<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Two-Dimensional Tellurium Nanosheets for the Efficient Nonenzymatic Electrochemical Detection of H2O2</title></titleStmt>
			<publicationStmt>
				<publisher>MDPI, Basel, Switzerland</publisher>
				<date>02/01/2024</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10504443</idno>
					<idno type="doi">10.3390/chemosensors12020017</idno>
					<title level='j'>Chemosensors</title>
<idno>2227-9040</idno>
<biblScope unit="volume">12</biblScope>
<biblScope unit="issue">2</biblScope>					

					<author>Amit Kumar Shringi</author><author>Rajeev Kumar</author><author>Netanya F. Dennis</author><author>Fei Yan</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[<p>This study reports, for the first time, the utilization of two-dimensional (2D) tellurium (Te) nanosheets for the efficient nonenzymatic detection of hydrogen peroxide (H2O2). H2O2 acts as a pivotal biomarker with widespread applications across environmental, biological, industrial, and food processing domains. However, an excessive accumulation of H2O2 in the body poses a severe threat to human life. Consequently, the imperative need for a selective, sensitive, and cost-effective sensing platform for H2O2 detection has gained paramount significance. Employing a low-cost and straightforward hydrothermal method, Te nanosheets were synthesized to address the escalating demand for a reliable detection platform. The as-synthesized Te nanosheets are characterized through Raman spectroscopy and atomic force microscopy techniques. The electrochemical performance of the Te nanosheets integrated onto a glassy carbon (Te-GC) electrode was thoroughly investigated using cyclic voltammetry, differential pulse voltammetry, and chronoamperometry. The experiments were designed to evaluate the response of the Te-GC electrode in the presence and absence of H2O2, alongside its performance in the detection of other pertinent interfering analytes. The sensor shows a limit of detection of 0.47 µM and a sensitivity of 27.2 µA µM−1 cm−2 towards H2O2. The outcomes of this study demonstrate the efficacy of Te nanosheets as a promising material for nonenzymatic H2O2 detection in urine samples. The simplicity and cost-effectiveness of the hydrothermal synthesis process, coupled with the notable electrochemical performance of the Te/GC electrode, highlight the potential of Te nanosheets in the development of a robust sensing platform. This research contributes to the ongoing efforts to enhance our capabilities in monitoring and detecting H2O2, fostering advancements in environmental, biomedical, and industrial applications.</p>]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="1.">Introduction</head><p>Hydrogen peroxide (H 2 O 2 ) is a strong oxidizer and a volatile inorganic compound of biological, clinical, and industrial importance <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[4]</ref>. For industrial uses, it is used for bleaching, chemical synthesis, and water treatment <ref type="bibr">[5]</ref><ref type="bibr">[6]</ref><ref type="bibr">[7]</ref>. Due to wide applications and the natural formation of H 2 O 2 , it can be present in the environment, water surfaces, body fluids, and food <ref type="bibr">[8,</ref><ref type="bibr">9]</ref>. The amount of H 2 O 2 present in the environment defines the quality of air and water. In biological systems, it plays an important role in metabolism, signaling, biosynthetic reactions, and oxidative stress <ref type="bibr">[10,</ref><ref type="bibr">11]</ref>. H 2 O 2 is involved in cellular signaling processes at lower concentrations. However, excess levels can disrupt normal cellular signaling pathways, leading to the dysregulation of various physiological functions. Excess H 2 O 2 in the body can lead to various adverse effects due to its potent oxidizing properties. While H 2 O 2 is produced as a byproduct of normal cellular metabolism and is involved in certain physiological processes, an imbalance or excessive accumulation can be harmful. H 2 O 2 is a member of reactive oxygen species (ROS), and in excess, it can cause oxidative stress. This stress arises from an imbalance between the production of ROS and the body's ability to eliminate them. It is important to note that the body has defense mechanisms, including antioxidant enzymes and molecules, to counteract the effects of reactive oxygen species. Nonetheless, when the balance between oxidants and antioxidants is disrupted, the risk of oxidative damage and associated health issues increases. Conditions that promote the accumulation of excess H 2 O 2 include certain diseases, environmental factors, and exposure to certain chemicals.