<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Hyperspectral Raman Imaging Using a Spatial Heterodyne Raman Spectrometer with a Microlens Array</title></titleStmt>
			<publicationStmt>
				<publisher></publisher>
				<date>08/01/2020</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10283994</idno>
					<idno type="doi">10.1177/0003702820906222</idno>
					<title level='j'>Applied Spectroscopy</title>
<idno>0003-7028</idno>
<biblScope unit="volume">74</biblScope>
<biblScope unit="issue">8</biblScope>					

					<author>Ashley Allen</author><author>Abigail Waldron</author><author>Joshua M. Ottaway</author><author>J. Chance Carter</author><author>S. Michael Angel</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[A new hyperspectral Raman imaging technique is described using a spatial heterodyne Raman spectrometer (SHRS) and a microlens array (MLA). The new technique enables the simultaneous acquisition of Raman spectra over a wide spectral range at spatially isolated locations within two spatial dimensions ( x, y) using a single exposure on a charge-coupled device (CCD) or other detector types such as a complementary metal-oxide semiconductor (CMOS) detector. In the SHRS system described here, a 4×4mm MLA with 1600, 100µm diameter lenslets is used to image the sample, with each lenslet illuminating a different region of the SHRS diffraction gratings and forming independent fringe images on the CCD. The fringe images from each lenslet contain the fully encoded Raman spectrum of the region of the sample “seen” by the lenslet. Since the SHRS requires no moving parts, all fringe images can be measured simultaneously with a single detector exposure, and in principle using a single laser shot, in the case of a pulsed laser. In this proof of concept paper, hyperspectral Raman spectra of a wide variety of heterogeneous samples are used to characterize the technique in terms of spatial and spectral resolution tradeoffs. It is shown that the spatial resolution is a function of the diameter of the MLA lenslets, while the number of spatial elements that can be resolved is equal to the number of MLA lenslets that can be imaged onto the SHRS detector. The spectral resolution depends on the spatial resolution desired, and the number of grooves illuminated on both diffraction gratings by each lenslet, or combination of lenslets in cases where they are grouped.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Introduction</head><p>The spatial heterodyne Raman spectrometer (SHRS) is a fixed grating, Fourier transform interferometer with high light throughput, a wide field of view (FOV), and high spectral resolution. Unlike conventional, dispersive gratingbased spectrometers, the resolving power of the SHRS is not strongly dependent upon entrance aperture size. The SHRS also has no moving parts, and SHS emission spectrometers have been built using monolithic optical techniques, which makes the system robust and tolerant of vibrations. <ref type="bibr">1</ref> The large acceptance angle of the SHRS makes it amenable to applications involving the collection of light from diffuse sources, or for remote Raman at intermediate ranges <ref type="bibr">2</ref> where image jitter can affect the reproducibility when using a slit-based spectrometer. <ref type="bibr">3</ref> Applications such as remote Raman, transmission Raman, micro-Raman, fiber coupled Raman, spatially offset Raman, and Raman imaging may benefit from the larger viewing area of the SHRS. This paper describes an innovative way to perform two-dimensional (2D) Raman chemical imaging using the SHRS, which takes advantage of the large viewing area of the SHS.</p><p>Raman imaging is useful to characterize heterogeneous materials by measuring chemical properties in multiple spatial dimensions. <ref type="bibr">4</ref> A Raman image can be 2D, where the intensity of a single Raman band is mapped across the heterogenous sample, or hyperspectral, where multiple Raman band intensities are acquired for each spatial point on the sample. Early Raman microprobes were scanning instruments, where the laser mapped the sample surface to generate the hypercube of data, either point-by-point or by line scanning the laser across the sample. <ref type="bibr">5</ref> For point-by-point scanning, the laser is focused to a small spot and the sample is raster scanned through the laser beam, collecting the entire Raman spectrum at each point. <ref type="bibr">6</ref> In line scanning, the laser is focused to a thin line, using cylindrical optics. The illumination line on the sample is parallel to the entrance slit of a dispersive spectrometer so that a Raman spectrum is acquired on each row of a 2D array