<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>The two-photon exchange experiment at DESY</title></titleStmt>
			<publicationStmt>
				<publisher>https://link.springer.com/</publisher>
				<date>04/01/2024</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10511515</idno>
					<idno type="doi">10.1140/epja/s10050-024-01299-2</idno>
					<title level='j'>The European Physical Journal A</title>
<idno>1434-601X</idno>
<biblScope unit="volume">60</biblScope>
<biblScope unit="issue">4</biblScope>					

					<author>R Alarcon</author><author>R Beck</author><author>J C Bernauer</author><author>M Broering</author><author>A Christopher</author><author>E W Cline</author><author>S Dhital</author><author>B Dongwi</author><author>I Fernando</author><author>M Finger</author><author>M Finger</author><author>I Friščić</author><author>T Gautam</author><author>G N Grauvogel</author><author>D K Hasell</author><author>O Hen</author><author>T Horn</author><author>E Ihloff</author><author>R Johnston</author><author>J Kelsey</author><author>M Kohl</author><author>T Kutz</author><author>I Lavrukhin</author><author>S Lee</author><author>W Lorenzon</author><author>S Lunkenheimer</author><author>F Maas</author><author>R G Milner</author><author>P Moran</author><author>J Nazeer</author><author>T Patel</author><author>M Rathnayake</author><author>R Raymond</author><author>R P Redwine</author><author>A Schmidt</author><author>U Schneekloth</author><author>D Sokhan</author><author>M Suresh</author><author>C Vidal</author><author>Z Yang</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[<title>Abstract</title> <p>We propose a new measurement of the ratio of positron-proton to electron-proton elastic scattering at DESY. The purpose is to determine the contributions beyond single-photon exchange, which are essential for the Quantum Electrodynamic (QED) description of the most fundamental process in hadronic physics. By utilizing a 20cm long liquid hydrogen target in conjunction with the extracted beam from the DESY synchrotron, we can achieve an average luminosity of<inline-formula><alternatives><tex-math>$$2.12\times 10^{35}$$</tex-math><math><mrow><mn>2.12</mn><mo>×</mo><msup><mn>10</mn><mn>35</mn></msup></mrow></math></alternatives></inline-formula>cm<inline-formula><alternatives><tex-math>$$^{-2}\cdot $$</tex-math><math><mrow><msup><mrow/><mrow><mo>-</mo><mn>2</mn></mrow></msup><mo>·</mo></mrow></math></alternatives></inline-formula>s<inline-formula><alternatives><tex-math>$$^{-1}$$</tex-math><math><msup><mrow/><mrow><mo>-</mo><mn>1</mn></mrow></msup></math></alternatives></inline-formula>(<inline-formula><alternatives><tex-math>$$\approx 200$$</tex-math><math><mrow><mo>≈</mo><mn>200</mn></mrow></math></alternatives></inline-formula>times the luminosity achieved by OLYMPUS). The proposed two-photon exchange experiment (TPEX) entails a commissioning run at a beam energy of 2GeV, followed by measurements at 3GeV, thereby providing new data up to<inline-formula><alternatives><tex-math>$$Q^2=4.6$$</tex-math><math><mrow><msup><mi>Q</mi><mn>2</mn></msup><mo>=</mo><mn>4.6</mn></mrow></math></alternatives></inline-formula>(GeV/<italic>c</italic>)<inline-formula><alternatives><tex-math>$$^2$$</tex-math><math><msup><mrow/><mn>2</mn></msup></math></alternatives></inline-formula>(twice the range of current measurements). We present and discuss the proposed experimental setup, run plan, and expectations.</p>]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="1">Introduction</head><p>Elastic lepton-proton scattering is a fundamental process that allows us to study the structure of the proton. It is described a e-mail: ewcline@mit.edu (corresponding author) b e-mail: ievgen@umich.edu (corresponding author) theoretically in the Standard Model by a perturbative expansion in &#945; &#8776; 1  137 with terms beyond leading order commonly called radiative corrections. Calculating such radiative corrections have been extensively described in the paper by Mo and Tsai <ref type="bibr">[1]</ref>, which also stressed the importance of electronproton and positron-proton elastic scattering experiments, and subsequent work by Maximon and Tjon <ref type="bibr">[2]</ref>, and others.</p><p>In the Born or single photon exchange approximation the elastic e &#177; p scattering cross section is given by the reduced Rosenbluth cross section,</p><p>where &#964; = Q 2 , was found to be close to unity over a broad range in Q 2 (shown by the blue data points in Fig. <ref type="figure">1</ref>) leading to the proton form factors being envisaged as very similar and often modeled by the same dipole form factor.