</p><p>According to the Occupational Safety and Health Administration (OSHA), the permissible limit of H 2 O 2 in the air is about 1 ppm and inhalation beyond 75 ppm can immediately endanger health and life <ref type="bibr">[12]</ref>. Oxidative stress can damage cellular components, including proteins, lipids, and DNA, which may lead to impaired cell function and contribute to various diseases. Elevated levels of H 2 O 2 can trigger an inflammatory response in the body. Recent studies suggest that the level of H 2 O 2 present in human blood plasma can be in the low range of 0.25 &#181;M to a probable normal range of 1-5 &#181;M, and a high range of 30-50 &#181;M in certain disease states (e.g., diabetes) or during chronic inflammation <ref type="bibr">[13]</ref>. Intracellular H 2 O 2 content under normal circumstances is usually f10 nM <ref type="bibr">[14,</ref><ref type="bibr">15]</ref>. Chronic inflammation is associated with numerous health conditions, including cardiovascular diseases, neurodegenerative disorders (such as Alzheimer's and Parkinson's), and autoimmune diseases. The concentration of H 2 O 2 in body fluids and exhaled breath can determine health conditions, particularly pulmonary diseases and diabetes <ref type="bibr">[16]</ref><ref type="bibr">[17]</ref><ref type="bibr">[18]</ref><ref type="bibr">[19]</ref>. The brain is particularly vulnerable to oxidative damage due to its high oxygen consumption and lipid content. Excess H 2 O 2 can contribute to the oxidation of low-density lipoprotein (LDL), promoting atherosclerosis. H 2 O 2 can interact with DNA, causing modifications and mutations. This DNA damage can lead to the development of cancer and contribute to aging-related symptoms. In addition, excessive H 2 O 2 can affect the functioning of immune cells, which may lead to a compromised immune system, making the body more susceptible to infections and illnesses.</p><p>Furthermore, H 2 O 2 can be found in processed and packaged food products. The consumption of processed food with high concentrations of H 2 O 2 can lead to serious gastrointestinal diseases <ref type="bibr">[7]</ref>. Food products containing folic acid can form H 2 O 2 during their decomposition and its high concentrations can affect the nutritional values <ref type="bibr">[20]</ref>. Hence, an additional process is required to decompose the excess H 2 O 2 <ref type="bibr">[21]</ref>. In this regard, many countries have already established food safety regulations for the safe limit of H 2 O 2 in the final products <ref type="bibr">[22]</ref><ref type="bibr">[23]</ref><ref type="bibr">[24]</ref>. The ingestion and inhalation of H 2 O 2 above the safe limits can cause severe health issues for human beings <ref type="bibr">[25,</ref><ref type="bibr">26]</ref>. Therefore, the detection and determination of H 2 O 2 concentration in the environment, human body fluids, and food products to ensure that the levels remain below the safe limit have great importance.</p><p>To ensure the accurate detection of H 2 O 2 levels, a variety of analytical techniques such as chromatography, titrimetry, spectrophotometry, colorimetry, fluorescence, and phosphorescence have been developed and tested <ref type="bibr">[27]</ref><ref type="bibr">[28]</ref><ref type="bibr">[29]</ref><ref type="bibr">[30]</ref><ref type="bibr">[31]</ref>. However, these analytical techniques have their technical drawbacks, like their poor selectivity and sensitivity, complexity, time-consuming nature, and expensive instrumentation. In recent years, electrochemical sensors have been proven as a suitable choice due to their low cost, high sensitivity, excellent selectivity, and fast response, and offer a portable and convenient operation for the accurate and selective sensing of H 2 O 2 <ref type="bibr">[10]</ref>. In