<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Nanoporous Atomically Thin Graphene Filters for Nanoscale Aerosols</title></titleStmt>
			<publicationStmt>
				<publisher></publisher>
				<date>09/14/2022</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10429594</idno>
					<idno type="doi">10.1021/acsami.2c10827</idno>
					<title level='j'>ACS Applied Materials &amp; Interfaces</title>
<idno>1944-8244</idno>
<biblScope unit="volume">14</biblScope>
<biblScope unit="issue">36</biblScope>					

					<author>Peifu Cheng</author><author>Jeremy Espano</author><author>Andrew Harkaway</author><author>Andrew E. Naclerio</author><author>Nicole K. Moehring</author><author>Philipp Braeuninger-Weimer</author><author>Piran R. Kidambi</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[Filtering nanoparticulate aerosols from air streams is important for a wide range of personal protection equipment (PPE), including masks used for medical research, healthcare, law enforcement, first responders, and military applications. Conventional PPEs capable of filtering nanoparticles <300 nm are typically bulky and sacrifice breathability to maximize protection from exposure to harmful nanoparticulate aerosols including viruses ∼20-300 nm from air streams. Here, we show that nanopores introduced into centimeter-scale monolayer graphene supported on polycarbonate track-etched supports via a facile oxygen plasma etch can allow for filtration of aerosolized SiO 2 nanoparticles of ∼5-20 nm from air steams while maintaining air permeance of ∼2.28-7.1 × 10 -5 mol m -2 s -1 Pa -1 . Furthermore, a systematic increase in oxygen plasma etch time allows for a tunable size-selective filtration of aerosolized nanoparticles. We demonstrate a new route to realize ultra-compact, lightweight, and conformal form-factor filters capable of blocking sub-20 nm aerosolized nanoparticles with particular relevance for biological/viral threat mitigation.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head>&#9632; INTRODUCTION</head><p>Airborne nanoparticles <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[4]</ref><ref type="bibr">[5]</ref><ref type="bibr">[6]</ref><ref type="bibr">[7]</ref><ref type="bibr">[8]</ref><ref type="bibr">[9]</ref> include pollutants, toxins, engineered nanoparticles, and infectious/harmful viruses (&#8764;20-300 nm in diameter), such as the influenza virus, rhinovirus, and coronavirus, among others. <ref type="bibr">[10]</ref><ref type="bibr">[11]</ref><ref type="bibr">[12]</ref><ref type="bibr">[13]</ref> Most conventional air filters, <ref type="bibr">[14]</ref><ref type="bibr">[15]</ref><ref type="bibr">[16]</ref> for example, the high-efficiency particulate air filter (HEPA) and the non-oil 95% efficiency filter (N95) have excellent air flow rates (&#8764;1.08 &#215; 10 -3 to 4.40 &#215; 10 -2 mol m -2 s -1 Pa -1 ) <ref type="bibr">14,</ref><ref type="bibr">15</ref> but struggle to filter nanoparticles &lt;300 nm. State-of-the-art personal protective equipment (PPE), for example, masks capable of filtering nanoparticles &lt;300 nm and specifically in the lower size ranges (&lt;100 nm) remain bulky and cumbersome to use and, in most cases, create thermal stress due to poor breathability; <ref type="bibr">17</ref> that is, they do not allow for sweat-based cooling via rapid water vapor transport. <ref type="bibr">18</ref> However, PPEs with efficient evaporative cooling of the human body through perspiration are highly desired in protective applications for medical research, healthcare, law enforcement, first responders, and military applications. <ref type="bibr">17</ref> Approaches to develop improved PPEs have mostly focused on making porous polymers with high thicknesses where nanoparticulate pollutants, toxins, or pathogens are removed by depth filtration. <ref type="bibr">17,</ref><ref type="bibr">18</ref> However, these approaches do not guarantee protection since longer exposure will inevitably lead to a break-through and the breathability for such thick polymer layers is typically very low. <ref type="bibr">17</ref> Some progress has indeed been made in increasing breathability of conventional