</p><p>However, recent measurements using polarization techniques revealed a completely different picture with the ratio Fig. <ref type="figure">1</ref> Proton form factor ratio measured using unpolarized <ref type="bibr">[3]</ref><ref type="bibr">[4]</ref><ref type="bibr">[5]</ref><ref type="bibr">[6]</ref><ref type="bibr">[7]</ref><ref type="bibr">[8]</ref><ref type="bibr">[9]</ref><ref type="bibr">[10]</ref> (blue) and polarized <ref type="bibr">[11]</ref><ref type="bibr">[12]</ref><ref type="bibr">[13]</ref><ref type="bibr">[14]</ref><ref type="bibr">[15]</ref><ref type="bibr">[16]</ref><ref type="bibr">[17]</ref><ref type="bibr">[18]</ref> (red) techniques Fig. <ref type="figure">2</ref> Feynman diagrams for one-and two-photon exchange. Further diagrams for bremsstrahlung, vertex, self-energy, and vacuum polarization radiative corrections are not shown but must also be included in calculations decreasing rapidly with increasing Q 2 as shown by the red data points in Fig. <ref type="figure">1</ref>.</p><p>The most commonly proposed explanation for this discrepancy is "hard" two-photon exchange contributions beyond the standard radiative corrections to one-photon exchange <ref type="bibr">[19]</ref>. Two-photon exchange, TPE, (see Fig. <ref type="figure">2</ref>) is generally included as part of the radiative corrections when analyzing electronproton scattering.</p><p>However, it is usually only included in the "soft" limit where one of the two photons, in the diagrams with two photons, is assumed to carry negligible momentum and the intermediate hadronic state remains a proton. To include "hard" two-photon exchange, a model for the off-shell, intermediate hadronic state must also be included, making the calculations difficult and model dependent.</p><p>Recent experiments, including the OLYMPUS experiment at DESY, show little evidence for significant contributions beyond single photon exchange up to Q 2 &#8776; 2.3 (GeV/c) 2 . To determine if "hard" two-photon exchange contributions can explain the form factor discrepancy new measurements at higher Q 2 are necessary. Fig. 4 OLYMPUS results for R 2&#947; as a function of . Inner error bars are statistical while the outer error bars include uncorrelated systematic uncertainties added in quadrature. The gray band represents the correlated systematic uncertainty</p><p>To measure the "hard" two-photon contribution, one can measure the ratio R 2&#947; = &#963; e + p /&#963; e -p at different values of Q 2 and . Following the Feynmann rules to calculate the cross sections, &#963; e &#177; p , one squares the matrix elements. Using just the first two diagrams shown in Fig. <ref type="figure">2</ref> as an illustrative example one gets:</p><p>Note the interference term between one-and two-photon exchange diagrams (shown in Fig. <ref type="figure">3</ref>) has an odd number of lepton vertices. This means it will change sign between electron and positron scattering and can provide a measure of the two-photon exchange contribution.</p><p>The results from the OLYMPUS experiment <ref type="bibr">[20]</ref> are shown in Fig. <ref type="figure">4</ref> together with various calculations.</p><p>The deviation of the results from unity are small, on the order of 1%, and are below unity at large and rising with decreasing . The dispersive calculations of Blunden <ref type="bibr">[21]</ref> are systematically above the OLYMPUS results in this energy regime. The phenomenological prediction from Bernauer <ref type="bibr">[22]</ref> and the subtractive dispersion calculation from Tomalak <ref type="bibr">[23]</ref> are in better agreement with the OLYMPUS results but appear to rise too quickly as decreases. There is some indication that TPE increases with decreasing or increasing Q 2 , suggesting that a significant "hard" two-photon contribution might be present at lower or higher Q 2 .</p><p>Two other experiments, VEPP-3 <ref type="bibr">[24]</ref> and CLAS <ref type="bibr">[25]</ref>, also measured the "hard" two-photon exchange contribution to electron-proton elastic scattering. It is difficult to compare the results from the three experiments directly since the measurements are at different points in the ( , Q 2 ) plane. To partially account for this, we can compare all the two-photon exchange results by taking the difference with respect to a selected calculation evaluated at the correct ( , Q 2 ) for each data point. This is shown in Fig. <ref type="figure">5a</ref> for Blunden's calculation and in Fig. <ref type="figure">5b</ref> for Bernauer's phenomenological prediction, plotted versus Q 2 . In these views, the results from the three experiments are shown to be in reasonable agreement supporting the previous conclusions.