skip to main content
US FlagAn official website of the United States government
dot gov icon
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
https lock icon
Secure .gov websites use HTTPS
A lock ( lock ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.


Title: Influence of Internal Bond Rotation on Ultrafast IR Anisotropy Measurements and the Internal Rotational Potential
Award ID(s):
2319637
PAR ID:
10513292
Author(s) / Creator(s):
; ;
Publisher / Repository:
J. Phys. Chem. B
Date Published:
Journal Name:
The Journal of Physical Chemistry B
Volume:
128
Issue:
1
ISSN:
1520-6106
Page Range / eLocation ID:
280 to 286
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. The aim of this study is to develop an internal-external correlation model for internal motion estimation for lung cancer radiotherapy. Deformation vector fields that characterize the internal-external motion are obtained by respectively registering the internal organ meshes and external surface meshes from the 4DCT images via a recently developed local topology preserved non-rigid point matching algorithm. A composite matrix is constructed by combing the estimated internal phasic DVFs with external phasic and directional DVFs. Principle component analysis is then applied to the composite matrix to extract principal motion characteristics, and generate model parameters to correlate the internal-external motion. The proposed model is evaluated on a 4D NURBS-based cardiac-torso (NCAT) synthetic phantom and 4DCT images from five lung cancer patients. For tumor tracking, the center of mass errors of the tracked tumor are 0.8(±0.5)mm/0.8(±0.4)mm for synthetic data, and 1.3(±1.0) mm/1.2(±1.2)mm for patient data in the intra-fraction/inter-fraction tracking, respectively. For lung tracking, the percent errors of the tracked contours are 0.06(±0.02)/0.07(±0.03) for synthetic data, and 0.06(±0.02)/0.06(±0.02) for patient data in the intra-fraction/inter-fraction tracking, respectively. The extensive validations have demonstrated the effectiveness and reliability of the proposed model in motion tracking for both the tumor and the lung in lung cancer radiotherapy. 
    more » « less
  2. Seventy‐five days of sea surface height measurements made by the Surface Water and Ocean Topography (SWOT) mission from 7 September to 21 November 2023 are used to explore SWOT's capability of observing internal tides. Mode‐1 internal tides are mapped by our updated mapping technique. SWOT‐75d represents a 75‐day instantaneous model. Nadir‐30y is constructed using 30 years of nadir altimetry data from 1993 to 2022 and represents a climate normal. The nadir altimetry data in 2023 are used for model evaluation. Despite its large errors, SWOT‐75d reveals the basic features of the global mode‐1 internal tide field, and causes positive variance reduction in regions of strong internal tides. Nadir‐30y performs better overall, but SWOT‐75d performs better in the tropical South Atlantic Ocean, the central North Pacific Ocean, and the Melanesian region. Evaluation using seasonally subsetted altimetry data reveals that internal tides have significant temporal variations. SWOT‐75d performs the best in fall, because the model is constructed using data largely in fall. SWOT‐75d has large phase anomalies, which are spatially smoothed and used to adjust the phases in Nadir‐30y. The phase‐adjusted model can better make internal tide correction for SWOT and its performance is improved by 20%. Our results demonstrate that (a) mode‐1 internal tides can be extracted from 75 days of SWOT data by our mapping technique, and (b) the instantaneous internal tide model can be used to improve internal tide correction for SWOT. 
    more » « less