<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Exploring fibroblast interactions on nanocrystalline surfaces in physiological environments through a phenomenological lens</title></titleStmt>
			<publicationStmt>
				<publisher>Taylor and Francis</publisher>
				<date>12/31/2024</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10506619</idno>
					<idno type="doi">10.1080/21691401.2024.2338127</idno>
					<title level='j'>Artificial Cells, Nanomedicine, and Biotechnology</title>
<idno>2169-1401</idno>
<biblScope unit="volume">52</biblScope>
<biblScope unit="issue">1</biblScope>					

					<author>RDK Misra</author><author>Aladin M. Boriek</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[F u l l T e rm s & C o n d i t i o n s o f a c c e s s a n d u s e c a n b e f o u n d a t h t t p s : / /www . t a n d f o n l i n e . c om / a c t i o n / j o u r n a l I n f o rm a t i o n ? j o u r n a l C o d e = i a n b 2 0 A r t i f i c i a l C e l l s , N a n om e d i c i n e , a n d B i o t e c h n o l o g y A n I n t e r n a t i o n a l J o u r n a l I S SN : ( P r i n t ) (O n l i n e ) J o u r n a l h om e p a g e : www . t a n d f o n l i n e . c om / j o u r n a l s / i a n b 2 0 E x p l o r i n g f i b r o b l a s t i n t e r a c t i o n s o n n a n o c r y s t a l l i n e s u r f a c e s i n p h y s i o l o g i c a l e n v i r o nm e n t s t h r o u g h a p h e n om e n o l o g i c a l l e n s R .D . K M i s r a & A l a d i n M . B o r i e k T o c i t e t h i s a r t i c l e : R .D . K M i s r a & A l a d i n M . B o r i e k ( 2 0 2 4 ) E x p l o r i n g f i b r o b l a s t i n t e r a c t i o n s o n n a n o c r y s t a l l i n e s u r f a c e s i n p h y s i o l o g i c a l e n v i r o nm e n t s t h r o u g h a p h e n om e n o l o g i c a l l e n s , A r t i f i c i a l C e l l s , N a n om e d i c i n e , a n d B i o t e c h n o l o g y , 5 2 : 1 , 2 2 9 -2 3 7 , DO I :]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head>HIGHLIGHT POINTS</head><p>The significance of nanoscale surface in favourably modulating the cellular functionality is described with the aim to provide the solution to the current day challenges in the biomedical arena. Furthermore, the perspective presented advances the nano-bio science forward by implying that the nanoscale structure induces chemical and physical changes that can be considered responsible for favourable modulation of cellular activity in the living organism.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Fabrication and characterization of nanocrystalline surfaces to investigate fibroblast interactions</head><p>Titanium alloys and austenitic stainless steels are predominantly used for the fabrication of biomedical devices <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[4]</ref><ref type="bibr">[5]</ref>. In some instances, biomedical devices exhibit premature failure, which is generally a consequence of inadequate build-up of tissue around the device. This leads to loosening of the biomedical device and is further facilitated by diminished cell-surface interactions. Additionally, factors such as wear and generated debris also contribute significantly to biomedical device failure. This impacts the immune response of the physiological system, which leads to inflammation, necrosis, and the loss of bone surrounding the implant <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[4]</ref><ref type="bibr">[5]</ref>. Keeping this in mind, the nanocrystalline biomedical device system is a promising and viable approach for fabrication of futuristic biomedical devices <ref type="bibr">[4]</ref>. This aspect is illustrated below, where the cytological interactions on NC surfaces are observed, which facilitate tissue growth and mineralization. Moreover, the enhanced strength associated with NC materials serves as an advantage, facilitating enhanced wear resistance and reduced device weight since a thinner biomedical device would meet requisite specifications <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[4]</ref><ref type="bibr">[5]</ref>.