skip to main content


Title: Tunable Resonant‐Photopyroelectric Detector Using Chalcogenide−Metal−Fluoropolymer Nanograting
Abstract

Pyroelectric detectors are often broadband and require external filters for wavelength‐specific applications. This paper reports a tunable, narrowband, and lightweight pyroelectric infrared detector built upon a flexible membrane of As2S3−Ag−P(VDF‐TrFE) with subwavelength grating, which is capable of both on‐chip filtering and photopyroelectric energy conversion. The top surface of this hybrid membrane is a corrugated As2S3−Ag film contributing to narrowband light absorption in the near‐infrared (NIR) regime, and the bottom part is a polyvinylidene fluoride‐trifluoroethylene (PVDF‐TrFE) membrane for the conversion of the absorbed light to an electrical signal. Uniquely, applying a bias voltage to the PVDF‐TrFE membrane enables the tuning of the device's absorption and pyroelectric characteristics owing to the piezoelectrically induced mechanical bending. The resonator exhibited a resonant absorption coefficient of 80% and a full‐width‐half‐maximum of 15 nm within the NIR, a responsivity of 1.4 mV mW−1, and an equivalent noise power of 13 µW Hz−1/2at 1560 nm. By applying a 15‐V bias to the PVDF‐TrFE membrane, the absorption coefficient decreased to 18% due to the change in the grating period and incident angle. The narrowband and tunable features of the As2S3−Ag−P(VDF‐TrFE) pyroelectric detector will benefit a variety of potential applications in sensors, optical spectroscopy, and imaging.

 
more » « less
Award ID(s):
1711839 1653673
NSF-PAR ID:
10362092
Author(s) / Creator(s):
 ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Advanced Optical Materials
Volume:
9
Issue:
22
ISSN:
2195-1071
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1.  
    more » « less
  2. Abstract

    Here, a wavelength‐specific photo‐thermoelectric (PTE) device is reported that achieves narrowband optical absorption and thermoelectric conversion functions using a stack of thin films on a grating‐patterned substrate. Conventional PTE devices are broadband with the absorption of electromagnetic radiation from ultraviolet to terahertz. There are demands for PTE devices that can exhibit narrowband response at a desired wavelength. Here, the narrowband PTE device consists of a photonic crystal (PC) filter with metal cladding and a thin‐film thermocouple. The PC‐PTE design is investigated numerically to illustrate the underlying energy conversion mechanism. The device is fabricated using nanoreplica molding followed by coating of thin films. The fabricated metal‐cladding PC resonator exhibits a narrowband optical absorption with a resonant absorption coefficient of 85.4% and full‐width‐half‐maximum of 14.8 nm in the visible wavelength range. The PTE measurements show that the thermoelectric output is sensitive to the coupling of incident light and guided‐mode resonance modes. Illuminated under the resonant condition, the PTE device exhibits a responsivity and noise equivalent power of 0.26 V W−1and 7.5 nW Hz−1/2, respectively. This PC‐PTE technology has the unique attributes of narrowband detection, large surface area, and low cost for the potential application in sensors, optical spectroscopy, and imaging.

     
    more » « less
  3. We demonstrate an on-chip spectrometer readily integrable with CMOS electronics. The structure is comprised of a SiO2/Si3N4/SiO2waveguide atop a silicon substrate. A transversely chirped grating is fabricated, in a single-step optical lithography process, on a portion of the waveguide to provide angle and wavelength dependent coupling to the guided mode. The spectral and angular information is encoded in the spatial dependence of the grating period. A uniform pitch grating area, separated from the collection area by an unpatterned propagation region, provides the out-coupling to a CMOS detector array. A resolution of 0.3 nm at 633 nm with a spectral coverage tunable across the visible and NIR (to ∼ 1 µm limited by the Si photodetector) by changing the angle of incidence, is demonstrated without the need for any signal processing deconvolution. This on-chip spectrometer concept will cost effectively enable a broad range of applications that are beyond the reach of current integrated spectroscopic technologies.

     
    more » « less
  4. Abstract

    The flexible, transparent, and low‐weight nature of ferroelectric polymers makes them promising for wearable electronic and optical applications. To reach the full potential of the polarization‐enabled device functionalities, large‐scale fabrication of polymer thin films with well‐controlled polar directions is called for, which remains a central challenge. The widely exploited Langmuir–Blodgett, spin‐coating, and electrospinning methods only yield polymorphous or polycrystalline films, where the net polarization is compromised. Here, an easily scalable approach is reported to achieve poly(vinylidene fluoride‐trifluoroethylene) P(VDF‐TrFE) thin films composed of close‐packed crystalline nanowires via interface‐epitaxy with 1T′‐ReS2. Upon controlled thermal treatment, uniform P(VDF‐TrFE) films restructure into about 10 and 35 nm‐wide (010)‐oriented nanowires that are crystallographically aligned with the underlying ReS2, as revealed by high‐resolution transmission electron microscopy. Piezoresponse force microscopy studies confirm the out‐of‐plane polar axis of the nanowire films and reveal coercive voltages as low as 0.1 V. Reversing the polarization can induce a conductance switching ratio of >108in bilayer ReS2, over six orders of magnitude higher than that achieved by an untreated polymer gate. This study points to a cost‐effective route to large‐scale processing of high‐performance ferroelectric polymer thin films for flexible energy‐efficient nanoelectronics.

     
    more » « less
  5. Hemoglobin is one of the most important chromophores in the human body, since oxygen is carried to the tissue by binding with the hemoglobin. Therefore measuring the concentrations of oxy-hemoglobin (HbO) and deoxy-hemoglobin (HbR) is very important in both clinical settings and academic fields. Frequency domain near infrared spectroscopy (fdNIR spectroscopy) is a technique that can be used to measure the absolute concentrations of HbO and HbR non-invasively and locally. The fdNIR spectrometer utilizes the attenuation and the phase shift (with respect to the source) that an intensity modulated NIR light experiences in order to calculate the absorption (μa) and reduced scattering (μs) coefficient of the tissue. In this work, a miniaturized dual-wavelength fdNIR spectrometry instrument is presented with both tissue-like phantom and in vivo occlusion measurements. Systematic tests were performed on tissue phantoms to quantify the accuracy and stability of the instrument. The absolute errors for μaand μs were below 15% respectively. The amplitude and phase uncertainty were below 0.25% and 0.35°. In vivo measurements were also conducted to further validate the system.

     
    more » « less