<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Sigma vector calculations in nodal aberration theory and experimental validation using a Cassegrain telescope</title></titleStmt>
			<publicationStmt>
				<publisher>Optics Express</publisher>
				<date>12/01/2023</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10506523</idno>
					<idno type="doi">10.1364/OE.502744</idno>
					<title level='j'>Optics Express</title>
<idno>1094-4087</idno>
<biblScope unit="volume">31</biblScope>
<biblScope unit="issue">25</biblScope>					

					<author>Meltem Yeşiltepe</author><author>Aaron Bauer</author><author>Özgür Karcı</author><author>Jannick P. Rolland</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[Nodal Aberration Theory (NAT) was developed to explain the field dependency of aberration field centers in the image plane of nominally rotationally symmetric optical systems that have lost their symmetry through misalignments. A new insight into the theory led to calculating the sigma vectors, which locate the aberration field centers, using the angle between a real-ray trace of the optical axis ray (OAR) and the normal of the local surface where “local” refers to the object and image optical spaces of that surface. Here, we detail the sigma vector calculations for general optical systems and provide an experimental investigation of a misaligned system with a high-precision customized Cassegrain telescope. In the simulations, a Newtonian telescope, a Cassegrain telescope, and a three-mirror anastigmat telescope were misaligned intentionally in ray-tracing software. The sigma vectors were calculated analytically for the third-order aberrations of astigmatism and coma. Experimentally, the same perturbations were implemented for the Cassegrain telescope system, and the aberrations were quantified through interferometric measurements on a grid of field points in the image plane that verified the analytical derivation and simulations.]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="1.">Introduction</head><p>Nodal Aberration Theory (NAT) describes and quantifies the aberration properties of nominally rotationally symmetric optical systems that are misaligned. NAT builds upon H.H. Hopkins' scalar wave aberration theory <ref type="bibr">[1]</ref> and R. Buchroeder's concept of the shifted aberration field centers on the image plane for misaligned optical systems <ref type="bibr">[2]</ref>. The theory, invented by R.V. Shack, was developed up to the fifth order by K. P. . Experimental investigations of NAT are still in progress. N. Zhao et al. first experimentally demonstrated field-constant coma for an aplanatic Ritchey-Chretien telescope <ref type="bibr">[9]</ref>. Next, the experimental investigation of binodal astigmatism, which was the aberration field dependence that led to the discovery of NAT <ref type="bibr">[10]</ref>, was first experimentally validated for a customized Cassegrain telescope <ref type="bibr">[11]</ref>, followed by the validation of the separation of binodal astigmatism induced by mount error and misalignment <ref type="bibr">[12]</ref>, and field-linear coma for a Cassegrain telescope <ref type="bibr">[13]</ref>.</p><p>NAT predicts that the aberrations of misaligned optical systems show new field dependency and nodal behavior (i.e., where an aberration goes to zero), but there are no new aberration types. The exact locations of the aberration field centers or nodes in the image plane are determined by a weighted sum of the individual surface contributions in the optical system. For this purpose, Buchroeder developed a method based on paraxial ray-tracing for perturbations of small tilts and decenters <ref type="bibr">[2]</ref>. Afterward, <ref type="bibr">Thompson et al. put</ref> forth a new insight for locating the aberration field centers based on real-ray-trace data that is valid for any misalignments <ref type="bibr">[14]</ref>. In this method, sigma vectors to locate the aberration field centers were calculated using the angle between a real-ray trace of the optical axis ray (OAR) and the normal of the local surface. This angle is entirely free of how the misalignments are modeled and can be obtained from optical design software. This approach in NAT provides valuable insight to the optical designers, such as evaluating the alignment state of an optical system and the fruitfulness of the compensators in assembly.