The goal of this study was to conceptualize and compute measures of “mechanical work” done by the esophagus using data generated during functional lumen imaging probe (FLIP) panometry and compare work done during secondary peristalsis among patients and controls. Eighty-five individuals were evaluated with a 16-cm FLIP during sedated endoscopy, including asymptomatic controls ( n = 14) and those with achalasia subtypes I, II, and III ( n = 15, each); gastroesophageal reflux disease (GERD; n = 13); eosinophilic esophagitis (EoE; n = 9); and systemic sclerosis (SSc; n = 5). The FLIP catheter was positioned to have its distal segment straddling the esophagogastric junction (EGJ) during stepwise distension. Two metrics of work were assessed: “active work” (during bag volumes ≤ 40 mL where contractility generates substantial changes in lumen area) and “work capacity” (for bag volumes ≥ 60 mL when contractility cannot substantially alter the lumen area). Controls showed median [interquartile range (IQR)] of 7.3 (3.6–9.2) mJ of active work and 268.6 (225.2–332.3) mJ of work capacity. Patients with all achalasia subtypes, GERD, and SSc showed lower active work done than controls ( P ≤ 0.003). Patients with achalasia subtypes I and II, GERD, and SSc had lower work capacity compared with controls ( P < 0.001, 0.004, 0.04, and 0.001, respectively). Work capacity was similar between controls and patients with achalasia type III and EoE. Mechanical work of the esophagus differs between healthy controls and patient groups with achalasia, EoE, SSc, and GERD. Further studies are needed to fully explore the utility of this approach, but these work metrics would be valuable for device design (artificial esophagus), to measure the efficacy of peristalsis, to gauge the physiological state of the esophagus, and to comment on its pumping effectiveness. NEW & NOTEWORTHY Functional lumen imaging probe (FLIP) panometry assesses esophageal response to distension and provides a simultaneous assessment of pressure and dimension during contractility. This enables an objective assessment of “mechanical work” done by the esophagus. Eighty-five individuals were evaluated, and two work metrics were computed for each subject. Controls showed greater values of work compared with individuals with achalasia, gastroesophageal reflux disease (GERD), and systemic sclerosis (SSc). These values can quantify the mechanical behavior of the distal esophagus and assist in the estimation of muscular integrity.
more »
« less
Estimation of mechanical work done to open the esophagogastric junction using functional lumen imaging probe panometry
In this study, we quantify the work done by the esophagus to open the esophagogastric junction (EGJ) and create a passage for bolus flow into the stomach. Work done on the EGJ was computed using functional lumen imaging probe (FLIP) panometry. Eighty-five individuals underwent FLIP panometry with a 16-cm catheter during sedated endoscopy including asymptomatic controls ( n = 14), 45 patients with achalasia ( n = 15 each, three subtypes), those with gastroesophageal reflux disease (GERD; n = 13), those with eosinophilic esophagitis (EoE; n = 8), and those with systemic sclerosis (SSc; n = 5). Luminal cross-sectional area (CSA) and pressure were measured by the FLIP catheter positioned across the EGJ. Work done on the EGJ (EGJW) was computed (millijoules, mJ) at 40-mL distension. Additionally, a separate method was developed to estimate the “work required” to fully open the EGJ (EGJROW) when it did not open during the procedure. EGJW for controls had a median [interquartile range (IQR)] value of 75 (56–141) mJ. All achalasia subtypes showed low EGJW compared with controls ( P < 0.001). Subjects with GERD and EoE had EGJW 54.1 (6.9–96.3) and 65.9 (10.8–102.3) mJ, similar to controls ( P < 0.08 and P < 0.4, respectively). The scleroderma group showed low values of EGJW, 12 mJ ( P < 0.001). For patients with achalasia, EGJROW was the greatest and had a value of 210.4 (115.2–375.4) mJ. Disease groups with minimal or absent EGJ opening showed low values of EGJW. For patients with achalasia, EGJROW significantly exceeded EGJW values of all other groups, highlighting its unique pathophysiology. Balancing the relationship between EGJW and EGJROW is potentially useful for calibrating achalasia treatments and evaluating treatment response. NEW & NOTEWORTHY Changes in pressure and diameter occur at the EGJ during esophageal emptying. Similar changes can be observed during FLIP panometry. Data from healthy and diseased individuals were used to estimate the mechanical work done on the EGJ during distension-induced relaxation or, in instances of failed opening, work required to open the EGJ. Quantifying these parameters is potentially valuable to calibrate treatments and gauge treatment efficacy for subjects with disorders of EGJ function, especially achalasia.