detector. <ref type="bibr">7</ref> Wide field Raman imaging measures all points on the sample simultaneously using an expanded laser spot, while a single Raman band is measured using a tunable filter to acquire a 2D Raman image. The hyperspectral image is built up by measuring Raman images as the filter is tuned to different wavelengths corresponding to Raman bands. Various types of filters have been used in this method, including dielectric filters, acousto optic, and liquid crystal tunable filters. <ref type="bibr">[8]</ref><ref type="bibr">[9]</ref><ref type="bibr">[10]</ref><ref type="bibr">[11]</ref><ref type="bibr">[12]</ref><ref type="bibr">[13]</ref><ref type="bibr">[14]</ref><ref type="bibr">[15]</ref><ref type="bibr">[16]</ref> Fiber optic arrays have been used for hyperspectral Raman imaging, where spatial and spectral information were simultaneously acquired. However, the number of spatial points demonstrated using a fiber array is low and the fiber fill factor is also low. <ref type="bibr">17</ref> Here, we describe a new hyperspectral Raman imaging technique using a microlens array (MLA) in a confocal imaging arrangement with an SHRS. The MLA is an array of microlenses, with diameters ranging from 10 mm to 2 mm, where each views a different spot on the sample. The use of MLAs for confocal microscopy has been described previously; Dwight and Tkaczyk reported fluorescence microscopy using an MLA with a prism to collect fluorescence data with $20 nm spectral resolution. <ref type="bibr">18</ref> This technique has not previously been applied to Raman. The MLA-SHRS instrument described in this paper allows the measurement of a hyperspectral Raman image, covering the entire Raman fingerprint range (e.g., $2500 cm &#192;1 ) in a single measurement. In this proof of concept paper, approximately 550 spatially isolated Fizeau fringe patterns are simultaneously imaged; our data indicate that many thousands of points (e.g., $10 000) can be simultaneously imaged while maintaining a large spectral range, in an optimized instrument.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Experimental</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Illumination</head><p>The sample was excited by a continuous wave (CW) 532 nm neodymium-doped yttrium aluminum garnet (Nd:YAG) laser (OptoEngine, MLL-FN-532-300mW) in an epi-illumination backscatter geometry. The laser beam diameter was 2.2 mm. The laser was directed to the sample on the axis of the SHRS spectrometer, using a 25 mm diameter, 550 nm long-pass dichroic mirror (ThorLabs, DMLP550), and was focused on the sample by the MLA (Suss MicroOptics, part no. 19-00055), with each lenslet focusing the laser to a separate small spot, with an airy disk of $20 mm, to give an array of 484 laser spots on the sample. The laser power focused by each separate lenslet was $300 mW at the sample. The sample was located at the focal point of the f/16 MLA, a distance of 1.5 mm. The fused silica MLA is 4 &#194; 4 mm overall size with 1600, 100 mm diameter circular lenslets, packed in a square grid, with a fill factor close to 80%. The MLA has chromium apertures that block light between the lenslets to prevent crosstalk, and it is antireflection coated at 780 nm. The flat surface was turned opposite the sample, in the direction of the spectrometer.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Light Collection</head><p>Raman scattered light from the sample was collected by the MLA and collimated, each lenslet having a unique spatially isolated FOV on the sample from the others, producing its own separate collimated beam. A relay lens (Nikon AF NIKKOR 80-200 mm f/4.5-5.6) was used to image the back surface of the MLA onto the SHRS gratings. The distance used depended on the desired magnification, 4&#194;, 8&#194;, or 10&#194;, of the MLA at the SHRS gratings. The magnification was used to change the number of lenslets measured and the resolving power for single lenslets. A 4 mm diameter spatial filter, located at the focal point of the relay lens, minimized crosstalk between lenslets, as described by Tiziani et al. <ref type="bibr">19,</ref><ref type="bibr">20</ref> </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Spatial Heterodyne Spectrometer</head><p>The SHRS, similar to ones described previously, is equipped with a 25 mm N-BK7 non-polarizing 50:50 cube beamsplitter (ThorLabs, BS013) and a pair of 300 lp/mm gratings, blazed at 500 nm (Edmund Optics, #64-403). <ref type="bibr">21,</ref><ref type="bibr">22</ref> An iris at the input aperture limits the size of the illuminated area on the gratings to $14 mm. The SHRS was equipped with two 532 nm long-pass filters (Semrock RazorEdge, LP03-532RE-25), a 