Title: Comparison of the Capacitance of a Cyclically Fatigued Stretch Sensor to a Non-Fatigued Stretch Sensor When Performing Static and Dynamic Foot-Ankle Motions
Motion capture is the current gold standard for assessing movement of the human body, but laboratory settings do not always mimic the natural terrains and movements encountered by humans. To overcome such limitations, a smart sock that is equipped with stretch sensors is being developed to record movement data outside of the laboratory. For the smart sock stretch sensors to provide valuable feedback, the sensors should have durability of both materials and signal. To test the durability of the stretch sensors, the sensors were exposed to high-cycle fatigue testing with simultaneous capture of the capacitance. Following randomization, either the fatigued sensor or an unfatigued sensor was placed in the plantarflexion position on the smart sock, and participants were asked to complete the following static movements: dorsiflexion, inversion, eversion, and plantarflexion. Participants were then asked to complete gait trials. The sensor was then exchanged for either an unfatigued or fatigued plantarflexion sensor, depending upon which sensor the trials began with, and each trial was repeated by the participant using the opposite sensor. Results of the tests show that for both the static and dynamic movements, the capacitive output of the fatigued sensor was consistently higher than that of the unfatigued sensor suggesting that an upwards drift of the capacitance was occurring in the fatigued sensors. More research is needed to determine whether stretch sensors should be pre-stretched prior to data collection, and to also determine whether the drift stabilizes once the cyclic softening of the materials comprising the sensor has stabilized.  more » « less
Award ID(s):
1827652
PAR ID:
10437687
Author(s) / Creator(s):
; ; ; ; ; ; ; ; ; ; ; ; ;
Date Published:
Journal Name:
Sensors
Volume:
22
Issue:
21
ISSN:
1424-8220
Page Range / eLocation ID:
8168
Subject(s) / Keyword(s):
Sponsoring Org:
National Science Foundation
More Like this
  1. Background: An induced loss of balance resulting from a postural perturbation has been reported as the primary source for postural instability leading to falls. Hence; early detection of postural instability with novel wearable sensor-based measures may aid in reducing falls and fall-related injuries. The purpose of the study was to validate the use of a stretchable soft robotic sensor (SRS) to detect ankle joint kinematics during both unexpected and expected slip and trip perturbations. Methods: Ten participants (age: 23.7 ± 3.13 years; height: 170.47 ± 8.21 cm; mass: 82.86 ± 23.4 kg) experienced a counterbalanced exposure of an unexpected slip, an unexpected trip, an expected slip, and an expected trip using treadmill perturbations. Ankle joint kinematics for dorsiflexion and plantarflexion were quantified using three-dimensional (3D) motion capture through changes in ankle joint range of motion and using the SRS through changes in capacitance when stretched due to ankle movements during the perturbations. Results: A greater R-squared and lower root mean square error in the linear regression model was observed in comparing ankle joint kinematics data from motion capture with stretch sensors. Conclusions: Results from the study demonstrated that 71.25% of the trials exhibited a minimal error of less than 4.0 degrees difference from the motion capture system and a greater than 0.60 R-squared value in the linear model; suggesting a moderate to high accuracy and minimal errors in comparing SRS to a motion capture system. Findings indicate that the stretch sensors could be a feasible option in detecting ankle joint kinematics during slips and trips. 
    more » « less
  2. The linearity of soft robotic sensors (SRS) was recently validated for movement angle assessment using a rigid body structure that accurately depicted critical movements of the foot–ankle complex. The purpose of this study was to continue the validation of SRS for joint angle movement capture on 10 participants (five male and five female) performing ankle movements in a non-weight bearing, high-seated, sitting position. The four basic ankle movements—plantar flexion (PF), dorsiflexion (DF), inversion (INV), and eversion (EVR)—were assessed individually in order to select good placement and orientation configurations (POCs) for four SRS positioned to capture each movement type. PF, INV, and EVR each had three POCs identified based on bony landmarks of the foot and ankle while the DF location was only tested for one POC. Each participant wore a specialized compression sock where the SRS could be consistently tested from all POCs for each participant. The movement data collected from each sensor was then compared against 3D motion capture data. R-squared and root-mean-squared error averages were used to assess relative and absolute measures of fit to motion capture output. Participant robustness, opposing movements, and gender were also used to identify good SRS POC placement for foot–ankle movement capture. 
    more » « less
  3. A stretch sensor is a device that attaches to objects and measures the amount by which they deform. These sensors have shown great promise as an alternative to vision-based motion-capture systems, and for robotic sensing. Currently, they are generally limited to linear designs, and require a somewhat challenging calibration process. Our goal is to enableinversedesign of such sensors, and to largely eliminate the calibration process. To this end, we introduce an accurate,differentiablesimulator forcapacitivestretch sensors, that treats both the elasto- andelectro-static parts of the system. Differentiability allows optimizing the geometry of the sensor in order to improve its design for specific applications. We demonstrate the accuracy of our simulator and the effectiveness of our sensor optimization process for various use cases, such as human interfaces and robotics. 
    more » « less
  4. Objective assessment of low back pain (LBP) is challenging due to subtle, task-dependent movement impairments that are poorly captured by existing sensing technologies. Motion Tape (MT), which is a self-adhesive elastic fabric skin strain sensor, enables skin-conforming measurement of localized biomechanical strain during functional movement, but its discriminative utility for LBP remains unclear. We examine this question in a multi-sensor, multi-movement setting and analyze whether MT signals encode discriminative structure that distinguishes individuals with LBP from healthy controls. Using data from 20 participants performing 19 functional movements with six sensors, we evaluate movement-specific classification under a leave-pair-out protocol and examine which movements, sensor placements, and features are most informative. Our analysis reveals that group separation is highly selective: only a small subset of movements, most notably forward flexion, consistently supports accurate classification, while many movements remain at near-chance level. We find that temporal dynamics features help in resolving difficult cases that global strain statistics fail to separate, and that informative signals are spatially localized to the lower lumbar spine. In contrast, pretrained time-series foundation models show negligible sensitivity to participant-level structure in MT signals. Overall, the findings from this exploratory study establish when and how MT sensing can effectively differentiate individuals with LBP from healthy controls, providing a principled foundation for larger-scale validation. 
    more » « less
  5. Abstract The development of wearable technology, which enables motion tracking analysis for human movement outside the laboratory, can improve awareness of personal health and performance. This study used a wearable smart sock prototype to track foot–ankle kinematics during gait movement. Multivariable linear regression and two deep learning models, including long short-term memory (LSTM) and convolutional neural networks, were trained to estimate the joint angles in sagittal and frontal planes measured by an optical motion capture system. Participant-specific models were established for ten healthy subjects walking on a treadmill. The prototype was tested at various walking speeds to assess its ability to track movements for multiple speeds and generalize models for estimating joint angles in sagittal and frontal planes. LSTM outperformed other models with lower mean absolute error (MAE), lower root mean squared error, and higher R -squared values. The average MAE score was less than 1.138° and 0.939° in sagittal and frontal planes, respectively, when training models for each speed and 2.15° and 1.14° when trained and evaluated for all speeds. These results indicate wearable smart socks to generalize foot–ankle kinematics over various walking speeds with relatively low error and could consequently be used to measure gait parameters without the need for a lab-constricted motion capture system. 
    more » « less