Title: Characterization and performance of the upgraded NIRSPEC on the W. M. Keck Telescope
NIRSPEC is a high-resolution near-infrared echelle spectrograph on the Keck II telescope that was commissioned in 1999 and upgraded in 2018. This recent upgrade was aimed at improving the sensitivity and longevity of the instrument through the replacement of the spectrometer science detector (SPEC) and slit-viewing camera (SCAM). Commissioning began in 2018 December, producing the first on-sky images used in the characterization of the upgraded system. Through the use of photometry and spectroscopy of standard stars and internal calibration lamps, we assess the performance of the upgraded SPEC and SCAM detectors. First, we evaluate the gain, readnoise, dark current, and the charge persistence of the spec detector. We then characterize the newly upgraded spectrometer and the resulting improvements in sensitivity, including spectroscopic zero points, pixel scale, and resolving power across the spectrometer detector field. Finally, for SCAM, we present zero points, pixel scale, and provide a map of the geometric distortion of the camera.  more » « less
Award ID(s):
1801978
NSF-PAR ID:
10292792
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ;
Editor(s):
Evans, Christopher J.; Bryant, Julia J.; Motohara, Kentaro
Date Published:
Journal Name:
SPIE Astronomical Telescopes & Instrumentation 2020 Proceedings
Volume:
11447
Page Range / eLocation ID:
121
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Evans, Christopher J. ; Bryant, Julia J. ; Motohara, Kentaro (Ed.)
    We present the current design of WFOS, a wide-field UV/optical (0.31-1.0 µm) imaging spectrograph planned for first-light on the TMT International Observatory 30 m telescope. WFOS is optimized for high sensitivity across the entire optical waveband for low-to-moderate resolution (R ∼ 1500-5000) long-slit and multi-slit spectroscopy of very faint targets over a contiguous field of view of 8′ .3×3 ′ .0 at the f/15 Nasmyth focus of TMT. A key design goal for WFOS is stability and repeatability in all observing modes, made possible by its gravity-invariant opto-mechanical structure, with a vertical rotation axis and all reconfigurable components moving only in planes defined by tiered optical benches parallel to the Nasmyth platform. WFOS’s optics include a linear ADC correcting a 9′ diameter field, including both the science FoV and 4 patrolling acquisition, guiding, and wavefront sensing camera systems; a novel 2-mirror reflective collimator allowing the science FoV to be centered on the telescope optical axis; a dichroic beamsplitter dividing the collimated beam into 2 wavelength-optimized spectrometer channels (blue: 0.31-0.56 µm; red: 0.54-1.04 µm); selectable transmissive dispersers (VPH and/or VBG) with remotely configurable grating tilt (angle of incidence) and camera articulation that enable optimization of diffraction efficiency and wavelength coverage in each channel; all-refractive, wavelength-optimized f/2 spectrograph cameras, and UV/blue and red-optimized detector systems. The predicted instrumental through put of WFOS for spectroscopy averages > 56% over the full 0.31-1 µm range, from the ADC to the detector. When combined with the 30 m TMT aperture, WFOS will realize a factor of ∼20 gain in sensitivity compared to the current state of the art on 8-10 m-class telescopes. 
    more » « less
  2. Abstract Single-photon counters are single-pixel binary devices that click upon the absorption of a photon but obscure its spectral information, whereas resolving the color of detected photons has been in critical demand for frontier astronomical observation, spectroscopic imaging and wavelength division multiplexed quantum communications. Current implementations of single-photon spectrometers either consist of bulky wavelength-scanning components or have limited detection channels, preventing parallel detection of broadband single photons with high spectral resolutions. Here, we present the first broadband chip-scale single-photon spectrometer covering both visible and infrared wavebands spanning from 600 nm to 2000 nm. The spectrometer integrates an on-chip dispersive echelle grating with a single-element propagating superconducting nanowire detector of ultraslow-velocity for mapping the dispersed photons with high spatial resolutions. The demonstrated on-chip single-photon spectrometer features small device footprint, high robustness with no moving parts and meanwhile offers more than 200 equivalent wavelength detection channels with further scalability. 
    more » « less
  3. Spatial heterodyne Raman spectrometers (SHRSs) are modified forms of Michelson interferometers, except the mirrors in a Michelson interferometer are replaced with stationary diffraction gratings. This design removes the need for an entrance slit, as is the case in a dispersive spectrometer, and removes the need to scan the spectrum by using a moving mirror in a modern Michelson interferometer. In previous studies, various SHRS variants, such as free-standing two-grating SHRS, single-grating SHRS (1g-SHRS), monolithic SHRS (mSHRS), and single-grating mSHRS (1g-mSHRS), have been evaluated. However, the present study exclusively focuses on the 1g-mSHRS configuration. The 1g-mSHRS and 1g-SHRS increase the spectral range at fixed grating line density while trading off spectral resolution and resolving power. The mSHRS benefits from increased rigidity, lack of moving parts, and reduced footprint. In this study, we investigate how the choice of detector impacts the performance of the 1g-mSHRS system, with a specific focus on evaluating the performance of three types of cameras: charged-coupled device (CCD), intensified CCD (ICCD), and complementary metal–oxide–semiconductor (CMOS) cameras. These systems were evaluated using geological, organic, and inorganic samples using a 532 nm continuous wave laser for the CMOS and CCD cameras, and a 532 nm neodymium-doped yttrium aluminum garnet pulsed laser for the ICCD camera. The footprint of the 1g-mSHRS was 3.5 × 3.5 × 2.5 cm3with a mass of 272 g or 80 g, depending on whether the monolith housing is included or not. We found that increasing the number of pixels utilized along the x-axis of the camera increases fringe visibility (FV) and optimizes the resolution (by capturing the entirety of the grating and magnifying the fringes). The number of pixels utilized in the y-axis, chip size, and dimensions, affect the signal-to-noise ratio of the systems. Additionally, we discuss the effect of pixel pitch on the recovery of Fizeau fringes, including the relationship between the Nyquist frequency, aliasing, and FV.

