Title: Four-color fluorescence cross-correlation spectroscopy with one laser and one camera

The diffusion and reorganization of phospholipids and membrane-associated proteins are fundamental for cellular function. Fluorescence cross-correlation spectroscopy (FCCS) measures diffusion and molecular interactions at nanomolar concentration in biological systems. We have developed an economical method to simultaneously monitor diffusion and complexation with the use of super-continuum laser and spectral deconvolution from a single detector. Customizable excitation wavelengths were chosen from the wide-band source and spectral fitting of the emitted light revealed the interactions for up to four chromatically overlapping fluorophores simultaneously. This method was applied to perform four-color FCCS that we demonstrated with polystyrene nanoparticles, lipid vesicles, and membrane-bound molecules. Up to four individually customizable excitation channels were selected from the broad-spectrum fiber laser to excite the diffusers within a diffraction-limited spot. The fluorescence emission passed through a cleanup filter and a dispersive prism prior to being collected by a sCMOS or EMCCD camera with up to 1.8 kHz frame rates. The emission intensity versus time of each fluorophore was extracted through a linear least-square fitting of each camera frame and temporally correlated via custom software. Auto- and cross-correlation functions enabled the measurement of the diffusion rates and binding partners. We have measured the induced aggregation of nanobeads and lipid vesicles in solution upon increasing the buffer salinity. Because of the adaptability of investigating four fluorophores simultaneously with a cost-effective method, this technique will have wide application for examining macromolecular complex formation in model and living systems.

 
more » « less
Award ID(s):
1652316
NSF-PAR ID:
10427467
Author(s) / Creator(s):
; ; ;
Publisher / Repository:
Optical Society of America
Date Published:
Journal Name:
Biomedical Optics Express
Volume:
14
Issue:
7
ISSN:
2156-7085
Page Range / eLocation ID:
Article No. 3812
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Electrostatic interactions drive molecular assembly and organization in the plasma membrane. Specific protein-lipid interactions, however, are difficult to resolve. Here we report on a unique approach to investigate these interactions with time-resolved fluorescence spectroscopy. The experiments were performed on a model membrane system consisting of a supported lipid bilayer with an asymmetric distribution of PIP2 in the upper leaflet of the bilayer. The bilayer also contained nickel-chelating lipids that bind to a histidine-tagged peptide of interest. Both the peptide and the lipid were labeled with orthogonal fluorescent probes, so that diffusion and binding could be measured with two-color, pulsed-interleaved excitation fluorescence cross-correlation spectroscopy (PIE-FCCS). Our PIE-FCCS data showed significant lipid-peptide cross-correlation between PIP2 lipids and membrane-bound cationic peptides. Cross-correlation is a direct indication of lipid-peptide binding and complexation. Together with mobility data, we quantified the degree of binding, which offers new insight into this class of lipid-peptide interactions. Overall, this is the first report of lipid-peptide cross-correlation by FCCS, and provides a new route to quantifying the interactions between proteins and lipid membranes, a key interface in cell signaling. 
    more » « less
  2. We built a simple and versatile setup to measure tissue ballistic and total transmission with customizable wavelength range, spatial resolution, and sample sizes. We performed ballistic transmission and total transmission measurements of overlying structures from biological samplesex vivo. We obtained spatially resolved transmission maps to reveal transmission heterogeneity from five microscale tissue samples:Danionellaskin, mouse skull bone, mosquito cuticle, wasp cuticle, and rat dura over a wide spectral range from 450 nm to 1624 nm at a spatial resolution of ∼25µm for ballistic transmission measurements and ∼50µm for total transmission measurements. We expect our method can be straightforwardly applied to measuring the transmission of other samples. The measurement results will be valuable for multiphoton microscopy. The total transmission of a sample is important for the collection of multiphoton excited fluorescence and the assessment of laser-induced sample heating. The ballistic transmission determines the excitation power at the focus and hence the fluorescence signal generation. Therefore, knowledge of ballistic transmission, total transmission, and transmission heterogeneity of overlying structures of animals and organs are essential to determine the optimal excitation wavelength and fluorophores for non-invasive multiphoton microscopy.