550 nm long-pass filter (ThorLabs, FEL0550), and a 581 nm short-pass filter (Knight Optical, 581FDS25) to remove strong laser scatter and to limit the total spectral range (bandpass) allowed into the spectrometer. A fused silica 105 mm focal length, f/4.5 lens (Coastal Optical Systems, Inc., UV-MICRO-APO 111032) imaged the grating faces to produce the fringe image with 1.17&#194; magnification onto a thermoelectrically cooled, back-illuminated, UV-enhanced charge-coupled device (CCD) detector with 2048 &#194; 512, 13.5 mm pixels (Princeton Instruments, PIXIS-2048 2KBUV). A spatial filter placed one focal length behind the imaging lens was used to block higher grating orders. Images were acquired in Lightfield 4.10 software with 100 kHz ADC gain high and in the low noise setting.</p><p>The CCD was cooled to -70 C. For the Raman image in Fig. <ref type="figure">8</ref>, a CMOS detector with 5544 &#194; 3694, 2.4 mm pixels was used (QHYCCD, QHY183M).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Spectral Calculations, Fast Fourier Transform</head><p>All spectral calculations were done using Matlab (The MathWorks, v.R2016a). To obtain Raman spectra from the fringe images, a region of interest is selected, and the rows are summed, in the vertical direction, to give an interferogram superimposed on a background signal, and the background is removed by subtracting a fitted polynomial curve. The corrected interferogram is then Fourier transformed using the Matlab FFT function, to reveal the Raman spectrum, plotted as magnitude versus wavenumber. For 2D SHRS measurements, one grating was slightly tilted from the vertical to produce a wavenumber dependent fringe rotation that reduces the ambiguity of bands above and below the Littrow wavenumber.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Sample Preparation</head><p>Several bilayer mixed sample pellets were prepared using a 13 mm pellet die (Carver, catalog #3619). Samples were prepared with the intention of keeping the constituents spatially separated so that different samples were viewed by different lenslets of the MLA. The samples included a diamond (Wards Science, kit #458200) pressed into a potassium perchlorate (Alfa Aesar #11630, 99% anhydrous) pellet, a sodium sulfate (Sigma Aldrich, 239313)/potassium perchlorate pellet, a sodium nitrate (Sigma Aldrich, 347663)/potassium perchlorate pellet, and an acetaminophen (Sigma-Aldrich, A7085)/ ammonium nitrate (Aldrich, 256064) pellet.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Results and Discussion</head><p>The SHRS is a dispersive interferometer that uses two stationary reflective diffraction gratings. Operation of the SHRS has been described previously. <ref type="bibr">[21]</ref><ref type="bibr">[22]</ref><ref type="bibr">[23]</ref> Briefly, collimated signal enters the input aperture of the SHRS where it is split into two beams by a 50:50 beamsplitter. These two beams strike the stationary diffraction gratings which are tilted at an angle, y L , such that one particular wavelength, the Littrow wavelength, L , is retroreflected along the incident light path and recombines at the beamsplitter. Heterodyning in the interferometer occurs at the Littrow wavelength, so light at wavelengths longer or shorter than L are diffracted from the gratings at an angle to the optical axis, resulting in crossed wavefronts, inducing a spatial phase shift, and generating a wavelength dependent, vertical interference pattern on the array detector. The intensity of the pattern is a function of position x on the detector, given by Eq. 1</p><p>where B(s) is the input spectral intensity at wavenumber s, and the Fourier transform (FT) of I(x) recovers the encoded Raman spectrum. The fringe frequency on the detector is given by Eq. 2, where f is in fringes/cm, s L is the Littrow wavenumber, and s is the wavenumber of interest. 23</p><p>According to Eq. 2, emission lines above or below the Littrow wavelength show identical fringe patterns, leading to degenerate lines (i.e., line overlap). This degeneracy can be removed by tilting one of the gratings vertically or rotating it about the optical axis, which induces a rotation to the Fizeau fringe pattern, in opposite directions above and below Littrow. <ref type="bibr">22,</ref><ref type="bibr">23</ref> In this case, a 2D Fourier transform can be used to recover spectra above and below the Littrow wavelength, unambiguously. This is very useful for doubling the spectral range of the SHRS.