Title: Customizable, reconfigurable, and anatomically coordinated large-area, high-density electromyography from drawn-on-skin electrode arrays
Abstract Accurate anatomical matching for patient-specific electromyographic (EMG) mapping is crucial yet technically challenging in various medical disciplines. The fixed electrode construction of multielectrode arrays (MEAs) makes it nearly impossible to match an individual's unique muscle anatomy. This mismatch between the MEAs and target muscles leads to missing relevant muscle activity, highly redundant data, complicated electrode placement optimization, and inaccuracies in classification algorithms. Here, we present customizable and reconfigurable drawn-on-skin (DoS) MEAs as the first demonstration of high-density EMG mapping from in situ-fabricated electrodes with tunable configurations adapted to subject-specific muscle anatomy. The DoS MEAs show uniform electrical properties and can map EMG activity with high fidelity under skin deformation-induced motion, which stems from the unique and robust skin-electrode interface. They can be used to localize innervation zones (IZs), detect motor unit propagation, and capture EMG signals with consistent quality during large muscle movements. Reconfiguring the electrode arrangement of DoS MEAs to match and extend the coverage of the forearm flexors enables localization of the muscle activity and prevents missed information such as IZs. In addition, DoS MEAs customized to the specific anatomy of subjects produce highly informative data, leading to accurate finger gesture detection and prosthetic control compared with conventional technology.  more » « less
Award ID(s):
2227063
PAR ID:
10391526
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ;
Editor(s):
Sharma, Pradeep
Date Published:
Journal Name:
PNAS Nexus
Volume:
2
Issue:
1
ISSN:
2752-6542
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract Cerebrovascular accidents like a stroke can affect the lower limb as well as upper extremity joints (i.e., shoulder, elbow, or wrist) and hinder the ability to produce necessary torque for activities of daily living. In such cases, muscles’ ability to generate forces reduces, thus affecting the joint’s torque production. Understanding how muscles generate forces is a key element to injury detection. Researchers have developed several computational methods to obtain muscle forces and joint torques. Electromyography (EMG) driven modeling is one of the approaches to estimate muscle forces and obtain joint torques from muscle activity measurements. Musculoskeletal models and EMG-driven models require necessary muscle-specific parameters for the calculation. The focus of this study is to investigate the EMG-driven approach along with an upper extremity musculoskeletal model to determine muscle forces of two major muscle groups, biceps brachii and triceps brachii, consisting of seven muscle-tendon units. Estimated muscle forces are used to determine the elbow joint torque. Experimental EMG signals and motion capture data are collected for a healthy subject. The musculoskeletal model is scaled to match the geometric parameters of the subject. Then, the approach calculates muscle forces and joint moment for two tasks: simple elbow flexion extension and triceps kickback. Individual muscle forces and net joint torques for both tasks are estimated. The study also has compared the effect of muscle-tendon parameters (optimal fiber length and tendon slack length) on the estimated results. 
    more » « less
  2. Converging evidence in human and animal models suggests that exogenous stimulation of the motor cortex (M1) elicits responses in the hand with similar modular structure to that found during voluntary grasping movements. The aim of this study was to establish the extent to which modularity in muscle responses to transcranial magnetic stimulation (TMS) to M1 resembles modularity in muscle activation during voluntary hand movements involving finger fractionation. EMG was recorded from eight hand-forearm muscles in nine healthy individuals. Modularity was defined using non-negative matrix factorization to identify low rank approximations (spatial muscle synergies) of the complex activation patterns of EMG data recorded during high density TMS mapping of M1 and voluntary formation of gestures in the American Sign Language alphabet. Analysis of synergies as a set, and individually, revealed greater than chance similarity between those derived from TMS and those derived from voluntary movement. Both datasets included synergies dominated by single intrinsic hand muscles presumably to meet the demand for highly fractionated finger movement. These results suggest a cortical role in combining corticospinal connectivity to individual intrinsic hand muscles with modular mulit-muscle activation via synergies. 
