Title: A review of wireless power transfer using magnetoelectric structures
Abstract Wireless power transfer (WPT) has received increasing attention primarily as a means of recharging batteries in the last few decades. More recently, magnetoelectric (ME) structures have been investigated as alternative receiving antennas in WPT systems. ME structures can be particularly useful for small scale devices since their optimal size is much smaller than traditional receiving coils for a given operating frequency. WPT systems using ME laminate receivers have been shown to be helpful in wirelessly powering various sensors and biomedical implants. In recent years, a large number of studies have been conducted to improve the performance of ME composites, in which various configurations have been proposed, along with the use of different magnetostrictive and piezoelectric materials. In addition, many efforts have been devoted to miniaturizing ME devices. An essential obstacle to overcome is to eliminate the need for a DC bias field that is commonly required for the operation of ME structures. In this review paper, we will discuss the basic principle of ME effects in composites, materials currently in use, various ME receiver structures, performance measures, limitations, challenges, and future perspectives for the field of WPT. Furthermore, we propose a power figure of merit which we use to compare recent ME WPT research papers.  more » « less
Award ID(s):
1651438
PAR ID:
10408414
Author(s) / Creator(s):
; ;
Date Published:
Journal Name:
Smart Materials and Structures
Volume:
31
Issue:
11
ISSN:
0964-1726
Page Range / eLocation ID:
113001
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. To maximize the capabilities of minimally invasive implantable bioelectronic devices, we must deliver large amounts of power to small implants; however, as devices are made smaller, it becomes more difficult to transfer large amounts of power without a wired connection. Indeed, recent work has explored creative wireless power transfer (WPT) approaches to maximize power density [the amount of power transferred divided by receiver footprint area (length × width)]. Here, we analyzed a model for WPT using magnetoelectric (ME) materials that convert an alternating magnetic field into an alternating voltage. With this model, we identify the parameters that impact WPT efficiency and optimize the power density. We find that improvements in adhesion between the laminated ME layers, clamping, and selection of material thicknesses lead to a power density of 3.1 mW/mm2, which is over four times larger than previously reported for mm-sized wireless bioelectronic implants at a depth of 1 cm or more in tissue. This improved power density allows us to deliver 31 and 56 mW to 10 and 27-mm2 ME receivers, respectively. This total power delivery is over five times larger than similarly sized bioelectronic devices powered by radiofrequency electromagnetic waves, inductive coupling, ultrasound, light, capacitive coupling, or previously reported magnetoelectrics. This increased power density opens the door to more power-intensive bioelectronic applications that have previously been inaccessible using mm-sized battery-free devices. 
    more » « less
  2. This paper presents a method to wirelessly power sensors using magnetoelectric (ME) structures as receivers. ME receivers consist of composites of magnetostrictive (MS) and piezoelectric material. Using ME receivers, as opposed to inductively coupled coils, is useful when a combination of small size and low frequency are desirable. Most ME receivers require a large DC magnetic field bias for high-performance operation. We present magnetization grading approach with multiple layers of MS material that results in high-performance structures with no DC magnetic field bias required. Our device produces 600 microwatts when excited by a 100 microtesla AC magnetic field at 192.3 kHz. The device is 12.4 mm X 5 mm X 1 mm. The corresponding normalized power density is 10.71 mWcm−3Oe−2, which is the highest reported to our knowledge. 
    more » « less
  3. Composites of ferromagnetic and ferroelectric phases are of interest for studies on mechanical strain-mediated coupling between the two phases and for a variety of applications in sensors, energy harvesting, and high-frequency devices. Nanocomposites are of particular importance since their surface area-to-volume ratio, a key factor that determines the strength of magneto-electric (ME) coupling, is much higher than for bulk or thin-film composites. Core–shell nano- and microcomposites of the ferroic phases are the preferred structures, since they are free of any clamping due to substrates that are present in nanobilayers or nanopillars on a substrate. This review concerns recent efforts on ME coupling in coaxial fibers of spinel or hexagonal ferrites for the magnetic phase and PZT or barium titanate for the ferroelectric phase. Several recent studies on the synthesis and ME measurements of fibers with nickel ferrite, nickel zinc ferrite, or cobalt ferrite for the spinel ferrite and M-, Y-, and W-types for the hexagonal ferrites were considered. Fibers synthesized by electrospinning were found to be free of impurity phases and had uniform core and shell structures. Piezo force microscopy (PFM) and scanning microwave microscopy (SMM) measurements of strengths of direct and converse ME effects on individual fibers showed evidence for strong coupling. Results of low-frequency ME voltage coefficient and magneto-dielectric effects on 2D and 3D films of the fibers assembled in a magnetic field, however, were indicative of ME couplings that were weaker than in bulk or thick-film composites. A strong ME interaction was only evident from data on magnetic field-induced variations in the remnant ferroelectric polarization in the discs of the fibers. Follow-up efforts aimed at further enhancement in the strengths of ME coupling in core–shell composites are also discussed in this review. 
    more » « less
  4. null (Ed.)
    Wireless power transfer (WPT) has been widely used in IoT applications, such as mobile device charging, biomedical implants communication, and RFID field. Maximizing the power transfer efficiency (PTE) becomes one of the most crucial problems for designing the WPT systems. Magnetic induction (MI) beamforming has been proposed recently to maximize the PTE for the near field MIMO WPT systems. However, conventional magnetic beamforming in WPT systems usually requires accurate magnetic channel estimation, both amplitude and phase control of the charging source, which can not be achieved in an extreme environment. In this paper, we propose a novel magnetic induction beamforming scheme in MIMO WPT system using a reconfigurable metasurface. Instead of controlling the source currents or voltages, the reconfigurable metasurface can achieve near field beamforming only by varying the capacitor and resistance in specific coil array units. The beamforming is modeled as a discrete optimization problem and solved by using the Simulate Anneal (SA) method. Through the analytical and COMSOL simulation results, our proposed beamforming scheme can achieve approximately two times PTE of the conventional beamforming method in a 40 cm charging distance. 
    more » « less
  5. Bioelectronic devices and components made from soft, polymer-based and hybrid electronic materials form natural interfaces with the human body. Advances in the molecular design of stretchable dielectric, conducting and semiconducting polymers, as well as their composites with various metallic and inorganic nanoscale or microscale materials, have led to more unobtrusive and conformal interfaces with tissues and organs. Nonetheless, technical challenges associated with functional performance, stability and reliability of integrated soft bioelectronic systems still remain. This Review discusses recent progress in biomedical applications of soft organic and hybrid electronic materials, device components and integrated systems for addressing these challenges. We first discuss strategies for achieving soft and stretchable devices, highlighting molecular and materials design concepts for incorporating intrinsically stretchable functional materials. We next describe design strategies and considerations on wearable devices for on-skin sensing and prostheses. Moving beneath the skin, we discuss advances in implantable devices enabled by materials and integrated devices with tissue-like mechanical properties. Finally, we summarize strategies used to build standalone integrated systems and whole-body networks to integrate wearable and implantable bioelectronic devices with other essential components, including wireless communication units, power sources, interconnects and encapsulation. 
    more » « less