skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Design and Experimental Evaluation of Mosquito-Inspired Needle Structure in Soft Materials
Insects steer their stingers effortlessly to a specific target and release their venom in a certain path through the skin with minimal pain. These unique traits inspire the idea to develop bioinspired needles to reduce the insertion forces and to decrease the needle path deviation (deflection) for improved targeting accuracy. Our approach in this work focus on the design of mosquito-inspired needle and evaluation of the needle performance using vibration during tissue insertion. The mosquito-inspired needle design specifically consists of maxilla-shaped and labrum-tip design. The insertion force was measured using a force sensor, which was fixed at the needle end to measure the uniaxial force of needles. The applied vibration on the needle was measured along linear axis using piezoelectric actuator with a frequency of 150 Hz and an amplitude of 5μm. The needle was inserted at a constant speed by attaching the needle to a motorized linear stage. It was observed that the insertion forces of the proposed needle design with vibration showed a reduction by 27% compared to that of a conventional needle. This reduction in insertion force means that there is decrease in tissue gel phantom damage and it was also observed that needle bending has reduced due to reduction in bending stiffness of the tissue phantom. Furthermore, the needle insertion tests in real tissues (bovine kidney) considering the proposed needle geometry and vibration will be studied in future work to understand the bioinspired needle-tissue interactions.  more » « less
Award ID(s):
1917711
PAR ID:
10289882
Author(s) / Creator(s):
;
Date Published:
Journal Name:
Proceedings of the ASME 2020 International Mechanical Engineering Congress and Exposition
Volume:
5
Page Range / eLocation ID:
V005T05A012
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. The aim of this work is to propose a mosquito-inspired (bioinspired) design of a surgical needle that can decrease the insertion force and the tissue deformation, which are the main causes of target inaccuracy during percutaneous procedures. The bioinspired needle was developed by mimicking the geometrical shapes of mosquito proboscis. Needle prototypes were manufactured and tested to determine optimized needle shapes and geometries. Needle insertion tests on a tissue-mimicking polyvinylchloride (PVC) gel were then performed to emulate the mosquito-proboscis stinging dynamics by applying vibration and insertion velocity during the insertion. An insertion test setup equipped with a sensing system was constructed to measure the insertion force and to assess the deformation of the tissue. It was discovered that using the proposed bioinspired design, the needle insertion force was decreased by 60% and the tissue deformation was reduced by 48%. This finding is significant for improving needle-based medical procedures. 
    more » « less
  2. Abstract Active needles obtain more significant tip deflection and improved accuracy over passive needles for percutaneous procedures. However, their ability to navigate through tissues to reach targets depends upon the actuation mechanism, the tip shape, and the surface geometry of the shaft. In this study, we investigate the benefits of changing the surface geometry of the active needle shaft in a) needle tip deflection and b) trajectory tracking during tissue insertion. The modifications in passive needle surface geometry have been proven to reduce friction force, tissue displacement, and tissue damage. This study incorporates the effect of modifying the regular smooth cannula with a mosquito proboscis-inspired design in the active needles. The changes in insertion force, tip deflection, and trajectory tracking control during insertion into a prostate-mimicking phantom are measured. Results show that insertion force is reduced by up to 10.67% in passive bevel-tip needles. In active needles, tip deflection increased by 12.91% at 150mm when the cannula is modified. The bioinspired cannula improved trajectory tracking error in the active needle by 39.00% while utilizing up to 17.65% lower control duty cycle. Improving tip deflection and tracking control would lead to better patient outcomes and reduced risk of complications during percutaneous procedures. 
    more » « less
  3. Abstract Active needles obtain more significant tip deflection and improved accuracy over passive needles for percutaneous procedures. However, their ability to navigate through tissues to reach targets depends upon the actuation mechanism, the tip shape, and the surface geometry of the shaft. In this study, we investigate the benefits of changing the surface geometry of the active needle shaft in a) needle tip deflection and b) trajectory tracking during tissue insertion. The modifications in passive needle surface geometry have been proven to reduce friction force, tissue displacement, and tissue damage. This study incorporates the effect of modifying the regular smooth cannula with a mosquito proboscis-inspired design in the active needles. The changes in insertion force, tip deflection, and trajectory tracking control during insertion into a prostate-mimicking phantom are measured. Results show that insertion force is reduced by up to 10.67% in passive bevel-tip needles. In active needles, tip deflection increased by 12.91% at 150mm when the cannula is modified. The bioinspired cannula improved trajectory tracking error in the active needle by 39% while utilizing up to 17.65% lower control duty cycle. Improving tip deflection and tracking control would lead to better patient outcomes and reduced risk of complications during percutaneous procedures. 
    more » « less
  4. Abstract Active needles demonstrate improved accuracy and tip deflection compared to their passive needle counterparts, a crucial advantage in percutaneous procedures. However, the ability of these needles to effectively navigate through tissues is governed by needle-tissue interaction, which depends on the tip shape, the cannula surface geometry, and the needle insertion method. In this research, we evaluated the effect of cannula surface modifications and the application of a vibrational insertion technique on the performance of shape memory alloy (SMA)-actuated active needles. These features were inspired by the mosquito proboscis’ unique design and skin-piercing technique that decreased the needle tissue interaction force, thus enhancing tip deflection and steering accuracy. The bioinspired features, i.e., mosquito-inspired cannula design and vibrational insertion method, in an active needle reduced the insertion force by 26.24% and increased the tip deflection by 37.11% in prostate-mimicking gel. In addition, trajectory tracking error was reduced by 48%, and control effort was reduced by 23.25%, pointing towards improved needle placement accuracy. The research highlights the promising potential of bioinspired SMA-actuated active needles. Better tracking control and increased tip deflection are anticipated, potentially leading to improved patient outcomes and minimized risk of complications during percutaneous procedures. 
    more » « less
  5. Abstract Soft tissue biopsy is a necessary diagnostic and therapeutic procedure, but traditional biopsy needles can cause harm to the patient, including tissue damage, bleeding, and pain. These can compromise the accuracy of the sample and negatively impact the patient’s well-being. Hence, there has been a growing interest in developing bio-inspired surgical needles that are safer, more effective, and more comfortable for the patient. The scorpion-inspired curved tip needle study focuses on analyzing the mechanics of needle-tissue interaction and creating needles that travel through soft tissue with minimum resistance at the tip. An essential aspect of the study is the mechanics and geometry of the needle tip, which plays a crucial role in its performance. The study incorporates structures of curved scorpion’s stinger to balance between penetration and minimal needle-tissue interaction forces. In this study, various parameters of curved tip geometry are explored to decrease the insertion and extraction forces. Tests are initially performed on brain tissue mimicking medical gelatin with Young’s modulus of 2kPa. It is observed that the insertion force with curved tip needles is decreased by up to 21.7%, and the extraction force is decreased by up to 28.2%. This study shows that a scorpion-inspired tip design can minimize insertion and extraction forces, leading to less tissue damage and deformation. Furthermore, the proposed tip design has great potential to improve surgical needles for more effective minimally invasive percutaneous procedures with various applications such as biopsy, brachytherapy, tumor ablation, and drug delivery to the brain. 
    more » « less