skip to main content


Title: A Mediator‐Free Electroenzymatic Sensing Methodology to Mitigate Ionic and Electroactive Interferents' Effects for Reliable Wearable Metabolite and Nutrient Monitoring
Abstract

Wearable electroenzymatic sensors enable monitoring of clinically informative biomolecules in epidermally retrievable biofluids. Conventional wearable enzymatic sensors utilize Prussian Blue (a redox mediator) to achieve selectivity against electroactive interferents. However, the use of Prussian Blue presents fundamental challenges including: 1) the susceptibility of the sensor response to dynamic concentration variation of ionic species and 2) the poor operational stability due to the degradation of its framework. As an alternative wearable electroenzymatic sensor development methodology to bypass the aforementioned limitations, a mediator‐free sensing interface is devised, comprising of a coupled platinum nanoparticle/multiwall carbon nanotube layer and a permselective membrane. The interface is adapted to develop sensors targeting glucose, lactate, and choline (as examples of informative metabolites and nutrients), showing high degrees of sensitivity, selectivity (against a wide panel of naturally present and diverse interfering species), stability (<6.5% signal drift over 20 h operation), and reliability of sensing operation in sweat samples. By integration within a readout board, a wireless sample‐to‐answer system is realized for on‐body sweat biomarker analysis. This methodology can be adapted to target a wide panel of biomarkers in various biofluids, introducing a new sensor development direction for personal health monitoring.

 
more » « less
NSF-PAR ID:
10457775
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
Advanced Functional Materials
Volume:
30
Issue:
10
ISSN:
1616-301X
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract

    Nutrients are essential for the healthy development and proper maintenance of body functions in humans. For adequate nourishment, it is important to keep track of nutrients level in the body, apart from consuming sufficient nutrition that is in line with dietary guidelines. Sweat, which contains rich chemical information, is an attractive biofluid for routine non‐invasive assessment of nutrient levels. Herein, a wearable sensor that can selectively measure vitamin C concentration in biofluids, including sweat, urine, and blood is developed. Detection through an electrochemical sensor modified with Au nanostructures, LiClO4‐doped conductive polymer, and an enzymes‐immobilized membrane is utilized to achieve wide detection linearity, high selectivity, and long‐term stability. The sensor allows monitoring of temporal changes in vitamin C levels. The effect of vitamin C intake on the sweat and urine profile is explored by monitoring concentration changes upon consuming different amounts of vitamin C. A longitudinal study of sweat's and urine's vitamin C correlation with blood is performed on two individuals. The results suggest that sweat and urine analysis can be a promising method to routinely monitor nutrition through the sweat sensor and that this sensor can facilitate applications such as nutritional screening and dietary intervention.

     
    more » « less
  2. To achieve the mission of personalized medicine, centering on delivering the right drug to the right patient at the right dose, therapeutic drug monitoring solutions are necessary. In that regard, wearable biosensing technologies, capable of tracking drug pharmacokinetics in noninvasively retrievable biofluids (e.g., sweat), play a critical role, because they can be deployed at a large scale to monitor the individuals’ drug transcourse profiles (semi)continuously and longitudinally. To this end, voltammetry-based sensing modalities are suitable, as in principle they can detect and quantify electroactive drugs on the basis of the target’s redox signature. However, the target’s redox signature in complex biofluid matrices can be confounded by the immediate biofouling effects and distorted/buried by the interfering voltammetric responses of endogenous electroactive species. Here, we devise a wearable voltammetric sensor development strategy—centering on engineering the molecule–surface interactions—to simultaneously mitigate biofouling and create an “undistorted potential window” within which the target drug’s voltammetric response is dominant and interference is eliminated. To inform its clinical utility, our strategy was adopted to track the temporal profile of circulating acetaminophen (a widely used analgesic and antipyretic) in saliva and sweat, using a surface-modified boron-doped diamond sensing interface (cross-validated with laboratory-based assays,R2∼ 0.94). Through integration of the engineered sensing interface within a custom-developed smartwatch, and augmentation with a dedicated analytical framework (for redox peak extraction), we realized a wearable solution to seamlessly render drug readouts with minute-level temporal resolution. Leveraging this solution, we demonstrated the pharmacokinetic correlation and significance of sweat readings.