comparison with conventional and commercially used analytical techniques like chromatography, the use of electrochemical sensors is more favorable because of their compact size, cost-effectiveness, and fast response, along with easy remote monitoring. The enzymatic electrochemical sensing approach shows excellent sensing performance with good sensitivity and selectivity, but it comes with the limitations of complex immobilization processes and instabilities driven by physical conditions <ref type="bibr">[32,</ref><ref type="bibr">33]</ref>. In enzymatic detection, the temperature and pH of the medium alter the sensing performance dramatically <ref type="bibr">[34]</ref>. Furthermore, the high cost of enzymes is a limiting factor in the fabrication of an enzymatic biosensor and its wide applicability. In recent years, huge efforts have been made to overcome the limitations of enzymatic biosensors, and have led to a nonenzymatic or direct electrochemical sensing approach <ref type="bibr">[10]</ref>. The nonenzymatic biosensors modified with suitable catalysts show excellent detection capabilities for different analytes or biomarkers <ref type="bibr">[35]</ref>. A nonenzymatic biosensor offers ease of fabrication, is inexpensive and robust, and has a longer life <ref type="bibr">[36]</ref>. These sensors have less impact of physical conditions on the sensing performance compared to enzymatic sensing. Furthermore, the nonenzymatic sensors show direct charge transfer and enhanced surface renewability.</p><p>In electrochemical sensing, catalysts significantly influence overall sensing performance. Therefore, a variety of nanostructured materials, including metal oxides, metal nanoparticles (NPs), 2D transition-metal dichalcogenides (TMDs), and monoelemental nanomaterials, have been investigated for the nonenzymatic detection of H 2 O 2 .The use of nanomaterials offers a higher surface area with fast charge transfer to promote the reaction of analyte over the surface <ref type="bibr">[37]</ref>. Hence, the controlled growth or synthesis of nanomaterials with lower dimensions can be a suitable approach to achieve improved sensing performance in electrochemical sensing.</p><p>Metal nanostructure-based nonenzymatic sensors show excellent detection and selectivity towards H 2 O 2 <ref type="bibr">[38]</ref>. Metal NPs also have been studied as composites with other nanomaterials like carbon nanotubes (CNT) for the efficient detection of H 2 O 2 <ref type="bibr">[39,</ref><ref type="bibr">40]</ref>. Except for metal NPs, metal oxide composites such as NiO NPs/CNT have been reported for the selective detection of H 2 O 2 with a limit of detection (LOD) of 1 &#181;M <ref type="bibr">[41]</ref>. Recently, Fe 2 O 3 /Graphene nanocomposite has been reported with a low LOD of 4.79 &#181;M and detectivity of 0.037 &#181;A &#181;M -1 cm -2 [42]. The TMDs-modified electrode, MoS 2 /graphene nanocomposite, demonstrated high sensitivity and selectivity towards H 2 O 2 in the presence of interfering analytes with a wide linear response from 0.25 to 16 mM H 2 O 2 <ref type="bibr">[43]</ref>. Composites and metal NPs-modified catalysts have always been the prime choice for detection applications, but to reduce the complexity and improve the scalability, other approaches like doping have also been explored for sensitive and selective electrochemical detection. Nitrogen doping in carbon nanofibers has been demonstrated for the selective detection of H 2 O 2 with a sensitivity of 357 &#181;A &#181;M -1 cm -2 <ref type="bibr">[44]</ref>.</p><p>Te is a p-type semiconductor having a band gap of ~0.32 eV with excellent physical and chemical characteristics <ref type="bibr">[45,</ref><ref type="bibr">46]</ref>. Te nanostructures have been reported for optical, piezoelectric, thermoelectric, electrochemical, and sensing properties <ref type="bibr">[47]</ref><ref type="bibr">[48]</ref><ref type="bibr">[49]</ref><ref type="bibr">[50]</ref>. The synthesis of Te nanostructures has been reported and optimized over the years using different synthesis methods with controlled dimensionalities <ref type="bibr">[46,</ref><ref type="bibr">47,</ref><ref type="bibr">51]</ref>. Nanostructured Te has been reported for its good catalytic