</p><p>The results from the three TPE experiments are all below Q 2 = 2.3 (GeV/c) 2 . In this regime the discrepancy in the form factor ratios is not obvious, so the small "hard" TPE contribution measured is consistent with the measured form factor ratios. The increase in R 2&#947; with decreasing in Fig. <ref type="figure">4</ref> suggests that TPE may be important at smaller or higher Q 2 . But, since this slope appears to deviate from Bernauer's phenomenological prediction, which fits the observed discrepancy, it may also suggest that "hard" TPE, while contributing, may not explain all of the observed form factor discrepancy.</p><p>Fig. <ref type="bibr">6</ref> The charge-averaged yield for elastic lepton-proton scattering from the OLYMPUS experiment <ref type="bibr">[26]</ref> Fig. <ref type="figure">7</ref> More general electroweak box diagram (where V = Z 0 , W &#177; , or &#947; ) that is important in many fundamental nuclear physics processes Recently, the OLYMPUS data has also been analyzed to determine the charge-averaged yield for elastic lepton-proton scattering <ref type="bibr">[26]</ref>. The result is shown in Fig. <ref type="figure">6</ref>.</p><p>This measurement is insensitive to any charge-odd radiative corrections including "hard" two-photon exchange and thus provides a better measure of the proton form factors. The data shown covers an important range of Q 2 where the G M form factor changes slope. The calculations by Kelly <ref type="bibr">[27]</ref> and Arrington <ref type="bibr">[28,</ref><ref type="bibr">29]</ref> appear to be in better agreement with the data, but Bernauer's global fit <ref type="bibr">[22]</ref> should be redone to incorporate all the OLYMPUS data.</p><p>The two-photon exchange diagram in the QED expansion for electron scattering is an example of the more generic electroweak photon-boson diagram (see Fig. <ref type="figure">7</ref>) which enters into a number of fundamental processes in subatomic physics. The &#947; -Z box is a significant contribution to the asymmetry in parity-violating electron scattering and the &#947; -W &#177; box is an important radiative correction in &#946;-decay which must be implemented to extract V ud of the Standard Model from 0 + &#8594; 0 + super-allowed nuclear &#946;-decays.</p><p>The proton form factors are fundamental to hadronic physics. Understanding the QED expansion, the role of twophoton exchange, and the scale of radiative corrections at higher Q 2 will be crucial in future studies at FAIR, JLab, EIC, and elsewhere. The charge-averaged yield eliminates all charge-odd radiative corrections including the leading terms of two-photon exchange, which cannot be calculated with current theories. Measuring the ratio of positron-proton to electron-proton scattering is sensitive to the charge-odd radiative corrections and insensitive to the charge-even radiative corrections. Together they help to study radiative corrections and unravel the proton form factors. TPEX, will provide access to both charge-odd and charge-even measurements at higher Q 2 .</p><p>The discrepancy in the form factor ratio has not been resolved and the role played by two-photon exchange continues to be widely discussed within the nuclear physics community <ref type="bibr">[19,</ref><ref type="bibr">[30]</ref><ref type="bibr">[31]</ref><ref type="bibr">[32]</ref><ref type="bibr">[33]</ref>. Further measurements and theoretical work on the role of two-photon exchange on the proton form factors are clearly needed. However, measurements at higher Q 2 and smaller , where the discrepancy is clear and TPE are expected to be larger, are difficult as the cross sections decrease rapidly. In addition, there are not many laboratories capable of providing both electron and positron beams with sufficient intensity.</p><p>The best, and for the foreseeable future only, opportunity is at DESY. This proposal outlines an experiment that could measure R 2&#947; at Q 2 up to 4.6 (GeV/c) 2 or higher, and below 0.1 where the form factor discrepancy is clear (see Fig. <ref type="figure">1</ref>). Such an experiment would overlap with the existing OLYMPUS data as a cross-check and would map out the two-photon exchange contribution over a broad range in Q 2 and to provide data to constrain theoretical calculations.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2">Proposed experiment</head><p>A schematic overview of the TPEX experimental setup is shown in Fig. <ref type="figure">8</ref>. The electron or positron beam enters the the vacuum chamber along the beamline (upper-right) and passes through the 20 cm long liquid hydrogen target (Sect. 2.1) before reaching the beamdump (Sect. 2.5).