</p><p>Unlike a dispersive spectrometer, which requires a physical slit to control the spectral resolution, the SHRS, like other Fourier transform interferometers, does not. Rather, the resolving power, R, of the SHRS, given by Eq. 3 is equal to the total number of grooves illuminated on both gratings where W is the illuminated width of one grating and D is the grating line density. <ref type="bibr">23</ref> </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>R &#188; 2WD &#240;3&#222;</head><p>This allows the SHRS to employ a large entrance aperture, greatly increasing the throughput of the system, which is advantageous for measuring extended sources in situations where a large laser spot might be used to reduce sample damage; when using a large diameter optical fiber to deliver light to the spectrometer; or other applications where large sample areas need to be measured, such as the imaging technique described in this paper.</p><p>In the SHRS used for these studies (see Fig. <ref type="figure">1a</ref>), the width of the input beam at the gratings is $14 mm, so the theoretical resolving power, R, is 8400, giving a theoretical resolution of $2 cm &#192;1 for a 1000 cm &#192;1 Raman band, using 532 nm excitation. This spectral resolution is about the same as a Kaiser Holospec f/1.8 spectrometer, with a 25 mm slit. <ref type="bibr">24</ref> The measured spectral resolution of the SHRS was $7 cm &#192;1 , using a low-pressure Hg lamp source (Ocean Optics, Hg-1). The measured resolution of the SHRS is very sensitive to alignment of focusing optics, likely the cause for the lower the expected resolution.</p><p>The illuminated width of the CCD is 14.8 mm, $1100 pixels, so the theoretical spectral range of the SHRS, based on the Nyguist criteria of two pixels per wavelength, is $1155 cm &#192;1 . The spectral range can be doubled to $2310 cm &#192;1 using the 2D Fourier transform technique described above. The throughput of the SHS is larger than a conventional dispersive spectrometer of comparable spectral resolution, from the combination of a large aperture and wide FOV. The maximum, resolution-limited solid angle FOV of the SHRS is related to the resolving power by Eq. 4. <ref type="bibr">23</ref> The solid angle FOV for the spectrometer used in the studies presented here is 7.5 &#194; 10 &#192;4 sr, corresponding to a full acceptance angle of $1.6</p><p>Figure <ref type="figure">2a</ref> shows how the MLA is imaged onto the face of the gratings by the relay lens. The 40 &#194; 40 MLA used in this work is shown in Fig. <ref type="figure">2b</ref>. Light from each MLA lenslet travels in a unique path through the interferometer, each providing its own independent spatially isolated Fizeau fringe pattern. In Fig. <ref type="figure">2a</ref>, the light path for two lenslets is illustrated. Each of the 1600 MLA lenslets (Fig. <ref type="figure">2b</ref>) has the same focal length, and the sample is placed one focal length from the MLA. The laser is focused by each MLA lenslet to a small spot on the sample. Scattered Raman light is collected by the MLA lenslets to produce an array of collimated beams, one for each lenslet. As long as the beams generated by the f/16 MLA lenslets are collimated within the acceptance angle of the SHRS, interference occurs producing high contrast fringe patterns. The relay lens is positioned to image the back surface of the MLA onto the SHRS gratings. A spatial filter, located at the focal point of the relay lens, prevents crosstalk between the FOV of MLA lenslets, as described by Tiziani et al. <ref type="bibr">19,</ref><ref type="bibr">20</ref> Another lens inside the SHRS images the grating face, i.e., the focused MLA lenslet image, onto a CCD detector. Figure <ref type="figure">2c</ref> is the Raman image of the sulfur pellet in Fig. <ref type="figure">2d</ref>, which shows almost all of the 1600 MLA lenslets and the ridge detail of the sulfur pellet that is retained in the MLA-SHRS image. However, with the CCD used for this work, individual lenslet Fizeau fringes could not be resolved. This is a limitation of the number of pixels in our detector array, which, at only eight pixels per lenslet, was insufficient to resolve fringes. Resolving all 1600 lenslet fringe images would require a CCD with much smaller pixels.