Title: Assessment of two brands of fentanyl test strips with 251 synthetic opioids reveals “blind spots” in detection capabilities
Abstract BackgroundFentanyl test strips (FTS) are a commonly deployed tool in drug checking, used to test for the presence of fentanyl in street drug samples prior to consumption. Previous reports indicate that in addition to fentanyl, FTS can also detect fentanyl analogs like acetyl fentanyl and butyryl fentanyl, with conflicting reports on their ability to detect fentanyl analogs like Carfentanil and furanyl fentanyl. Yet with hundreds of known fentanyl analogs, there has been no large-scale study rationalizing FTS reactivity to different fentanyl analogs. MethodsIn this study, 251 synthetic opioids—including 214 fentanyl analogs—were screened on two brands of fentanyl test strips to (1) assess the differences in the ability of two brands of fentanyl test strips to detect fentanyl-related compounds and (2) determine which moieties in fentanyl analog chemical structures are most crucial for FTS detection. Two FTS brands were assessed in this study: BTNX Rapid Response and WHPM DanceSafe. ResultsOf 251 screened compounds assessed, 121 compounds were detectable at or below 20,000 ng/mL by both BTNX and DanceSafe FTS, 50 were not detectable by either brand, and 80 were detectable by one brand but not the other (n = 52 BTNX,n = 28 DanceSafe). A structural analysis of fentanyl analogs screened revealed that in general, bulky modifications to the phenethyl moiety inhibit detection by BTNX FTS while bulky modifications to the carbonyl moiety inhibit detection by DanceSafe FTS. ConclusionsThe different “blind spots” are caused by different haptens used to elicit the antibodies for these different strips. By utilizing both brands of FTS in routine drug checking, users could increase the chances of detecting fentanyl analogs in the “blind spot” of one brand.  more » « less
Award ID(s):
2016516
PAR ID:
10478156
Author(s) / Creator(s):
;
Publisher / Repository:
Springer Science + Business Media
Date Published:
Journal Name:
Harm Reduction Journal
Volume:
20
Issue:
1
ISSN:
1477-7517
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. Abstract BackgroundFentanyl test strips (FTS) are lateral flow immunoassay strips designed for detection of ng/mL levels of fentanyl in urine. In 2021, the US Centers for Disease Control and the Substance Abuse and Mental Health Administration stated that federal funds could be used for procurement of FTS for harm reduction strategies approved by the government such as drug checking. The market for FTS has expanded rapidly in the US and Canada. However, there is no regulatory oversight by either government to ensure proper function of FTS that are being marketed for drug checking. Main bodyMany brands of FTS have rapidly entered the harm reduction market, creating concerns about the reproducibility and accuracy of their performance from brand to brand and lot to lot. Some examples are provided in this Comment. Similar problems with product quality were observed in the mid 2000’s when lateral flow immunoassays for malaria were funded in many countries and again in 2020, when COVID-19 tests were in huge demand. The combination of high demand and low levels of regulation and enforcement led some manufacturers to join the goldrush without adequate field testing or quality assurance. We argue that the harm reduction community urgently needs to set a lot checking program in place. A set of simple protocols for conducting the tests and communicating the results have been developed, and are described in the following Perspectives paper in this issue. ConclusionIn the absence of governmental regulation and enforcement, the harm reduction community should implement a FTS lot checking program. Based on previous experience with the malaria diagnostic lot checking program, this inexpensive effort could identify products that are not suitable for harm reduction applications and provide valuable feedback to manufacturers. Dissemination of the results will help harm reduction organizations to ensure that FTS they use for drug checking are fit for the purpose. 
    more » « less
  2. Abstract Background The opioid epidemic has caused an increase in overdose deaths which can be attributed to fentanyl combined with various illicit substances. Drug checking programs have been started by many harm reduction groups to provide tools for users to determine the composition of their street drugs. Immunoassay fentanyl test strips (FTS) allow users to test drugs for fentanyl by either filling a baggie or cooker with water to dissolve the sample and test. The antibody used in FTS is very selective for fentanyl at high dilutions, a characteristic of the traditional use of urine testing. These street sample preparation methods can lead to mg/mL concentrations of several potential interferents. We tested whether these concentrated samples could cause false positive results on a FTS. Methods 20 ng/mL Rapid Response FTS were obtained from BTNX Inc. and tested against 4 different pharmaceuticals (diphenhydramine, alprazolam, gabapentin, and naloxone buprenorphine) and 3 illicit stimulants [cocaine HCl, methamphetamine, and 3,4-methylenedioxymethamphetamine (MDMA)] in concentrations from 20 to 0.2 mg/mL. The FTS testing pad is divided into 2 sections: the control area and the test area. Control and test area signal intensities were quantified by ImageJ from photographs of the test strips and compared to a threshold set by fentanyl at the FTS limit of detection. Results False positive results indicating the presence of fentanyl were obtained from samples of methamphetamine, MDMA, and diphenhydramine at concentrations at or above 1 mg/mL. Diphenhydramine is a common cutting agent in heroin. The street sample preparation protocols for FTS use suggested by many online resources would produce such concentrations of these materials. Street samples need to be diluted more significantly to avoid interference from potential cutting agents and stimulants. Conclusions Fentanyl test strips are commercially available, successful at detecting fentanyl to the specified limit of detection and can be a valuable tool for harm reduction efforts. Users should be aware that when drugs and adulterants are in high concentrations, FTS can give a false positive result. 
