Title: A Low-Cost Solution for Documenting, Tracking, and Verifying Cage-Level Animal Husbandry Tasks Using Wireless QR Scanners and Cloud-Based Spreadsheets
Animal care is a critical component underlying successful behavioral and cognition research. Technological solutions for documentation and verification of care can aid in monitoring that activities are completed according to standard operating procedures and ensure that no individuals are overlooked. Here, I summarize a low-cost, flexible, and easy to use system that I developed to document and monitor care of animals for our research group. The system enables real-time and remote-enabled verification that critical daily tasks have been completed for every cage and helps us monitor our longer-term tasks to make sure that our care team is adhering to our set schedule. The main materials and components needed to implement this system are QR codes, a thermal laminator, a QR scanner, a computer to manage data input, and a database into which the data are scanned and summarized. There are six steps to setting up our system: (1) purchase a QR scanner, (2) generate and print QR codes, (3) set up the central hub for data input, (4) input data from QR scans, (5) filter and collate the raw data, and (6) summarize filtered data to verify and track care. Paired with simple scripts in a cloud-based spreadsheet, scanned QR code data can then be easily summarized in real time to provide verification of care. The flexibility of the system allows it to be customized to a large range of species.  more » « less
Award ID(s):
2015932
PAR ID:
10385958
Author(s) / Creator(s):
Date Published:
Journal Name:
Animal Behavior and Cognition
Volume:
9
Issue:
4
ISSN:
2372-5052
Page Range / eLocation ID:
416 to 427
Subject(s) / Keyword(s):
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Background Clinical alarm system safety is a national patient safety goal in the United States. Physiologic monitors are associated with the highest number of device alarms and alarm-related deaths. However, research involving nurses’ use of physiologic monitors is rare. Hence, the identification of critical usability issues for monitors, especially those related to patient safety, is a nursing imperative. Objective This study examined nurses’ usability of physiologic monitors in intensive care units with respect to the effectiveness and efficiency of monitor use. Methods In total, 30 nurses from 4 adult intensive care units completed 40 tasks in a simulation environment. The tasks were common monitoring tasks that were crucial for appropriate monitoring and safe alarm management across four categories of competencies: admitting, transferring, and discharging patients using the monitors (7 tasks); managing measurements and monitor settings (23 tasks); performing electrocardiogram (ECG) analysis (7 tasks); and troubleshooting alarm conditions (3 tasks). The nurse-monitor interaction was video-recorded. The principal investigator and two expert intensive care units nurse educators identified, classified, and validated task success (effectiveness) and the time of task completion (efficiency). Results Among the 40 tasks, only 2 (5%) were successfully completed by all the nurses. At least 1-27 (3%-90%) nurses abandoned or did not correctly perform 38 tasks. The task with the shortest completion time was “take monitor out of standby” (mean 0:02, SD 0:01 min:s), whereas the task “record a 25 mm/s ECG strip of any of the ECG leads” had the longest completion time (mean 1:14, SD 0:32 min:s). The total time to complete 37 navigation-related tasks ranged from a minimum of 3 min 57 s to a maximum of 32 min 42 s. Regression analysis showed that it took 6 s per click or step to successfully complete a task. To understand the nurses’ thought processes during monitor navigation, the authors analyzed the paths of the 2 tasks with the lowest successful completion rates, where only 13% (4/30) of the nurses correctly completed these 2 tasks. Although 30% (9/30) of the nurses accessed the correct screen first for task 1 and task 2, they could not find their way easily from there to successfully complete the 2 tasks. Conclusions Usability testing of physiologic monitors revealed major ineffectiveness and inefficiencies in the current nurse-monitor interactions. The results indicate the potential for safety and productivity issues in completing routine tasks. Training on monitor use should include critical monitoring functions that are necessary for safe, effective, efficient, and appropriate monitoring to include knowledge of the shortest navigation path. It is imperative that vendors’ future monitor designs mimic clinicians’ thought processes for successful, safe, and efficient monitor navigation. 
    more » « less
  2. We conducted a field experiment involving the purchase of oysters to offer market-based evidence on whether consumers will scan quick response (QR) codes on food packages, a new labeling technology proposed by the SmartLabelTM initiative. In an artefactual marketplace selling oysters, only 1.2% participants scanned the QR code labels with their own devices. However, providing free access to a QR-scanning smartphone induced 52.6% of participants to access labeling information—a large improvement even compared to when this information was provided directly on the package. Furthermore, consumers’ responses to the additional information were similar regardless of how the information was delivered. 
    more » « less
  3. null (Ed.)
    International Ocean Discovery Program (IODP) Expedition 363 recovered extended Neogene to Quaternary carbonate- and clay-rich sedimentary successions at Site U1482 (15°3.32ʹS, 120°26.10ʹE; 1466 m water depth), drilled at the southwestern edge of the Indo-Pacific Warm Pool off northwest Australia (Rosenthal et al., 2018b). Four holes were drilled with the advanced piston corer (APC) system at this site and deepened with the half-length APC (HLAPC) and extended core barrel (XCB) systems. A shipboard splice, from 0 to 451.26 m core composite depth below seafloor (CCSF), was established. After the expedition, the cores were scanned at high-resolution (1–2 cm) using an Avaatech X-ray fluorescence (XRF) core scanner. Scanning was performed along the shipboard splice with approximately 1 m overlap at the splice tie points for verification. Based on this new data set, we revised nine of the original splice tie points. The revised splice for Site U1482 now extends to 445.11 m revised CCSF and is available from the IODP Laboratory Information Management System (LIMS) database. 
    more » « less
  4. ABSTRACT Covert patterns have an extra layer of security protection for anti‐counterfeiting labels as compared with the traditional overt ones. To increase the complexity and security of quick response (QR) codes, it would be valuable to make covert QR codes that will be only scannable after a certain decoding process. In this work, the use of surface‐enhanced Raman spectroscopy (SERS) is explored to fabricate covert QR codes. Through developing new Raman‐active security inks, we can prepare covert QR codes using a convenient inkjet printing method. These QR codes will not be revealed directly. They can only be decoded using a confocal Raman microscope. In addition, multiplex QR codes can be accomplished using multiple Raman probes in printing. Our results showed that the printed QR codes are covert, have strong SERS signals, and can be easily recognized after the SERS decoding. It is anticipated that there is great potential for using such covert and multiplexed SERS‐based QR codes for advanced anti‐counterfeiting applications. 
    more » « less
  5. QR Codes have become a pervasive mechanism for encoding machine-readable digital data in the offline world. As the Internet age has taught us, mechanisms that become pervasive very often engender privacy concerns regarding their use. As such, here we conduct an investigation of the privacy implications of the QR Code ecosystem as it exists today. We find that there are several shortener services with substantial popularity, and investigate the extent to which these shortener services conduct various types of tracking of individuals who interact with the created QR Codes. Additionally, we collect 948 QR codes posted within the world, and evaluate them for various types of tracking as well. Overall, we find no evidence that QR codes are a substantial or unique privacy threat when compared to other link sharing mechanisms available online. Even so, the theoretical potential for surreptitious tracking exists, and more in depth study of the QR Code ecosystem will allow for deeper investigation of the relationship between online and offline tracking. 
    more » « less