polymeric materials; for example, (i) by introducing porosity in butyl rubber-based materials <ref type="bibr">19</ref> and developing reactive organic/ inorganic composite film materials that actively degrade harmful agents on contact, <ref type="bibr">20</ref> (ii) including non-woven materials, <ref type="bibr">21</ref> (iii) fabricating hollow fiber membrane by spinning polymers (air permeance of &#8764;1.6 &#215; 10 -5 mol m -2 s -1 Pa -1 , filtration size 100 nm), <ref type="bibr">22</ref> (iv) incorporating Li + ions in thermoplastic polyurethane nanofiber/net (TPU-NF) membrane-based air filters (air permeance of &#8764;3.7 &#215; 10 -2 mol m -2 s -1 Pa -1 , filtration size 100 nm, PM 0.1 ), <ref type="bibr">23</ref> and (v) integrating microfiber layers of polysulfone (PSU), polyacrylonitrile (PAN) nanofiber layer, and polyamide-6 (PA-6) nets to build the PSU/PAN/PA-6 air filter (air permeance of &#8764;1.2 &#215; 10 -2 mol m -2 s -1 Pa -1 , filtration size &#8764;300 nm NaCl aerosol particles). <ref type="bibr">24</ref> Finally, etching nanoscale tracks in polymers have also been explored; for example, polycarbonate track-etch (PCTE) membranes with different pore sizes &#8764;10-200 nm show air permeance from &#8764;7.4 &#215; 10 -7 to 3 &#215; 10 -4 mol m -2 s -1 Pa -1 . <ref type="bibr">25</ref> In this context, membranes incorporating nanomaterials such as vertically aligned carbon nanotubes (CNTs) with &lt;5 nm diameter have shown nitrogen permeance of 1.81 &#177; 0.36 &#215; 10 -5 mol m -2 s -1 Pa -1 , as well as the ability to block 3 nm charged dyes, 5 nm uncharged gold (Au) nanoparticles, and &#8764;40-60 nm dengue virus from aqueous solutions. <ref type="bibr">26</ref> Vertically aligned CNT membranes with &lt;2 nm pores have also shown air permeance &#8764;1.9 &#215; 10 -5 mol m -2 s -1 Pa -1 attributed to slip length and the atomically smooth CNT surfaces. <ref type="bibr">27</ref> However, tuning CNT diameters to target specific applications requiring filtration of aerosolized nanoparticles of a particular size and scaling-up for large-area manufacturing remains challenging. <ref type="bibr">[18]</ref><ref type="bibr">[19]</ref><ref type="bibr">[20]</ref><ref type="bibr">[21]</ref><ref type="bibr">26</ref> More recently, theoretical calculations have suggested porous silicon membranes for protection against corona viruses. <ref type="bibr">28</ref> Finally, zeolite membranes have also shown high permeance; for example, the decadodesil 3R (DD3R) membrane has air permeance of &#8764;2.2 &#215; 10 -9 mol m -2 s -1 Pa -1 with pores &#8764;0.36 &#215; 0.44 nm, <ref type="bibr">29</ref> while the silicoaluminophosphate-34 (SAPO-34) membrane shows air permeance of &#8764;5.4 &#215; 10 -8 mol m -2 s -1 Pa -1 with a pore size of &#8764;0.38 nm but has not been tested for aerosol filtration. <ref type="bibr">30</ref> Graphene with atomic thinness, high mechanical strength, 31 chemical robustness, and high-density nanopores presents a new class of materials for size-selective separation. <ref type="bibr">32,</ref><ref type="bibr">33</ref> Here, we demonstrate a novel approach to develop nanoporous atomically thin graphene membranes for filtering nanoscale aerosols &#8764;5-20 nm (SiO 2 nanoparticles) from air streams while maintaining up to &#8764;7.12 &#215; 10 -5 mol m -2 s -1 Pa -1 (&#8764;75% of the air flow of the bare substrate). The ultracompact, lightweight, and conformal form-factor filters offer transformative advances for PPE for medical research, healthcare, law enforcement, first responders, and military applications. To the best of our knowledge, this is one of the first demonstrations of an atomically thin membrane filtering aerosolized nanoparticles in the &#8764;5-20 nm size range.