</p><p>Here, we review and detail the calculation of sigma vectors in NAT for a general optical system. The calculations are verified numerically using ray-tracing software for one, two, and three-mirror systems. Additional detail is provided for the two-mirror customized Cassegrain telescope design <ref type="bibr">[15]</ref>, and experimental investigations were conducted in parallel to the simulations for this system. The remainder of this paper is organized as follows. Section 2 reviews the computational method for the sigma vectors. Section 3 provides the theoretical background of NAT, including third-order aberrations that show nodal behavior in the image plane. The analytical node positions are verified using numerically calculated nodes in Section 4. Section 5 provides paraxial quantities for the customized Cassegrain telescope, calculations of surface aberration coe cients, and a detailed description of the experimental setup. Section 6 presents the results of sigma vector calculations for coma and astigmatism and compares the theory and experiments.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.">Sigma vectors</head><p>In optical systems with rotational symmetry, the OAR, defined as the ray that connects the center of the object plane and the center of the aperture stop, coincides with the Mechanical Axis (MCA), which is used for calculating paraxial and third-order quantities of the optical system. In that case, the OAR also intersects all centers of curvatures and vertices of the surfaces and the center of the image plane. In an optical system with symmetry, the incident angle of the OAR at each surface is always zero; thus, the field displacement vectors are zero.</p><p>With misalignments, the intersection point of the OAR and the image plane becomes a new center of the field. The shift of the MCA from this new field center is called the boresight error. The boresight error for a two-mirror telescope system whose aperture stop is located at the primary mirror is shown in Fig. <ref type="figure">1(a)</ref>. Furthermore, with misalignments, the center of symmetry for a given aberration contribution for a perturbed surface, j, shifts to another point in the local image plane, which will also map to a new aberration center in the final image plane. This field displacement vector is called a sigma vector and is denoted by j <ref type="bibr">[14]</ref> (where bold depicts vector). The sigma vector starts at the intersection point of the OAR and the image plane. In NAT, if a surface is aspheric, two separate sigma vectors have to be calculated, one originating from the spherical base curve and the second one originating from the aspheric departure from the spherical surface <ref type="bibr">[14]</ref>. Therefore, the sigma vector consists of two components: one from the spherical contribution and the other from the aspherical contribution if an asphere is used. Here, a simple conic would fall under an aspherical contribution.</p><p>The spherical contribution of the sigma vector was previously computed by Buchroeder <ref type="bibr">[2]</ref>. He developed a method based on paraxial ray trace equations, accounting for surface tip/tilt parameters. In his method, the OAR is parameterized by u # OAR (inclination angle at the surface) and &#563;# OAR (intersection height at the surface), parameters measured from the MCA. The drawback of this method was that it could not be easily implemented in a commercial design program <ref type="bibr">[14,</ref><ref type="bibr">16]</ref>. Then, the coordinate-independent method of Thompson et al. was developed that allows computing the spherical contribution of the sigma vector based on real-ray trace data. The equation for computing the spherical contribution of the sigma vector of a misaligned surface is given as <ref type="bibr">[14]</ref> </p><p>where the subscript j is used to define a subjected surface, i &#8676; is the angle of incidence of the OAR at the surface, i j is the local angle of incidence of the paraxial chief ray to use for normalization to image height and N j , R j , and S j are all unit vectors with normalized direction cosines of (X, Y, Z), (L, M, N), and (SRL, SRM, SRN), respectively. Note that * denotes parameters related to the OAR. N j is the normal vector of the object/image plane for the unperturbed system, perpendicular to the Z-axis. R j is the normalized direction vector along the incident ray OAR. S j is the vector along the surface normal at the intersection of the OAR and the surface. An example of the N j R j , and S j vectors at a surface were given in Fig. <ref type="figure">1(b</ref>). Note that the N vector is taken to point from the local image point towards the local exit pupil. The aspheric contribution of the sigma vector depends on the intersection height of the OAR relative to the aspherical vertex and is computed by <ref type="bibr">[14]</ref> </p><p>where, v &#8676; is the aspheric vertex departure of the OAR from the MCA, and y j is the chief ray height at the surface. Since NAT is a surface-based theory, the contribution of a specific surface to the net aberration field is distinguishable and identifiable, and we are currently exploring techniques to achieve