</p><p>To obtain nanocrystalline and ultrafine-crystalline structures, methods such as heat treatment <ref type="bibr">[4]</ref><ref type="bibr">[5]</ref><ref type="bibr">[6]</ref>, powder metallurgy <ref type="bibr">[7]</ref>, and sintering <ref type="bibr">[8,</ref><ref type="bibr">9]</ref> have been adopted, which modulate cytological functions and extend the operational lifespan of medical devices <ref type="bibr">[8]</ref><ref type="bibr">[9]</ref><ref type="bibr">[10]</ref><ref type="bibr">[11]</ref><ref type="bibr">[12]</ref><ref type="bibr">[13]</ref><ref type="bibr">[14]</ref><ref type="bibr">[15]</ref>. While laboratory-scale severe plastic deformation methods such as equal channel angular pressing (ECAP) <ref type="bibr">[15]</ref><ref type="bibr">[16]</ref><ref type="bibr">[17]</ref><ref type="bibr">[18]</ref>, accumulative roll bonding (ARB) <ref type="bibr">[19]</ref><ref type="bibr">[20]</ref><ref type="bibr">[21]</ref>, high-pressure torsion (HPT) <ref type="bibr">[22]</ref><ref type="bibr">[23]</ref><ref type="bibr">[24]</ref><ref type="bibr">[25]</ref>, multiple compression <ref type="bibr">[26]</ref>, and upsetting extrusion <ref type="bibr">[27]</ref> have shown success, they often compromise ductility, a crucial factor for biomedical device fabrication. A high strength-high ductility combination is necessary for a prolonged lifespan in any metallic device <ref type="bibr">[28]</ref><ref type="bibr">[29]</ref><ref type="bibr">[30]</ref><ref type="bibr">[31]</ref>. To address this necessity, Misra's group developed an ingenious concept of phase reversion with a specific focus on stainless steel to achieve a nanocrystalline structure within the bulk alloy <ref type="bibr">[32]</ref><ref type="bibr">[33]</ref><ref type="bibr">[34]</ref>. This concept involves cold-reducing stainless steel by approximately &#8764;60-80%, inducing a phase transformation from face-centred austenite to body-centred martensite. Subsequent short-term Biomedical stainless steel; nanocrystalline; crystal boundary attributes; biological functionality heat treatment at higher temperatures of 700-800 &#176;C for short durations of 10-100 s reverts the martensite phase to austenite <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[32]</ref><ref type="bibr">[33]</ref><ref type="bibr">[34]</ref>. Notably, the resultant crystalline structure is influenced by the degree of cold deformation and the specifics of temperature-time heat treatment. Figure <ref type="figure">1</ref> illustrates a comparative analysis between the nanocrystalline structure and conventional microcrystalline structures. The nanocrystalline structure, achieved through the phase reversion process, remarkably preserves ductility while enhancing strength, defining a paradigm of high strength-high ductility combination within nanocrystalline stainless steel <ref type="bibr">[33]</ref>. This augmented strength not only contributes to wear resistance but also extends the material's lifespan, while the retained ductility holds promise for biomedical device fabrication <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[32]</ref><ref type="bibr">[33]</ref><ref type="bibr">[34]</ref>.</p><p>The primary aim of this study is to elucidate fundamental insights into the distinctive characteristics of nanocrystalline surfaces, characterized by crystal sizes within the nanoscale range and crystal boundaries exceeding 50%. We aim to compare these characteristics with those of microcrystalline surfaces, characterized by crystal sizes in the microscale range with approximately &#8764;2-3% crystal boundaries. We hypothesize that these differences play a key role in enhancing the adhesion of fibroblast cells to the NC surface, leading to enhanced cellular spreading, synthesis of key proteins, and mineralisation processes. In this regard, we initially provide an overview by summarising the findings from prior studies on the cytological functions such as cell adhesion, proliferation, protein synthesis, mineralisation, and cell differentiation on both NC and MC surfaces. This is followed by a discussion of our viewpoints regarding the relationship between the chemical and physical attributes of these surfaces and their potential impact on cellular functions. We postulate that these attributes significantly influence the observed differences in cellular activities between the NC and MC surfaces. This investigation seeks to uncover the relationship between surface properties and cellular behaviours, ultimately providing valuable insights into the molecular mechanisms governing biological functions. The understanding of these physical and chemical attributes is expected to provide a strong rationale for further mechanistic studies, the results of which will be reported in subsequent reports.