</p><p>At &#177;8 &#8226; there are 3 m long beampipes that connect the scattering chamber to the lead collimators before the Cherenkov detectors, used to monitor the luminosity (Sect. 2.4). These beamlines are under vacuum and reduce the multiple scattering for the relatively low energy (30-50 MeV) M&#248;ller and Bhabha scattered leptons. Ten scattered particle spectrometers are placed at polar angles of 30 &#8226; , 50 &#8226; , 70 &#8226; , 90 &#8226; , and 110 &#8226; to the left and right of the beam axis with the front face of the calorimeter modules at a radius of 1 m from the target. Each spectrometer consists of a 5 &#215; 5 array of lead tungstate crystals calorimenter (Sect. 2.2) and two planes of GEM detector (Sect. 2.3).</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.1">Liquid hydrogen target and scattering chamber</head><p>Figure <ref type="figure">9</ref> depicts the conceptual design of the liquid hydrogen target system. Figure <ref type="figure">9a</ref> provides a schematic overview of the target system, which consists of the scattering chamber, the cryo-cooler system, and the 20 cm long, and 2 cm wide target cell. The dimensions of the scattering chamber windows are determined from the solid angle subtended by the calorimeters. The two side exit windows cover the polar angles for the lead tungstate calorimeters in the range of 25 &#8226; &lt; &#952; &lt; 120 &#8226; . At the end of the 3 m long beam pipes leading to the luminosity monitors are two small exit windows cover a range of 7 &#8226; &lt; &#952; &lt; 9 &#8226; . The vertical dimensions of the two side exit windows cover an azimuthal angle of &#966; = 0 &#8226; &#177; 10 &#8226; . To maximize rigidity and withstand the enormous force from atmospheric pressure, as well as to avoid welded and bolted joints, we propose to machine the scattering chamber from a single piece of aluminum.</p><p>Details of the liquid hydrogen target system are shown in Fig. <ref type="figure">9b</ref>. The cryo-cooler/condenser combination will closely follow the successful MUSE design <ref type="bibr">[34]</ref>. We will therefore use the CH110-LT single-stage cryo-cooler from Sumitomo Heavy Industries Ltd <ref type="bibr">[35]</ref> for refrigeration. This cryo-cooler has a cooling power of 25 W at 20 K, which is more than sufficient to cool down and fill the 70 ml LH 2 target cell in approximately 2 h <ref type="bibr">[34]</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.2">Lead tungstate calorimeters</head><p>For the proposed experiment, we are capitalizing on the R&amp;D experience <ref type="bibr">[36,</ref><ref type="bibr">37]</ref> gained from the CMS experiment and its subsequent applications by the Bonn and Mainz groups at CEBAF <ref type="bibr">[38]</ref> and for PANDA <ref type="bibr">[39]</ref>. We plan to utilize ten 5 &#215; 5 arrays of lead tungstate (PbWO 4 ) crystals, totaling 250 crystals. By employing the central 3 &#215; 3 array of crystals within each 5&#215;5 array to define the acceptance, we achieve a solid angle of 3.6 msr at each angle. With a 20 cm long liquid hydrogen target, the acceptance range spans &#177;5.7 &#8226; in both polar and azimuthal angles. Consequently, the data obtained will be averaged over a small range in Q 2 and . Fig. 10 The prototype of the 5 &#215; 5 array of lead tungstate crystals calorimenter tested at DESY</p><p>We plan to use crystals with dimensions of 2 &#215; 2 &#215; 20 cm 3 . With a density of 8.3 g&#8226;cm -3 , each crystal weighs approximately 664 g, resulting in a total weight of 16.6 kg for a 5 &#215; 5 array of crystals. Lead tungstate has a radiation length X 0 = 0.8904 cm, so these crystals are approximately 22.5 X 0 for good longitudinal electromagnetic shower confinement. The Moli&#232;re radius is 1.959 cm, so using just the central 3 &#215; 3 array of crystals for acceptance, the outer ring of crystals contains the transverse shower adequately. Considering the nuclear interaction length of lead tungstate, which is &#955; I = 20.28 cm, the crystals are roughly 0.986 &#955; I . For the lepton energy range of interest, the energy resolution achieved with lead tungstate is approximately 2%.</p><p>The initial tests of the lead tungstate crystals calorimeter prototype (Fig. <ref type="figure">10</ref>) at DESY have demonstrated reliable performance and a reconstructed energy resolution that is compatible with the requirements of TPEX. Detailed information regarding these tests can be found in Refs. <ref type="bibr">[40,</ref><ref type="bibr">41]</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.3">GEM detectors</head><p>In addition to the lead tungstate crystals calorimenter, each scattered particle spectrometer is equipped with two planes of Gas Electron Multiplier (GEM) with two-dimensional readout. Thin absorbers will be placed between the target and the GEMs to stop low-energy M&#248;ller or Bhabha leptons.