and storage properties. The application of Te nanoparticles and nanowires for the nonenzymatic detection of H 2 O 2 has been investigated by various research groups <ref type="bibr">[45,</ref><ref type="bibr">[50]</ref><ref type="bibr">[51]</ref><ref type="bibr">[52]</ref><ref type="bibr">[53]</ref><ref type="bibr">[54]</ref><ref type="bibr">[55]</ref>. As previously discussed, the sensing performance is notably influenced by nanostructure dimensions <ref type="bibr">[52]</ref>. To attain superior H 2 O 2 detection performance, this study introduces the use of 2D Te nanosheets for nonenzymatic electrochemical detection. The low-cost synthesis approach of 2D Te nanosheets makes it suitable over the other direct growth approaches.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.">Material and Methods</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.1.">Materials and Reagents</head><p>Sodium tellurite pentahydrate (Na 2 TeO 3 &#8226;5H 2 O) from Tokyo Chemical Industries (Tokyo, Japan), hydrazine hydrate (N 2 H 4 &#8226;H 2 O, Hydrazine, 64%) from Thermo Scientific (Fair Lawn, NJ, USA), and ammonium hydroxide solution (NH 4 OH) from Fisher Scientific (Fair Lawn, NJ, USA) and polyvinylpyrrolidone (PVP, K85-95, MW 13,000,000) were purchased and used in the synthesis reaction without further purification. De-ionized water (DI water, &lt;18 &#8486;) was used for synthesis, cleaning, and solution preparation. H 2 O 2 (30%, Fisher, Fair Lawn, NJ, USA), dopamine hydrochloride (C 8 H 11 NO 2 &#8226;HCl, 99%, Alfa Aesar, Ward Hill, MA, USA), ascorbic acid (C 6 H 8 O 6 , Ward's Science, Rochester, NY, USA), uric acid (99%, Alfa Aesar, Ward Hill, MA, USA), and sodium chloride (NaCl, Fisher Scientific, Fair Lawn, NJ, USA) were procured and used as analytes for sensing without further purification. Phosphate-buffered saline (PBS, pH 7.4, 1X molarity) was used as an electrolyte medium.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.2.">Synthesis of Te Nanosheets</head><p>Te nanosheets were synthesized by a conventional hydrothermal route, as shown in Figure <ref type="figure">1</ref>. Initially, 3 g of PVP was dissolved in 30 mL of DI water under continuous stirring until a clear solution was obtained. Further, 10 mM of Na 2 TeO 3 &#8226;5H 2 O was added to the PVP solution and stirred for 4 hrs. Afterward, 3.2 mL of NH 4 OH and 1.7 mL of N 2 H 4 &#8226;H 2 O were added to the above solution and stirred for 1 h. The final solution was then transferred to the Teflon-lined autoclave and heated at 180 &#8226; C for 24 h. After 24 h, the autoclave was taken out for natural cooling and the collection of the final product. The collected solution was washed with water and purified by centrifugation at 5000 rpm for three cycles. After cleaning, the Te nanosheets solution appears in a silver gray color. The final product shows the formation of a few Te nanowires along with Te nanosheets. </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.3.">Material Characterizations</head><p>A high-resolution optical microscope (Olympus BX61, Olympus, Tokyo, Japan) was used to capture the optical images of the obtained Te nanosheets. The topography, morphology, and thickness profile of the Te nanosheets were recorded using AIST-NT Smart SPM integrated with a RAMAN microscope (Horiba semiconductor, Piscataway, NY, USA). The Horiba LabRAM Evolution RAMAN microscope was used to obtain the Raman spectra of the Te nanosheets.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.4.">Electrode Modification and Sensing Characterization</head><p>The glassy carbon electrode (GCE) from BAS Inc. with a 3 mm inner diameter was used for sensing characterizations. Before use, the GCE was polished using the alumina slurry of different particle sizes followed by ultrasonication in DI water for 5 min. Finally, the GCE was rinsed with ethanol and DI water and dried in the oven.</p><p>Then, 1 mg/mL of chitosan solution was prepared in diluted acetic acid (1% aqueous) solution by sonication for 30 min. Sonicated Te nanosheets suspension (150 &#181;L) was mixed with 1 mL of the chitosan solution, drop cast on GCE, and dried at 60 &#8226; C for 30 min. A total volume of 5 &#181;L of the mixture was dropped on GCE for the modified electrode.