     
    more » « less
  3. Abstract

    Wearable sweat sensors have the potential to revolutionize precision medicine as they can non‐invasively collect molecular information closely associated with an individual's health status. However, the majority of clinically relevant biomarkers cannot be continuously detected in situ using existing wearable approaches. Molecularly imprinted polymers (MIPs) are a promising candidate to address this challenge but haven't yet gained widespread use due to their complex design and optimization process yielding variable selectivity. Here, QuantumDock is introduced, an automated computational framework for universal MIP development toward wearable applications. QuantumDock utilizes density functional theory to probe molecular interactions between monomers and the target/interferent molecules to optimize selectivity, a fundamentally limiting factor for MIP development toward wearable sensing. A molecular docking approach is employed to explore a wide range of known and unknown monomers, and to identify the optimal monomer/cross‐linker choice for subsequent MIP fabrication. Using an essential amino acid phenylalanine as the exemplar, experimental validation of QuantumDock is performed successfully using solution‐synthesized MIP nanoparticles coupled with ultraviolet–visible spectroscopy. Moreover, a QuantumDock‐optimized graphene‐based wearable device is designed that can perform autonomous sweat induction, sampling, and sensing. For the first time, wearable non‐invasive phenylalanine monitoring is demonstrated in human subjects toward personalized healthcare applications.

     
    more » « less
  4. Abstract

    Wearable health monitoring has garnered considerable interest from the healthcare industry as an evolutionary alternative to standard practices with the ability to provide rapid, off‐site diagnosis and patient‐monitoring. In particular, sweat‐based wearable biosensors offer a noninvasive route to continuously monitor a variety of biomarkers for a range of physiological conditions. Both the accessibility and wealth of information of sweat make it an ideal target for noninvasive devices that can aid in early diagnosis of disease or to monitor athletic performance. Here, the integration of ammonium (NH4+) and calcium (Ca2+) ion‐selective membranes with a poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate)‐based (PEDOT:PSS) organic electrochemical transistor (OECT) for multiplexed sensing of NH4+and Ca2+in sweat with high sensitivity and selectivity is reported for the first time. The presented wearable sweat sensor is designed by combining a flexible and stretchable styrene‐ethylene‐butene‐styrene substrate with a laser‐patterned microcapillary channel array for direct sweat acquisition and delivery to the ion‐selective OECT. The resulting dermal sensor exhibits a wide working range between 0.01 × 10−3and 100 × 10−3m, well within the physiological levels of NH4+and Ca2+in sweat. The integrated devices are successfully implemented with both ex situ measurements and on human subjects with real‐time analysis using a wearable sensor assembly.

     
    more » « less
  5. Abstract

    Wearable sensors that can conveniently detect cytokine levels in human biofluids are essential for assisting hospitals to maximize the benefits of anti‐inflammatory therapies and avoid cytokine storms. Measurement of cytokine levels in biofluids still remains challenging for existing sensors due to high interference from the background. Here, this challenge is overcome through developing a flexible and regenerative aptameric field‐effect transistor biosensor, consisting of a graphene–Nafion composite film, for detecting cytokine storm biomarkers in undiluted human biofluids. The composite film enables the minimization of nonspecific adsorption and empowers the renewability to the biosensor. With these capabilities, the device is capable of consistently and sensitively monitoring cytokines (e.g., IFN‐γ, an inflammatory and cancer biomarker) in undiluted human sweat with a detection range from 0.015 to 250 nmand limit of detection down to 740 fm. The biosensor is also shown to incur no visible mechanical damage and maintain a consistent sensing response throughout the regenerative (up to 80 cycles) and crumpling (up to 100 cycles) tests. Experimental results demonstrate that the biosensor is expected to offer opportunities for developing wearable biosensing systems for distinguishing acute infectious disease patients and monitoring of patients’ health conditions in daily life.

     
    more » « less