this goal. NAT applies to both reflective and refractive optical systems. For instance, if a lens is misaligned, that results in both surfaces of that lens being misaligned. Each surface of the lens is treated separately, but the misalignment values of each surface are understandably tied together. The final sigma vector has contributions from each surface of the lens. In addition, asymmetric systems consisting of o -axis components can be analyzed using the same formalism as for rotationally symmetric systems discussed. The di erence is that each component of an asymmetric system would have some purposeful "misalignment" that describes its position in space. Furthermore, some concepts from NAT have been borrowed to explain how non-symmetric optical elements (i.e., freeform) impact the net aberration field, leading to major advances in the design, fabrication, testing, and assembly of freeform systems <ref type="bibr">[17]</ref><ref type="bibr">[18]</ref><ref type="bibr">[19]</ref>. The e ect of the surface figure errors on the aberrations is also explained by NAT successfully <ref type="bibr">[12,</ref><ref type="bibr">20]</ref>, but it is not the focus of this study.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.">Analytical calculations for the third-order node locations</head><p>The general vector form of the wavefront aberration expansion is expressed as</p><p>where H and &#8674; are normalized field and aperture vectors, respectively, and (W klm ) j are the aberration coe cients of the surface j. For an optical system without symmetry, with the inclusion of the sigma vector contribution to the field vector of an unperturbed optical system, we obtain the new field dependency of aberrations as</p><p>where H Aj is the e ective field vector. Rewriting the wave aberration expansion to comprise only third-order aberrations yields</p><p>where W 040 , W 131 , W 222 , W 220, and W 311 are the aberration coe cients that represent third-order spherical aberration, coma, astigmatism, field curvature, and distortion, respectively.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.1.">Coma node location</head><p>In optical systems without symmetry, third-order coma can have up to one node in the image plane. To compute the coma node location, we first sum the sigma vectors of the individual surfaces weighted by the corresponding surface aberration contributions for coma given by <ref type="bibr">[5</ref>]</p><p>where A 131 is an un-normalized vector in the image plane. W 131,j sph and W 131,j asph are spherical and aspherical aberration contributions of surface j, respectively. j sph and j asph are spherical and aspherical sigma vectors contributions of surface j, respectively. If the system-level third-order coma aberration is non-zero, A 131 can be normalized by system-level W 131 as</p><p>The a 131 vector points to the coma node in the normalized field coordinates. The coma node locations for aligned and misaligned states are depicted in Fig. <ref type="figure">2</ref>(a) and Fig. <ref type="figure">2</ref>(b), respectively.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3.2.">Astigmatism nodes locations</head><p>In optical systems without symmetry, third-order astigmatism can have up to two nodes in the image plane. To compute astigmatism node locations, we first sum the sigma vectors of the individual surfaces weighted by the corresponding surface aberration contributions for astigmatism to yield the displacement vector A 222 given as <ref type="bibr">[5]</ref>,</p><p>where W 222,j sph and W 222,j asph are the spherical and aspherical aberration contributions of surface j, respectively. Similarly, we then form another vector B 2 Fig. <ref type="figure">2</ref>. Full Field Displays (FFDs) of the third-order coma (Z 7/8 ) for a Cassegrain telescope and the node locations for (a) an aligned state where a 131 is zero, (b) a misaligned state. <ref type="bibr">[21,</ref><ref type="bibr">22]</ref> of the sigma vectors with themselves in a weighted sum given as [5]</p><p>If we consider the system-level astigmatism for the aligned system, W 222 , to be non-zero, the normalization of the A 222 vector is given as <ref type="bibr">[5]</ref> </p><p>where a 222 is a normalized vector in field coordinates. Similarly, a normalized vector b </p><p>Isolating the astigmatism and field curvature terms from Eq. ( <ref type="formula">5</ref>), referencing the medial focal plane, and integrating Eq. ( <ref type="formula">10</ref>) and Eq. ( <ref type="formula">11</ref>), astigmatism may be expressed as [5]</p><p>This new characteristic field dependence for astigmatism in the optical system can be solved according to the Shack vector product for locations where the astigmatic terms go to zero for H as</p><p>The vectors a 222 , and &#177;ib 222 comprise a vector from the center of the field to the midpoint between two astigmatic nodes and two vectors pointing from the endpoint of the a 222 vector to the two astigmatic nodes, respectively, illustrated in Fig. <ref type="figure">3(b)</ref>, compared to the one centered node for an aligned system shown in Fig. <ref type="figure">3(a)</ref>.