<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Sliding Mode Control Scheme of a Cascaded H-Bridge Multilevel Active Front End Rectifier</title></titleStmt>
			<publicationStmt>
				<publisher></publisher>
				<date>06/28/2021</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10316417</idno>
					<idno type="doi">10.1109/PEDG51384.2021.9494173</idno>
					<title level='j'>2021 IEEE 12th Annual International Symposium on Power Electronics for Distributed Generation Systems</title>
<idno></idno>
<biblScope unit="volume"></biblScope>
<biblScope unit="issue"></biblScope>					

					<author>Garry Jean-Pierre</author><author>Necmi Altin</author><author>Adel Nasiri</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[In this study, a sliding mode control (SMC) scheme is proposed for the single-phase cascaded H-bridge (CHB) multilevel active front end (AFE) rectifier with LCL filter. A PI controller is employed to control the DC voltage of the rectifier modules and to obtain the amplitude for the reference grid current. The SMC based current control scheme uses the grid current and filter capacitor voltage feedbacks. The resonance of the LCL filter is damped using the voltage feedback of the capacitor. Therefore, the requirement for additional damping circuitry is removed. Simulation and experimental results are presented to verify the performance of the SMC for the CHB multilevel AFE rectifier. The overall proposed control scheme provides almost unity power factor and fast transient response. It is seen from the results that the current drawn from the grid is in sinusoidal waveform with low THD.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head>INTRODUCTION</head><p>Innovation in power electronics made it possible to operate at voltage levels far off the conventional semiconductor operating limits. New multilevel converter configurations have been studied for medium and high voltage applications. These converters are able to achieve high voltage switching through different voltage steps. The multilevel converter topologies can be classified into three main groups: flying capacitor, neutral point clamped, and cascaded H-bridge (CHB) converters. CHB is a promising configuration for medium and high power applications. It presents numerous advantages, such as the ability to provide better harmonic attenuation and mitigate electromagnetic interference. Additionally, it can be configured by cascading multiple single-phase H-bridge modules into one compact system. This structure can provide a low cost solution for the medium-voltage high-power conversion applications due to requiring a smaller number of switching devices and components than other multilevel converter topologies with the same voltage rating <ref type="bibr">[1]</ref>- <ref type="bibr">[2]</ref>.</p><p>When configured as a rectifier, the CHB converter has multiple DC-link voltages which can be used for different power ratings, making this topology an excellent choice for traction applications, solid state transformers, and medium and high power motor drives <ref type="bibr">[3]</ref>- <ref type="bibr">[5]</ref>. However, this configuration comes with some drawbacks: isolated power supplies become a requirement when the converter is operating as a voltage source inverter and achieving unity power factor while operating at the desired limits of the device can be cumbersome <ref type="bibr">[6]</ref>- <ref type="bibr">[7]</ref>.</p><p>A DC-side voltage control, the grid voltage synchronization, and the grid current control are the typical components of a CHB AFE rectifier control unit. A 3-D space modulation scheme was presented in <ref type="bibr">[8]</ref> to achieve DC voltage balancing in all operation modes. A hybrid modulation technique was presented in <ref type="bibr">[9]</ref> for both balancing DC voltage using the low-frequency switching and for grid current control utilizing the high-frequency sinusoidal pulse width modulation. In <ref type="bibr">[10]</ref>, a cascaded PI controller was used to regulate both the DC voltage and the utility current. The model predictive control was utilized in <ref type="bibr">[11]</ref> for fault localization and in <ref type="bibr">[12]</ref> to reduce high computational complexity and to improve the steady-state performance of the current. In <ref type="bibr">[13]</ref>, a dual-model predictive control technique was presented to enhance the dynamic and harmonic performance and to balance the DC voltage.</p><p>The control strategies employed in CHB AFE rectifiers are used to achieve the following objectives: produce constant output DC-link voltage, draw sinusoidal grid current, and balance the DC bus voltage of the capacitor. In addition to the different control methods used in <ref type="bibr">[7]</ref>- <ref type="bibr">[12]</ref>, nonlinear control was used in <ref type="bibr">[14]</ref>, where a modified Lyapunov control strategy combined with a proportional resonant controller and a voltage balancing controller was studied to control the CHB rectifier.</p><p>In regards to the current control strategy, numerous currenttracking techniques have been presented. A small signal decoupled dq current control method <ref type="bibr">[15]</ref> was used to solve the issue of low frequency oscillation. The hysteresis and discrete pulse current control techniques were presented in <ref type="bibr">[16]</ref> to realize same switching frequencies between the inverter switches. A proportional resonant current regulation method was studied in <ref type="bibr">[17]</ref> to maintain the grid current in sinusoidal and to achieve low THD. The model predictive current control method was studied and compared to other traditional current control techniques in <ref type="bibr">[18]</ref> to establish its simplicity and operating principles. A transient current control method based notch filter approach was studied in <ref type="bibr">[19]</ref> to eliminate the oscillation in rail road power electronic applications.