more »
« less
- PAR ID:
- 10379205
- Date Published:
- Journal Name:
- American Journal of Physiology-Gastrointestinal and Liver Physiology
- Volume:
- 320
- Issue:
- 5
- ISSN:
- 0193-1857
- Page Range / eLocation ID:
- G780 to G790
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Enhancing Chicago Classification diagnoses with functional lumen imaging probe—mechanics (FLIP‐MECH)Abstract BackgroundEsophageal motility disorders can be diagnosed by either high‐resolution manometry (HRM) or the functional lumen imaging probe (FLIP) but there is no systematic approach to synergize the measurements of these modalities or to improve the diagnostic metrics that have been developed to analyze them. This work aimed to devise a formal approach to bridge the gap between diagnoses inferred from HRM and FLIP measurements using deep learning and mechanics. MethodsThe “mechanical health” of the esophagus was analyzed in 740 subjects including a spectrum of motility disorder patients and normal subjects. The mechanical health was quantified through a set of parameters including wall stiffness, active relaxation, and contraction pattern. These parameters were used by a variational autoencoder to generate a parameter space called virtual disease landscape (VDL). Finally, probabilities were assigned to each point (subject) on the VDL through linear discriminant analysis (LDA), which in turn was used to compare with FLIP and HRM diagnoses. ResultsSubjects clustered into different regions of the VDL with their location relative to each other (and normal) defined by the type and severity of dysfunction. The two major categories that separated best on the VDL were subjects with normal esophagogastric junction (EGJ) opening and those with EGJ obstruction. Both HRM and FLIP diagnoses correlated well within these two groups. ConclusionMechanics‐based parameters effectively estimated esophageal health using FLIP measurements to position subjects in a 3‐D VDL that segregated subjects in good alignment with motility diagnoses gleaned from HRM and FLIP studies.more » « less
-
The esophagogastric junction (EGJ) is located at the distal end of the esophagus and acts as a valve allowing swallowed food to enter the stomach and preventing acid reflux. Irregular weakening or stiffening of the EGJ muscles results in changes to its opening and closing patterns which can progress into esophageal disorders. Therefore, understanding the physics of the opening and closing cycle of the EGJ can provide mechanistic insights into its function and can help identify the underlying conditions that cause its dysfunction. Using clinical functional lumen imaging probe (FLIP) data, we plotted the pressure-cross-sectional area loops at the EGJ location and distinguished two major loop types—a pressure dominant loop and a tone dominant loop. In this study, we aimed to identify the key characteristics that define each loop type and determine what causes the inversion from one loop to another. To do so, the clinical observations are reproduced using 1D simulations of flow inside a FLIP device located in the esophagus, and the work done by the EGJ wall over time is calculated. This work is decomposed into active and passive components, which reveal the competing mechanisms that dictate the loop type. These mechanisms are esophageal stiffness, fluid viscosity, and the EGJ relaxation pattern.more » « less
-
Abstract Functional luminal imaging probe (FLIP) is used to measure cross-sectional area (CSA) and pressure at sphincters. It consists of a catheter surrounded by a fluid filled cylindrical bag, closed on both ends. Plotting the pressure-CSA hysteresis of a sphincter during a contraction cycle, which is available through FLIP testing, offers information on its functionality, and can provide diagnostic insights. However, limited work has been done to explain the mechanics of these pressure-CSA loops. This work presents a consolidated picture of pressure-CSA loops of different sphincters. Clinical data reveal that although sphincters have a similar purpose (controlling the flow of liquids and solids by opening and closing), two different pressure-CSA loop patterns emerge: negative slope loop (NSL) and positive slope loop (PSL). We show that the loop type is the result of an interplay between (or lack thereof) two mechanical modes: (i) neurogenic mediated relaxation of the sphincter muscle or pulling applied by external forces, and (ii) muscle contraction proximal to the sphincter which causes mechanical distention. We conclude that sphincters which only function through mechanism (i) exhibition NSL whereas sphincters which open as a result of both (i) and (ii) display a PSL. This work provides a fundamental mechanical understanding of human sphincters. This can be used to identify normal and abnormal phenotypes for the different sphincters and help in creating physiomarkers based on work calculation.more » « less
-
This study investigated the heterogeneity of ocular hemodynamic biomarkers in early open angle glaucoma (OAG) patients and healthy controls of African (AD) and European descent (ED). Sixty OAG patients (38 ED, 22 AD) and 65 healthy controls (47 ED, 18 AD) participated in a prospective, cross-sectional study assessing: intraocular pressure (IOP), blood pressure (BP), ocular perfusion pressure (OPP), visual field (VF) and vascular densities (VD) via optical coherence tomography angiography (OCTA). Comparisons between outcomes were adjusted for age, diabetes status and BP. VF, IOP, BP and OPP were not significantly different between OAG subgroups or controls. Multiple VD biomarkers were significantly lower in OAG patients of ED (p < 0.05) while central macular VD was lower in OAG patients of AD vs. OAG patients of ED (p = 0.024). Macular and parafoveal thickness were significantly lower in AD OAG patients compared to those of ED (p = 0.006–0.049). OAG patients of AD had a negative correlation between IOP and VF index (r = −0.86) while ED patients had a slightly positive relationship (r = 0.26); difference between groups (p < 0.001). Age-adjusted OCTA biomarkers exhibit significant variation in early OAG patients of AD and ED.more » « less