</p><p>The electrochemical sensing characterization of the Te nanosheets/GC-modified electrodes (Te-GC) was carried out using the Voltammetric Analyzer (CV-50W, Bioanalytical Systems, Inc., West Lafayette, IN, USA). The sensitivity of the instrument was set at 100 &#181;A/V for all measurements. The sensing measurements were recorded using the conventional three-electrode configuration with platinum (Pt) as the counter electrode and Ag/AgCl (3.5 M KCl) as the reference electrode. Three-electrode assembly was connected to the cell stand (C3, BAS Inc., West Lafayette, IN, USA) with controlled stirring and gas purging. Cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CA) signals were recorded to examine the sensing performance towards H 2 O 2 and other analytes (uric acid, NaCl, dopamine, and ascorbic acid). For the electrochemical measurements, 15 mL of PBS was taken in the voltammetric cell and purged with nitrogen for 30 min, with stirring at 400 rpm. Once the electrodes were connected, the stirring and purging was momentarily stopped to record the CV and DPV scans. The initial CV and DPV scans of the electrode, in blank electrolyte, i.e., without H 2 O 2 addition, were performed. Subsequently, 150 &#181;L of H 2 O 2 from 20 &#181;M stock solution was added. The effective concentration of H 2 O 2 in the electrolyte was 100 times lower. Purging and stirring were continued for 5 min with each addition of H 2 O 2 . For the chronoamperometry tests, analytes of 1 M concentrations were prepared. Since uric acid has negligible solubility in water, a 0.39 M solution of this analyte was prepared. 150 &#181;L of these analyte stock solutions was periodically added at 100 s time intervals. The concentration of the interferant analytes (uric acid, NaCl, dopamine, and ascorbic acid) was purposefully kept high to study the efficacy of the Te sample towards H 2 O 2 detection. The chronoamperometry test was also conducted with a 2 &#181;M concentration of the interferants, which is within the normal range in human specimens.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.">Results and Discussion</head></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.1.">Microscopic and Spectroscopic Characterization of Te Nanosheets</head><p>Optical microscopy is a widely accepted way to confirm the formation of large area 2D nanosheets. Initially, the formation of Te nanosheets was confirmed using a highresolution optical microscope. We also observed the formation of a few nanowires along with nanosheets. Figure <ref type="figure">2a</ref> illustrates a typical optical image of the sample. The reaction yields a higher number of nanosheets compared to nanowires, approximately in an 80% to 20% ratio, and we found that the length of nanosheets was &gt;20 &#181;m and width &gt;5 &#181;m, as shown in Figure <ref type="figure">2b</ref>.</p><p>Atomic force microscopy (AFM) serves as an invaluable tool for characterizing nanomaterials due to its high-resolution imaging capabilities and precise topographical analysis. Tellurium, a semiconductor material, when synthesized into nanosheets, exhibits unique properties that can be elucidated through AFM. By utilizing a sharp probe that scans the surface of the nanosheets, AFM generates topographic maps revealing the morphology, thickness, and surface roughness at the atomic or near-atomic scale. This comprehensive analysis through AFM plays a pivotal role in advancing the understanding and potential applications of Te nanosheets in various fields, including electronics, optoelectronics, and energy storage. We transferred the Te nanosheets to the SiO 2 substrate to examine the morphological and thickness profile. A 10 &#181;m &#215; 10 &#181;m area containing Te nanosheets was selected to obtain the surface morphology imaging (Figure <ref type="figure">2c</ref>) and height profile data (Figure <ref type="figure">2d</ref>). A silicon (Si) tip with a length 225 &#181;m and a tip radius &lt; 40 nm was used for scanning. We scanned the sample with a scan rate of 0.3 Hz in the noncontact mode. The average surface roughness on the Te nanosheets was 0.3 nm and the height profile showed a thickness of ~80 nm. Raman spectroscopy serves as a powerful tool in characterizing