</p><p>The SMC, a well-known nonlinear control method, has been studied in many converter topologies. It was used in a neutralpoint clamped converter to improve steady-state and dynamic performance <ref type="bibr">[20]</ref>. The SMC presented in <ref type="bibr">[21]</ref> was used for a 7level grid-tied inverter. Through manipulation of the hysteresis bandwidth of the error resulting from the capacitor voltage control, the minimum average switching frequency was obtained. A variant of the SMC was studied in <ref type="bibr">[22]</ref> in a three-phase grid-connected system for wind energy to control the reactive and active power flows between the system and the grid. In <ref type="bibr">[23]</ref> and <ref type="bibr">[24]</ref>, SMC was presented to control the single-phase and three-phase grid connected inverters with LCL filters and no additional active or passive resonance damping methods. A space vector modulation based SMC was studied in <ref type="bibr">[25]</ref> to regulate the grid current and the flow of active and reactive power in a three-level grid-connected neutral point clamped inverter. SMC technique was proposed in <ref type="bibr">[26]</ref> to eliminate error in the grid current tracking accuracy and to decrease the THD of a single-phase grid-connected voltage source inverter with an LCL filter. In addition, the SMC was proposed to control the current of grid-connected two-leg reduced number of switch neutral point clamped and T-type multilevel inverters <ref type="bibr">[27]</ref> and <ref type="bibr">[28]</ref>.</p><p>Due to the excellent features of the SMC, such as tracking grid current, drawing current with reduced harmonic components, and controlling the output voltage and reactive and active power for various converter topologies, this paper studies the SMC based current control scheme for the single-phase CHB AFE rectifier. The proposed control scheme employs a PI DC voltage controller and a high performance current control scheme based on the SMC. The proposed system is validated with simulation and experimental results. The results show that the proposed system is drawing sinusoidal currents which are in the same phase with the grid voltage and at the same frequency, even for low load conditions. In addition, the proposed system is tested for step load changes and it is seen that the control method offers fast dynamic response and removes the steadystate error.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>II. MODELING OF THE CHB MULTILEVEL AFE</head><p>The CHB multilevel rectifier circuits have the same advantages of the multilevel converters. The CHB is inherently in modular structure and can be considered as a serial connection of number of H-bridges. With this feature, this topology is very suitable to handle high voltage levels, and enables direct medium voltage connection. Along with these advantages, each H-bridge in this topology generates an output DC voltage.</p><p>In high power isolated DC-DC converter applications, due to the high frequency magnetic material core size limitations, it is very common to use parallel connected multiple isolated dc-DC converter units. If the primary side of the system is at high voltage level, this high voltage side can be connected in series to handle the high voltage level, while the low voltage secondary windings can be connected in parallel. This topology is called input series output parallel topology and it is very attractive high power high frequency medium voltage to low voltage applications. With multiple output voltage generation capability, the CHB is naturally generated the required input voltages for the isolated DC-DC converter units. Thus primary side voltage levels can be divided into the number of converter units. The output of the converter units can be connected in parallel to obtain the same power capability with input series output parallel topology.</p><p>A single-phase CHB multilevel AFE rectifier output is shown in Fig. <ref type="figure">1</ref>. It is composed of three identical single-phase H-bridge modules generating three separate DC bus voltages, Vo1, Vo2 and Vo3. An LCL filter is installed to filter out the high frequency components from the current drawn from the grid. The LCL filter is composed of Z1, Z2 and Cf . Here, Z2 is the series combination of L2 and r2. Z1 is the series combination of L1 and r1. The equations describing the CHB converter can be written as ( <ref type="formula">1</ref>) -( <ref type="formula">6</ref>).</p><p>Equation ( <ref type="formula">7</ref> III. PROPOSED CONTROL SCHEME Fig. <ref type="figure">2</ref> shows the proposed control scheme for the control of the CHB multilevel AFE rectifier. The PI method is used to regulate the output DC voltage. The number of output voltages, n, is summed and divided by n. In this case, n = 3. This value is controlled to track the desired voltage value. The PI controller generates the amplitude of the reference current value. By using the PLL output, the reference current signal for the current controller is generated.</p><p>The state-variables can be formulated in ( <ref type="formula">7</ref>) -( <ref type="formula">9</ref>), where * , * and * are the references for , and .