</p><p>Figure <ref type="figure">1b</ref> shows Raman spectra measured using the MLA-SHRS system shown in Fig. <ref type="figure">2</ref>. Each detector image with its corresponding spectrum shows the individual lenslets that are viewed and the position of each sample within the FOV. The samples consisted of a series of bilayer pellets that were illuminated at the interface between the two constituents, so that both solids were within the FOV of the instrument. The imaged area shown was about 12 lenslets wide by about five lenslets tall, giving a measured sample area of 1.32 mm &#194; 0.55 mm. The number of lenslets viewed was limited by the spectral resolution of the grating used in these studies-these limitations are discussed in a later section. For the spectra shown, the MLA was not used for imaging, rather, the signal from all 60 lenslets was summed to produce the spectrum, which represents the mean Raman spectra over the total area measured. The measured resolution was $7 cm &#192;1 for the potassium perchlorate/diamond and sodium sulfate/potassium perchlorate samples. The resolution was slightly lower, $8-9 cm &#192;1 , for the sodium nitrate/potassium perchlorate and an acetaminophen/ammonium nitrate pellets, because the imaging magnification was slightly larger (8&#194;) than in the former (10&#194;). The spectral range for these spectra is $1150 cm &#192;1 , consistent with the theoretical value. Raman spectra using fringe images from the individual lenslets, for each of the samples shown in Fig. <ref type="figure">1b</ref>, are described in the following.</p><p>Figure <ref type="figure">3</ref> shows how MLA-SHRS lenslet spectra are recovered for a diamond sample. The signal is collected and shown as an array of fringe images (upper left image), one from each lenslet, on the detector. The fringe image cross-section (upper right), produced by summing pixels vertically in each column, for a selected lenslet fringe image (shown by white box), shows an interferogram superimposed on a large background signal. The background is removed by subtracting a fitted polynomial from the cross-section. This subtraction procedure does not account for the variation of the signal intensity across the interferogram. The spectrum is obtained by taking the one-dimensional (1D) Fourier transform of the resulting interferogram. The resulting diamond Raman spectrum has a spectral resolution of $41 cm &#192;1 , which is lower than the 6 cm &#192;1 achieved for the diamond sample shown in Fig. <ref type="figure">1b</ref>(i), because of the lower number of grooves illuminated by a single lenslet on the grating. Due to coherence effects inside the interferometer, each MLA lenslet interferogram does not have its own location of zero path difference. This results in a decrease of coherence across the grating face and limits the horizontal size of the grating that can give high fringe contrast across the entire grating face. A solution to this issue would be to use several smaller gratings, each with its own center burst position, or use a compensator plate, shaped to reduce the optical path difference across the grating.</p><p>A 2D Fourier transform of each lenslet Fizeau fringe pattern can be used to differentiate spectra on either side of the Littrow (i.e., the heterodyne) wavelength and approximately double the spectral range, provided the fringe pattern has a sufficient rotation to induce a phase shift, u, along the y-axis. This is accomplished by either tilting or rotating one of the gratings with respect to the other grating in the SHRS. An expansion of the bracketed term in Eq. 1 to include this y-axis phase shift term is shown in Eq. 5 <ref type="bibr">23</ref> I&#240;x, y&#222;</p><p>Figure <ref type="figure">4</ref> shows a 2D interferogram for an acetaminophen sample (top left), cropped to show clearly the crossed fringe pattern, for a 4 &#194; 4 section of lenslets. The Littrow wavenumber of the SHRS was set to $1000 cm &#192;1 , indicated by s L in the spectra, so Raman bands above and below Littrow rotate the fringes in opposite directions. Note the strong center burst in region b of the Raman fringe image. Raman spectra (right) for the regions a-c, labeled on the detector fringe image were obtained using a 2D Fourier transform. The spectrum labeled d is a reference Raman spectrum of acetaminophen from the RRUFF database (RRUFF ID D120007). <ref type="bibr">25</ref> Using the MLA-SHRS for Raman imaging, there is a tradeoff between spectral resolution and number of lenslets used in the horizontal direction (e.g., grating grooves illuminated). For example, the spectra produced by region a for a single lenslet, and region b which covers four lenslets vertically, produce spectra with the same resolution, $42 cm &#192;1 , because both regions illuminate the same number of grating grooves. However, the spectrum produced by region c, viewing four lenslets horizontally, has four times higher resolution, $11 cm &#192;1 , because four times as many grating grooves were illuminated. The intensity scales with the number of lenslets viewed, regardless of the direction.