the structural and vibrational properties of Te nanosheets. These two-dimensional materials exhibit a unique electronic and optical behavior due to their ultrathin nature and quantum confinement effects. The Raman spectra of Te nanosheets unveil invaluable insights into their phonon modes, stacking configurations, and layer thickness. The distinct peaks observed in the spectra correspond to the vibrational modes associated with the lattice vibrations and provide crucial information about the crystalline quality and structural integrity of the nanosheets. Additionally, Raman spectroscopy aids in identifying any potential doping, defects, or strain present in these nanomaterials, contributing significantly to their characterization and potential applications in various fields, including electronics, optoelectronics, and sensing technologies. The Raman spectrum for Te nanosheets was recorded using 532 nm laser excitation. Te nanosheets exhibit characteristic Raman peaks related to their crystal structure.</p><p>The Raman peaks observed in Te nanosheets at 92.05, 123.47, and 143.56 cm -1 related to E 1-To , A 1g , and E phonon mode vibrations, as shown in Figure <ref type="figure">2e</ref>. Te nanosheets show different Raman-active phonon vibration modes due to their high atomic number and the existence of electronic polarizability. The Te unit cell contains three atoms, and it leads to an infinite chain parallel to the c-axis. The most intense peak at 123.47 cm -1 for the A 1 mode is due to symmetric intrachain stretching, compression, and bending in the basal plane <ref type="bibr">[52,</ref><ref type="bibr">53]</ref>. The second strong peak at 92 cm -1 is due to the chain orientation along the a-and b-axis named the E 1 mode. The peak at 143.56 cm -1 for Te nanosheets is assigned to the E 2 mode and it usually arises due to asymmetric expansion along the c-axis. The Raman spectrum for Te nanosheets shows good agreement with the existing literature with slight shifting in the peaks <ref type="bibr">[52]</ref>. Raman spectra confirm the crystalline and phase pure nature of the synthesized Te nanosheets.</p><p>The photoluminescence (PL) spectra for Te nanosheets were recorded using a 473 nm laser excitation to examine optical properties. The PL spectrum of bulk Te does not exhibit any PL emission due to the small bandgap (~0.32 eV) in the far infrared (IR) range <ref type="bibr">[54]</ref>. In contrast, recently Nyugen et al. found that the PL spectrum of the Te nanocrystals shows a broad PL peak in the visible range owing to the quantum confinement of excitons <ref type="bibr">[55]</ref>. The PL spectra (Figure <ref type="figure">2f</ref>) of our synthesized Te nanosheets also show a broad peak in the visible range and can similarly originate from the quantum confinement of excitons. During relaxation, these electrons recombine with holes in the valence band and emit light in the visible range due to the alteration of the density of state near the edges.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.2.">Electrochemical Sensing Performance</head><p>The fabrication process of the sensor and the suggested mechanism for H 2 O 2 sensing based on Te nanosheets are illustrated in Figure <ref type="figure">S1</ref> (Supporting Information). The CV and DPV scans were measured simultaneously at a particular concentration in the potential range of 600 to -900 mV with respect to the Ag/AgCl reference electrode. The scans were carried out at a scan rate of 10 mV/s in a negative polarity setting from the high potential to low potential region. The CV scans are plotted (according to the US convention) in Figure <ref type="figure">3a,</ref><ref type="figure">b</ref>. The CV scans of blank GC, Te-GC without H 2 O 2 , and Te-GC with 0.2 &#181;M H 2 O 2 are plotted in Figure <ref type="figure">3a</ref>. The CV signal for Te-GC shows the distinct redox peaks. The concentrations of H 2 O 2 tested were in the range of 0.2-5 &#181;M, which is the normal range found in human blood plasma <ref type="bibr">[13]</ref>. We observe two prominent peaks at 235 and -405 mV, which can be assigned to oxidation and reduction reactions, respectively. This indicates that these peaks originate from an irreversible conversion