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>&#9632; RESULTS AND DISCUSSION</head><p>A schematic of our fabrication process and an optical image of the resulting centimeter-scale nanoporous graphene membrane are shown in Figure <ref type="figure">1A</ref>. Monolayer graphene synthesized via chemical vapor deposition (CVD) on copper foil <ref type="bibr">34,</ref><ref type="bibr">35</ref> is initially transferred onto PCTE supports with &#8764;200 nm pores, and any large tears are sealed by interfacial polymerization (IP) before introducing nanopores via an oxygen plasma etch (0-180 s) of the graphene lattice (see Experimental Section). <ref type="bibr">[34]</ref><ref type="bibr">[35]</ref><ref type="bibr">[36]</ref><ref type="bibr">[37]</ref><ref type="bibr">[38]</ref><ref type="bibr">[39]</ref><ref type="bibr">[40]</ref><ref type="bibr">[41]</ref><ref type="bibr">[42]</ref><ref type="bibr">[43]</ref> Scanning electron microscopy (SEM) image (Figure <ref type="figure">1B</ref>) of the as-synthesized CVD graphene on Cu foil shows wrinkles (originating from the differences in thermal expansions of graphene and copper), indicating a continuous layer. <ref type="bibr">35,</ref><ref type="bibr">44</ref> Raman spectroscopy (Figure <ref type="figure">1C</ref>) with the characteristic graphene peaks (2D &#8764;2700 cm -1 , G &#8764;1600 cm -1 ) and the absence of a D peak (&#8764;1350 cm -1 ) confirms the high quality of the synthesized monolayer (I 2D /I G &gt;1) graphene film. <ref type="bibr">45</ref> The SEM image of graphene on PCTE support (Figure <ref type="figure">1D</ref>) shows a majority of PCTE pores with &#8764;200 nm diameter covered with graphene (darker contrast in SEM), indicating successful transfer, along with some uncovered regions (brighter regions in SEM) due to tears in the graphene from the manual pressing step of the transfer. These uncovered regions in the PCTE appear brighter in the SEM due to polymer charging (Figure <ref type="figure">1D</ref>).</p><p>The well-defined cylindrical geometry of the PCTE support avoids interconnected pores and thereby (i) enables sealing of tears and other macroscopic damage/defects to graphene from transfer via IP and (ii) also allows for clear interpretation of transport results from the atomically thin graphene layer. 32 Specifically, the IP process <ref type="bibr">38,</ref><ref type="bibr">41,</ref><ref type="bibr">46,</ref><ref type="bibr">47</ref> used to seal tears and other damages/large defects from graphene transfer leverages (i) the immiscibility of hexane and water to form a sharp interface, (ii) the solubility of trimesoyl-chloride solution (TMC) in hexane and its instability (decomposition) in water, and (iii) the solubility of octa-ammonium-polyhedral-oligomeric-silsesquioxane (POSS) in water and its insolubility in hexane. Hence, the interface for the formation of IP plugs is pinned within the PCTE support pore (since TMC will dissociate in water, POSS will have to diffuse into the organic phase to react with TMC and form a plug), thereby allowing the graphene surface to remain clean. <ref type="bibr">46,</ref><ref type="bibr">48,</ref><ref type="bibr">49</ref> Post IP, nanopores are introduced via the facile plasma etch of the graphene lattice (see Experimental Section) before testing the membranes. <ref type="bibr">50,</ref><ref type="bibr">51</ref> The Raman spectrum of graphene subjected to oxygen plasma (60 s) confirms the formation of defects (see the large D peak in Figure <ref type="figure">1C</ref>). <ref type="bibr">38,</ref><ref type="bibr">45</ref> Initially, we characterized the nanopores introduced into the graphene membranes by measuring diffusion-driven flow of ions and molecules, representing sizes from &#8764;0.66 to 4 nm (Figure <ref type="figure">2A</ref>), that is, KCl (hydrated K + and Cl -ions &#8764;0.66 nm), L-tryptophan (L-Tr, &#8764;0.7-0.9 nm), vitamin B12 (B12, &#8764;1-1.5 nm), and lysozyme (Lz, &#8764;3.8-4.0 nm) using a sideby-side diffusion cell (Figure <ref type="figure">2B</ref>). <ref type="bibr">32,</ref><ref type="bibr">38</ref> Representative diffusiondriven flow measurements through graphene membranes subjected to 60 s of oxygen plasma time (PCTE + G + IP + 60s O 2 plasma) show a flux of KCl &gt; L-Tr &gt; B12 &gt; Lz. The normalized diffusive flux with respect to a bare PCTE membrane (Figure <ref type="figure">2C</ref>) for KCl &#8764;79.5%, L-Tr &#8764;68.8%, B12 &#8764;31.6%, and Lz &#8764;16.3% indicates the majority of the nanopores introduced into the graphene lattice are &lt;4 nm (for 60 s of oxygen plasma), consistent with prior observations in the literature. <ref type="bibr">38</ref> These observations indicate that nanopores in our atomically thin graphene membranes allow for the sizeselective transport of smaller ions and molecules such as KCl, L-Tr, and B12 while hindering the transport of larger macromolecules such as Lz &#8764;3.8-4 nm. <ref type="bibr">32,</ref><ref type="bibr">38,</ref><ref type="bibr">52</ref> Diffusiondriven flow measurements for molecules &gt;4 nm in diameter are non-trivial, wherein the slow diffusion of the larger molecules can influence measurements.