</p><p>The GEMs provide spatial information of the traversing charged particle at the 100 micrometer precision level. By combining the hits on two GEM planes, a track segment is formed, providing directional information from the impact point on the calorimeter back to the event origin in the target. This serves to effectively suppress charged-particle backgrounds originating from regions other than the target. Furthermore, the GEM detectors are insensitive to neutral particles, making them effective in providing a veto against photons and neutrons. Additionally, by incorporating the calorimeter hit as a third tracking point, the efficiency of each component can be measured</p><p>An active area of slightly more than 20&#215;20 cm 2 is required to fully cover the area of the calorimeter entrance. A total of 20 elements is required to instrument ten calorimeter arms.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.4">Luminosity and beam alignment monitor</head><p>The relative luminosity between the electron and positron running modes is the crucial normalization for the proposed measurement. The luminosity could be monitored by a pair of small-angle detectors positioned downstream on either side of the beamline. This approach was also used in the OLYM-PUS experiment <ref type="bibr">[42]</ref>, and based on the lessons learned from that experiment, could be improved substantially. Given the running conditions of the proposed measurement, we favor a pair of quartz Cherenkov counters positioned 8 &#8226; from the 11 Whereas the forward monitors in OLYMPUS had an event per bunch rate well below 1, the TPEX monitors will see 10 4 M&#248;ller or Bhabha events per bunch crossing Fig. <ref type="figure">12</ref> Schematic for the proposed luminosity monitor, consisting of two quartz Cherenkov detectors with an acceptance defined by 1 cm radius apertures in high-Z collimators beamline to monitor the rates of M&#248;ller and Bhabha scattering from atomic electrons in the target.</p><p>A monitor placed at 8 &#8226; has a number of advantages relative to the 1.3 &#8226; placement of the OLYMPUS luminosity monitors. First, at 8 &#8226; , the M&#248;ller and Bhabha cross sections are only a few percent different, whereas for the OLYM-PUS monitors, which covered the symmetric angle (90 &#8226; in the center-of-mass frame), the two cross sections differed by over 50%, with significant angular dependence. Second, the M&#248;ller/Bhabha rate completely dwarfs the e &#177; p elastic scattering rate, meaning that it is really only sensitive to QED processes. No form factors or any other hadronic corrections 1 are needed to calculate the M&#248;ller and Bhabha cross sections. Third, the sensitivity to alignment scales as 1/ sin &#952; , meaning the monitor will be much more robust to small misalignments, which were a significant challenge for the OLYMPUS luminosity monitor.</p><p>A schematic layout of the design is shown in Fig. <ref type="figure">12</ref>. The monitor consists of two quartz Cherenkov detectors, which act as independent monitors. Cherenkov detectors were chosen because they are widely used for monitoring in high-rate applications, such as in parity-violating electron scattering <ref type="bibr">[43,</ref><ref type="bibr">44]</ref>. The two detectors operate independently and can 1 Other than the radiative correction from vacuum polarization. Fig. <ref type="bibr">13</ref> Schematic view of a possible beamdump/Faraday cup for TPEX cross-check each other, helping to reduce systematic errors from beam alignment.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="2.5">Beamdump/Faraday cup</head><p>A new extracted beam facility from DESY II will need a beamdump. Figure <ref type="figure">13</ref> shows the conceptual design of the beamdump for TPEX experiment. Assuming a maximum current of 100 nA and a beam energy of 7 GeV the maximum power to be handled is 700 W. To contain the showering. the beamdump used to have order of 5 Moli&#232;re radii laterally and order of 25 radiation lengths longitudinally.</p><p>To augment the luminosity measurement proposed in Sect. 2.4 it is considered to modify the beamdump to also function as a Faraday cup to integrate the charge that passes through the target. Then, assuming the length of the target cell and density of liquid hydrogen are known, a measure of the luminosity can be obtained online. As shown in Fig. <ref type="figure">13</ref>, an insulated ring held at negative voltage of a few hundred volts is needed to suppress secondary emission from back scattering out of the Faraday cup.