    more » « less
  3. Abstract Synthetic opioids, especially fentanyl and its analogs, have created an epidemic of abuse and significantly increased overdose deaths in the United States. Current detection methods have drawbacks in their sensitivity, scalability, and portability that limit field‐based application to promote public health and safety. The need to detect trace amounts of fentanyl in complex mixtures with other drugs or interferents, and the continued emergence of new fentanyl analogs, further complicates detection. Accordingly, there is an urgent need to develop convenient, rapid, and reliable sensors for fentanyl detection. In this study, a sensor is prepared based on competitive displacement of a fluorescent dye from the cavity of a supramolecular macrocycle, with subsequent fluorescence quenching from graphene quantum dots. This approach can detect and quantify small quantities of fentanyl along with 58 fentanyl analogs, including highly potent variants like carfentanil that are of increasing concern. Detection of these agents is possible even at 0.01 mol% in the presence of common interferents. This simple, rapid, reliable, sensitive, and cost‐effective approach couples supramolecular capture with graphene quantum dot nanomaterial quenchers to create a tool with the potential to advance public health and safety in the context of field‐based detection of drugs in the fentanyl class. 
    more » « less
  4. Abstract Small‐molecule allosteric activators of the enzyme sarco/endoplasmic reticulum calcium ATPase (SERCA) hold promise as novel experimental tools to manipulate intracellular calcium concentrations and as therapeutic agents to treat medical conditions associated with elevated cytosolic calcium levels. Here, we synthesized and characterized 20 analogs of the known allosteric SERCA activator CDN1163 and tested their ability to stimulate SERCA activity. The structures of the compounds varied in the alkyl group of the parent scaffold's ether moiety as well as in the composition of the nitrogenous aromatic ring system. The most active compounds exhibited potencies in the sub‐micromolar range while increasing enzyme activity by more than 25 %. The observed structure‐activity relationships indicated that bulky alkyl groups in the ether moiety along with a quinoline ring methyl substituent were beneficial for activity. Replacement of the quinoline by a pyrimidine ring system reduced activity. To conceive a potential mechanism of action, we generated a molecular model of the transition state of SERCA when undergoing the rate‐limiting step of its catalytic cycle. Subsequent blind docking with CDN1163 identified a high‐affinity binding site close to the enzyme's ATP binding pocket, suggesting that the activators may accelerate SERCA's catalytic cycle by aiding in ATP binding and positioning. 
    more » « less
  5. Hughes, Kelly T (Ed.)
    ABSTRACT New approaches for combating microbial infections are needed. One strategy for disrupting pathogenesis involves developing compounds that interfere with bacterial virulence. A critical molecular determinant of virulence for Gram-negative bacteria are efflux pumps of the resistance-nodulation-division family, which includes AcrAB-TolC. We previously identified small molecules that bind AcrB, inhibit AcrAB-TolC, and do not appear to damage membranes. These efflux pump modulators (EPMs) were discovered in an in-cell screening platform called SAFIRE (Screen for Anti-infectives using Fluorescence microscopy of IntracellulaR Enterobacteriaceae). SAFIRE identifies compounds that disrupt the growth of a Gram-negative human pathogen,Salmonella entericaserotype Typhimurium (S. Typhimurium), in macrophages. We used medicinal chemistry to iteratively design ~200 EPM35 analogs and test them for activity in SAFIRE, generating compounds with nanomolar potency. Analogs were demonstrated to bind AcrB in a substrate binding pocket by cryo-electron microscopy. Despite having amphipathic structures, the EPM analogs do not disrupt membrane voltage, as monitored by FtsZ localization to the cell septum. The EPM analogs had little effect on bacterial growth in standard Mueller Hinton Broth. However, under broth conditions that mimic the micro-environment of the macrophage phagosome,acrABis required for growth, the EPM analogs are bacteriostatic, and the EPM analogs increase the potency of antibiotics. These data suggest that under macrophage-like conditions, the EPM analogs prevent the export of a toxic bacterial metabolite(s) through AcrAB-TolC. Thus, compounds that bind AcrB could disrupt infection by specifically interfering with the export of bacterial toxic metabolites, host defense factors, and/or antibiotics. IMPORTANCEBacterial efflux pumps are critical for resistance to antibiotics and for virulence. We previously identified small molecules that inhibit efflux pumps (efflux pump modulators, EPMs) and prevent pathogen replication in host cells. Here, we used medicinal chemistry to increase the activity of the EPMs against pathogens in cells into the nanomolar range. We show by cryo-electron microscopy that these EPMs bind an efflux pump subunit. In broth culture, the EPMs increase the potency (activity), but not the efficacy (maximum effect), of antibiotics. We also found that bacterial exposure to the EPMs appear to enable the accumulation of a toxic metabolite that would otherwise be exported by efflux pumps. Thus, inhibitors of bacterial efflux pumps could interfere with infection not only by potentiating antibiotics, but also by allowing toxic waste products to accumulate within bacteria, providing an explanation for why efflux pumps are needed for virulence in the absence of antibiotics. 
    more » « less