Near‐fault pulse‐type ground motions have characteristics that are substantially different from ordinary far‐field ground motions. It is essential to understand the unique effects of pulse‐type ground motions on structures and include the effects in seismic design. This paper investigates the effects of near‐fault pulse‐type ground motions on the structural response of a 3‐story steel structure with nonlinear viscous dampers using the real‐time hybrid simulation (RTHS) testing method. The structure is designed for 75% of the code‐specified design base shear strength. In the RTHS, the loop of action and reaction between the experimental and numerical partitions are executed in real time, accurately capturing the velocity pulse effects of pulse‐type ground motions. A set of 10 unscaled pulse‐type ground motions at the design basis earthquake (DBE) level is used for the RTHS. The test results validated that RTHS is a viable method for experimentally investigating the complicated structural behavior of structures with rate‐dependent damping devices, and showed that the dampers are essentially effective in earthquake hazard mitigation effects involving pulse‐type ground motions. The average peak story drift ratio under the set of pulse‐type ground motions is 1.08% radians with a COV value less than 0.3, which indicated that structural system would achieve the ASCE 7–10 seismic performance objective for Occupancy Category III structures under the DBE level pulse‐type ground motions. Additionally, a nonlinear Maxwell model for the nonlinear viscous dampers is validated for future structural reliability numerical studies involving pulse‐type ground motions.
more » « less- NSF-PAR ID:
- 10445202
- Publisher / Repository:
- Wiley Blackwell (John Wiley & Sons)
- Date Published:
- Journal Name:
- Earthquake Engineering & Structural Dynamics
- Volume:
- 50
- Issue:
- 15
- ISSN:
- 0098-8847
- Page Range / eLocation ID:
- p. 4032-4050
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
This paper investigates the effects of near-fault pulse-type ground motions on the structural response of a 3-story steel structure with nonlinear viscous dampers using the real-time hybrid simulation (RTHS) testing method. The real time loop of action and reaction between the experimental and numerical partitions executed in the RTHS enabled the accurate capturing of the velocity pulse effects of pulse-type ground motions. An ensemble of 10 natural pulse-type ground motions at the design basis earthquake (DBE) level is used for the RTHS. The accuracy of RTHS under high velocity loading is demonstrated, and thereby, is a validated method for experimentally investigation of the complicated structural behavior of structures with rate-dependent damping devices. The test results showed that the dampers are essentially effective in earthquake hazard mitigation effects involving pulse-type ground motions. The average peak story drift ratio under the set of pulse-type ground motions is 1.08% radians with a COV value less than 0.3, which indicates that the investigated structure would achieve the ASCE 7-10 seismic performance objective for Occupancy Category III structures under the DBE level pulse-type ground motions.more » « less
-
Summary This paper addresses the effectiveness and optimal design of nonlinear viscous dampers for inelastic structures. First, a nonlinear damping index is derived by using the dimensional analysis to estimate the damping induced by supplemental nonlinear dampers on inelastic single degree of freedom (SDOF) structures. Subsequently, the effects of the added nonlinear damping on the seismic responses of inelastic SDOF systems are analyzed in dimensionless forms when subject to various near‐fault ground motions. The structure‐to‐motion frequency ratio, the motion characteristics, and the structural nonlinearity are the main factors that will affect the damping effectiveness. Especially, it is shown that adding nonlinear viscous dampers will decrease displacement demands yet sometimes lead to amplified acceleration responses. Furthermore, an equivalency procedure is developed to match the inelastic multi‐degree of freedom (MDOF) structure that is equipped with multiple nonlinear viscous dampers to its corresponding SDOF system. Such equivalency justifies that the analysis results for the viscous damping efficiency on SDOF systems can be congruously applied to realistic multi‐story structures. Finally, the optimal designs of nonlinear dampers for MDOF inelastic structures are identified by implementing a hybrid genetic optimization framework along with a robust performance index.
-
Large-scale multi-directional real-time hybrid simulations (RTHS) are used to assess the maximum considered earthquake (MCE) seismic performance of a 40-story steel building equipped with supplemental nonlinear viscous dampers. These dampers are placed between outrigger trusses and the perimeter columns of a building that was part of the inventory for the California Tall Building Initiative (TBI) PEER study. The analytical substructure for the RTHS consists of a 3-D nonlinear model of the building while the experimental substructure consists of a full scale nonlinear viscous damper. Other dampers in the structure are analytically modelled using an online explicit model updating scheme where the physical damper is used to obtain the parameters of the analytical damper models during the RTHS. The displacement, residual drift, and ductility demand are found to be reduced by adding the dampers to the outrigger, but only in the direction of the plane of the outriggers. Higher modes, including torsional modes, contribute to the 3-D seismic response.more » « less
-
Recent earthquakes in many parts of the world have resulted in damage to the civil infrastructure, resulting in fatalities and economic loss. This experience has resulted in stake holders demanding a more resilient infrastructure and the mitigation of earthquake hazards to minimize their impact on society. Researchers have developed concepts for structural steel systems to promote resilient performance. Real-time hybrid simulation (RTHS) provides an experimental technique to meet the need to validate new concepts. RTHS enables a complete structural system, including the soil and foundation to be considered in a simulation, interaction effects and rate dependency in component and system response to be accounted for, and realistic demand imposed onto the system for prescribed hazard levels. This paper presents the concept of RTHS and developments achieved at the Lehigh NHERI Experimental Facility that have advanced RTHS to enable accurate large-scale, multidirectional simulations involving multi-natural hazards to be performed. The role that hybrid simulation has played in these developments and how its use has enabled a deeper understanding of structural system behavior under seismic and wind loading will be discussed. Examples include self-centering steel moment resisting frame systems, braced frame systems with nonlinear viscous, and tall buildings with outriggers that are outfitted with nonlinear viscous.more » « less
-
null (Ed.)Nonlinear time history analyses were conducted for 5-story and 12-story prototype buildings that used post-tensioned cross-laminated timber rocking walls coupled with U-shaped flexural plates (UFPs) as the lateral force resisting system. The building models were subjected to 22 far-field and 28 near-fault ground motions, with and without directivity effects, scaled to the design earthquake and maximum considered earthquake for Seattle, with ASCE Site Class D. The buildings were designed to performance objectives that limited structural damage to crushing at the wall toes and nonlinear deformation in the UFPs, while ensuring code-based interstory drift requirements were satisfied and the post-tensioned rods remained linear. The walls of the 12-story building had a second rocking joint at midheight to reduce flexural demands in the lower stories and interstory drift in the upper stories. The interstory drift, in-plane wall shear and overturning moment, UFP deformation, and extent of wall toe crushing is summarized for each building. Near-fault ground motions with directivity effects resulted in the largest demands for the 5-story building, while the midheight rocking joint diminished the influence of ground motion directivity effects in the 12-story building. Results for both buildings confirmed that UFPs located higher from the base of the walls dissipated more energy compared to UFPs closer to the base.more » « less