</p><p>Next, we mounted the graphene membranes into our custom-built setup (Figures <ref type="figure">3C</ref> and<ref type="figure">S1</ref>) to evaluate the performance of the graphene membranes for filtering aerosolized nanoparticles with SiO 2 as a model system. We note that Boutilier et al. used a similar setup to measure gas flow through nanoporous atomically thin membranes. <ref type="bibr">53</ref> A perforated steel plate was used to provide mechanical stability to the membranes over centimeter-scale areas experiencing differential pressure, and an aluminum masking tape with a 5 mm hole and epoxy on the edges was used to define the area of measurement (Figure <ref type="figure">3A,</ref><ref type="figure">B</ref>) as well as prevent leakages.</p><p>The rate of pressure change in the evacuated reservoirs in the setup was used to measure the air flow through graphene membranes (Figure <ref type="figure">3D</ref>). The large reservoir, system base pressure &#8764;2-3 Torr with a roughing pump, and the high accuracy of the pressure transducer allowed for a linear relationship between pressure change and time even for the maximum flows measured in our experimental design, that is, bare steel supports (&#8764;2800 mTorr/s, Figures <ref type="figure">S2-S4</ref>). We also minimized variations in the base pressure at the start of the experiments (&#8764;2-3 Torr) to mitigate any influence on the measurements (Figures <ref type="figure">S3</ref> and<ref type="figure">S4</ref>). The upper bound of air flow that can be achieved with our graphene membrane in this study is the air flow corresponding to the rate of change in pressure through a bare PCTE (&#8764;10% porosity) support without graphene &#8764;13.47 mTorr/s. We emphasize that increasing support porosity and support pore diameter as well as reducing support thickness will allow for much higher air permeances and can be pursued for practical applications in future developments.</p><p>Bare PCTE membranes subjected to IP showed a rate of change in pressure &#8764;0.60 mTorr/s, which indicates a lower bound on air flow through the membranes and indicates baseline leakage through IP plugs. Interestingly, graphene transferred to PCTE and treated with IP (PCTE + G + IP) showed a rate of change in pressure of &#8764;1.10 mTorr/s (Figure <ref type="figure">3D</ref>). These observations indicate that graphene can withstand the pressure difference between the evacuated chamber &#8764;2.50 Torr and ambient pressure <ref type="bibr">54</ref> in agreement with literature reports, wherein single layer graphene supported on PCTE supports was shown to withstand pressure differences of up to 100 bar. <ref type="bibr">31</ref> The rate of pressure change for PCTE + G + IP &#8764;1.10 mTorr/s is comparable to the baseline leakage rate of 0.40 mTorr/s (see Figure <ref type="figure">S2</ref>) indicating that the PCTE + G + IP membrane without nanopore creation allows for negligible air flow. Hence, we introduced nanopores via facile oxygen plasma etch and observed an increase in the rate of change in pressure values to &#8764;3.50 and &#8764;8.78 mTorr/s for 60 and 90 s of etch times, respectively. Extending the oxygen plasma time further increases the rate of pressure change until a value of &#8764;13.11 mTorr/s is reached for 180 s of etch time, that is, similar to the PCTE support value of &#8764;13.47 mTorr/s, indicating extensive structural damage to the graphene lattice in agreement with prior studies using oxygen plasma to etch graphene. <ref type="bibr">38,</ref><ref type="bibr">53</ref> The variability between membranes (e.g., PCTE + G + IP + 120 s O 2 plasma and PCTE + G + IP + 150 s O 2 plasma) stems from different graphene transfer yields, IP processes, and epoxy sealing.