skip to main content


Title: Small‐diameter artery decellularization: Effects of anionic detergent concentration and treatment duration on porcine internal thoracic arteries
Abstract

Engineered replacement materials have tremendous potential for vascular applications where over 400,000 damaged and diseased blood vessels are replaced annually in the United States alone. Unlike large diameter blood vessels, which are effectively replaced by synthetic materials, prosthetic small‐diameter vessels are prone to early failure, restenosis, and reintervention surgery. We investigated the differential response of varying 0%–6% sodium dodecyl sulfate and sodium deoxycholate anionic detergent concentrations after 24 and 72 h in the presence of DNase using biochemical, histological, and biaxial mechanical analyses to optimize the decellularization process for xenogeneic vascular tissue sources, specifically the porcine internal thoracic artery (ITA). Detergent concentrations greater than 1% were successful at removing cytoplasmic and cell surface proteins but not DNA content after 24 h. A progressive increase in porosity and decrease in glycosaminoglycan (GAG) content was observed with detergent concentration. Augmented porosity was likely due to the removal of both cells and GAGs and could influence recellularization strategies. The treatment duration on the other hand, significantly improved decellularization by reducing DNA content to trace amounts after 72 h. Prolonged treatment times reduced laminin content and influenced the vessel's mechanical behavior in terms of altered circumferential stress and stretch while further increasing porosity. Collectively, DNase with 1% detergent for 72 h provided an effective and efficient decellularization strategy to be employed in the preparation of porcine ITAs as bypass graft scaffolding materials with minor biomechanical and histological penalties.

 
more » « less
PAR ID:
10363519
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Journal of Biomedical Materials Research Part B: Applied Biomaterials
Volume:
110
Issue:
4
ISSN:
1552-4973
Page Range / eLocation ID:
p. 885-897
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. ABSTRACT

    The temporomandibular joint disk (TMJd) is an extremely dense and avascular fibrocartilaginous extracellular matrix (ECM) resulting in a limited regenerative capacity. The use of decellularized TMJdas a biocompatible scaffold to guide tissue regeneration is restricted by innate subcellular porosity of the ECM that hinders cellular infiltration and regenerative events. Incorporation of an artificial microporosity through laser micro‐ablation (LMA) can alleviate these cell and diffusion based limitations. In this study, LMA was performed either before or after decellularization to assess to effect of surfactant treatment on porosity modification as well as the resultant mechanical and physical scaffold properties. Under convective flow or agitation schemes, pristine and laser ablated disks were decellularized using either low (0.1% w/v) or high (1% w/v) concentrations of sodium dodecyl sulfate (SDS). Results show that lower concentrations of SDS minimized collagen degradation and tissue swelling while retaining its capacity to solubilize cellular content. Regardless of processing scheme, laser ablated channels incorporated after SDS treatment were relatively smaller and more uniform than those incorporated before SDS treatment, indicating an altered laser interaction with surfactant treated tissues. Smaller channels correlated with less disruption of native biomechanical properties indicating surfactant pre‐treatment is an important consideration when using LMA to produce artificial porosity inex vivoderived tissues. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1858–1868, 2018.

     
    more » « less
  2. Abstract Photocoagulation of blood vessels offers unambiguous advantages to current radiofrequency approaches considering the high specificity of blood absorption at available laser wavelengths (e.g., 532 nm and 1.064 µm). Successful treatment of pediatric vascular lesions, such as port-wine stains requiring microvascular hemostasis, has been documented. Although laser treatments have been successful in smaller diameter blood vessels, photocoagulation of larger sized vessels is less effective. The hypothesis for this study is that a primary limitation in laser coagulation of large diameter blood vessels (500–1000 µm) originates from shear stress gradients associated with higher flow velocities along with temperature-dependent viscosity changes. Laser (1.07 µm) coagulation of blood vessels was tested in the chicken chorio-allantoic membrane (CAM). A finite element model is developed that includes hypothetical limitations in laser coagulation during irradiation. A protocol to specify laser dosimetry is derived from OCT imaging and angiography observations as well as finite element model results. Laser dosimetry is applied in the CAM model to test the experimental hypothesis that blood shear stress and flow velocity are important parameters for laser coagulation and hemostasis of large diameter blood vessels (500–1000 µm). Our experimental results suggest that shear stress and flow velocity are fundamental in the coagulation of large diameter blood vessels (500–1000 µm). Laser dosimetry is proposed and demonstrated for successful coagulation and hemostasis of large diameter CAM blood vessels. 
    more » « less
  3. Mechanical or biological aortic valves are incorporated in physical cardiac simulators for surgical training, educational purposes, and device testing. They suffer from limitations including either a lack of anatomical and biomechanical accuracy or a short lifespan, hence limiting the authentic hands-on learning experience. Medical schools utilize hearts from human cadavers for teaching and research, but these formaldehyde-fixed aortic valves contort and stiffen relative to native valves. Here, we compare a panel of different chemical treatment methods on explanted porcine aortic valves and evaluate the microscopic and macroscopic features of each treatment with a primary focus on mechanical function. A surfactant-based decellularization method after formaldehyde fixation is shown to have mechanical properties close to those of the native aortic valve. Valves treated in this method were integrated into a custom-built left heart cardiac simulator to test their hemodynamic performance. This decellularization, post-fixation technique produced aortic valves which have ultimate stress and elastic modulus in the range of the native leaflets. Decellularization of fixed valves reduced the valvular regurgitation by 60% compared to formaldehyde-fixed valves. This fixation method has implications for scenarios where the dynamic function of preserved valves is required, such as in surgical trainers or device test rigs. 
    more » « less
  4. Abstract Objective