     
    more » « less
  4. Mérand, Antoine ; Sallum, Stephanie ; Tuthill, Peter G. (Ed.)
    The Southern Connecticut Stellar Interferometer (SCSI) is an intensity interferometer that is designed to use correlated photon arrival times to determine the geometry of stars. Originally a low-cost, two-telescope instrument that used a 1-pixel single-photon avalanche diode (SPAD) detector at the focal plane of each telescope to record photon events, it is now being upgraded to include a third telescope. This will allow for the simultaneous detection of the photon correlation at three baselines, and thus the ability to map out the two-dimensional geometry of the source much more efficiently than with the two-telescope arrangement. Recent papers in the literature suggest that it may be possible to derive phase information in the Fourier domain from such triple correlations for the brightest stars, potentially giving SCSI an imaging capability. Prior to investigating this possibility, steps must be taken to maximize the observing efficiency of the SCSI. We present here our latest efforts in achieving better pointing, tracking, and collimation with our telescopes, and we discuss our first modeling results of the three-telescope situation in order to understand under what conditions the upgraded SCSI could retrieve imaging information. 
    more » « less
  5. Abstract

    The Airborne Infrared Spectrometer (AIR-Spec) offers an unprecedented opportunity to explore the near-infrared (NIR) wavelength range. It has been flown at two total solar eclipses, in 2017 and 2019. The wavelength range of the much-improved instrument on the second flight (2019 July 2) was shifted to cover two density-sensitive lines from Sxi. In this paper we study detailed diagnostics for temperature, electron density, and elemental abundances by comparing results from AIR-Spec slit positions above the east and west limbs with those from Hinode/EIS, the PolarCam detector, and SDO/AIA. We find very good agreement in the electron densities obtained from the EIS EUV line ratios, those from the NIR Sxiratio, and those obtained from the polarized brightness PolarCam measurements. Electron densities ranged from logNe[cm−3] = 8.4 near the limb to 7.2 atR0= 1.3. EIS spectra indicate that the temperature distribution above the west limb is near isothermal at around 1.3 MK, while that on the east has an additional higher-Tcomponent. The AIR-Spec radiances in Sixand Sxi, as well as the AIA data in the 171, 193, and 211 Å bands, are consistent with the EIS results. EIS and AIR-Spec data indicate that the sulfur abundance (relative to silicon) is photospheric in both regions, confirming our previous results of the 2017 eclipse. The AIA data also indicate that the absolute iron abundance is photospheric. Our analysis confirms the importance of the diagnostic potential of the NIR wavelength range and that this important wavelength range can be used reliably and independently to determine coronal plasma parameters.

     
    more » « less