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Experimental methodology to study cellular interactions between the nanoscale surface and the biological environment</head><p>The phase reversion concept enables varying crystal size to be obtained in the bulk alloy <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[32]</ref><ref type="bibr">[33]</ref><ref type="bibr">[34]</ref>. The data in Figure <ref type="figure">1</ref> demonstrate the relationship between nanocrystalline size, determined by varying cold reduction percentages and temperature heat treatments, and corresponding strength and mechanical percent elongation. This is contrasted with the characteristics of the microcrystalline counterpart. Multiple micrographs were used to derive the average crystal size, while the mechanical properties were assessed following the guidelines set by the ASTM standard. The average crystal size of MC steel was 22 &#177; 3 &#956;m with a yield strength of 350 &#177; 5 MPa and elongation of &#8764;40%. On the contrary, the nanocrystalline steel was characterized by average crystal size of 90 &#177; 8 nm, yielding a strength of 800 &#177; 7 MPa and elongation of &#8764;38%. These properties exhibit exceptional performance for bulk nanocrystalline stainless steel <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[32]</ref><ref type="bibr">[33]</ref><ref type="bibr">[34]</ref>.</p><p>Here, we provide a concise overview of the experimental protocol employed to explore biological functions and surface interactions with cells. A comprehensive and detailed description can be found elsewhere <ref type="bibr">[35]</ref><ref type="bibr">[36]</ref><ref type="bibr">[37]</ref><ref type="bibr">[38]</ref><ref type="bibr">[39]</ref><ref type="bibr">[40]</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Preparation of nanocrystalline and microcrystalline surfaces</head><p>Recognising the substantial impact of surface roughness on cell adhesion, we carefully ensured that the surfaces under investigation for cellular functions exhibited near atomic-scale roughness. This was achieved by sequentially polishing the surface using various grades of SiC paper, resulting in a final polish using colloidal silica in water. The average arithmetic mean roughness (Ra), measured across a 3 &#956;m &#215; 3 &#956;m scan area, was found to be 1.45 &#177; 0.21 nm for MC stainless steel and 1.52 &#177; 0.29 nm for NC stainless steel <ref type="bibr">[35]</ref><ref type="bibr">[36]</ref><ref type="bibr">[37]</ref><ref type="bibr">[38]</ref><ref type="bibr">[39]</ref><ref type="bibr">[40]</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Cell culture</head><p>The study utilized a mouse fibroblast cell line (l-cell-l929 ATCC, USA) to investigate cytological functions on NC and MC surfaces. These fibroblasts were cultured in Eagle's minimum essential medium (Invitrogen Corporation, USA) supplemented with 10% horse serum, penicillin (100 U ml -1 ), and streptomycin (100 &#181;g ml -1 ). The surfaces were prepared by mechanically polishing them to achieve nanometric roughness and sizing them to 1 cm 2 . Following cleaning in an ultrasonic bath with ethanol and deionized water, each surface was individually wrapped in gauze and sterilized in an autoclave. Fibroblasts at 80-85% confluence, derived from T-flask cultures through trypsinization, were used to seed onto the polished samples <ref type="bibr">[3,</ref><ref type="bibr">37,</ref><ref type="bibr">40]</ref>. Fibroblast cells were washed with phosphate-buffered saline (PBS), then incubated with 0.25% trypsin/0.53 mM EDTA for 5-7 min to detach them from the Petri dish. After dispersion in trypsin/ EDTA, cells were transferred to a centrifuge tube and spun at 2000 rpm for 5 min. The resulting cell pellet was re-suspended in a culture medium and appropriately diluted to obtain the required cell concentration. Following this preparation, sterilized steel discs were placed in a 24-well plate and incubated with the cell suspension at 37 &#176;C in a humidified atmosphere containing 5% CO 2 and 95% air. For control experiments, polystyrene 24-well culture plates were used <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[35]</ref><ref type="bibr">[36]</ref><ref type="bibr">[37]</ref><ref type="bibr">[38]</ref><ref type="bibr">[39]</ref><ref type="bibr">[40]</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Adhesion of fibroblasts</head><p>The adhesion and density of fibroblasts on NC and MC surfaces were assessed using fluorescent labelling of nucleic acids with a fluorescence microscope (Nikon E600). Fibroblasts (10,000 cells/cm 2 ) were seeded on NC and MC surfaces and left at 37 &#176;C in an incubator with 5% CO 2 and 95% air for varying durations. Following incubation, the fibroblasts were stained with the nucleic acid dye (Hoechst 33342). The discs containing the seeded cells were washed twice with PBS and then incubated in a solution of 10 &#181;g dye/ml PBS at 25 &#176;C for 10 min before observation under a fluorescence microscope with excitation and emission wavelengths of 346/442 nm, respectively <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[35]</ref><ref type="bibr">[36]</ref><ref type="bibr">[37]</ref><ref type="bibr">[38]</ref><ref type="bibr">[39]</ref><ref type="bibr">[40]</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Response of fibroblasts to