    more » « less
  3. ABSTRACT Relative to all other primates, the aye‐aye (Daubentonia madagascariensis) exists at the extremes of both morphology and behavior. Its specialized anatomy—which includes hypselodont incisors and highly derived manual digits—reflects a dietary niche, unique among primates, which combines tap‐foraging with gouging to locate and extract wood‐boring larvae. Here, we explore the impact of this extreme dietary ecology upon the masticatory musculature of this taxon with reference to a second, similarly sized but highly generalist lemuriform—the mongoose lemur (Eulemur mongoz). Using non‐destructive, high‐resolution diffusible iodine‐based contrast‐enhanced computed tomography techniques, we reconstruct the three‐dimensional volumes of eight masticatory muscles, and, for the first time in strepsirrhines, isolate and visualize their constituent muscle fasciclesin situand in three dimensions. Using these data, we report muscle volumes, forces, and fascicle lengths from each muscle portion, as well as their orientation relative to two standardized anatomical planes. Our findings demonstrate the overbuilt nature of the aye‐aye's masticatory apparatus, in which each muscle possesses an absolutely and relatively larger muscle volume and PCSA than its counterpart in the mongoose lemur. Likewise, for several adductor muscles, aye‐ayes also possess relatively greater fascicle lengths. Finally, we note several unusual features within the lateral pterygoid of the aye‐aye—the muscle most responsible for jaw protrusion—that relate to force maximization and reorientation. As this jaw motion is critical to gouging, we interpret these differences to reflect highly specific specializations that facilitate the aye‐aye's extreme subsistence strategy. Anat Rec, 2019. © 2019 American Association for Anatomy Anat Rec, 303:282–294, 2020. © 2019 American Association for Anatomy 
    more » « less
  4. Abstract Cardiac organoids have emerged as powerful platforms for modeling human heart development and disease. However, traditional 2D microelectrode arrays (MEAs) are limited to planar recordings and fail to capture the 3D propagation of electrical signals. Here, programmable, shape‐adaptive, organoid‐encapsulating shell MEAs are presented as a technology that enables comprehensive 3D electrophysiological mapping. These on‐chip‐fabricated devices feature customizable geometries and electrode layouts tailored to an organoid's unique morphology. Shell MEAs generate high‐resolution 3D isochrone and conduction velocity maps, unveiling long‐term spatiotemporal field potential dynamics in spontaneously beating organoids. Furthermore, they integrate multiple modalities, such as calcium imaging to corroborate electrophysiological findings and pharmacological screening to assess organoid responses to isoproterenol, E‐4031, and serotonin. This platform represents a significant advance in bioelectronic interfaces, enabling high‐content 3D spatiotemporal functional analysis for cardiac disease modeling and pharmacological testing. 
    more » « less
  5. Functional electrical stimulation (FES) is a vital method in neurorehabilitation used to reanimate paralyzed muscles, enhance the size and strength of atrophied muscles, and reduce spasticity. FES often leads to increased muscle fatigue, necessitating careful monitoring of the patient’s response. Ultrasound (US) imaging has been utilized to provide valuable insights into FES-induced fatigue by assessing changes in muscle thickness, stiffness, and strain. Current commercial FES electrodes lack sufficient US transparency, hindering the observation of muscle activity beneath the skin where the electrodes are placed. US-compatible electrodes are essential for accurate imaging and optimal FES performance, especially given the spatial constraints of conventional US probes and the need to monitor muscle areas directly beneath the electrodes. This study introduces specially designed body-conforming US-compatible FES (US-FES) electrodes constructed with a silver nanowire/polydimethylsiloxane (AgNW/PDMS) composite. We compared the performance of our body-conforming US-FES electrode with a commercial hydrogel electrode. The findings revealed that our US-FES electrode exhibited comparable conductivity and performance to the commercial one. Furthermore, US compatibility was investigated through phantom and in vivo tests, showing significant compatibility even during FES, unlike the commercial electrode. The results indicated that US-FES electrodes hold significant promise for the real-time monitoring of muscle activity during FES in clinical rehabilitative applications. 
    more » « less