skip to main content


Title: Fast extended depth of focus meta-optics for varifocal functionality

Extended depth of focus (EDOF) optics can enable lower complexity optical imaging systems when compared to active focusing solutions. With existing EDOF optics, however, it is difficult to achieve high resolution and high collection efficiency simultaneously. The subwavelength spacing of scatterers in a meta-optic enables the engineering of very steep phase gradients; thus, meta-optics can achieve both a large physical aperture and a high numerical aperture. Here, we demonstrate a fast(f/1.75)EDOF meta-optic operating at visible wavelengths, with an aperture of 2 mm and focal range from 3.5 mm to 14.5 mm (286 diopters to 69 diopters), which is a250×elongation of the depth of focus relative to a standard lens. Depth-independent performance is shown by imaging at a range of finite conjugates, with a minimum spatial resolution of9.84  μm(50.8 cycles/mm). We also demonstrate operation of a directly integrated EDOF meta-optic camera module to evaluate imaging at multiple object distances, a functionality which would otherwise require a varifocal lens.

 
more » « less
Award ID(s):
2127235
NSF-PAR ID:
10369465
Author(s) / Creator(s):
; ; ; ;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Photonics Research
Volume:
10
Issue:
3
ISSN:
2327-9125
Page Range / eLocation ID:
Article No. 828
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. We experimentally demonstrate a camera whose primary optic is a cannula/needle (diameter=0.22mmandlength=12.5mm) that acts as a light pipe transporting light intensity from an object plane (35 cm away) to its opposite end. Deep neural networks (DNNs) are used to reconstruct color and grayscale images with a field of view of 18° and angular resolution of∼<#comment/>0.4∘<#comment/>. We showed a large effective demagnification of127×<#comment/>. Most interestingly, we showed that such a camera could achieve close to diffraction-limited performance with an effective numerical aperture of 0.045, depth of focus∼<#comment/>16µ<#comment/>m, and resolution close to the sensor pixel size (3.2 µm). When trained on images with depth information, the DNN can create depth maps. Finally, we show DNN-based classification of the EMNIST dataset before and after image reconstructions. The former could be useful for imaging with enhanced privacy.

     
    more » « less
  2. High-resolution strain sensing based on long, high-finesse fiber Fabry–Perot interferometers (FFPIs) has been demonstrated with a special focus on the infrasonic frequency range. A novel dual-FFPI scheme allows the large environment-induced background at low frequencies to be suppressed, permitting high strain resolution limited only by excess electronic noise. Noise-equivalent strain resolution of257pε<#comment/>/√<#comment/>Hzhas been achieved at 6 mHz, and the resolution improves to∼<#comment/>200fε<#comment/>/√<#comment/>Hzbetween 4–20 Hz. Without the use of any additional optical frequency references and with only off-the shelf commercial components, these resolutions are much better than most in the prior reports. Especially, an improvement of a factor of 1.8 is achieved in comparison with the highest resolution reported so far near 5 Hz. The limiting factors of the current scheme have been analyzed in detail, and the application prospects have been demonstrated using an acoustic transducer. The work lays out the potential of using long FFPIs with high finesse for high-resolution fiber-optic sensing in the infrasonic frequency range.

     
    more » « less
  3. A lens performs an approximately one-to-one mapping from the object to the image plane. This mapping in the image plane is maintained within a depth of field (or referred to as depth of focus, if the object is at infinity). This necessitates refocusing of the lens when the images are separated by distances larger than the depth of field. Such refocusing mechanisms can increase the cost, complexity, and weight of imaging systems. Here we show that by judicious design of a multi-level diffractive lens (MDL) it is possible to drastically enhance the depth of focus by over 4 orders of magnitude. Using such a lens, we are able to maintain focus for objects that are separated by as large a distance as∼<#comment/>6min our experiments. Specifically, when illuminated by collimated light atλ<#comment/>=0.85µ<#comment/>m, the MDL produced a beam, which remained in focus from 5 to 1200 mm. The measured full width at half-maximum of the focused beam varied from 6.6 µm (5 mm away from the MDL) to 524 µm (1200 mm away from the MDL). Since the side lobes were well suppressed and the main lobe was close to the diffraction limit, imaging with a horizontal × vertical field of view of40∘<#comment/>×<#comment/>30∘<#comment/>over the entire focal range was possible. This demonstration opens up a new direction for lens design, where by treating the phase in the focal plane as a free parameter, extreme-depth-of-focus imaging becomes possible.

     
    more » « less
  4. A novel characterization method is proposed to extract the optical frequency field-effect mobility (μop,FE) of transparent conductive oxide (TCO) materials by a tunable silicon microring resonator with a heterogeneously integrated titanium-doped indium oxide(ITiO)/SiO2/siliconmetal–oxide–semiconductor (MOS) capacitor. By operating the microring in the accumulation mode, the quality factor and resonance wavelength shift are measured and subsequently used to derive theμop,FEin the ultra-thin accumulation layer. Experimental results demonstrate that theμop,FEof ITiO increases from 25.3 to38.4  cm2V1s1with increasing gate voltages, which shows a similar trend as that at the electric frequency.

     
    more » « less
  5. We design and characterize a novel axilens-based diffractive optics platform that flexibly combines efficient point focusing and grating selectivity and is compatible with scalable top-down fabrication based on a four-level phase mask configuration. This is achieved using phase-modulated compact axilens devices that simultaneously focus incident radiation of selected wavelengths at predefined locations with larger focal depths compared with traditional Fresnel lenses. In addition, the proposed devices are polarization-insensitive and maintain a large focusing efficiency over a broad spectral band. Specifically, here we discuss and characterize modulated axilens configurations designed for long-wavelength infrared (LWIR) in the 6 µm–12 µm wavelength range and in the 4 µm–6 µm midwavelength infrared (MWIR) range. These devices are ideally suited for monolithic integration atop the substrate layers of infrared focal plane arrays and for use as compact microspectrometers. We systematically study their focusing efficiency, spectral response, and cross-talk ratio; further, we demonstrate linear control of multiwavelength focusing on a single plane. Our design method leverages Rayleigh–Sommerfeld diffraction theory and is validated numerically using the finite element method. Finally, we demonstrate the application of spatially modulated axilenses to the realization of a compact, single-lens spectrometer. By optimizing our devices, we achieve a minimum distinguishable wavelength interval ofΔ<#comment/>λ<#comment/>=240nmatλ<#comment/>c=8µ<#comment/>mandΔ<#comment/>λ<#comment/>=165nmatλ<#comment/>c=5µ<#comment/>m. The proposed devices add fundamental spectroscopic capabilities to compact imaging devices for a number of applications ranging from spectral sorting to LWIR and MWIR phase contrast imaging and detection.

     
    more » « less