</p><p>Figure <ref type="figure">5</ref> shows the Raman image (top left) for a diamond/perchlorate sample (top right). In this image, the MLA was magnified by 10&#194; onto the gratings, and 60 different lenslets are shown, corresponding to a sampled area on the sample of 1.32 &#194; 0.55 mm <ref type="bibr">2</ref> . Lenslets outside this area did not show high contrast fringes. The image is brighter in the diamond region because the diamond Raman cross-section is $3.8 times larger than perchlorate. <ref type="bibr">26,</ref><ref type="bibr">27</ref> Spectra corresponding to three different sample regions are shown (bottom left). Region a shows only the diamond Raman band at 1332 cm &#192;1 , region b shows both potassium perchlorate and diamond Raman bands, and region c shows only the 941 cm &#192;1 Raman band of potassium perchlorate. <ref type="bibr">28,</ref><ref type="bibr">29</ref> The size of the image of each lenslet on the gratings is 0.98 mm. For the 300 lp/mm gratings, this corresponds to a theoretical resolving power of 588, which gives a theoretical spectral resolution of 32 cm &#192;1 . The measured resolution of the spectra shown in Fig. <ref type="figure">5</ref> are consistent with this value, at 33 cm &#192;1 . The grating image is magnified 1.17&#194; on the CCD, so each lenslet has a diameter of 85 pixels, thus allowing 85/2 spectral elements to be measured, giving a theoretical spectral range of 1360 cm &#192;1 . The observed one-lenslet spectral range, $1250 cm &#192;1 , is consistent with this value.</p><p>The Raman image in Fig. <ref type="figure">6</ref> (top left), measured in the same configuration as in Fig. <ref type="figure">5</ref>, shows an example of resolving close lying Raman bands for two samples, sodium sulfate/potassium chlorate, that are separated by no more than two lenslet diameters. The interface between the samples, labeled in the picture inset with a dashed line, is not immediately obvious in the white light image, because both constituents have similar Raman scattering cross-sections. <ref type="bibr">27</ref> The measured spectral resolution for the Raman spectra (bottom left) of the three lenslet regions (a, b, and c) is $33 cm &#192;1 , adequate to distinguish between the sodium   sulfate band at 990 cm &#192;1 and potassium perchlorate Raman band at 941 cm &#192;1 . Note, in this case, the brightness of the lenslets in the Raman image is not indicative of the sample type because in these images we did not correct for changes in light intensity across the image, as might occur from such things as changes in laser power, sample position or flatness with respect to the MLA image plane, density variations in the sample, sample refractive index differences, or luminescence impurities in the samples.</p><p>For transparent, highly scattering samples, the spatial resolution of any Raman imaging technique is limited by diffuse scattering of the laser through the sample, so the laser is not localized at the focal point of the laser but can excite Raman scattering up to many millimeters away. Spatially offset Raman takes advantage of this effect, to increase the volume that is probed for highly scattering samples such as pharmaceutical tablets. <ref type="bibr">15</ref> This is illustrated by the Raman image in Fig. <ref type="figure">7</ref>, for a sodium nitrate/potassium perchlorate sample (top right). In this image, Raman from 60 different MLA lenslets is shown, covering an area on the sample of about 1.32 &#194; 0.55 mm, the magnification was 8&#194; on the gratings. Normalized Raman spectra from eight selected lenslet regions are shown (left). The resolving power per lenslet is 450, which corresponds to a spectral resolution of 41.7 cm &#192;1 , which matches the measured resolution of 42 cm &#192;1 . The grating image is magnified 1.17&#194; on the CCD, so each lenslet image has a diameter of 65 pixels, thus allowing 65/2 spectral elements to be measured, giving a theoretical spectral range of 1365 cm &#192;1 . The observed one-lenslet spectral range, $1250 cm &#192;1 , is consistent with this value.</p><p>If there were no overlap between the Raman signals collected by the lenslets of the array for the bilayer sample used here, we would expect the Raman spectra to change rapidly for lenslets on either side of the sample interface, showing only nitrate (1062 cm &#192;1 ) on one side and only perchlorate (941 cm &#192;1 ) on the other side. <ref type="bibr">30</ref> So, a plot of the intensity ratio of these two bands would show an abrupt change at the interface. Instead, what we see is a more gradual intensity ratio change, due to diffuse scattering in the sample, as shown in Fig. <ref type="figure">7</ref> (lower right). The intensity ratio is shown in this plot, because the Raman intensity changes a lot from lenslet to lenslet and this was not corrected. The shape of the intensity ratio curves in Fig. <ref type="figure">7</ref> is consistent with plots of Raman signal intensity versus relative offset position for spatially offset Raman. <ref type="bibr">31</ref> In fact, the MLA-SHRS hyperspectral imaging system described here would seem to be ideal for quickly making measurements that can be used to test models of spatially offset and transmission Raman.