skip to main content

Attention:

The NSF Public Access Repository (NSF-PAR) system and access will be unavailable from 5:00 PM ET until 11:00 PM ET on Friday, June 21 due to maintenance. We apologize for the inconvenience.


Title: Design and fabrication of a novel on-chip pressure sensor for microchannels
Pressure is important in virtually all problems in fluid dynamics from macro-scale to micro/nano-scale flows. Although technologies are well developed for its measurement at the macroscopic scale, pressure quantification at the microscopic scale is still not trivial. This study reports the design and fabrication of an on-chip sensor that enables quantification of pressure in microfluidic devices based on a novel technique called astigmatic particle tracking. With this technique, thin membranes that sense pressure variations in the fluid flow can be characterized conveniently by imaging the shapes of the particles embedded in the membranes. This innovative design only relies on the reflected light from the back of the microchannel, rendering the sensor to be separate and noninvasive to the flow of interest. This sensor was then applied to characterize the pressure drop in single-phase flows with an accuracy of ∼70 Pa and good agreement was achieved between the sensor, a commercial pressure transducer and numerical simulation results. Additionally, the sensor successfully measured the capillary pressure across an air–water interface with a 7% deviation from the theoretical value. To the best of our knowledge, this pore-scale capillary pressure quantification is achieved for the first time using an on-chip pressure sensor of this kind. This study provides a novel method for in situ quantification of local pressure and thus opens the door to a renewed understanding of pore-scale physics of local pressure in multi-phase flow in porous media.  more » « less
Award ID(s):
2144802
NSF-PAR ID:
10409458
Author(s) / Creator(s):
; ; ; ;
Date Published:
Journal Name:
Lab on a Chip
Volume:
22
Issue:
22
ISSN:
1473-0197
Page Range / eLocation ID:
4306 to 4316
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. The accurate measurement of wall zeta potentials and solute–surface interaction length scales for electrolyte and non-electrolyte solutes, respectively, is critical to the design of many biomedical and microfluidic applications. We present a novel microfluidic approach using diffusioosmosis for measuring either the zeta potentials or the characteristic interaction length scales for surfaces exposed to, respectively, electrolyte or non-electrolyte solutes. When flows containing different solute concentrations merge in a junction, local solute concentration gradients can drive diffusioosmotic flow due to electrokinetic, steric, and other interactions between the solute molecules and solid surfaces. We demonstrate a microfluidic system consisting of a long, narrow pore connecting two large side channels in which solute concentration gradients drive diffusioosmosis within the pore, resulting in predictable fluid velocity/pressure and solute profiles. Furthermore, we present analytical results and a methodology to determine the zeta potential or interaction length scale for the pore surfaces based on the solute concentrations in the main side channels, the flow rate in the pore, and the pressure drop across the pore. We apply this method to the experimental data of Lee et al. to predict the zeta potentials of their system, and we use 3D numerical simulations to validate the theory and show that end effects caused by the junctions are negligible for a wide range of parameters. Because the dynamics in the proposed system are driven by diffusioosmosis, this technique does not suffer from certain disadvantages associated with the use of sensitive electronics in traditional zeta potential measurement approaches such as streaming potential, streaming current, or electroosmosis. To the best of our knowledge this is the first flow-based approach to characterize surface/solute interactions with non-electrolyte solutes. 
    more » « less
  2. Abstract

    Dynamic pore‐network model (PNM) has been widely used to model pore‐scale two‐phase flow. Numerical algorithms commonly used for dynamic PNM including IMPES (implicit pressure explicit saturation) and IMP‐SIMS (implicit pressure semi‐implicit saturation) can be numerically unstable or inaccurate for challenging flow regimes such as low capillary number (Ca) flow and unfavorable displacements. We perform comprehensive analyses of IMPES and IMP‐SIMS for a wide range of flow regimes under drainage conditions and develop a novel fully implicit (FI) algorithm to address their limitations. Our simulations show the following: (1) While IMPES was reported to be numerically unstable for lowCaflow, using a smoothed local pore‐body capillary pressure curve appears to produce stable simulations. (2) Due to an approximation for the capillary driving force, IMP‐SIMS can deviate from quasi‐static solutions at equilibrium states especially in heterogeneous networks. (3) Both IMPES and IMP‐SIMS introduce mass conservation errors. The errors are small for networks with cubic pore bodies (less than 1.4% for IMPES and 1.2% for IMP‐SIMS). They become much greater for networks with square‐tube pore bodies (up to 45% for IMPES and 46% for IMP‐SIMS). Conversely, the new FI algorithm is numerically stable and mass conservative regardless of the flow regimes and pore geometries. It also precisely recovers the quasi‐static solutions at equilibrium states. The FI framework has been extended to include compressible two‐phase flow, multicomponent transport, and phase change dynamics. Example simulations of two‐phase displacements accounting for phase change show that evaporation and condensation can suppress fingering patterns generated during invasion.

