Determination of alkali elements is important to Earth scientists, yet suitable and reliable microanalytical reference materials are lacking. This paper proposes a new albite reference material and evaluates the potential for future K‐feldspar reference materials. The proposed Piz Beverin albite reference material from Switzerland yields a homogeneous composition at the centimetre‐ to micrometre‐scale for Si, Al and Na with < 2000 μg g‐1total trace elements (mostly heterogeneously distributed Ca, K and Sr). EPMA and LA‐ICP‐MS measurements confirm a composition of 99.5(2)% albite component, which is supported further by bulk XRF measurements. A round robin evaluation involving nine independent EPMA laboratories confirms its composition and homogeneity for Si, Al and Na. In addition, a set of five distinct clear K‐feldspar samples was evaluated as possible reference materials. The first two crystals of adular and orthoclase yield unacceptable inhomogeneities with > 2% relative local variations of Na, K and Ba contents. The three other investigated sets of K‐feldspar crystals are yellow sanidine crystals from Itrongay (Madagascar). Despite distinct compositions, EPMA confirms they are each homogeneous at the centimetre to micrometre scale for Si, Al and K and have no apparent inclusions; further investigation to find larger amounts of these materials is therefore justified.
more » « less- PAR ID:
- 10433308
- Publisher / Repository:
- Wiley-Blackwell
- Date Published:
- Journal Name:
- Geostandards and Geoanalytical Research
- Volume:
- 47
- Issue:
- 4
- ISSN:
- 1639-4488
- Format(s):
- Medium: X Size: p. 907-929
- Size(s):
- p. 907-929
- Sponsoring Org:
- National Science Foundation
More Like this
-
Abundances of minor and trace elements in olivine are increasingly used as petrogenetic indicators for mantle source lithologies, mantle metasomatism history, mantle potential temperatures, and magmatic differentiation. As it is common for olivine to be complexly zoned on a fine-scale, high precision analytical methods for EPMA (electron microprobe microanalyzer, or Electron Microprobe) trace element analysis under high spatial resolution have been developed. However, previous studies have focused more on analytical precision with fewer efforts in examining the accuracy of the data. In this study, we used the Cameca SXFive field emission (FE) EPMA to fully evaluate the effects of beam settings, background offsets and background regression models, and primary calibration standards on the data accuracy of 10 key petrogenetic elements (Na, Al, P, Ca, Ti, Cr, Mn, Co, Ni, and Zn) using MongOlSh11–2 olivine as a reference material. Our results indicate that high voltage, high beam current and long counting time not only improve data precision, but also improve data accuracy, especially on elements with low P/B (peak/background) ratios such as Zn and Cr. Importantly, careful background offsets and background regression models need to be obtained via high resolution WDS relative scans or step scans on each target element. Special care needs to be paid to Co element analysis to avoid or correct for peak interference of Fe Kβ. Among 10 minor and trace elements, exponential background regression models need to be applied to Al, Mn, and Ti elements, whereas other elements require linear background regression. Furthermore, to avoid Al and Zn surface contamination due to alumina polishing or brass presence, ultrasonic cleaning between each intermediate polishing steps and plasma cleaning immediately prior to EPMA experiments is highly recommended. Micro-inclusions such as chromite and spinel in olivine or adjacent Ca-rich phases need to be avoided to minimize primary or secondary fluorescence-related contamination on Al, Cr, or Ca. As a volatile element, Na element needs to be analyzed first with appropriate counting time to minimize the Na loss under high beam conditions. It needs mentioning that major elements (Mg, Fe, and Si) are best analyzed using MongOlSh11–2 or San Carlos olivine as primary standards for calibrations, which can yield more accurate data for both major elements and trace elements because of the improved matrix- corrections. Using our recommended analytical protocols, we have successfully discriminated “depleted” mantle olivine cores from an EMORB in northern East Pacific Rise (EPR) via Ca, Ti, Ni, Co, and Mn abundances. Our olivine data from Siqueiros Transform and the nearby 8◦20′ N seamounts also help reveal a metasomatized peridotite mantle beneath the northern EPR. Overall, the protocols proposed in this study can serve as a guide for accurate EPMA olivine trace element analyses, which potentially contributes to the efforts of fostering a comparable olivine database worldwide.more » « less
-
We present a new set of reference materials, the ND70‐series, for
in situ measurement of volatile elements (H2O, CO2, S, Cl, F) in silicate glass of basaltic composition. The materials were synthesised in piston cylinders at pressures of 1 to 1.5 GPa under volatile‐undersaturated conditions. They span mass fractions from 0 to 6%m/m H2O, from 0 to 1.6%m/m CO2and from 0 to 1%m/m S, Cl and F. The materials were characterised by elastic recoil detection analysis for H2O, by nuclear reaction analysis for CO2, by elemental analyser for CO2, by Fourier transform infrared spectroscopy for H2O and CO2, by secondary ion mass spectrometry for H2O, CO2, S, Cl and F, and by electron probe microanalysis for CO2, S, Cl and major elements. Comparison between expected and measured volatile amounts across techniques and institutions is excellent. It was found however that SIMS measurements of CO2mass fractions using either Cs+or O−primary beams are strongly affected by the glass H2O content. Reference materials have been made available to users at ion probe facilities in the US, Europe and Japan. Remaining reference materials are preserved at the Smithsonian National Museum of Natural History where they are freely available on loan to any researcher. -