     
    more » « less
  3. Förster resonance energy transfer (FRET) is a valuable tool for measuring molecular distances and the effects of biological processes such as cyclic nucleotide messenger signaling and protein localization. Most FRET techniques require two fluorescent proteins with overlapping excitation/emission spectral pairing to maximize detection sensitivity and FRET efficiency. FRET microscopy often utilizes differing peak intensities of the selected fluorophores measured through different optical filter sets to estimate the FRET index or efficiency. Microscopy platforms used to make these measurements include wide-field, laser scanning confocal, and fluorescence lifetime imaging. Each platform has associated advantages and disadvantages, such as speed, sensitivity, specificity, out-of-focus fluorescence, and Zresolution. In this study, we report comparisons among multiple microscopy and spectral filtering platforms such as standard 2-filter FRET, emission-scanning hyperspectral imaging, and excitation-scanning hyperspectral imaging. Samples of human embryonic kidney (HEK293) cells were grown on laminin-coated 28 mm round gridded glass coverslips (10816, Ibidi, Fitchburg, Wisconsin) and transfected with adenovirus encoding a cAMP-sensing FRET probe composed of a FRET donor (Turquoise) and acceptor (Venus). Additionally, 3 FRET “controls” with fixed linker lengths between Turquoise and Venus proteins were used for inter-platform validation. Grid locations were logged, recorded with light micrographs, and used to ensure that whole-cell FRET was compared on a cell-by-cell basis among the different microscopy platforms. FRET efficiencies were also calculated and compared for each method. Preliminary results indicate that hyperspectral methods increase the signal-to-noise ratio compared to a standard 2-filter approach. 
    more » « less
  4. Abstract Background

    Commonly used methods to measure whole gut transit time in rodents have yet to combine high sensitivity, objectivity, and automation. We have developed a novel method using oral gavage of non‐toxic fluorescent dye particles and their detection by fluorescence imaging to enable unbiased automated detection of gut transit time simultaneously in 8 cages.

    Methods

    Naïve mice (n = 20) were gavaged with a non‐caloric viscous suspension of 4.4% fluorescent dye in 3 groups on 2 occasions. Each group was imaged in 8 cages at 5‐minute intervals using blue LEDs for illumination and a Sony full‐frame mirrorless camera with a green band‐pass emission filter. Custom MATLAB code counted the number of fluorescent boli per cage post hoc and provided graphical and spreadsheet output. Boli counts across a wide range of parameters were compared to blind assessments by an experimenter.

    Results

    Fluorescent boli were detected with high sensitivity, while unstained boli were readily rejected. All cages showed no fluorescent boli for the first ~20 frames (100 minutes), after which many cages gradually show a rise to 1‐6 fluorescent boli. The mean time to first fluorescent bolus in each session was 264 ± 141 and 223 ± 81 minutes post‐gavage, with no within subject consistency. There was high correlation between automated scores and that of experimenter (r = .95 ± .02), being robust to parameter changes.

    Conclusions and Inferences

    This novel approach provides a reliable, automatic, and low‐cost method of measuring gastrointestinal transit time in mice.

     
    more » « less
  5. In this study, we used optical spectroscopy to characterize the physical properties of microvesicles released from the thermoacidophilic archaeon Sulfolobus acidocaldarius (Sa-MVs). The most abundant proteins in Sa-MVs are the S-layer proteins, which self-assemble on the vesicle surface forming an array of crystalline structures. Lipids in Sa-MVs are exclusively bipolar tetraethers. We found that when excited at 275 nm, intrinsic protein fluorescence of Sa-MVs at 23 °C has an emission maximum at 303 nm (or 296 nm measured at 75 °C), which is unusually low for protein samples containing multiple tryptophans and tyrosines. In the presence of 10–11 mM of the surfactant n-tetradecyl-β-d-maltoside (TDM), Sa-MVs were disintegrated, the emission maximum of intrinsic protein fluorescence was shifted to 312 nm, and the excitation maximum was changed from 288 nm to 280.5 nm, in conjunction with a significant decrease (>2 times) in excitation band sharpness. These data suggest that most of the fluorescent amino acid residues in native Sa-MVs are in a tightly packed protein matrix and that the S-layer proteins may form J-aggregates. The membranes in Sa-MVs, as well as those of unilamellar vesicles (LUVs) made of the polar lipid fraction E (PLFE) tetraether lipids isolated from S. acidocaldarius (LUVPLFE), LUVs reconstituted from the tetraether lipids extracted from Sa-MVs (LUVMV) and LUVs made of the diester lipids, were investigated using the probe 6-dodecanoyl-2-dimethylaminonaphthalene (Laurdan). The generalized polarization (GP) values of Laurdan in tightly packed Sa-MVs, LUVMV, and LUVPLFE were found to be much lower than those obtained from less tightly packed DPPC gel state, which echoes the previous finding that the GP values from tetraether lipid membranes cannot be directly compared with the GP values from diester lipid membranes, due to differences in probe disposition. Laurdan’s GP and red-edge excitation shift (REES) values in Sa-MVs and LUVMV decrease with increasing temperature monotonically with no sign for lipid phase transition. Laurdan’s REES values are high (9.3–18.9 nm) in the tetraether lipid membrane systems (i.e., Sa-MVs, LUVMV and LUVPLFE) and low (0.4–5.0 nm) in diester liposomes. The high REES and low GP values suggest that Laurdan in tetraether lipid membranes, especially in the membrane of Sa-MVs, is in a very motionally restricted environment, bound water molecules and the polar moieties in the tetraether lipid headgroups strongly interact with Laurdan’s excited state dipole moment, and “solvent” reorientation around Laurdan’s chromophore in tetraether lipid membranes occurs very slowly compared to Laurdan’s lifetime. 
    more » « less