of Te to TeO 2 and vice versa. It is well established that metallic nanostructures develop a thin oxidized layer on their surface when processed in ambient conditions. Considering the centrifugation, storage, and electrode preparation in an aqueous environment, the partial surface oxidation of the metallic Te nanosheets is inevitable. The reduction peak could be attributed to the reduction of TeO 2 to metallic Te. In the reverse CV scan, Te metal converts back to TeO 2 . The redox reactions can be represented by the following equations <ref type="bibr">[56]</ref>:</p><p>In the presence of H 2 O 2 , the oxidation of Te to TeO 2 becomes more prominent. The oxidizing environment provided by H 2 O 2 is expected to inhibit the reduction of TeO 2 to Te, leading to a decrease in signal (at negative potential) in both CV and DPV with higher H 2 O 2 concentrations. The concentrations of H 2 O 2 tested were in the range of 0.2-5 &#181;M, which is the normal range found in human blood plasma <ref type="bibr">[13]</ref>.</p><p>As can be observed in Figure <ref type="figure">3b</ref>,c, the peak current of both the redox peaks decreases with increasing H 2 O 2 concentration. Manikandan et al. <ref type="bibr">[56]</ref> also observed the decreasing trend in peak current intensity with increasing H 2 O 2 concentration using Te nanoparticles, although no possible reason was mentioned by them. This observation of decreasing intensity also aligns with the findings of Teodoro et al. <ref type="bibr">[57]</ref>, who used UV Vis spectroscopy to detect H 2 O 2 with Ag nanoparticles. They observed the decrease in spectral intensity with increasing H 2 O 2 concentration, which was ascribed to the degradation on the Ag nanoparticles at higher concentrations of H 2 O 2 . Since the H 2 O 2 can undergo a disproportionation reaction to form H 2 O (reduction) and O 2 (oxidation), it is possible that the metal nanoparticle catalyst can get oxidized at higher concentrations. However, this may not be the only plausible reason. The saturation of active sites (i.e., passivation at high analyte concentration) on the metal catalyst can also lead to decreased sensitivity, which is observed in our study as a saturation stage in the CV and DPV profiles. The DPV results also show a similar trend to the CV scans (Figure <ref type="figure">3c</ref>). Since the sensitivity of the DPV technique is higher as compared to CV <ref type="bibr">[57]</ref>, the analysis of the LOD and sensitivity (S) were performed using the DPV data. DPV eliminates the capacitive contribution of the current response and thus, it shows lower values than the CV scans in our case. The LOD and sensitivity (S) can be obtained from the plot of the peak current with respect to the concentration of the analyte <ref type="bibr">[58,</ref><ref type="bibr">59]</ref>, as per the equations below.</p><p>where, &#963; is the standard deviation of the response, k is the slope of the calibration curve, and A is the area of the working electrode in cm 2 . As can be observed from Figure <ref type="figure">3d</ref>, the plot of the peak current vs. the concentration of H 2 O 2 has two distinct linear regimes: one below the concentration of 1 &#181;M and another in the range of 1-5 &#181;M. The LOD and S evaluated in the lower concentration range were found to be 0.47 &#181;M and 27.2 &#181;A &#181;M -1 cm -2 , respectively. The LOD and S in the higher concentration range were evaluated as 0.19 &#181;M and 2.2 &#181;A &#181;M -1 cm -2 , respectively. It is understandable that Te nanosheets are more suitable for H 2 O 2 detection at the low concentrations. At high concentrations, the saturation of active sites and the reduction of TeO 2 to metallic Te are inhibited, resulting in a decrease in sensitivity. Consequently, two linear ranges are observed. Two sets of DPV experiment results (Figure <ref type="figure">S2</ref>, Supporting information) showcase the reproducibility of H 2 O 2 sensing. The lower potential range demonstrates superior sensitivity and less inhibition, as depicted in Figure <ref type="figure">S2</ref> of the Supporting Information. Table <ref type="table">1</ref> presents a comparative analysis of various Te-based sensors for H 2 O 2 detection.