</p><p>Figure <ref type="figure">8</ref> shows a Raman image made up of 546 lenslets (top left) for a diamond/potassium perchlorate sample, with each lenslet showing clear interference fringes. To acquire this image, the MLA was magnified by 4&#194; onto the 150 lp/ mm gratings. The 546 lenslets shown correspond to an area on the sample of 2.31 &#194; 2.86 mm 2 . A CMOS detector (AgenaAstroproducts, QHY183M) with 2.4 mm pixels and overall chip size of 13 &#194; 8 mm 2 was used to acquire this image. The cross-section (bottom) for a selected row of lenslets shows high contrast fringes for each lenslet. Raman spectra, recovered by taking the Fourier transform of the cross-section for two individual lenslets are shown (top right), for lenslets that image diamond and perchlorate regions of the sample. The size of the image of each lenslet on the gratings is 0.4 mm. For the 150 lp/mm gratings, this corresponds to a theoretical resolving power of 120, which gives a theoretical spectral resolution of 148 cm &#192;1 . The measured resolution of the spectra shown in Fig. <ref type="figure">8</ref> is consistent with this value, at 148 cm &#192;1 . This low spectral resolution is limited by the grating groove density and the total number of pixels available on the detector.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Imaging Limitations of the MLA-SHRS</head><p>For the MLA-SHRS technique, the number of spatial elements that can be imaged simultaneously is determined by the grating size and the desired spectral resolution, and also depends on the laser wavelength. For an individual lenslet, the resolution is determined primarily by the number of grating grooves that are illuminated by that lenslet. Table <ref type="table">I</ref> shows the theoretical maximum number of spatial elements that can be imaged using a 25 mm SHRS, for three different laser wavelengths and grating groove densities, assuming a spectral resolution of 20 cm &#192;1 . The calculations show that using 785 nm or 532 nm laser wavelength, over 10 000 spatial points can be simultaneously imaged, with a spectral range that is limited only by the number of pixels available on the detector. Even at 244 nm, almost 4000 lenslets can theoretically be measured. Furthermore, if 30 cm &#192;1 spectral resolution is permissible, then $23 000 lenslets could be imaged at the longer wavelengths. These calculations do not account for loss of coherence across the SHRS grating face. Because the initial SHRS alignment was performed along the center of the optical axis, the loss of coherence will limit the contribution of lenslets far from the center of the grating in the horizontal direction (i.e., parallel to the grating dispersion). The extent of this depends on the coherence length of the bands being measured and the grating Littrow angle. In situations where loss of coherence might occur, physically offset compound gratings, a curved grating, or possibly a refractive optic could be designed to mitigate the problem.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Conclusion</head><p>A new hyperspectral Raman imaging technique is demonstrated using an SHRS with an MLA, where the entire hypercube of spatial and spectral information is obtained in a single measurement. Raman images for a variety of sample types are demonstrated where Raman spectra, at spectral ranges from 1200 cm &#192;1 to 2800 cm &#192;1 , were acquired for 60 to &gt;500 unique spatial points dependent on the type of detector used. The spectral resolution of the Raman spectra acquired for each spatial point in the images varied from 32 cm &#192;1 to 148 cm &#192;1 , dependent on the grating and system magnification. Calculations show that this technique can be extended to include more than 10 000 spatial points with a spectral resolution of 20 cm &#192;1 , with a large spectral range. Loss of coherence across the grating can be compensated using multiple gratings, each with its own center burst position, or using a compensator plate, shaped to reduce the optical path difference across the grating.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Declaration of Conflicting Interests</head><p>The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.  Applied Spectroscopy 74 (8)  </p></div></body>
		</text>
</TEI>
