Patients on continuous flow ventricular assist devices (CF-VADs) are at high risk for the development of Acquired von-Willebrand Syndrome (AVWS) and non-surgical bleeding. von Willebrand Factor (vWF) plays an essential role in maintaining hemostasis via platelet binding to the damaged endothelium to facilitate coagulation. In CF-VAD patients, degradation of vWF into low MW multimers that are inefficient in facilitating coagulation occurs and has been primarily attributed to the supraphysiological shear stress associated with the CF-VAD impeller. Methods In this review, we evaluate information from the literature regarding the unraveling behavior of surface-immobilized vWF under pulsatile and continuous flow pertaining to: (A) the process of arterial endothelial vWF production and release into circulation, (B) the critical shear stress required to unravel surface bound versus soluble vWF which leads to degradation, and (C) the role of pulsatility in on the production and degradation of vWF. Results and Conclusion Taken together, these data suggests that the loss of pulsatility and its impact on arterial endothelial cells plays an important role in the production, release, unraveling, and proteolytic degradation of vWF into low MW multimers, contributing to the development of AVWS. Restoration of pulsatility can potentially mitigate this issue by preventing AVWS and minimizing the risk of non-surgical bleeding.
more »
« less
Effect of pulsatility on shear‐induced extensional behavior of Von Willebrand factor
Abstract BackgroundPatients with continuous flow ventricular assist devices (CF‐VADs) are at high risk for non‐surgical bleeding, speculated to associate with the loss of pulsatility following CF‐VAD placement. It has been hypothesized that continuous shear stress causes elongation and increased enzymatic degradation of von Willebrand Factor (vWF), a key player in thrombus formation at sites of vascular damage. However, the role of loss of pulsatility on the unravelling behavior of vWF has not been widely explored. MethodsvWF molecules were immobilized on the surface of microfluidic devices and subjected to various pulsatile flow profiles, including continuous flow and pulsatile flow of different magnitudes,dQ/dt(i.e., first derivative of flow rate) of pulsatility and pulse frequencies to mimic in vivo shear flow environments with and without CF‐VAD support. VWF elongation was observed using total internal reflection fluorescence (TIRF) microscopy. Besides, the vWF level is measured from the patients’ blood sample before and after CF‐VAD implantation from a clinical perspective. To our knowledge, this work is the first in providing direct, visual observation of single vWF molecule extension under controlled‐pulsatile shear flow. ResultsUnravelling of vWF (total sample sizen ~ 200 molecules) is significantly reduced under pulsatile flow (p < 0.01) compared to continuous flow. An increase in the magnitude of pulsatility further reduces unravelling lengths, while lower frequency of pulsatility (20 vs. 60 pulses per min) does not have a major effect on the maximum or minimum unravelling lengths. Evaluation of CF‐VAD patient blood samples (n = 13) demonstrates that vWF levels decreased by ~40% following CF‐VAD placement (p < 0.01), which correlates to single‐molecule observations from a clinical point of view. ConclusionsPulsatile flow reduces unfolding of vWF compared to continuous flow and a lower pulse frequency of 20 pulses/minute yielded comparable vWF unfolding to 60 pulses/minute. These findings could shed light on non‐surgical bleeding associated with the loss of pulsatility following CF‐VAD placement.
