skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Systematic Analysis of the Smooth Muscle Wall Phenotype of the Pharyngeal Arch Arteries During Their Reorganization into the Great Vessels and Its Association with Hemodynamics
ABSTRACT Early outflow morphogenesis is a critical event in cardiac development. Understanding mechanical and molecular based morphogenetic relationships at early stages of cardiogenesis is essential for the advancement of cardiovascular technology related to congenital heart defects. In this study, we pair molecular changes in pharyngeal arch artery (PAA) vascular smooth muscle cells (VSMCs) with hemodynamic changes over the course of the same period. We focus on Hamburger Hamilton stage 24–36 chick embryos, using both Doppler ultrasound and histological sections to phenotype PAA VSMCs, and establish a relationship between hemodynamics and PAA composition. Our findings show that PAA VSMCs transition through a synthetic, intermediate, and contractile phenotype over time. Wall shear stress magnitude per arch varies throughout development. Despite distinct hemodynamic and fractional expression trends, no strong correlation was found between the two, indicating that WSS magnitude is not the main driver of PAA wall remodeling and maturation. While WSS magnitude was not found to be a major driver, this work provides a basic framework for investigating relationships between hemodynamic forces and tunica media during a critical period of development. Anat Rec, 302:153–162, 2019. © 2018 Wiley Periodicals, Inc.  more » « less
Award ID(s):
1635712
PAR ID:
10458171
Author(s) / Creator(s):
 ;  ;  
Publisher / Repository:
Wiley Blackwell (John Wiley & Sons)
Date Published:
Journal Name:
The Anatomical Record
Volume:
302
Issue:
1
ISSN:
1932-8486
Format(s):
Medium: X Size: p. 153-162
Size(s):
p. 153-162
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Mechanical forces are essential for proper growth and remodeling of the primitive pharyngeal arch arteries (PAAs) into the great vessels of the heart. Despite general acknowledgement of a hemodynamic-malformation link, the direct correlation between hemodynamics and PAA morphogenesis remains poorly understood. The elusiveness is largely due to difficulty in performing isolated hemodynamic perturbations and quantifying changes in-vivo. Previous in-vivo arch artery occlusion/ablation experiments either did not isolate the effects of hemodynamics, did not analyze the results in a 3D context or did not consider the effects of varying degrees of occlusion. Here, we overcome these limitations by combining minimally invasive occlusion experiments in the avian embryo with 3D anatomical models of development and in-silico testing of experimental phenomenon. We detail morphological and hemodynamic changes 24 hours post vessel occlusion. 3D anatomical models showed that occlusion geometries had more circular cross-sectional areas and more elongated arches than their control counterparts. Computational fluid dynamics revealed a marked change in wall shear stress-morphology trends. Instantaneous (in-silico) occlusion models provided mechanistic insights into the dynamic vessel adaptation process, predicting pressure-area trends for a number of experimental occlusion arches. We follow the propagation of small defects in a single embryo Hamburger Hamilton (HH) Stage 18 embryo to a more serious defect in an HH29 embryo. Results demonstrate that hemodynamic perturbation of the presumptive aortic arch, through varying degrees of vessel occlusion, overrides natural growth mechanisms and prevents it from becoming the dominant arch of the aorta. 
    more » « less
  2. Abstract A three‐dimensional direct numerical simulation model coupled with the immersed boundary method has been developed to simulate a pulsatile flow in a planar channel with single and double one‐sided semicircular constrictions. For relevance to blood flow in large arteries, simulations have been performed at Reynolds numbers of 750 and 1000. Flow physics and resultant wall shear stress (WSS)‐based hemodynamic parameters are presented. The instantaneous vortex dynamics, mean flow characteristics, and turbulent energy spectra are evaluated for flow physics. Subsequently, three WSS‐based parameters, namely the time‐averaged WSS, oscillatory shear index, and relative residence time, are calculated over the stenotic wall and correlated with flow physics to identify the regions prone to atherosclerotic plaque progression. Results show that the double stenotic channel leads to high‐intensity and broadband turbulent characteristics downstream, promoting critical values of the WSS‐based parameters in the post‐stenotic areas. In addition, the inter‐space area between two stenoses displays multiple strong recirculations, making this area highly prone to atherosclerosis progression. The effect of stenosis degree on the WSS‐based parameters is studied up to 60% degree. As the degree of occlusion is increased, larger regions are involved with the nonphysiological ranges of the WSS‐based parameters. 