MC and NC surfaces</head><p>The adhesion and cell density of fibroblasts differed significantly between the NC and MC surfaces (Figure <ref type="figure">2</ref>). Fibroblasts showed notably higher adherence and cell density on the NC surface compared to the MC surface. This trend was consistent with increased metabolic activity observed via mitochondrial reduction in the MTT assay, indicating superior cytocompatibility of the NC surface. Fluorescence micrographs of fibroblasts stained with nucleic acid-specific dye supported this finding (Figure <ref type="figure">2</ref>) <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">[35]</ref><ref type="bibr">[36]</ref><ref type="bibr">[37]</ref><ref type="bibr">[38]</ref><ref type="bibr">[39]</ref><ref type="bibr">[40]</ref>. The variations in fibroblast adhesion density between the NC and MC surfaces were not attributed to cell development or surface adaptation over time <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">37,</ref><ref type="bibr">40]</ref>.</p><p>Interestingly, SEM images revealed distinct differences in fibroblast morphology (Figure <ref type="figure">3</ref>). On the NC surface, fibroblasts displayed widespread cellular with a star-like morphology after approximately 24 h of cell culture. In contrast, while spreading occurred on the MC surface, it was less extensive compared to the NC surface. Overall, fibroblasts exhibited greater spreading on the NC surface, indicating a preferable interaction compared to the MC surface <ref type="bibr">[1]</ref><ref type="bibr">[2]</ref><ref type="bibr">[3]</ref><ref type="bibr">37,</ref><ref type="bibr">40]</ref>.</p><p>The synthesis and expression of key proteins (fibronectin, actin, and vinculin) on both surfaces provided further insights into fibroblast interaction. The observations (Figures <ref type="figure">2</ref><ref type="figure">3</ref><ref type="figure">4</ref><ref type="figure">5</ref><ref type="figure">6</ref><ref type="figure">7</ref>) confirmed that the NC surface favoured interaction with surrounding cells, leading to some clumping of fibroblasts <ref type="bibr">[3,</ref><ref type="bibr">37,</ref><ref type="bibr">40]</ref>.</p><p>Confocal microscopy combining cytoskeletal elements and the nucleus (Figure <ref type="figure">7</ref>) highlighted stronger expression levels of vinculin focal contacts and actin stress fibres on the NC surface compared to the MC surface. This indicated a more intense interaction of fibroblasts with the NC surface in the cellular environment <ref type="bibr">[3,</ref><ref type="bibr">37,</ref><ref type="bibr">40]</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Biophysical attributes and the relationship with the interaction of fibroblasts with NC and MC surfaces</head><p>To understand the contrasting cytological functions of NC and MC surfaces, we begin by defining a key biophysical parameter: the average crystal boundary length per surface area. Analysing several micrographs in Figure <ref type="figure">1</ref> revealed this parameter to be approximately &#8764;15.5 &#181;m/&#181;m 2 for NC and &#8764;0.14 &#181;m/&#181;m 2 for MC surfaces. Next, considering the typical width (&#8764;10-20 &#181;m) and length (&#8764;80-100 &#181;m) of fibroblasts, we observe that on the NC surface, a fibroblast cell spans approximately 100-200 crystals in width and 900-1000 crystals in length. Conversely, on the MC surface, a fibroblast extends across only a few crystals in width and approximately 10-15 crystals in length. In brief, the NC surface, rich in crystal boundaries (&gt;50%), accommodates a significantly larger area covered by fibroblasts (1612 &#181;m 2 ) compared to the MC surface (984 &#181;m 2 ). To clarify these findings, we combined an important bio-physical parameter <ref type="bibr">[41]</ref>-average crystal boundary/cell-with the cellular functionality, i.e. the average area of NC or MC surface covered by fibroblasts. This combination provided the average crystal boundary length per cell. Table <ref type="table">1</ref> summarizes these biophysical parameters and establishes a relationship between these characteristics and the interaction of surfaces with fibroblasts. The table clearly indicates that the average length of crystal boundary/cell occupied by fibroblasts on the NC surface is considerably greater than that on the MC surface. Remarkably, the average intercept length of &#8764; 50 nm of the NC surface mirrors the average separation distance of endothelial cells (&#8764;40 nm) <ref type="bibr">[42]</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>The relevance of NC surface in the context of cellular interactions</head><p>The findings summarised above suggest a clear preference for the NC surface in