Title: Solid Contact Ion‐selective Electrodes on Printed Circuit Board with Membrane Displacement
Abstract Multiplexed solid‐contact ion‐selective electrodes (SCISEs) are fabricated using printed circuit board (PCB) and mesoporous carbon black (MCB) as ion‐to‐electron transducer (solid contact). Four sensor configurations were examined and showed that in addition to MCB, the sensor configuration plays crucial role in the stability of the potential response. The enhanced sensor stability was also linked with suppression of transmembrane flux of water. The sensors exhibited near‐Nernstian sensitivity (58.1 mV/dec for K+ISEs and −55.1 mV/dec for NO3ISEs), low detection limits (1.5–2.2 μM), and good short‐term stability (∼0.1 mV/min). Sensors can be stored dry and used without preconditioning. This work demonstrates a promising approach to combining PCB technology and carbon black for large‐scale production of low cost ISEs for point‐of‐care testing, wearables, orin situfield measurements.  more » « less
Award ID(s):
1841509 1841473
PAR ID:
10390437
Author(s) / Creator(s):
 ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Electroanalysis
Volume:
35
Issue:
1
ISSN:
1040-0397
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    We fabricated and evaluated multiplexed ion-selective electrodes (ISEs) by modifying printed circuit board (PCB). The multiplexed sensor consisted of all-solid-state K+ and NO3- ISEs, together with a Ag/AgCl reference. The sensor was further embedded in a microfluidic microchannel for in-line continuous analysis, and was characterized for up to one week of operation. Both ISEs showed a near-Nernstian response (~52 mV/dec) and reasonable stabilities (baseline drift ~2.9 mV/day). The sensor provides a versatile and low-cost tool for monitoring concentrations of different ions in many biomedical, environmental and agricultural applications. 
    more » « less
  2. We developed a potentiometric sensor system that includes a portable device and a multiplexed sensor based on solid-contact ion-selective electrodes (SCISE). SCISEs are fabricated using printed circuit board (PCB) and mesoporous carbon black (MCB) as the ion-to-electron transducer. The device supports sensor readout as well as automated sensor calibration, making it suitable for long term, in situ measurements. 
    more » « less
  3. We built an integrated solid-contact ion-selective electrode (SCISE) system with the functionality of self-calibration. A multiplexed SCISE sensor (K+ and NO3− vs. Ag/AgCl) was fabricated on printed-circuit board (PCB) substrates and was subsequently embedded into a microfluidic flow cell for self-calibration and flow-through analysis. A PCB circuit that includes modules for both sensor readout and fluid control was developed. The sensors showed a fast and near-Nernstian response (56.6 for the K+ electrode and −57.4 mV/dec for the NO3− electrode) and maintained their performance for at least three weeks. The sensors also showed a highly reproducible response in an automated two-point calibration, demonstrating the potential for in situ monitoring. Lastly, the sensor system was successfully applied to measure mineral nutrients in plant sap samples. 
    more » « less
  4. Abstract The ability to miniaturize ion‐selective sensors that enable microsensor arrays and wearable sensor patches for ion detection in environmental or biological samples requires all‐solid‐state sensors with solid contacts for transduction of an ion activity into an electrical signal. Nanostructured carbon materials function as effective solid contacts for this purpose. They can also contribute to improved potential signal stability, reducing the need for frequent sensor calibration. In this Perspective, the structural features of various carbon‐based solid contacts described in the literature and their respective abilities to reduce potential drift during long‐term, continuous measurements are compared. These carbon materials include nanoporous carbons with various architectures, carbon nanotubes, carbon black, graphene, and graphite‐based solid contacts. The effects of accessibility of ionophores, ionic sites, and other components of an ion‐selective membrane to the internal or external carbon surfaces are discussed, because this impacts double‐layer capacitance and potential drift. The effects of carbon composition on water‐layer formation are also considered, which is another contributor to potential drift during long‐term measurements. Recommendations regarding the selection of solid contacts and considerations for their characterization and testing in solid‐contact ion‐selective electrodes are provided. 
    more » « less
  5. Abstract Complex graphene electrode fabrication protocols including conventional chemical vapor deposition and graphene transfer techniques as well as more recent solution‐phase printing and postprint annealing methods have hindered the wide‐scale implementation of electrochemical devices including solid‐state ion‐selective electrodes (ISEs). Herein, a facile graphene ISE fabrication technique that utilizes laser induced graphene (LIG), formed by converting polyimide into graphene by a CO2laser and functionalization with ammonium ion (NH4+) and potassium ion (K+) ion‐selective membranes, is demonstrated. The electrochemical LIG ISEs exhibit a wide sensing range (0.1 × 10−3–150 × 10−3mfor NH4+and 0.3 × 10−3–150 × 10−3mfor K+) with high stability (minimal drop in signal after 3 months of storage) across a wide pH range (3.5–9.0). The LIG ISEs are also able to monitor the concentrations of NH4+and K+in urine samples (29–51% and 17–61% increase for the younger and older patient; respectively, after dehydration induction), which correlate well with conventional hydration status measurements. Hence, these results demonstrate a facile method to perform in‐field ion sensing and are the first steps in creating a protocol for quantifying hydration levels through urine testing in human subjects. 
    more » « less