     
    more » « less
  3. We present a multi-scale mathematical model and a novel numerical solver to study blood plasma flow and oxygen concentration in a prototype model of an implantable Bioartificial Pancreas (iBAP) that operates under arteriovenous pressure differential without the need for immunosuppressive therapy. The iBAP design consists of a poroelastic cell scaffold containing the healthy transplanted cells, encapsulated between two semi-permeable nano-pore size membranes to prevent the patient’s own immune cells from attacking the transplant. The device is connected to the patient’s vascular system via an anastomosis graft bringing oxygen and nutrients to the transplanted cells of which oxygen is the limiting factor for long-term viability. Mathematically, we propose a (nolinear) fluid–poroelastic structure interaction model to describe the flow of blood plasma through the scaffold containing the cells, and a set of (nonlinear) advection–reaction–diffusion equations defined on moving domains to study oxygen supply to the cells. These macro-scale models are solved using finite element method based solvers. One of the novelties of this work is the design of a novel second-order accurate fluid–poroelastic structure interaction solver, for which we prove that it is unconditionally stable. At the micro/nano-scale, Smoothed Particle Hydrodynamics (SPH) simulations are used to capture the micro/nano-structure (architecture) of cell scaffolds and obtain macro-scale parameters, such as hydraulic conductivity/permeability, from the micro-scale scaffold-specific architecture. To avoid expensive micro-scale simulations based on SPH simulations for every new scaffold architecture, we use Encoder–Decoder Convolution Neural Networks. Based on our numerical simulations, we propose improvements in the current prototype design. For example, we show that highly elastic scaffolds have a higher capacity for oxygen transfer, which is an important finding considering that scaffold elasticity can be controlled during their fabrication, and that elastic scaffolds improve cell viability. The mathematical and computational approaches developed in this work provide a benchmark tool for computational analysis of not only iBAP, but also, more generally, of cell encapsulation strategies used in the design of devices for cell therapy and bio-artificial organs. 
    more » « less
  4. Pumping is an essential component in many microfluidic applications. Developing simple, small-footprint, and flexible pumping methods is of great importance to achieve truly lab-on-a-chip systems. Here, we report a novel acoustic pump based on the atomization effect induced by a vibrating sharp-tip capillary. As the liquid is atomized by the vibrating capillary, negative pressure is generated to drive the movement of fluid without the need to fabricate special microstructures or use special channel materials. We studied the influence of the frequency, input power, internal diameter (ID) of the capillary tip, and liquid viscosity on the pumping flow rate. By adjusting the ID of the capillary from 30 µm to 80 µm and the power input from 1 Vpp to 5 Vpp, a flow rate range of 3 to 520 µL/min can be achieved. We also demonstrated the simultaneous operation of two pumps to generate parallel flow with a tunable flow rate ratio. Finally, the capability of performing complex pumping sequences was demonstrated by performing a bead-based ELISA in a 3D-printed microdevice.

     
    more » « less
  5. Abstract

    Three‐dimensional (3D) X‐ray computed tomography (X‐ray CT) imaging has emerged as a nondestructive means of microstructural characterization. However, obtaining and processing high‐quality and high‐resolution images is time‐consuming and often requires high‐performance computing, particularly with a high number of projections. This work evaluates the effect of 3D X‐ray CT imaging parameters on pore connectivity and surface area quantification in sandstone samples of varied composition. Samples from Bentheimer and Torrey Buff formations are imaged via 3D X‐ray CT imaging at resolutions ranging from 1.25 to 15 μm, bin sizes 1, 2, and 4, and number of projections from 400 to 4,500. Collected images are processed and analyzed using ImageJ and MATLAB to discern petrophysical properties and the results are compared with each other and Mercury Intrusion Capillary Pressure (MICP) results. Overall, little variation in bulk porosity with changing scanning parameters is observed. However, for low resolution and projection numbers, connected porosity is lower compared to bulk porosity due to a failure to capture microfeatures. Overall, mineral surface area is observed to decrease with increasing bin size, voxel size, and projection numbers, except an observed increase with projection numbers for Torrey Buff. The Torrey Buff samples contains comparatively more clays and even the highest resolution (1.25 μm) fails to separate the micrograins, which is reflected in the pore size distribution. Identifying these variations are helpful as discrepancies in imaged pore connectivity and surface area can largely impact assessments of fluid flow and transport in reactive transport simulations informed by this data.

     
    more » « less