    To characterize ossified bone marrow blood vessels and confirm the presence of ossified particles (OSP) in humans and rodents.

    Methods

    Human bone marrow blood vessels were processed for scanning and transmission electron microscopy. Whole blood samples were collected from younger (26‐39 years; n = 6) and older (55‐63 years; n = 6) volunteers and male Fischer‐344 rats (1 month, n = 7; 6 months, n = 7; 12 months, n = 7; 18‐months, n = 6; 24 months, n = 8).OSPin the whole blood samples were sorted and imaged with microscopy to determine diameter, circularity, and solidity. Additionally, the chemical composition ofOSPwas determined via elemental analysis.

    Results

    SEMrevealed two types of ossified bone marrow blood vessels: that is, “transitioning” and “ossified.”OSPwere adhered to the surface of transitioning vessels and theoretically gain access to and circulate within the blood. The majority ofOSPwere ≤15 μm in diameter, but many were of sufficient size to serve as emboli (ie, >15 μm).OSPwere predominately oblong in shape and several had jagged tips and edges.

    Conclusions

    We introduce a novel, bone‐like blood particle that may be diagnostic of bone marrow blood vessel ossification. Further,OSPmay associate with several disease states (eg, atherosclerosis).

     
    more » « less
  5. Minimally invasive endovascular therapy (MIET) is an innovative technique that utilizes percutaneous access and transcatheter implantation of medical devices to treat vascular diseases. However, conventional devices often face limitations such as incomplete or suboptimal treatment, leading to issues like recanalization in brain aneurysms, endoleaks in aortic aneurysms, and paravalvular leaks in cardiac valves. In this study, we introduce a new metastructure design for MIET employing re-entrant honeycomb structures with negative Poisson's ratio (NPR), which are initially designed through topology optimization and subsequently mapped onto a cylindrical surface. Using ferromagnetic soft materials, we developed structures with adjustable mechanical properties called magnetically activated structures (MAS). These magnetically activated structures can change shape under noninvasive magnetic fields, letting them fit against blood vessel walls to fix leaks or movement issues. The soft ferromagnetic materials allow the stent design to be remotely controlled, changed, and rearranged using external magnetic fields. This offers accurate control over stent placement and positioning inside blood vessels. We performed magneto-mechanical simulations to evaluate the proposed design's performance. Experimental tests were conducted on prototype beams to assess their bending and torsional responses to external magnetic fields. The simulation results were compared with experimental data to determine the accuracy of the magneto-mechanical simulation model for ferromagnetic soft materials. After validating the model, it was used to analyze the deformation behavior of the plane matrix and cylindrical structure designs of the Negative Poisson's Ratio (NPR) metamaterial. The results indicate that the plane matrix NPR metamaterial design exhibits concurrent vertical and horizontal expansion when subjected to an external magnetic field. In contrast, the cylindrical structure demonstrates simultaneous axial and radial expansion under the same conditions. The preliminary findings demonstrate the considerable potential and practicality of the proposed methodology in the development of magnetically activated MIET devices, which offer biocompatibility, a diminished risk of adverse reactions, and enhanced therapeutic outcomes. Integrating ferromagnetic soft materials into mechanical metastructures unlocks promising opportunities for designing stents with adjustable mechanical properties, propelling the field towards more sophisticated minimally invasive vascular interventions. 
    more » « less