</p><p>The chronoamperometry tests were conducted with a fresh working electrode. The Te-GC electrode showed no response for uric acid and NaCl (Figure <ref type="figure">4a,</ref><ref type="figure">b</ref>). However, positive and negative current responses were observed for dopamine and ascorbic acid, respectively. Tsai et al. utilized Te nanowires for the detection of dopamine <ref type="bibr">[60]</ref>, so our results are in line with their observation. Ascorbic acid, being a reducing agent, should show an opposite response compared to H 2 O 2 . The chronoamperometric response for low concentrations of H 2 O 2 is very weak in the presence of highly concentrated interferants. A positive response was visible only beyond 1 mM H 2 O 2 concentrations, which is effectively 1/10th times the interferant concentration. In the presence of interferants at concentrations of 0.2 &#181;M (within the normal range in humans), the signals from dopamine and ascorbic acid were too faint to distinguish from the background. Interestingly, in this scenario, the signal from 100 &#181;M H 2 O 2 is still clearly visible. The chronoamperometric response at different concentrations of H 2 O 2 in PBS solution without the interferants notably showed a detectable signal for a 10 &#181;M concentration (see Figure <ref type="figure">4b,</ref><ref type="figure">c</ref>). However, a clear signal is observed for a concentration of 100 &#181;M.  </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.3.">Analysis of Real Samples</head><p>To assess the practical applicability of our sensor, DPV measurements were conducted on urine samples from two individuals (Figure <ref type="figure">5</ref>). The urine samples needed to be diluted to observe a signal within the potential window of 600 to -900 mV. When using very high amounts of urine in the test solution, the signal was faint (Figure <ref type="figure">5c</ref>). The analysis indicates that for this Te nanosheets-based sensor, the optimal amount of testing analyte should be in the range of 100-500 &#181;L (in 15 mL of PBS). This corresponds to an H 2 O 2 amount in the range of 0.5-4 &#181;M/mL of urine.</p><p>--ffi </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="4.">Conclusions</head><p>The synthesis of Te nanosheets was successfully achieved through a facile, one-pot hydrothermal method, resulting in nanosheets with an approximate thickness of 80 nm. The crystallinity and purity of the Te nanosheets were verified through the analysis of the Raman spectrum. Subsequently, the nonenzymatic detection capabilities of a GCE modified with Te nanosheets were systematically investigated. The Te nanosheets-modified electrode underwent characterization through CV and DPV, revealing exceptional sensitivity and selectivity towards H 2 O 2 . The electrode exhibited a LOD of 0.47 &#181;M and a sensitivity of 27.2 &#181;A &#181;M -1 cm -2 . These findings underscore the efficacy of Te nanosheets in facilitating the detection of H 2 O 2 . Importantly, the results suggest the practical application of Te nanosheets in detecting H 2 O 2 within human body fluids. This holds significant promise for diagnostic and monitoring purposes in healthcare. Furthermore, the two-dimensional nature of these nanosheets opens avenues for their potential use in the development of flexible and wearable biosensors. In conclusion, the successful synthesis of Te nanosheets, their effective modification of electrodes, and the promising electrochemical performance indicate the feasibility of incorporating these nanomaterials into practical applications, especially in the realm of biosensing. The versatility demonstrated in this study not only enhances our understanding of Te nanosheets, but also paves the way for innovative advancements in the field of nanotechnology and sensor development.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Supplementary Materials:</head><p>The following supporting information can be downloaded at: <ref type="url">https: //www.mdpi.com/article/10.3390/chemosensors12020017/s1</ref>, Figure <ref type="figure">S1</ref>: Top: Illustration depicting the sensor fabrication process. Bottom: Proposed mechanism for H 2 O 2 sensing utilizing Te nanosheets. </p></div></body>
		</text>
</TEI>