</p><p>= - * (10)</p><p>The reference signal of the grid current is defined by the DC voltage controller. A PI controller is employed to track the DC voltage reference (Vo*), as given below:</p><p>where sin&#969;t is obtained from the PLL. * and * can be obtained, as below:</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>A-SMC Control Scheme</head><p>The sliding surface is defined as</p><p>where and are positive real constants. When the system enters into the sliding mode ( = 0), the state variables are forced to move on a sliding surface towards the origin ( = 0, = 0, and = 0). To ensure that the motion of the state variables is maintained on the sliding surface, the existence condition must be met:</p><p>where represents the time derivative of S, and can be written as <ref type="bibr">(17)</ref>.</p><p>Time derivatives of the state variables can be written as follows:</p><p>where = 1 &#8260; , = 1 &#8260; , and the disturbance term ( ) is given with</p><p>Substituting ( <ref type="formula">18</ref>)-( <ref type="formula">20</ref>) into ( <ref type="formula">17</ref>) results in</p><p>where ( ) is the disturbance term given with:</p><p>To ensure the stability of the control system, existence of the sliding mode operation should be verified by satisfying &lt; 0. The control variable u is expressed as below:</p><p>Details on the controller design can be found in <ref type="bibr">[23]</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>IV. SIMULATION AND EXPERIMENTAL RESULTS</head><p>The proposed system is verified with simulation and experimental studies. The proposed controller was studied for both steady-state and transient conditions. For the simulation studies, the following parameters are used: grid voltage is 230V; the inverter side filter inductance is 0.8mH; the grid side filter inductance is 0.5mH; the filter capacitor is 10&#181;F; resistances of inverter and grid side inductors are 0.08&#8486; and 0.05&#8486;, respectively; and the DC bus voltage is 200V. The results of the simulation are presented in Fig. <ref type="figure">3</ref><ref type="figure">4</ref><ref type="figure">5</ref><ref type="figure">6</ref>.     It &#305;s also seen that three output voltages are balanced. The harmonic content of the grid current is also investigated. Fig. <ref type="figure">5</ref> shows the current harmonic spectra. It is evident that the proposed SMC based controller provides low grid current THD (1.81%)&#246; and almost unity power factor is ach&#305;eved with synchronized and low harmon&#305;c content grid current.</p><p>The experimental results are shown in Fig. <ref type="figure">6</ref> -12. The grid voltage, the grid current and three output DC cell voltages are given in Fig. <ref type="figure">6</ref>. The dynamic performance of the system was evaluated for both load step up and step down. It is shown that the converter maintains good transient performance and there is no disturbance in the grid current. The overshoot and undershoot during load steps in the DC bus voltages are approximately 5%. The overall strategy provides fast recovery during transients.</p><p>The output DC voltage (Ch. 3), the grid voltage (Ch. 1), and current (Ch. 2) waveforms are given in Fig. <ref type="figure">7</ref>. It is seen that the current drawn from the grid is in sinusoidal waveform and in phase with the grid voltage. The harmonics content of the current signal is low. Besides, the DC output voltages also track their references. Fig. <ref type="figure">8</ref> shows the three output DC bus voltages.   In Fig. <ref type="figure">10</ref> and 11, the DC voltages of each module and grid current are zoomed in at the transition of the step load to provide better observation of the dynamic performance of the controller. It is clear that the grid current is in sinusoidal waveform even during the transients, and synchronous with the grid phase and frequency. Thus, it is evident that unity power factor is achieved. In addition, the proposed control approach provides fast transient response and suppress the oscillations on the output DC voltage and the grid current. Moreover, the LCL filter resonnat is also suppressed with proposed current controller. The system can offers robust performance. The grid voltage and current are given at the step change instants in Fig. <ref type="figure">12</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>V. CONCLUSION</head><p>In this study, the SMC scheme has been applied to a singlephase CHB mult&#305;level AFE rectifier. A PI controller was used to control the voltage and generate the amplitude of the current reference signal. By using the PLL system, the grid current reference, which is tracked by the SMC controller, is obtained. The grid current and capacitor voltage of the LCL filter are used as feedback signals. The proposed controller was validated through simulation and the presented experimental results. The simulation and experimental results show that the rectifier current drawn from the grid is in phase with the grid voltage, is in sinusoidal waveform, and has a THD level of 1.81%. Additionally, the resonance of the LCL filter is also damped without any additional active and passive damping methods. This CHM multilevel AFE rectifier with multiple output DC voltages is a suitable topology for high power direct medium voltage connected solid-state transformer applications, especially when secondary side of the multiple transformer units are connected in parallel to achieve desired power.</p></div></body>
		</text>