skip to main content


Title: Effect of retrace error on stitching coherent scanning interferometry measurements of freeform optics

We report on the effect of retrace error during measurement of freeform optics using a commercial coherence scanning interferometer (CSI), and its in-built stitching capabilities. It is shown that measuring segments of freeform optics under non-null conditions, results in artifacts on the measured zone, similar to the Seidel aberrations. An experimental approach is used to quantify the induced aberrations based on the local slopes of the surface. Simulation of surfaces containing different order aberrations is shown to have a significant effect on the measurement data. A correction method is proposed that uses experimental measurements to determine the required correction based on local slope and position in the aperture. These corrections reduce the measurement difference from a comparison measurement using a Fizeau interferometer.

 
more » « less
NSF-PAR ID:
10288707
Author(s) / Creator(s):
; ;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Optics Express
Volume:
29
Issue:
18
ISSN:
1094-4087; OPEXFF
Page Range / eLocation ID:
Article No. 28562
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Multiple wavelength interferometry has long been considered an option for the measurement of large aspheric slope departures. In particular, a synthetic wavelength offers a variety of approaches by which large phase excursions can be unwrapped. Using multiple wavelengths can create collimation and magnification mismatch errors between the individual wavelengths that arise during beam expansion and propagation. Here, we present and analyze alignment and calibration methods for a dual-wavelength interferometer that can significantly reduce both misalignment errors and chromatic aberrations in the system. To correct for misalignment, a general method is described for the alignment of a dual-wavelength interferometer, including the alignment of lasers, beam expanders, beam splitters for combining beams and for compensating errors in the reference surface, and the fringe imaging system. A Fourier transform test at the detector surface was conducted to validate that there is essentially no magnification difference between two wavelengths resulting from misalignment of optical system. For the chromatic aberration introduced by the optical elements in the system, a ray-trace model of the interferometer has been established, to simulate the chromatic effect that optical elements will have on the measurement results. As an experimental test, we examine an off-axis spherical mirror in a non-null condition using a highly aliased interferogram. The above alignment methods and the results are analyzed based on the simulated system errors. Using this method, we demonstrate a measured surface profile of deviation of λ/25 which is comparable to a direct measurement profile of the surface on axis using a Fizeau interferometer. 
    more » « less
  2. This paper presents a study of the grinding of three different grades of silicon carbide (SiC) under the same conditions. Surface topography is analyzed using coherent scanning interferometry and scanning electron microscopy. The study provides a baseline understanding of the process mechanics and targets effective selection of process parameters for grinding SiC optics with near optical level surface roughness, thus reducing the need for post-polishing. Samples are raster and spiral ground on conventional precision machines with metal and copper-resin bonded wheels under rough, medium, and finish grinding conditions. Material microstructure and grinding conditions affect attainable surface roughness. Local surface roughness of less than 3 nm RMS was attained in both chemical vapor deposition (CVD) and chemical vapor composite (CVC) SiC. The tool footprint is suitable for sub-aperture machining of a large freeform optics possibly without the need for surface finish correction by post-polishing. Subsurface damage will be assessed in Part 2 of this paper series. 
    more » « less
  3. The success of ground-based, high contrast imaging for the detection of exoplanets in part depends on the ability to differentiate between quasi-static speckles caused by aberrations not corrected by adaptive optics (AO) systems, known as non-common path aberrations (NCPAs), and the planet intensity signal. Frazin (ApJ, 2013) introduced a post-processing algorithm demonstrating that simultaneous millisecond exposures in the science camera and wavefront sensor (WFS) can be used with a statistical inference procedure to determine both the series expanded NCPA coefficients and the planetary signal. We demonstrate, via simulation, that using this algorithm in a closed-loop AO system, real-time estimation and correction of the quasi-static NCPA is possible without separate deformable mirror (DM) probes. Thus the use of this technique allows for the removal of the quasi-static speckles that can be mistaken for planetary signals without the need for new optical hardware, improving the efficiency of ground-based exoplanet detection. In our simulations, we explore the behavior of the Frazin Algorithm (FA) and the dependence of its convergence to an accurate estimate on factors such as Strehl ratio, NCPA strength, and number of algorithm search basis functions. We then apply this knowledge to simulate running the algorithm in real-time in a nearly ideal setting. We then discuss adaptations that can be made to the algorithm to improve its real-time performance, and show their efficacy in simulation. A final simulation tests the technique’s resilience against imperfect knowledge of the AO residual phase, motivating an analysis of the feasibility of using this technique in a real closed-loop Extreme AO system such as SCExAO or MagAO-X, in terms of computational complexity and the accuracy of the estimated quasi-static NCPA correction. 
    more » « less
  4. Dynamic illumination using tunable freeform arrays can enable spatial light distributions of variable size with high uniformity from non-uniform sources through relatively small opposing lateral shifts applied to the freeform components. We present the design, manufacturing, and characterization of a tunable LED-based illuminator using custom freeform Alvarez arrays with commercially available optics to shorten the manufacturing cycle. The optomechanical design and manufacturing of the Alvarez lens arrays and mounting parts are presented in detail. The optical performance of the system is evaluated and compared with simulation results using a custom camera-based test station. Experimental results demonstrate and confirm the dynamic illumination concept with good uniformity.

     
    more » « less
  5. Precision glass molding is a viable process for the cost-effective volume production of freeform optics. Process development is complex, requiring iterative trials of mold manufacture and metrology, glass mold prototyping, metrology and functional testing. This paper describes the first iteration in the development of a process for an Alvarez lens for visible light. The challenges of this optic are extremely tight band-RMS tolerances on a freeform shape over a maximum clear aperture of 45 mm, a 16:1 aspect ratio and a freeform departure of 329 micrometers. A freeform glass mold for an Alvarez lens was manufactured by coordinated-axis diamond turning in a mold substrate using a custom tool error correction method. The results of prototype precision glass molding are also reported. Mold surfaces and molded optical surfaces are analyzed with scanning white light interferometry. A surface roughness of approximately 3 nm RMS is obtained for both the mold substrate and the glass optic with high-fidelity reproduction of micro-surface structure in the glass. These measurements also identify challenging areas, particularly the presence of mid-spatial frequency errors on the optic originating from the machine thermal control system. The form of the molds was also measured with a profilometer; however, the mold surface does not agree with the expected prescription with an overall deviation in form of approximately 10 μm. The machining process is expected to have sub-micrometer error and the sources of this discrepancy are still being determined. Metrology of the glass optics is currently in progress. 
    more » « less