    more » « less
  3. Background and objective: Wall shear stress (WSS) has been known to play a critical role in the development of several complications following coronary artery stenting, including in-stent restenosis and thrombosis. Computational fluid dynamics is often used to quantify the post-stenting WSS, which may potentially be used as a predictive metric. However, large-scale studies for WSS-based risk stratification often neglect the footprint of the stent due to reconstruction challenges. The primary objective of this study is to statistically evaluate the impact of the stent footprints (Xience and Resolute stents) on the computed endothelial WSS and quantitatively identify the relationship between these local hemodynamic alterations and the global properties of the vessel, such as curvature, on WSS. The ultimate goal is to evaluate whether and when it is worth including the footprint of the stent in an in-silico study to compute the WSS reliably. Methods: A previously developed semi-automated reconstruction approach for patient-specific coronaries was employed as a part of the SHEAR-STENT trial. A subset of patients was analyzed (N=30), and CFD simulations were performed with and without the stent to evaluate the impact of the stent footprint on WSS. Due to the computationally expensive nature of transient analyses, a sub-cohort of ten patients were used to assess the reliability of WSS obtained from steady computations as a surrogate for the time-averaged results. Global and local vessel curvature data were extracted for all cases and evaluated against stent-induced alterations in the WSS. The differences between the Xience and Resolute stent platforms were also examined to quantify each stent's unique WSS footprint. Results: Results from the surrogate analysis indicate that steady WSS serves as an excellent approximation of the time-averaged computations. The presence of either stent footprint causes a statistically significant decrease in the space-averaged WSS, and a significant increase in the endothelial regions exposed to very low WSS as well (<0.5 Pa). Negative correlations were observed between vessel curvature and WSS differences, indicating that macroscopic vessel characteristics play a more prominent role in determining endothelial WSS at higher curvature values. In our pool of cases, comparison of Xience and Resolute stents revealed that the Resolute platform seems to lead to lower space-averaged WSS and an increase in areas of very low WSS. Conclusion: These results outline (1) the necessity of including the stent footprint for accurate in-silico WSS analysis; (2) the global features of stented arteries serving as the dominant determinant of WSS past a certain curvature threshold; and (3) the Xience stent resulting in a milder presence of hemodynamically unfavorable WSS regions compared to the Resolute stent. Keywords: Computational fluid dynamics; Drug-eluting stents; In-silico clinical trials; Percutaneous coronary intervention; Wall shear stress. 
    more » « less
  4. Atherosclerosis-related cardiovascular diseases are a leading cause of mortality worldwide. Vascular smooth muscle cells (VSMCs) comprise the medial layer of the arterial wall and undergo phenotypic switching during atherosclerosis to a synthetic phenotype capable of proliferation and migration. The surrounding environment undergoes alterations in extracellular matrix (ECM) stiffness and composition in addition to an increase in addition to an increase in cholesterol content. Using an atherosclerotic murine model, we analyzed how the mechanics of VSMCs isolated from western diet fed apolipoprotein-E knockout (ApoE -/- ) and wild type (WT) mice were altered during atherosclerosis. Increased stiffness of ApoE -/- VSMCs correlated with a greater degree of stress fiber alignment as evidenced by atomic force microscopy (AFM)-generated force maps and stress fiber topography images. On type-1 collagen (COL1)-coated polyacrylamide (PA) gels of varying stiffness, WT VSMCs had higher adhesion forces to N-Cadherin (N-Cad) and COL1. ApoE -/- VSMC stiffness was significantly greater than WT cells with increased cell stiffness with increasing substrate stiffness for both ApoE -/- and WT VSMCs . In addition, ApoE -/- VSMCs showed an enhanced migration capability on COL1-coated substrates and a general decreasing trend in migration capacity with increasing substrate stiffness, correlating with the lower adhesion forces as compared to WT VSMCs. Altogether, these results demonstrate the potential contribution of the alteration in VSMC mechanics in the development of atherosclerosis. 
    more » « less
  5. ABSTRACT ObjectiveTortuous microvessels are characteristic of microvascular remodeling associated with numerous physiological and pathological scenarios. Three‐dimensional (3D) hemodynamics in tortuous microvessels influenced by red blood cells (RBCs), however, are largely unknown, and important questions remain. Is blood viscosity influenced by vessel tortuosity? How do RBC dynamics affect wall shear stress (WSS) patterns and the near‐wall cell‐free layer (CFL) over a range of conditions? The objective of this work was to parameterize hemodynamic characteristics unique to a tortuous microvessel. MethodsRBC‐resolved simulations were performed using an immersed boundary method‐based 3D fluid dynamics solver. A representative tortuous microvessel was selected from a stimulated angiogenic network obtained from imaging of the rat mesentery and digitally reconstructed for the simulations. The representative microvessel was a venule with a diameter of approximately 20 μm. The model assumes a constant diameter along the vessel length and does not consider variations due to endothelial cell shapes or the endothelial surface layer. ResultsMicrovessel tortuosity was observed to increase blood apparent viscosity compared to a straight tube by up to 26%. WSS spatial variations in high curvature regions reached 23.6 dyne/cm2over the vessel cross‐section. The magnitudes of WSS and CFL thickness variations due to tortuosity were strongly influenced by shear rate and negligibly influenced by tube hematocrit levels. ConclusionsNew findings from this work reveal unique tortuosity‐dependent hemodynamic characteristics over a range of conditions. The results provide new thought‐provoking information to better understand the contribution of tortuous vessels in physiological and pathological processes and help improve reduced‐order models. 
    more » « less