</p><p>Having measured the rate of change of pressure as a function of oxygen plasma etch time on our graphene membranes, we proceeded to evaluate their ability to filter aerosolized nanoparticles using SiO 2 as a model system in air streams. We selected silica aerosols because the silica particles are rigid spheres with a very narrow size distribution, for example, 5 nm silica (&#8764;4-6 nm), 8 nm silica (&#8764;7-10 nm), 12 nm silica (&#8764;10-14 nm), and 20 nm silica (&#8764;20 nm) and are inexpensive. The extremely narrow particle size distribution and rigid sphere geometry make them ideal model systems for probing defect sizes in our graphene membranes. The SiO 2 nanoparticles of a specific size (5, 8, 12, or 20 nm) were aerosolized from 0.6 mL (15 to 40 wt % in H 2 O) of colloidal dispersions and allowed to mix with the air stream that passes through our graphene membranes (Figures <ref type="figure">3C</ref> and<ref type="figure">S1</ref>). We compared the rate of change of pressure for the membranes before and after they were exposed to the aerosolized SiO 2 nanoparticles in the air stream (Figure <ref type="figure">3E,</ref><ref type="figure">F</ref>). Any decrease in flow rate for the same membrane after exposure to the aerosolized nanoparticles indicates filtering of the nanoparticles via plugging of the etched nanopores (Figure <ref type="figure">3E,</ref><ref type="figure">F</ref>). <ref type="bibr">55,</ref><ref type="bibr">56</ref> The concentration of SiO 2 nanoparticles was deliberately kept low enough to rule out the formation of a nanoparticulate filter cake/coating on our graphene membranes (see Figure <ref type="figure">S7</ref>). Furthermore, we emphasize that the formation of a filter cake will reduce the rate of change of pressure for all graphene membranes, irrespective of the size of particles being tested, and such an effect was not seen in our experiments (see Figure <ref type="figure">3</ref> and Figure <ref type="figure">S7</ref>).</p><p>For the unetched graphene membrane (PCTE + G + IP + 0 s O 2 plasma etch), the rate of change of pressure remains the same before and after testing with 5 nm SiO 2 nanoparticles (Figure <ref type="figure">3E,</ref><ref type="figure">F</ref>). The small rates of pressure change &#8764;1.10 mTorr/s close to the system baseline leakage rate &#8764;0.40 mTorr/s (Figure <ref type="figure">S2</ref>) indicate negligible airflow through the PCTE + G + IP + 0 s O 2 plasma membrane without the formation of nanopores. However, for graphene membranes subjected to 60 s etch, a distinct change is seen in the rate of pressure change before and after testing with 5 nm SiO 2 nanoparticles, indicating that the nanopores are blocked by the &#8764;5 nm particles, which leads to them being filtered out (Figure <ref type="figure">3E,</ref><ref type="figure">F</ref>). We note that such an interpretation is also consistent with the diffusion-driven flow experiments (Figure <ref type="figure">2C</ref>), where the graphene membranes etched for 60 s showed very low transport of Lz &#8764;3.8-4nm. Notably, we did not see an increase in flow due to damage to the graphene from the SiO 2 nanoparticles.</p><p>Increasing the O 2 plasma to 90 s shows no change in rate of pressure for &#8764;5 and &#8764;8 nm particles but shows an apparent change for &#8764;12 nm particles. Further increase in O 2 plasma time to 120 s shows no change for &#8764;12 nm particles, but the same membrane shows a change in rate of pressure for &#8764;20 nm particles (Figure <ref type="figure">3E,</ref><ref type="figure">F</ref>). Finally, some reduction in rate of change in pressure is also observed for &#8764;20 nm particles with 150 s of O 2 , albeit not as significant as for 120 s, which is consistent with prior reports that showed oxygen plasma etching can increase pore size and pore density and that grain boundaries as well as pre-existing defects in graphene can etch at a faster rate than the