LED array microscopy is an emerging platform for computational imaging with significant utility for biological imaging. Existing LED array systems often exploit transmission imaging geometries of standard brightfield microscopes that leave the rich backscattered field undetected. This backscattered signal contains high-resolution sample information with superb sensitivity to subtle structural features that make it ideal for biological sensing and detection. Here, we develop an LED array reflectance microscope capturing the sample’s backscattered signal. In particular, we demonstrate multimodal brightfield, darkfield, and differential phase contrast imaging on fixed and living biological specimens including
Fluorescence microscopy imaging of live cells has provided consistent monitoring of dynamic cellular activities and interactions. However, because current live-cell imaging systems are limited in their adaptability, portable cell imaging systems have been adapted by a variety of strategies, including miniaturized fluorescence microscopy. Here, we provide a protocol for the construction and operational process of miniaturized modular-array fluorescence microscopy (MAM). The MAM system is built in a portable size (15cm×15cm×3cm) and provides
- NSF-PAR ID:
- 10402698
- Publisher / Repository:
- Optical Society of America
- Date Published:
- Journal Name:
- Applied Optics
- Volume:
- 62
- Issue:
- 10
- ISSN:
- 1559-128X; APOPAI
- Format(s):
- Medium: X Size: Article No. 2456
- Size(s):
- Article No. 2456
- Sponsoring Org:
- National Science Foundation
More Like this
-
Caenorhabditis elegans (C. elegans) , zebrafish embryos, and live cell cultures. Video-rate multimodal imaging at 20 Hz records real time features of freely movingC. elegans and the fast beating heart of zebrafish embryos. Our new reflectance mode is a valuable addition to the LED array microscopic toolbox. -
In this Letter, we report a low-cost, portable, two-photon excitation fluorescence microscopy imager that uses a fiber-based approach for both femtosecond supercontinuum (SC) generation and light delivery to the optical head. The SC generation is based on a tapered polarization-maintaining photonic crystal fiber that uses pre-chirped femtosecond narrowband pulses to generate a coherent SC spectrum with a bandwidth of approximately 300 nm. Using this approach, high-power, near-transform-limited, wavelength-selectable SC pulses are generated and directly delivered to the imaging optical head. Preliminary testing of this imager on brain slices is presented, demonstrating a high signal-to-noise ratio and sub-cellular imaging capabilities to a depth of approximately 200 µm. These results demonstrate the suitability of the technology for
ex vivo and potentiallyin vivo cellular-level biomedical imaging applications. -
Fluorescence imaging techniques such as fluorescein angiography and fundus autofluorescence are often used to diagnose retinal pathologies; however, there are currently no standardized test methods for evaluating device performance. Here we present microstructured fluorescent phantoms fabricated using a submicron-scale three-dimensional printing technology, direct laser writing (DLW). We employ an
in situ DLW technique to print 10 µm diameter microfluidic channels that support perfusions of fluorescent dyes. We then demonstrate how broadband photoresist fluorescence can be exploited to generate resolution targets and biomimetic models of retinal vasculature using standard DLW processes. The results indicate that these approaches show significant promise for generating better performance evaluation tools for fluorescence microscopy and imaging devices. -
This Letter presents a novel, to the best of our knowledge, method to calibrate multi-focus microscopic structured-light three-dimensional (3D) imaging systems with an electrically adjustable camera focal length. We first leverage the conventional method to calibrate the system with a reference focal length
f 0. Then we calibrate the system with other discrete focal lengthsf i by determining virtual features on a reconstructed white plane usingf 0. Finally, we fit the polynomial function model using the discrete calibration results forf i . Experimental results demonstrate that our proposed method can calibrate the system consistently and accurately. -
Abstract Visualizing fluorescence‐tagged molecules is a powerful strategy that can reveal the complex dynamics of the cell. One robust and broadly applicable method is immunofluorescence microscopy, in which a fluorescence‐labeled antibody binds the molecule of interest and then the location of the antibody is determined by fluorescence microscopy. The effective application of this technique includes several considerations, such as the nature of the antigen, specificity of the antibody, permeabilization and fixation of the specimen, and fluorescence imaging of the cell. Although each protocol will require fine‐tuning depending on the cell type, antibody, and antigen, there are steps common to nearly all applications. This article provides protocols for staining the cytoskeleton and organelles in two very different kinds of cells: flat, adherent fibroblasts and thick, free‐swimming
Tetrahymena cells. Additional protocols enable visualization with widefield, laser scanning confocal, and eSRRF super‐resolution fluorescence microscopy. © 2023 Wiley Periodicals LLC.Basic Protocol 1 : Immunofluorescence staining of adherent cells such as fibroblastsBasic Protocol 2 : Immunofluorescence of suspension cells such asTetrahymena Basic Protocol 3 : Visualizing samples with a widefield fluorescence microscopeAlternate Protocol 1 : Staining suspension cells adhered to poly‐l ‐lysine‐coated coverslipsAlternate Protocol 2 : Visualizing samples with a laser scanning confocal microscopeAlternate Protocol 3 : Generating super‐resolution images with SRRF microscopy