Title: Portable mass spectrometry system: instrumentation, applications, and path to ‘omics analysis
Abstract

Mass spectrometry (MS) is an information rich analytical technique and plays a key role in various ‘omics studies. Standard mass spectrometers are bulky and operate at high vacuum, which hinder their adoption by the broader community and utility in field applications. Developing portable mass spectrometers can significantly expand the application scope and user groups of MS analysis. This review discusses the basics and recent advancements in the development of key components of portable mass spectrometers including ionization source, mass analyzer, detector, and vacuum system. Further, major areas where portable mass spectrometers are applied are also discussed. Finally, a perspective on the further development of portable mass spectrometers including the potential benefits for ‘omics analysis is provided.

 
more » « less
NSF-PAR ID:
10386238
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
PROTEOMICS
Volume:
22
Issue:
23-24
ISSN:
1615-9853
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Rationale

    New ionization processes have been developed for biological mass spectrometry (MS) in which the matrix lifts the nonvolatile analyte into the gas phase as ions without any additional energy input. We rationalized that additional fundamental knowledge is needed to assess analytical utility for the field of synthetic polymers and additives.

    Methods

    Different mass spectrometers (Thermo Orbitrap (Q‐)Exactive (Focus); Waters SYNAPT G2(S)) were employed. The formation of multiply charged polymer ions upon exposure of the matrix/analyte(/salt) sample to sub‐atmospheric pressure directly from the solid state and surfaces facilitates the use of advanced mass spectrometers for detection of polymeric materials including consumer products (e.g., gum).

    Results

    Astonishingly, using nothing more than a small molecule matrix compound (e.g., 2‐methyl‐2‐nitropropane‐1,3‐diol or 3‐nitrobenzonitrile) and a salt (e.g., mono‐ or divalent cation(s)), such samples upon exposure to sub‐atmospheric pressure transfer nonvolatile polymersandnonvolatile salts into the gas phase as multiply charged ions. These successes contradict the conventional understanding of ionization in MS, because can nonvolatile polymers be lifted in the gas phase as ions not only by as little as a volatile matrix but also by the salt required for ionizing the analyte through noncovalent metal cation adduction(s). Prototypevacuummatrix‐assisted ionization (vMAI) and automated sources using a contactless approach are demonstrated for direct analyses of synthetic polymers and plasticizers, minimizing the risk of contamination using direct sample introduction into the mass spectrometer vacuum.

    Conclusions

    Direct ionization methods from surfaces without the need of high voltage, a laser, or even applied heat are demonstrated for characterization of detailed materials using (ultra)high‐resolution and accurate mass measurements enabled by the multiply charged ions extending the mass range of high‐performance mass spectrometers and use of a split probe sample introduction device. Our vision is that, with further development of fundamentals and dedicated sources, both spatial‐ and temporal‐resolution measurements are within reach if sensitivity is addressed for decreasing sample‐size measurements.

     
    more » « less
  2. Rationale

    The developments of new ionization technologies based on processes previously unknown to mass spectrometry (MS) have gained significant momentum. Herein we address the importance of understanding these unique ionization processes, demonstrate the new capabilities currently unmet by other methods, and outline their considerable analytical potential.

    Methods

    Theinletandvacuumionization methods of solvent‐assisted ionization (SAI), matrix‐assisted ionization (MAI), and laserspray ionization can be used with commercial and dedicated ion sources producing ions from atmospheric or vacuum conditions for analyses of a variety of materials including drugs, lipids, and proteins introduced from well plates, pipet tips and plate surfaces with and without a laser using solid or solvent matrices. Mass spectrometers from various vendors are employed.

    Results

    Results are presented highlighting strengths relative to ionization methods of electrospray ionization (ESI) and matrix‐assisted laser desorption/ionization. We demonstrate the utility of multi‐ionization platforms encompassing MAI, SAI, and ESI and enabling detection of what otherwise is missed, especially when directly analyzing mixtures. Unmatched robustness is achieved with dedicated vacuum MAI sources with mechanical introduction of the sample to the sub‐atmospheric pressure (vacuumMAI). Simplicity and use of a wide array of matrices are attained using a conduit (inletionization), preferably heated, with sample introduction from atmospheric pressure. Tissue, whole blood, urine (including mouse, chicken, and human origin), bacteria strains and chemical on‐probe reactions are analyzed directly and, especially in the case ofvacuumionization, without concern of carryover or instrument contamination.