</p><p>As noted above and in earlier work <ref type="bibr">[5,</ref><ref type="bibr">11]</ref>, the solutions to Eq. ( <ref type="formula">13</ref>) correspond to the field coordinate location of the astigmatism nodes. In this paper, our goal is to determine these same node locations directly as vector components, which avoid the need for imaginary numbers, thus simplifying the calculations for simulations and experimental data. To compute astigmatism node locations in component form, expressions given in Eq. ( <ref type="formula">13</ref>) will be rewritten by using components of vectors as given below,</p><p>Substituting the above expressions into Eq. ( <ref type="formula">13</ref>), we get,</p><p>To compute the square operation given in round brackets in Eq. ( <ref type="formula">15</ref>), the Shack Vector Product will be used, resulting in</p><p>Subsequently, by setting components placed on the right and the left sides of the equation, we get two equations to solve for x 0 and y 0 ,</p><p>Solving the first equation of Eq. ( <ref type="formula">17</ref>) for x 0 , we obtain,</p><p>Equation ( <ref type="formula">18</ref>) is then substituted into the second equation in Eq. ( <ref type="formula">17</ref>) to get</p><p>Solving Eq. ( <ref type="formula">19</ref>) for y 0 , we get four solutions below as Eq. <ref type="bibr">(20)</ref><ref type="bibr">(21)</ref>. The two solutions in Eq. <ref type="bibr">(21)</ref> always result in imaginary numbers due to |b y | &#63743; q b x 2 + b y 2 , regardless of the sign of b y . Thus, the two solutions corresponding to the two nodes in the astigmatism field are given by Eq. <ref type="bibr">(20)</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="4.">Numerical verification of analytical node calculations</head><p>The analytical calculation for the location of the nodes of third-order coma and astigmatism in Section 3 is verified here using features of commercial ray-tracing software for one, two, and three-mirror systems, each with some misalignment applied to an optical surface. Using a custom MATLAB code to communicate with ray-tracing software, the optical model's relevant parameters required to calculate the node positions are extracted from each system <ref type="bibr">[23]</ref>. Then, the analytical node positions are calculated as described in Section 3. We then use the ray-tracing software to numerically create a Full Field Display (FFD) that shows the orientation and magnitude of an aberration over a prescribed full field-of-view (FFOV). The aberration vs. FFOV data created in the generation of the FFD is used to numerically solve for the location of the aberration nodes.</p><p>The analytical location and the numerical location of each node are then compared to verify the accuracy of the analytical calculation. We demonstrated this process for three systems: a Newtonian telescope, a Cassegrain telescope, and a three-mirror anastigmat. A system drawing and the resulting FFDs for coma and astigmatism are shown in Fig. <ref type="figure">4</ref>. In each FFD, the red circles indicate the analytical nodes and the red crosses indicate the numerically solved nodes.</p><p>There is close agreement between the theory and simulation for all three cases. Note that the decenter and tilt used in the misalignment for the Cassegrain telescope was a coma-free pivot point, also correctly predicted by the theory. It is important to note that since the analytical calculation is only valid for third-order aberrations, optical systems with non-negligible contributions of fifth and higher orders of aberrations are not appropriate to use for numerical verification. The real-ray based FFDs used to generate the numerical data are ordered agnostic and, thus, show all orders of aberrations. System-level specifications for each of the three systems are provided in Appendix A, including the applied misalignments (Table <ref type="table">10</ref>).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="5.">Example application of sigma vectors for a two-mirror telescope</head><p>To further demonstrate the theory's application in Sections 2 and 3, we look at the two-mirror Cassegrain telescope more deeply. The system will be misaligned intentionally. We then compute the node locations analytically and significantly, confirming the findings for the zeros in the aberration fields experimentally.