Title: Seismic and Durability Assessment of Externally Bonded FRP Retrofits in Reinforced Concrete Structures After 2018 Anchorage, AK Earthquake
Externally bonded fiber-reinforced polymer (EBFRP) composites are a cost-effective material used for repair and seismic retrofit of existing concrete structures. Even though EBFRP composites have been extensively utilized over the past 20 years as seismic retrofits, there are few data documenting their performance in a real shaking event or after long-term use on concrete structures. In this study, semi-destructive and non-destructive techniques were employed to evaluate the performance and durability of EBFRP-retrofitted buildings that had experienced the 2018 Cook Inlet Earthquake in Anchorage, AK. The performance of EBFRP was evaluated and documented through photographic evidence. Acoustic sounding, infrared thermography, and bond pull-off tests were utilized to evaluate the quality of bonding between the EBFRP and concrete. EBFRP samples were also collected from building interiors and exteriors for chemical and thermal analysis to evaluate the long-term effects of environmental exposure. Although environmental conditions were found to influence the bond quality between the EBFRP composite and concrete substrate, no major signs of earthquake damage to the building components retrofitted with EBFRP were noted. Materials characterization results demonstrated no evidence of polymer matrix degradation in exterior EBFRP samples.  more » « less
Award ID(s):
1916972
PAR ID:
10326979
Author(s) / Creator(s):
; ; ; ; ;
Editor(s):
Ilki, Alper; Ispir, Medine; Inci, Pinar
Date Published:
Journal Name:
CICE 2021: 10th International Conference on FRP Composites in Civil Engineering
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    As part of the effort to improve the seismic performance of buildings in Alaska (AK), many of the deficient structures in Anchorage, AK, were retrofitted—some with externally bonded fiber-reinforced polymer (EBFRP) composite systems. The 2018 magnitude 7.1 Cook Inlet earthquake that impacted the same region offered an opportunity to evaluate the performance of EBFRP retrofits in a relatively high-intensity earthquake. This study summarizes the following findings of this field investigation: (1) the performance of EBFRP-retrofitted structures in the Cook Inlet earthquake and (2) the observations concerning the condition of FRP retrofits from over a decade of exposure in a subarctic environment. A deployment team from the National Institute of Standards and Technology (NIST) in collaboration with the University of Delaware (UD) Center for Composite Materials conducted post-earthquake inspections of EBFRP retrofits in multiple buildings to assess their performance during the earthquake and condition with respect to weathering. EBFRP debonding was documented with infrared thermography and acoustic sounding and the bond quality between EBFRP and concrete was assessed using pull-off tests. Visual inspections showed no major signs of earthquake damage in the EBFRP-retrofitted components. However, evaluation of debonding and pull-off test results suggested that outdoor conditions may have led to bond deterioration between EBFRP and concrete from installation defects that grew over time, freeze–thaw expansion from moisture present at the FRP/concrete interface, differences in thermal expansion of the materials, or a combination thereof. The carbon fiber–reinforced polymer (CFRP) bond to concrete was found to be more vulnerable to outdoor exposure than the glass fiber–reinforced polymer (GFRP) bond. Earthquake effects on FRP/concrete bond could not be assessed due to the lack of baseline data. 
    more » « less
  2. Frigione, Mariaenrica (Ed.)
    Externally bonded fiber-reinforced polymer composites have been in use in civil infrastructure for decades, but their long-term performance is still difficult to predict due to many knowledge gaps in the understanding of degradation mechanisms. This paper summarizes critical durability issues associated with the application of fiber-reinforced polymer (FRP) composites for rehabilitation of concrete structures. A variety of factors that affect the longevity of FRP composites are discussed: installation, quality control, material selection, and environmental conditions. Critical review of design approaches currently used in various international design guidelines is presented to identify potential opportunities for refinement of design guidance with respect to durability. Interdisciplinary approaches that combine materials science and structural engineering are recognized as having potential to develop composites with improved durability. 
    more » « less
  3. Pultruded FRP composites have emerged as a promising alternative to traditional materials like concrete, steel, and timber, especially in corrosive environmental conditions. However, the unique properties of these composites necessitate careful consideration during their implementation, as they differ significantly from conventional materials. Proper testing and characterization of FRP pultruded materials is key for their efficient and safe implementation. However, the existing specifications are not unified, resulting in ambiguity among stakeholders. This paper aims to bridge this gap by thoroughly reviewing current destructive and non-destructive test methods for FRP pultruded materials, specifications, quality control, and health monitoring of FRP structures. Each subsection is further divided into subtopics, providing a comprehensive overview of the subject. By shedding light on these crucial aspects, this article aims to accelerate the adoption and utilization of these innovative materials in practical applications. 
    more » « less
  4. This study assesses physical and chemical properties of fiber reinforced polymer (FRP) composite materials aged in Alaska’s subarctic climate. Carbon FRP (CFRP) and glass FRP (GFRP) samples were collected in 2019 from the exterior and interior of Ted Stevens International Airport (TSIA, retrofitted in 2008) and McKinley Tower (MKT, retrofitted in 2004). Differential scanning calorimetry (DSC) was used to measure glass transition temperature (Tg) and physical aging, FTIR and Raman spectroscopy were used to investigate potential chemical degradation and degree of cure, and scanning electron microscopy (SEM) to evaluate cross-sectional microstructure, respectively. The results indicate that exposure to the subarctic climate had minimal effect on the composites’ and chemical properties. The variability in fiber content at MKT and thermal properties at TSIA suggest there were likely some inconsistencies in the FRP installation that may affect load-carrying capacity. Furthermore, some microcracks were observed in the FRP retrofits which may have resulted from a combination of poor fiber impregnation and thermal cycling. 
    more » « less
  5. Interest in earthquake resilience has increased in recent years, and the use of building cluster performance objectives has been shown to be an effective method for evaluating the resilience of built environment. A building cluster is a portfolio of buildings that share the same role in a community; its performance objectives are defined by considering earthquake scenarios, hazard levels, and individual building performance. The methodology presented in this paper employs performance-based assessments to estimate the probability of achieving building cluster performance objectives immediately following a seismic event. It can be used to assess the immediate post-earthquake community resilience in five steps: 1) hazard analysis, 2) conditional assessment of individual building performance, 3) conditional assessment of building cluster performance, 4) building cluster performance assessment by aggregation, and 5) earthquake resilience assessment of building clusters considering all hazard levels of interest. The design and extreme hazard levels are formulated using ground motion records selected based on the conditional spectra considering characteristics of earthquake scenarios and spatial correlation. Three performance objectives are defined for both individual buildings and building clusters: functionality, safe and usable during repair, and collapse prevention. Two engineering demand parameters – the maximum transient and the permanent interstory drift indices – are used to estimate individual building performance. The probability of achieving building cluster performance objective is calculated using the total probability theorem. The application of the proposed methodology is demonstrated using two clusters of reinforced concrete buildings, corresponding to ASCE 7 Risk Category II and IV structures, in San Francisco, CA. 
    more » « less