref> x 3d = ke 2 = k &#279; + (&#945; 0 + &#945; 1 )ke + k&#945; 0 &#945; 1 e 0 <ref type="bibr">(17)</ref> where k = k 1 + k 2 + k 3 &#8712; R + , which implies a PID type signal with three different control gains, and the corresponding coefficients are defined as k p = (&#945; 0 + &#945; 1 )k, k d = k, and k i = k&#945; 0 &#945; 1 . By using the definition in <ref type="bibr">(17)</ref>, the formula (13) can be rewritten as</p><p>where S n = S&#948; e I , which is the augmented surface error that contains the DC term &#948; e I . By substituting ( <ref type="formula">12</ref>) and ( <ref type="formula">6</ref>), the time derivative of S n is given as</p><p>where &#966; = d dt (ke 2 ). The DC term e I is proposed to replace the delayed input in the muscle activation dynamics with a nondelayed input. By manipulating the non-delayed input, which is defined as the control law u(t) as</p><p>where &#946; &#8712; R + is a control gain, we can get the closed-loop surface error dynamics as below</p><p>4. STABILITY ANALYSIS Lemma 1. For any given positive definite matrix M &#8712; R n&#215;n , a positive scalar &#945;, and a vector function &#957;, the following Cauchy Schwarz inequality always holds as</p><p>The proof for this Lemma can be found in <ref type="bibr">[32]</ref>.</p><p>Theorem 1. Consider the neuromusculoskeletal system in (4) with a known input delay, by using the sampled US imagingbased observer for TA muscle activation in <ref type="bibr">(6)</ref> and control law in <ref type="bibr">(20)</ref>, the ankle dorsiflexion trajectory tracking error is ensured to be semi-globally uniformly ultimately bounded (SGUUB) provided that the observer gain &#947; and control gains &#945; 0 , &#945; 1 , k 1 , k 2 , &#946; , and &#948; satisfy the following sufficient conditions:</p><p>where &#964; M is the EMD, &#947; is the observation update gain, &#949; is a arbitrary positive constant, &#968; and &#954; are positive constant values defined in the subsequent stability analysis. Proof: Define an augmented vector w(t) &#8712; R 6 as w = e 0 , e 1 , e 2 , S n , &#949; 3 ,</p><p>and V 1 (w, t) can be bounded as</p><p>where &#955; and &#955; &#8712; R are two positive constants that is used to bound the Lyapunov functional candidate. Additionally, the Lyapunov-Krasovskii functional P &#8712; R + in ( <ref type="formula">23</ref>) is defined as</p><p>Taking the time derivative of ( <ref type="formula">23</ref>) and using ( <ref type="formula">7</ref>), ( <ref type="formula">9</ref>), ( <ref type="formula">10</ref>), <ref type="bibr">(18)</ref>, and (21) will result in the following expression</p><p>In the time interval t &#8712; [t k , t k+1 ), by substituting t t k &#949;3 (s)ds = &#949; 3 (t)&#949; 3 (t k ) to <ref type="bibr">(26)</ref>, and substituting u(t) in ( <ref type="formula">20</ref>) to <ref type="bibr">(26)</ref>, the following equation results in</p><p>Based on Young's inequality, Assumption 1-3, the following terms will be bounded as</p><p>where d2 &#8712; R + is the upper bound magnitude of d 2 (t), &#949; &#8712; R + is an arbitrary constant, and &#968; &#8712; R + is the upper bound of x3</p><p>. By applying the inequalities in ( <ref type="formula">28</ref>), boundary conditions in <ref type="bibr">(15)</ref>, and Lemma 1, ( <ref type="formula">27</ref>) can be further bounded as</p><p>After adding and subtracting (&#961;( z ) z ) 2 4k 2 and &#950; 2 4k 3 , and recall-</p><p>Construct the following auxiliary integral functional, which is also positive definite continuously differentiable, as</p><p>then (31) has a upper bound, which is given as</p><p>By taking the time derivative of (31), we have</p><p>Now, consider the following Lyapunov-Krasovskii functional candidate</p><p>where &#954; &#8712; R + is a constant. From ( <ref type="formula">30</ref>), <ref type="bibr">(32)</ref>, and (33), we can obtain</p><p>Recall e I (t) = t t-&#964; M u(s)ds, by using Lemma 1 again, we have</p><p>Then by multiplying -&#948; 2 2&#964; M &#946; 2 , the following inequality is given as</p><p>Therefore, <ref type="bibr">(30)</ref> </p><p>where</p><p>(38) can be written as</p><p>According to the definition of z(t) and w(t), (39) can be upper bounded as</p><p>, which is bounded by &#962; &#8712; R + , and &#958; ( z ) &#8712; R + is defined as</p><p>The expression (40) can be further bounded when it satisfies the condition &#958; -&#961; 2 ( z )</p><p>Given the definition of z and w, a set for initial condition of the augmented vector w(t) can be defined as</p><p>Based on the conditions in Theorem 1, &#958; ( z ) &#8805; 0 always holds and it can be lower bounded by a positive constant &#982; &#8804; &#958; ( z ) &#8712; R &#8805;0 . Recall the upper bound of V 1 in <ref type="bibr">(24)</ref>, the inequality in (40) can be rewritten as</p><p>where &#953; is a positive value and defined as &#953; = min{1, &#954;, &#982; &#955;</p><p>Therefore, for w(0) &#8712; F , the solution of the linear differential equation ( <ref type="formula">42</ref>) is given as</p><p>From (43), by providing the control gains &#945; 0 , &#945; 1 , k 1 , k 2 , &#946; , and &#948; , as well as the gain &#947; according to the sufficient conditions in Theorem 1, V (t) decays exponentially to a boundary &#962; &#953; . Because V &#8712; L &#8734; , the state variables in the augmented vector e 0 , e 1 , e 2 , S n , &#949; 3 , &#8730; P &#8712; L &#8734; . Recall the lower bound of V 1 in <ref type="bibr">(24)</ref>, further analysis can be done to show the ball radius of the w convergence is &#962; &#955; &#953; . Therefore, we can conclude that the closed-loop system is SGUUB. </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="5.">SIMULATION RESULTS</head><p>To validate the SDO-DSC-DC controller for the FESactuated ankle dorsiflexion neuromusculoskeletal system, simulations were conducted in Simulink with the fixed-step solver of 1 ms. As mentioned in Assumption 1, the signals &#952; and &#952; were sampled at very high frequency 1000 Hz, so they were directly used as feedback in the closed-loop system synchronously with the solver. Preliminary real-time US imaging generation and processing study has been performed in our lab, and the average elapsed time for obtaining US imaging-derived muscle activation signal was around 1 second. Therefore, the US imaging-derived TA activation measurement was sampled at 1 Hz in simulation. The model parameters for the second-order ankle dorsiflexion dynamic model ( <ref type="formula">1</ref>) and the first-order muscle activation dynamic model (2) used in the simulation were identified experimentally from an able-bodied subject based on the approach described in <ref type="bibr">[33]</ref>. Typically, EMD for human lower limbs varies between the range of 30 ms and 100 ms <ref type="bibr">[34]</ref>. In the controller design, EMD was set to be a constant 50 ms, while in the ankle dynamic model it was defined to be a time-varying value between 35 ms and 65 ms with the purpose to test the robustness of the proposed SDO-DSC-DC controller. The modeling uncertainties and external disturbance d 1 (t) in (1) and d 2 (t) in (2) are defined as a zero mean white noise with an standard deviation of 1 Nm and 0.5.</p><p>According to <ref type="bibr">[35]</ref>, the ankle dorsiflexion motion range during swing phase mainly located between 0 &#176;and 20 &#176;(the toe up direction is positive). Based on this, the desired ankle dorsi- Random values between 0 and 1 were generated in Simulink every second to mimic the discrete muscle activation measurement coming from US imaging. Fig. <ref type="figure">3</ref> shows the update term in <ref type="bibr">(6)</ref>, which remains as a constant during the time interval of two successive US imaging-derived muscle activation measurements. In the simulation, the estimated muscle activation by using the SDO and the pure solution of muscle activation dynamics with US imaging-derived updated initial condition are shown in Fig. <ref type="figure">2</ref> (c). It is obvious that the muscle activation level is significantly lower by using SDO compared to the muscle activation calculated from sole dynamics. The findings imply that the proposed SDO-DSC-DC can achieve superior ankle dorsiflexion trajectory tracking performance, and at the same time reduce the muscle activation level, which is beneficial to suppress the undesired effects caused by muscle fatigue. Further investigation is needed to test the performance of muscle fatigue suppression by using the proposed control method.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="6.">CONCLUSION</head><p>In this paper, we proposed a trajectory tracking controller for a neuromusculoskeletal system with input delays and discrete muscle activation measure. A SDO was designed to continuously estimate the muscle activation level based on the discrete US imaging-derived muscle activation signal, while DSC was used to avoid the "explosion of terms" during the controller design. In addition, a DC technique was used to deal with the FESinduced input delay. Stability analysis was performed by using a Lyapunov approach, which proved the SGUUB tracking performance. Simulation results showed the superior trajectory tracking performance by using SDO-DSC-DC compared to DSC-DC using only the solution of activation dynamics. The future work will investigate the observation of muscle fatigue and muscle activation at the same time based on the proposed SDO, as well as the experimental implementation and verification for the proposed observer-based DSC-DC controller on human ankle joint.</p></div></body>