more »
« less
- Award ID(s):
- 2004475
- PAR ID:
- 10446025
- Publisher / Repository:
- Wiley-Blackwell
- Date Published:
- Journal Name:
- Artificial Organs
- Volume:
- 46
- Issue:
- 5
- ISSN:
- 0160-564X
- Page Range / eLocation ID:
- p. 887-898
- Format(s):
- Medium: X
- Sponsoring Org:
- National Science Foundation
More Like this
-
-
Nonsurgical bleeding occurs in a significant proportion of patients implanted with continuous-flow ventricular assist devices (CF-VADs) and is associated with nonphysiologic flow with diminished pulsatility. An in vitro vascular pulse perfusion model seeded with adult human aortic endothelial cells (HAECs) was used to identify biomarkers sensitive to changes in pulsatility. Diminished pulsatility resulted in an ~45% decrease in von Willebrand factor (vWF) levels from 9.80 to 5.32 ng/ml (n = 5, p < 0.05) and a threefold increase in angiopoietin-2 (ANGPT-2) levels from 775.29 to 2471.93 pg/ml (n = 5, p < 0.05) in cultured HAECs. These changes are in agreement with evaluation of patient blood samples obtained pre-CF-VAD implant and 30-day postimplant: a decrease in plasma vWF level by 50% from ~45.59 to ~22.49 μg/ml (n = 15, p < 0.01) and a 64% increase in plasma ANGPT-2 level from 7,073 to 11,615 pg/ml (n = 8, p < 0.05). This study identified vWF and ANGPT-2 as highly sensitive to changes in pulsatility, in addition to interleukin-6 (IL-6), IL-8, and tumor necrosis-α (TNF-α). These biomarkers may help determine the optimal level of pulsatility and help identify patients at high risk of nonsurgical bleeding.more » « less
-
Smart polymers that mimic and even surpass the functionality of natural responsive materials have been actively researched. This study explores the design and characterization of a Single-MOlecule-based material REsponsive to Shear (SMORES) for the targeted release of A1, the platelet binding domain of the blood clotting protein von Willebrand factor (VWF). Each SMORES construct employs an aptamer molecule as the flow transducer and a microparticle to sense and amplify the hydrodynamic force. Within the construct, the aptamer, ARC1172, undergoes conformational changes beyond a shear stress threshold, mimicking the shear-responsive behavior of VWF. This conformational alteration modulates the bioavailability of its target, the VWF-A1 domain, ultimately releasing it at elevated shear. Through optical tweezer-based single-molecule force measurement, ARC1172s role as a force transducer was assessed by examining its unfolding under constant pulling force. We also investigated its refolding rate as a function of force under varied relaxation periods. These analyses revealed a narrow range of threshold forces (3–7 pN) governing the transition between folded and unfolded states. We subsequently constructed the SMORES material by conjugating ARC1172 and a microbead, and immobilizing the other end of the aptamer on a substrate. Single-molecule flow experiments on immobilized SMORES constructs revealed a peak A1 domain release within a flow rate range of (40–70 μL min−1). A COMSOL Multiphysics model translated these flow rates to total forces of 3.10 pN–5.63 pN experienced by the aptamers, aligning with single-molecule force microscopy predictions. Evaluation under variable flow conditions showed a peak binding of A1 to the platelet glycoprotein Ib (GPIB) within the same force range, confirming released payload functionality. Building on knowledge of aptamer biomechanics, this study presents a new strategy to create shear-stimulated biomaterials based on single biomolecules.more » « less
-
Abstract Helical blood flow, characterized by its spiral motion, is a crucial physiological phenomenon observed in various circulatory structures, including the heart, aorta, vessel bifurcations, umbilical cord, and respiratory system. Despite its importance, a comprehensive understanding of helical flow dynamics is limited. This study aims to investigate the transition from laminar to turbulent flow in helical tubes under both steady and pulsatile conditions. An experimental setup was developed, featuring a closed-loop system with a pulsatile flow generator and steady pump, producing sinusoidal waveforms with adjustable frequencies and amplitudes. Five helical tube models, varying in curvature radius and torsion, were fabricated with a fixed inner diameter of 15 mm. High-frequency pressure transducers, ultrasonic flow sensors, and Laser Doppler Velocimetry (LDV) were employed to visualize flow fields and measure turbulence kinetic energy (TKE). Results indicate that helical tube geometry significantly impacts turbulence transitions. Specifically, larger curvature radii stabilize the flow and reduce turbulence downstream, while smaller radii lead to earlier transitions to turbulence. Under steady flow conditions, the critical Reynolds number (Re) for turbulence onset was found to be around 2300 upstream, similar to straight pipes, but significantly higher turbulence levels were observed downstream. Pulsatile flow with high pulsatility indices (PI > 3) near transitional Re markedly increases turbulence, particularly downstream, with large bursts of turbulence occurring during the deceleration phase. These findings enhance the understanding of helical flow dynamics and have implications for biomedical device design, diagnostics, and treatments for circulatory disorders.more » « less
An official website of the United States government