    Conclusions

    Examples are provided highlighting the exceptional analytical capabilities associated with the novel ionization processes in MS that reduce operational complexity while increasing speed and robustness, achieving mass spectra with low background for improved sensitivity, suggesting the potential of this simple ionization technology to drive MS into areas currently underserved, such as clinical and medical applications.

     
    more » « less
  3. Rationale

    Examining surface protein conformations, and especially achieving this with spatial resolution, is an important goal. The recently discovered ionization processes offer spatial‐resolution measurements similar to matrix‐assisted laser desorption/ionization (MALDI) and produce charge states similar to electrospray ionization (ESI) extending higher‐mass protein applications directly from surfaces on high‐performance mass spectrometers. Studying a well‐interrogated protein by ion mobility spectrometry‐mass spectrometry (IMS‐MS) to access effects on structures using a solidvs.solvent matrix may provide insights.

    Methods

    Ubiquitin was studied by IMS‐MS using new ionization processes with commercial and homebuilt ion sources and instruments (Waters SYNAPT G2(S)) and homebuilt 2 m drift‐tube instrument; MS™ sources). Mass‐to‐charge and drift‐time (td)‐measurements are compared for ubiquitin ions obtained byinletandvacuumionization using laserspray ionization (LSI), matrix‐ (MAI) and solvent‐assisted ionization (SAI), respectively, and compared with those from ESI under conditions that are most comparable.

    Results

    Using the same solution conditions with SYNAPT G2(S) instruments, td‐distributions of various ubiquitin charge states from MAI, LSI, and SAI are similar to those from ESI using a variety of solvents, matrices, extraction voltages, a laser, and temperature only, showing subtle differences in more compact features within the elongated distribution of structures. However, on a homebuilt drift‐tube instrument, within the elongated distribution of structures, both similar and different td‐distributions are observed for ubiquitin ions obtained by MAI and ESI. MAI‐generated ions are frequently narrower in their td‐distributions.

    Conclusions

    Direct comparisons between ESI and the new ionization methods operational directly from surfaces suggest that the protein in its solution structure prior to exposure to the ionization event is either captured (frozen out) at the time of crystallization, or that the protein in the solid matrix is associated with sufficient solvent to maintain the solution structure, or, alternatively, that the observed structures are those related to what occurs in the gas phase with ESI‐ or MAI‐generated ions and not with the solution structures.

     
    more » « less
  4. Abstract

    Biopolymer analysis, including proteomics and glycomics, relies heavily on the use of mass spectrometry for structural elucidation, including sequence determination. Novel methods to improve sample workup, instrument performance, and data analysis continue to be developed to address shortcomings associated with sample preparation, analysis time, data quality, and data interpretation. Here, we present a new method that couples in‐source collision‐induced dissociation (IS‐CID) with two‐dimensional tandem mass spectrometry (2D MS/MS) as a way to simplify proteomics and glycomics workflows while also providing additional insight into analyte structures over traditional MS/MS experiments. Specifically, IS‐CID is employed as a gas‐phase digestion method, i.e., to break down intact full‐length polysaccharide or peptide ions prior to mass analysis. The resulting mixtures of oligomeric ions are analyzed by 2D‐MS/MS, a technique that allows association of product ions with their precursor ions without isolation of the latter. A novel data analysis strategy is introduced to leverage the second dimension of 2D MS/MS spectra, in which stairstep patterns, representing outputs of a molecule's MSnscans, are extracted for structural interconnectivity information on the oligomer. The results demonstrate the potential applicability of 2D MS/MS strategies to the modern omics workflow and structural analysis of various classes of biopolymers.

     
    more » « less
  5. Abstract

    Biopolymer analysis, including proteomics and glycomics, relies heavily on the use of mass spectrometry for structural elucidation, including sequence determination. Novel methods to improve sample workup, instrument performance, and data analysis continue to be developed to address shortcomings associated with sample preparation, analysis time, data quality, and data interpretation. Here, we present a new method that couples in‐source collision‐induced dissociation (IS‐CID) with two‐dimensional tandem mass spectrometry (2D MS/MS) as a way to simplify proteomics and glycomics workflows while also providing additional insight into analyte structures over traditional MS/MS experiments. Specifically, IS‐CID is employed as a gas‐phase digestion method, i.e., to break down intact full‐length polysaccharide or peptide ions prior to mass analysis. The resulting mixtures of oligomeric ions are analyzed by 2D‐MS/MS, a technique that allows association of product ions with their precursor ions without isolation of the latter. A novel data analysis strategy is introduced to leverage the second dimension of 2D MS/MS spectra, in which stairstep patterns, representing outputs of a molecule's MSnscans, are extracted for structural interconnectivity information on the oligomer. The results demonstrate the potential applicability of 2D MS/MS strategies to the modern omics workflow and structural analysis of various classes of biopolymers.

     
    more » « less