Titanite (CaTiSiO5) is a commonly occurring and versatile accessory mineral with broad applications in petrochronology. In situ U-Pb and trace element analyses via SIMS and LA-ICPMS are routinely performed using a matrix-matched reference material for U-Pb and standard glasses (non-matrix matched reference material) for elemental abundance determination. We report U-Pb isotopic ratios and major and trace element concentrations for three titanite samples (Ecstall, McClure and FCT) which are commonly used as reference materials in petrochronology studies. In addition, we characterize two new samples which can potentially serve as matrixmatched reference materials for titanite trace element geochemistry (BLR-2 and BRA-1). Based on electron microprobe analysis, samples BLR-1 and BLR-2 are homogeneous and suitable for use as a primary reference material for trace element concentrations. Whereas Ecstall, McClure, and FCT titanite reference materials show high intra-grain heterogeneity, yielding relative standard deviations for most trace elements between 5% and 40%, with higher standard deviations for U of 70% for Ecstall (n = 26), 265% for McClure (n = 22), and 202% for FCT (n = 26). Therefore, we suggest that these grains are unsuited to serve as reference materials for trace element quantification. The BRA-1 titanite has low trace element concentrations and is chemically heterogeneous (total REE abundances of 40 ppm for the rim and 95 ppm for the core of the grain), thus is not suitable for standardization of chemical composition using LA-ICPMS. It is commonly asserted that a matrix-matched standardization provides a more robust downhole fractionation correction compared to a non-matrix matched standardization. However, it remains unclear which standardization approach (matrix-matched vs non-matrix matched/glass) is more accurate for titanite trace element quantification. To resolve this, we tested several standardization approaches for trace element quantification, comparing matrix-matched (BLR-1) and nonmatrix- matched (NIST612) standardizations with different internal elemental standards (IES; Ca, Si and Ti) and without internal standardization (semi-quantitative). To provide an independent constraint on the accuracy of the various trace element standardization techniques we compared results to trace element concentrations obtained via solution Q-ICPMS on crushed BLR-2 and BRA-1 aliquots. The matrix-matched standardization using Si as the IES yields the best reproducibility of trace element concentrations followed by the matrix-matched reduction using Ti as the IES. Moreover, the matrix-matched semi-quantitative correction yielded the lowest weighted percentage of difference compared to reference trace composition quantified by solution ICPMS. Finally, in this contribution we also benchmark sampling-size for precise U-Pb dating of common-Pb rich phases like titanite.more » « less
-
Extensive experimental studies show that all major rock-forming elements (e.g., Si, Mg, Fe, Ca, Al, Na, K) dissolve in steam to a greater or lesser extent. We use these results to compute chemical equilibrium abundances of rocky-element-bearing gases in steam atmospheres equilibrated with silicate magma oceans. Rocky elements partition into steam atmospheres as volatile hydroxide gases (e.g., Si(OH)4, Mg(OH)2, Fe(OH)2, Ni(OH)2, Al(OH)3, Ca(OH)2, NaOH, KOH) and via reaction with HF and HCl as volatile halide gases (e.g., NaCl, KCl, CaFOH, CaClOH, FAl(OH)2) in much larger amounts than expected from their vapor pressures over volatile-free solid or molten rock at high temperatures expected for steam atmospheres on the early Earth and hot rocky exoplanets. We quantitatively compute the extent of fractional vaporization by defining gas/magma distribution coefficients and show that Earth's subsolar Si/Mg ratio may be due to loss of a primordial steam atmosphere. We conclude that hot rocky exoplanets that are undergoing or have undergone escape of steam-bearing atmospheres may experience fractional vaporization and loss of Si, Mg, Fe, Ni, Al, Ca, Na, and K. This loss can modify their bulk composition, density, heat balance, and interior structure.more » « less
-
We present a novel method for the measurement of lithium isotopes in garnet utilising glass reference materials and secondary ion mass spectrometry (SIMS). Measured lithium isotopic compositions of natural garnets are heterogeneous, making them unreliable reference materials for
in situ determination. However, SIMS lithium isotope measurements of glasses derived from these natural garnets are isotopically identical to their parent garnets and more homogeneous, demonstrating that they can be used as reliable reference materials. To characterise the composition dependence of instrumental mass fractionation (IMF), oxide and silicate powders were used to synthesise custom‐made glass reference materials (CGRMs) with garnet‐equivalent compositions. Results for six CGRMs measured by SIMS show a significant linear relationship between IMF and FeO and MnO contents. Corrections for this compositional IMF result in changes of up to 12‰ within the compositional range explored. Uncertainty in IMF‐corrected SIMS analyses with a 20 μm spot is in the range of 2.5 to 4.5‰, depending on the garnet composition and reference materials used. The method forin situ lithium isotope measurement in garnet by SIMS presented here is highly adaptable, valid across a range of Al‐rich garnet compositions, and yields spatial resolution and precision necessary to address a range of geological applications.