promoting fibroblast adhesion, proliferation, and key protein synthesis (fibronectin, actin, vinculin) when compared to the MC surface. This preference holds true for similar roughness and an identical microstructural constituent (i.e. austenite phase). This leads us to enunciate that the observed differences in cellular interaction on the NC and MC surfaces stem from disparities in their physical and chemical characteristics. Notably, factors like surface energy, electron work function, surface charge density, and the physical and chemical attributes of crystal boundaries discussed above contribute to these differences. Understanding these distinctions is crucial in customizing the biological functionality of biomedical devices.     Our ongoing study investigates the physical and chemical characteristics of biomedical surfaces concerning crystal size. This exploration aims to unravel the molecular mechanisms dictating fibroblast interaction across various crystalline surfaces. Central to our investigation is unravelling how a surface's physical and chemical attributes influence cellular functionality. Clarifying and revealing the mechanism by which the NC surface promotes biological processes such as adhesion, proliferation, and protein synthesis holds the potential for a transformative understanding that could significantly impact the tailoring of surface functionality in biomedical devices.</p><p>The insights mentioned above will significantly advance nano-bio science forward by unravelling the understanding of how nanoscale structures induce chemical and physical changes that are responsible for favourable modulation of cellular activity within living organisms. The discovery that nanostructures can enhance cell adhesion through these physical and chemical changes without introducing additional chemical functionalities on the surface represents a significant advancement beyond guiding the customization of cellular functionality at the bio-nano surface.</p><p>Ongoing studies into the physical and chemical attributes hold potential for several contributions: (i) Revealing a mechanism explaining how the NC surface induces changes in surface chemistry, surface energy, and electron work functions, thereby impacting cellular functionality. (ii) Elucidating mechanisms involving measurable changes in the crystal boundary state/energy caused by the NC surface compared to the MC surface, and how these changes influence cell adhesion and biological functionality. (iii) Uncovering the mechanism guided by the relationship between the high density of crystal boundaries with high crystal boundary energy and the electronic properties of the NC surface. This exploration aims to enhance our fundamental understanding of how this relationship contributes to the high cell adhesion ability of the NC surface. (iv) Elucidating the relationship between the adhesive force or adhesion energy of the NC surface and its electronic properties, providing a foundational understanding of how this mechanism regulates cell adhesion.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>Potential long-term outcomes and benefits to the biomedical field</head><p>Understanding the interaction between cells and surfaces can aid in developing surfaces capable of exhibiting specific physical and chemical properties. These surfaces could potentially facilitate targeted biological responses that are critical for optimizing the design of biomedical devices. This understanding can be directly applied to various metallic (like Ti-and Co-based alloys) and non-metallic systems (including ceramics and polymer nanocomposites). This shared structure-property relationship influences osseointegration and the replacement or reconstruction of hard tissues. Biomedical alloys like Ti and Co can undergo severe plastic deformation (e.g. high-pressure torsion) in a manner like the phase reversion concept to attain a NC structure. Exploring how nano-structuring affects cellular functions could significantly advance tissue engineering.</p><p>Understanding cell-surface interactions is vital for nanoscale substrate patterning and potentially innovating new biological electromechanics and microfluidic systems at the nanotechnology level. For example, integrating NC elements into microfluidic devices has the potential to broaden their applications to include cell differentiation, sorting, and selective staining. In addition, optimizing the processing of NC implants to modulate biological functionality and enhance wear resistance could enable the customization of surface properties. This customisation could influence cellular behaviours by promoting optimal responses from surrounding tissues, thus enhancing implant functionality. </p></div></body>