formation and subsequent enlargement of new defects in the lattice. <ref type="bibr">38,</ref><ref type="bibr">39,</ref><ref type="bibr">53</ref> We note that the graphene membranes subjected to 120 s of O 2 plasma filter &#8764;20 nm particles while exhibiting air permeance of &#8764;7.04 &#215; 10 -4 mol m -2 s -1 Pa -1 (&#8764;75% of air flow of the bare PCTE support). We show that increasing oxygen plasma time results in a larger size of SiO 2 nanoparticles being blocked (Figure <ref type="figure">3E,</ref><ref type="figure">F</ref>). Hence, the track-etched membranes do not completely dominate transport since we see clear differences with increasing oxygen plasma time that result in larger defects in graphene. Taken together, these experiments demonstrate the ability of nanoporous atomically thin graphene membranes to effectively filter aerosolized nanoparticles &#8764;5-20 nm from air streams while maintaining high air flow. We note that the performance of our membranes can be further increased by using supports with larger pores, higher pore density, and lower thickness.</p><p>When comparing our NATM's performance to that of conventional membranes, our results exhibit the ability to block smaller nanoparticles than conventional filters (N95 filter, HEPA filters, TPU-NF). <ref type="bibr">14,</ref><ref type="bibr">15,</ref><ref type="bibr">23,</ref><ref type="bibr">27,</ref><ref type="bibr">57,</ref><ref type="bibr">58</ref> Conventional membranes, such as N95 filters and HEPA filters, have both shown very high rates of permeance (&#8764;4.40 &#215; 10 -2 to 1.08 &#215; 10 -3 mol m -2 s -1 Pa -1 ) but both show permeation of particles &lt;300 nm (HEPA particles show permeation of pollen, dust, and smoke with sizes of 300 nm and smaller, and N95 filters show salt particle permeation below 300 nm). <ref type="bibr">14,</ref><ref type="bibr">15,</ref><ref type="bibr">57,</ref><ref type="bibr">58</ref> As shown in Figure <ref type="figure">4</ref>, our membranes allow for filtering aerosols in the &#8764;5-20 nm range, along with permeance of &#8764;7.04 &#215; 10 -4 mol m -2 s -1 Pa -1 . Conventional membranes are unable to filter aerosols &lt;300 nm but show much higher permeance, while the CNT membranes allow for blockage of &#8764;2 nm particles but with lower permeance than the atomically thin nanoporous graphene membranes. <ref type="bibr">27</ref> Taken together, these observations suggest that our graphene membranes can allow for access to a region in the parameter space which has remained inaccessible for conventional materials (Figure <ref type="figure">S5</ref>) but is highly desirable for PPE for a range of applications in healthcare, defense, and beyond. Measured air permeance as a function of the size of nanoparticles filtered using graphene membranes in this work (red stars) compared to commercial air filters like N95, <ref type="bibr">14</ref> HEPAs, <ref type="bibr">15</ref> PCTE membranes with different pore sizes (10-200 nm), <ref type="bibr">25</ref> and prior reported membranes in the literature, such as PSU/PAN/PA-6 air filter, <ref type="bibr">24</ref> TPU-NF, <ref type="bibr">23</ref> hollow-fiber membranes, <ref type="bibr">22</ref> CNT membranes, <ref type="bibr">27</ref> SAPO-34 membrane, <ref type="bibr">30</ref> and DD3R membrane. <ref type="bibr">29</ref> All air permeance values are measured without taking into account the membrane porosities. Error bars indicate one standard deviation. Also see Figure <ref type="figure">S5</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>&#9632; CONCLUSIONS</head><p>In summary, we demonstrate atomically thin graphene membranes that are able to filter &#8764;5-20 nm particles while maintaining an air permeance of up to &#8764;7.04 &#215; 10 -4 mol m -2 s -1 Pa -1 (&#8764;75% of air flow as that of PCTE supports with 200 nm pores). Furthermore, the facile oxygen plasma etch of the graphene lattice allows for increasing the pore size to selectively filter larger nanoparticles. To the best of our knowledge, this is the first demonstration of an atomically thin membrane which filters nanoparticles in the &#8764;5-20 nm size range. We anticipate that the development of such atomically thin membranes will allow access to a region in the parameter space that has remained inaccessible with conventional materials and will help enable compact, lightweight, and conformal form factors for applications in medical research, healthcare, space, defense, and beyond.