skip to main content


Title: Underwater Depth Calibration Using a Commercial Depth Camera
Award ID(s):
1852403
NSF-PAR ID:
10404858
Author(s) / Creator(s):
; ; ; ; ; ;
Date Published:
Journal Name:
International Conference on Underwater Networks & Systems
Page Range / eLocation ID:
1 to 5
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Unsupervised monocular depth estimation techniques have demonstrated encour- aging results but typically assume that the scene is static. These techniques suffer when trained on dynamical scenes, where apparent object motion can equally be ex- plained by hypothesizing the object’s independent motion, or by altering its depth. This ambiguity causes depth estimators to predict erroneous depth for moving objects. To resolve this issue, we introduce Dynamo-Depth, an unifying approach that disambiguates dynamical motion by jointly learning monocular depth, 3D independent flow field, and motion segmentation from unlabeled monocular videos. Specifically, we offer our key insight that a good initial estimation of motion seg- mentation is sufficient for jointly learning depth and independent motion despite the fundamental underlying ambiguity. Our proposed method achieves state-of-the-art performance on monocular depth estimation on Waymo Open [34] and nuScenes [3] Dataset with significant improvement in the depth of moving objects. Code and additional results are available at https://dynamo-depth.github.io. 
    more » « less
  2. Single-photon lidar (SPL) is a promising technology for depth measurement at long range or from weak reflectors because of the sensitivity to extremely low light levels. However, constraints on the timing resolution of existing arrays of single-photon avalanche diode (SPAD) detectors limit the precision of resulting depth estimates. In this work, we describe an implementation of subtractively-dithered SPL that can recover high-resolution depth estimates despite the coarse resolution of the detector. Subtractively-dithered measurement is achieved by adding programmable delays into the photon timing circuitry that introduce relative time shifts between the illumination and detection that are shorter than the time bin duration. Careful modeling of the temporal instrument response function leads to an estimator that outperforms the sample mean and results in depth estimates with up to 13 times lower root mean-squared error than if dither were not used. The simple implementation and estimation suggest that globally dithered SPAD arrays could be used for high spatial- and temporal-resolution depth sensing.

     
    more » « less
  3. null (Ed.)