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="3">Plans and expectations</head><p>We propose to commission the experiment using 2 GeV electrons. We do this to commission the electronics, detectors, and data acquisition system taking advantage of the relatively high cross section at 2 GeV. About 2 weeks of beam time is required for this commissioning after the experiment was installed and surveyed. We would also like a brief run (few days) with positrons to verify that the beam alignment and performance do not change with positron running. The commissioning run (including a few days with positrons) would also allow a crosscheck of the OLYMPUS data at 30 &#8226; , 50 &#8226; , and 70 &#8226; and give a modest extension in Q 2 up to 2.7 (GeV/c) 2 .</p><p>Table <ref type="table">1</ref> shows Q 2 , , differential cross section, and event rate expected for one day of running for the proposed  left/right symmetric configuration with 2 GeV lepton beams averaging 40 nA on a 20 cm liquid hydrogen target and using just the central 3 &#215; 3 array of crystals to calculate the acceptance area.</p><p>The main TPEX run would be made at 3.0 GeV and would require approximately 6 weeks (2 weeks with electrons and 4 weeks with positrons in total) to collect the required data. Table <ref type="table">2</ref> shows Q 2 , , differential cross section, and event rate expected for one day of running for the proposed configuration with 3 GeV lepton beams. This would extend the measurements to Q 2 = 4.57 (GeV/c) 2 where the form factor ratio discrepancy is large. The 6 weeks could be divided into shorter periods if that fit better with the DESY synchrotron schedule though longer, uninterrupted runs would be preferable. To minimize systematics we would like to switch between positron and electron running as frequently as possible (e.g. 1 day positron, 1 day electron, and 1 day positron repeating).</p><p>The Q 2 range that the proposed TPEX experiment would be capable of reaching is shown in Fig. <ref type="figure">14</ref> for the 2 and 3 GeV runs of this proposal. The reach with TPEX can be seen in relation to the discrepancy in the form factor ratio. With additional crystals at back angles the 4 GeV runs would also be possible in a reasonable time frame.</p><p>The TPEX experiment at DESY would also measure the charge-averaged cross section just like the recent result from OLYMPUS (see Fig. <ref type="figure">6</ref>). As mentioned above this cross sec-14 Proton form factor ratio as before but also showing the Q 2 range accessible with the proposed TPEX configuration at 2 and 3 GeV. The 4 GeV range would be possible with additional crystals Fig. <ref type="bibr">15</ref> Charge-averaged cross section divided by the dipole cross section from OLYMPUS and expected uncertainties and coverage from TPEX at 2 and 3 GeV tion is insensitive to charge-odd radiative corrections including "hard" two-photon exchange terms. Thus, it provides a more robust measure of the proton form factors. The expected charge-averaged cross section uncertainties (assuming dipole cross section) are shown in Fig. <ref type="figure">15</ref> for TPEX assuming 6 days of running at 2 GeV and 6 weeks of running at 3 GeV with only 50% data collection efficiency. The recent OLYMPUS results are also shown.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head n="4">Conclusion</head><p>The observed discrepancy in the proton form factor ratio presents a fundamental challenge in nuclear physics and quantum electrodynamics (QED). Despite the inclusion of leading order QED radiative corrections, these corrections alone have proven insufficient to resolve the discrepancy. This suggests that higher order corrections might be necessary to achieve a comprehensive understanding of the phenomenon. Additionally, it is plausible that more detailed models for the intermediate hadronic state could be required to accurately account for the observed deviation. Furthermore, it is crucial to consider the possibility of alternative processes that may contribute to the observed discrepancy.</p><p>To address this issue and gain further insights into the proton form factors at higher momentum transfers, the establishment of an extracted positron and electron beam facility at Deutsches Elektronen-Synchrotron (DESY) would offer a unique opportunity. Such a facility would enable the measurement of the two-photon exchange contribution to elastic lepton-proton scattering across a kinematic range where the evident discrepancy is prominent. The proposed TPEX experiment outlines an initial plan for an experimental configuration that could help resolve this issue and provide insight to the radiative corrections needed to understand the proton form factors at momentum transfers.</p></div></body>
		</text>
</TEI>