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>&#9632; EXPERIMENTAL SECTION</head><p>Graphene Growth. Graphene growth on Cu foil (purity 99.9%, thickness 18 &#956;m, JX Holding HA) was performed by low-pressure CVD as previously reported. <ref type="bibr">34,</ref><ref type="bibr">35,</ref><ref type="bibr">38,</ref><ref type="bibr">39</ref> Surface contaminants on the copper foil were initially removed by sonicating the foil in 15-20% nitric acid, followed by a rinse in de-ionized (DI) water, and dried in air. <ref type="bibr">34,</ref><ref type="bibr">35,</ref><ref type="bibr">38,</ref><ref type="bibr">39</ref> Next, the foil was loaded into a hot-walled tube furnace heated to 1060 &#176;C under 100 sccm of H 2 and annealed for 60 min <ref type="bibr">34,</ref><ref type="bibr">35,</ref><ref type="bibr">38,</ref><ref type="bibr">39</ref> Subsequently, graphene growth was initiated by adding 1 sccm of CH 4 to 100 sccm of H 2 for 30 min, followed by 2 sccm of CH 4 with 100 sccm of H 2 for 30 min <ref type="bibr">34,</ref><ref type="bibr">35,</ref><ref type="bibr">38,</ref><ref type="bibr">39</ref> Finally, the foil was quench cooled in the growth atmosphere.</p><p>Graphene Transfer to PCTE Supports. The graphene on the bottom side of the copper foil was removed by floating the foil in ammonium persulfate (APS, 0.2 M, Thermo Scientific, AC401160020) solution for 30 min, followed by DI water for 10 min, and dried in air. <ref type="bibr">[34]</ref><ref type="bibr">[35]</ref><ref type="bibr">[36]</ref><ref type="bibr">[37]</ref><ref type="bibr">[38]</ref><ref type="bibr">[39]</ref> The graphene on top of the copper foil was then pressed against polycarbonate track-etched (PCTE) support membranes (Sterlitech Corporation, 10 &#956;m thick, polyvinylpyrrolidone-free, hydrophobic, 200 nm cylindrical pores, 10% porosity) . <ref type="bibr">[40]</ref><ref type="bibr">[41]</ref><ref type="bibr">[42]</ref><ref type="bibr">[43]</ref> Next, copper was etched by floating the PCTE/graphene/Cu stack on APS solution. <ref type="bibr">59</ref> The PCTE/graphene stack was finally rinsed by floating it on DI water, followed by a dip in ethanol (200 proof, Fisher Scientific, BP28184), and dried in air.</p><p>Graphene Transfer to SiO 2 /Si Wafer. Graphene on Cu foil was pre-etched in APS solution as described above. Next, &#8764;2 wt % solution of polymethyl methacrylate (PMMA, ACROS, 178760250) in anisole (Beantown Chemical, 130230) was drop-cast on the graphene on the top side of the Cu foil and allowed to dry. The Cu foil was then etched in APS solution, and the PMMA/graphene stack was rinsed in DI water and scooped onto a SiO 2 (300 nm)/Si wafer and dried at 50-80 &#176;C for &#8764;1 h before dissolving the PMMA in acetone and rinsing in isopropanol (IPA, Fisher Chemical, A416P-4).</p><p>Interfacial Polymerization. IP was carried out using octaammonium-POSS (Hybrid Plastics, AM0285) solution (0.4 g of POSS in 20 mL of DI water with a pH of 10.7 by adding NaOH) and trimesoyl-chloride (TMC, Alfa Aesar, 4422-95-1) solutions [0.035 g TMC in 10 mL hexane (VWR, BDH1129)] as previously reported. <ref type="bibr">34,</ref><ref type="bibr">35,</ref><ref type="bibr">38,</ref><ref type="bibr">39,</ref><ref type="bibr">41</ref> Initially, the graphene/PCTE stack was placed on a glass slide on a hot plate at 105 &#176;C for &#8764;12 h <ref type="bibr">38</ref> and subsequently sandwiched between Franz cells (PermeGear, Inc., 0.9 cm diameter orifice) with TMC and POSS solutions filled in the top and bottom cells, respectively, and left to react for 1 h. After IP, the membranes were rinsed with hexane and ethanol on the TMC side, unclamped, and rinsed in ethanol.</p><p>Oxygen Plasma Etching. Oxygen plasma etching was performed using a Harrick Plasma system (PDC-001) using pulses (15 s plasma etching followed by a 120 s pause) with an RF power of 7 W under 500 mTorr oxygen pressure to create nanopores in graphene membranes.