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="5.1.">Cassegrain telescope design</head><p>A &#216;490 mm aperture, F/12.7, high-precision Cassegrain telescope was used for simulations and was fabricated for the experimental investigation of sigma vectors. The Cassegrain telescope comprises a parabolic concave primary mirror, set as the aperture stop in design, and a hyperbolic convex secondary mirror. The telescope is designed to have di raction-limited performance over a &#177; 0.11-degree FFOV. The telescope optical prescription is listed in Table <ref type="table">1</ref>. The design was optimized with a reference wavelength of 632.8 nm, matching the experiment's wavelength. </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="5.2.">Calculations of the third-order aberration coefficients</head><p>This section uses paraxial ray-trace data to calculate the primary and secondary mirrors' thirdorder astigmatism and coma aberration contributions. Using the optical prescription given in Table <ref type="table">1</ref>, the paraxial ray-trace data, which is also used for the sigma vector calculations, is gathered through the ray-tracing software and is given in Table <ref type="table">2</ref>. The third-order aberration coe cients were calculated using this paraxial data (Appendix B, Table <ref type="table">11</ref>, Table <ref type="table">12</ref>, Table <ref type="table">13</ref>, Table <ref type="table">14</ref>) and shown in Table <ref type="table">3</ref>. </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="5.3.">Analytical calculations and simulations</head><p>The misalignments given in Table <ref type="table">4</ref> were introduced into the telescope's secondary mirror, and the relevant quantities were gathered for the sigma vector calculations. The secondary mirror was decentered along the X-axis and Y-axis and tilted around the X-axis and Y-axis. The spherical contributions of the surfaces' sigma vectors were calculated by Eq. ( <ref type="formula">1</ref>). The direction cosines of the N, R, and S vectors were obtained by NASA Toolkit functions <ref type="bibr">[24]</ref>. The computation results are given in Table <ref type="table">5</ref>. The parameters used to compute the aspherical contributions of the sigma vector are shown in Table <ref type="table">6</ref>. </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="5.4.">Experimental setup</head><p>The auto-collimation experimental setup consists of the Cassegrain telescope, a reference flat mirror, and an interferometer, as demonstrated in Fig. <ref type="figure">5</ref>(a). A Fizeau phase-shifting interferometer with an F/10.7 transmission sphere is confocal to the telescope. The &#216;800 mm aperture reference flat mirror with a motorized tip/tilt stage reflects the output light beam from the telescope.</p><p>The interferometer is placed on a five-axis manual stage that is used to align the focus of the interferometer onto each field point in the image plane. To align the secondary mirror, the telescope uses a customized, piezo-actuated, five-axis flexure mechanism. This mechanism is also used for introducing the misalignments into the telescope for this work. A schematic diagram of the experimental setup for the field measurements is shown in Fig. <ref type="figure">5(b)</ref>. </p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="5.5.">Experimental results and discussion</head><p>The misalignments given in Table <ref type="table">4</ref> were introduced into the Cassegrain telescope for generating the aberrations. Then, the wavefront error (WFE) measurements were performed interferometrically on a 5 &#8677; 5 grid of field points, given in Table <ref type="table">7</ref>. The results of the raw interferometric measurement data (piston, tip/tilt are removed from the data) are presented in Fig. <ref type="figure">6</ref>. In Fig. <ref type="figure">6</ref>, interferometric data for the corner points were not accurate because of the inner diameter dimension limit of the primary mirror that caused obscuration for the interferometer beam. Therefore, the corner points were excluded from the calculations. In the next step, the third-order astigmatism (Z 5/6 ) and coma (Z 7/8 ) terms were extracted from the WFE data where Z 5/6 and Z 7/8 designate Zernike Fringe coe cients. The magnitudes of the third-order astigmatism and coma terms were calculated by Z 5/6 = q Z 2 5 + Z 2 6 and </p><p>, respectively. The simulated and experimental interferograms are illustrated in Fig. <ref type="figure">7</ref>. As seen in Fig. <ref type="figure">7</ref>(a), one of the third-order astigmatism nodes is located near the center of the FOV, and the second one is located close to the field point (-0.125, 0.250). As seen in Fig. <ref type="figure">7</ref>(b), the third-order coma node is located between the field points (0.125, 0.250) and (0.125, 0.125). The interferograms obtained experimentally