</p><p>SEM and Raman Spectroscopy. SEM images of graphene on copper and graphene on PCTE supports were obtained using a Zeiss Merlin SEM with a Gemini II column operated at 2-5 kV.</p><p>Raman spectra for graphene were obtained on samples transferred to SiO 2 /Si substrates using a Thermo Scientific DXR confocal Raman microscope with a 532 nm laser source.</p><p>Evaluating Graphene Membrane Performance. The graphene membranes on PCTE were placed on a perforated steel plate with 0.6 mm diameter holes and clamped via an aluminum tape with a 5 mm diameter hole punched in the center (Figure <ref type="figure">3A</ref>) and loaded into the custom-built test ring. Epoxy was used to seal the edges of the hole punched in the aluminum tape to minimize any leakage.</p><p>Our custom-built test rig/setup (Figures <ref type="figure">3C</ref> and<ref type="figure">S1</ref>) consisted of a 60-gallon vacuum chamber connected to a 3-gallon chamber with a pressure transducer (Omega, model number: PX409-015AUSBH) and a vacuum pump. <ref type="bibr">53</ref> The graphene membrane was mounted into the system and sealed with flanges and gaskets, allowing for consistent experiments (see Figures <ref type="figure">S2-S4</ref> for baseline leakage rates and measured flow rates). After mounting the membrane into the setup, the 60 and 3 gallon chambers were evacuated using a vacuum pump (Edwards RV5) until a base pressure of &#8764;2.5 Torr was reached. Next, air flow through the membrane was measured by monitoring the pressure increase (&#916;pressure, mTorr/s) for 60 s in the system by opening the valve connecting the 3-gallon tank to the membrane holder. Tests were performed in triplicates.</p><p>Filtration of aerosols was tested using various aerosolized silica particles (Nyacol Nano Technologies, &#8764;15-40 wt % in water, <ref type="url">https://www.nyacol.com/products/silicon-dioxide/</ref>). Silica aerosols have a particle size distribution as follows: 5 nm silica (&#8764;4-6 nm), 8 nm silica (&#8764;7-10 nm), 12 nm silica (&#8764;10-14 nm), and 20 nm silica (&#8764;20 nm). Initially, air flow through each membrane was measured without silica particles. Next, silica particles were introduced into the air stream by aerosolizing 0.6 mL of silica particle solution with a specific particle size and allowing the aerosol to pass through the graphene membranes. The rate of change in pressure before and after introducing silica particles was compared. Separate membranes with identical pre-processing were used for each of the silica nanoparticle experiments.</p><p>Diffusion-driven flow of salts and small organic molecules in the liquid phase was measured as described elsewhere. <ref type="bibr">34,</ref><ref type="bibr">39,</ref><ref type="bibr">47,</ref><ref type="bibr">59</ref> The membrane was sandwiched between two side-by-side diffusion cells (PermeGear Inc., 5 mm orifice, 7 mL volume) with graphene facing the feed side and rinsed with ethanol, followed by DI water. Next, the diffusion of KCl, L-tryptophan, vitamin B12, and lysozyme was measured in separate experiments, and magnetic stir bars were used to vigorously stir the feed and permeate side solutions.</p><p>Diffusion-driven transport of KCl was measured by introducing 0.5 M solution of KCl (Fisher Chemical, 7447-40-7 in the feed side with DI water in the permeate side, and the increase in conductivity of the DI water as a function of time was recorded with a conductivity meter (Mettler Toledo SevenCompact S230). The slopes of the curves from 10 min to 15 min were used to calculate the normalized flux for KCl .</p></div><note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_0"><p>https://doi.org/10.1021/acsami.2c10827 ACS Appl. Mater. Interfaces 2022, 14, 41328-41336 Downloaded via VANDERBILT UNIV on July 6, 2023 at 22:37:40 (UTC).See https://pubs.acs.org/sharingguidelines for options on how to legitimately share published articles.</p></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_1"><p>https://doi.org/10.1021/acsami.2c10827</p></note>
		</body>
		</text>
</TEI>