were also compared to the simulated interferograms in Fig. <ref type="figure">7(c</ref>) and Fig. <ref type="figure">7(d</ref>) to verify the specific aberrational behavior of third-order astigmatism and coma along the FOV. The node locations were found by fitting the related Zernike Fringe coe cients, measured from field rows and columns around the nodes, to the appropriate polynomials concerning the field dependencies of the aberrations. The coma node location was directly determined as a result of the polynomial fitting process as the endpoint of the a 131 &#8677; HFOV vector where HFOV designates half field of view (i.e., 0.25-deg). The calculation of the components of the a 222 &#8677; HFOV vector was performed by taking the midpoint of the astigmatism nodes. The results are given in Table <ref type="table">8</ref>. After obtaining the a 222 and a 131 aberration field vectors experimentally, Eq. ( <ref type="formula">9</ref>), and Eq. ( <ref type="formula">13</ref>) were used to compute the sigma vectors contribution variables. Four equations were used to solve for sph SM,x , sph SM,y , asph SM,x , and asph SM,y . Then, the components of the sigma vector contributions were computed as given in Table <ref type="table">9</ref>. The experimental results are consistent with the computed analytical results presented in Table <ref type="table">9</ref> within 1.63%. Hence, the experimental results validate the simulations and the analytical calculations predicted by NAT. To investigate the environmental e ects such as air turbulence, vibration, and temperature on the stability of the interferometric measurements, a statistical analysis of the measurements was also carried out by performing multiple measurements on a single field point. In Fig. <ref type="figure">8</ref>, nine measurements obtained from the field point [0.125, -0.250] are presented for three parameters of Z 5/6 , Z 7/8 , and RMS WFE. In Fig. <ref type="figure">8</ref>(a), the amplitudes of measurements are depicted, and in Fig. <ref type="figure">8</ref>(b), deviations from the average value for each measurement are demonstrated. The standard deviations for the Z 5/6 , Z 7/8 , and WFE (RMS) parameters are calculated to be 0.0058 , 0.0029 , and 0.0022 , respectively, which points to the extreme stability of the experimental setup.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="6.">Conclusion</head><p>In this work, we presented calculations for computing the sigma vectors in NAT, verified those calculations for one-, two-, and three-mirror telescopes, and experimentally validated the findings for a two-mirror telescope. The analytical calculations for a general optical system were presented in the first step. The sigma vectors for three misaligned telescopes were introduced in the second step using the given mathematical background simulations and analytical calculations. The simulations were validated experimentally on the Cassegrain telescope, whose secondary mirror was intentionally misaligned in the equivalent amount as presented in the simulations. In experiments, interferometric wavefront measurements were performed on twenty-one field points, and third-order astigmatism and coma were extracted from data to find the locations of the nodes. The sigma vectors were calculated experimentally after locating the nodes in the image plane. The simulations and analytical calculations agreed to within 1.63%, which validates the calculation of the sigma vectors in NAT for the first time.</p><p>The accuracy of the measurements was also checked by employing statistical analysis that confirmed that environmental e ects did not limit the measurements. The primary source of error was the manual positioning of locating the interferometer focus on the field points. The study showed that sigma vectors in NAT are a powerful tool for the alignment of complex modern telescope systems as they can facilitate and expedite the telescope alignment. Generally, these telescope systems have large image planes. Field dependency-based di raction-limited telescope alignment over the full image plane can be achieved by sigma vectors in a fast and accurate way. The investigation and experimentation of the inverse problem of utilizing the sigma vector for telescope alignment in a deterministic computer-aided procedure is an ongoing study and future standalone contribution. For future studies, new small-size interferometers with motorized stages can greatly expedite the whole measurement time. Moreover, point spread function (PSF) decomposition may be additionally used with a suitable experimental setup, extending the potential applications, such as measuring the telescope's image quality.</p><p>Appendix A: specifications for the systems used for verification in Section 4. </p></div></body>
		</text>
</TEI>
