<?xml-model href='http://www.tei-c.org/release/xml/tei/custom/schema/relaxng/tei_all.rng' schematypens='http://relaxng.org/ns/structure/1.0'?><TEI xmlns="http://www.tei-c.org/ns/1.0">
	<teiHeader>
		<fileDesc>
			<titleStmt><title level='a'>Heterogeneous mantle-derived helium isotopes in the Canary Islands and other ocean islands</title></titleStmt>
			<publicationStmt>
				<publisher>GSA</publisher>
				<date>09/18/2020</date>
			</publicationStmt>
			<sourceDesc>
				<bibl> 
					<idno type="par_id">10522730</idno>
					<idno type="doi">10.1130/G47676.1</idno>
					<title level='j'>Geology</title>
<idno>0091-7613</idno>
<biblScope unit="volume">49</biblScope>
<biblScope unit="issue">2</biblScope>					

					<author>James MD Day</author><author>David R Hilton</author>
				</bibl>
			</sourceDesc>
		</fileDesc>
		<profileDesc>
			<abstract><ab><![CDATA[<title>Abstract</title> <p>Consistent 3He/4He ratios have been measured for &gt;25 years in geothermal fluids and gases from Cumbre Vieja, La Palma (9.4 ± 0.1RA, where RA is the 3He/4He of air), and Teide, Tenerife (6.8 ± 0.3RA), Canary Islands. Both locations are characterized by similar CO2/3He (∼2 to 4 × 109), mantle-like δ13C (−3.3‰ to −4.4‰) and CO2 output (0.1–0.2 × 1010 mol yr–1). Helium isotopic differences between the islands cannot be explained by differential aging and 4He ingrowth in their mantle sources. Instead, distinct He reservoirs exist, with a high-μ (HIMU)–type mantle source for La Palma and a more enriched mantle, with possible lithospheric mantle influence, for Tenerife. Geothermal samples from the Canary Islands record a present-day He distribution distinct from higher 3He/4He in olivine from older eastern Canary Island lavas, indicating temporal variability in sources. Comparison of geothermal sample data versus olivine, pyroxene, and glass He isotope data for the Canary Islands, Azores, Cape Verde, Hawaiian islands, and Iceland reveals generally good correspondence, even across &gt;1 m.y. of stratigraphy. However, in addition to the Canary Islands, there are examples of inter-island heterogeneity for He isotopes at Hawaii, the Azores, and within Iceland, preserved in hydrothermal samples, minerals, and glasses. In particular, in northwest Iceland, olivine separates from older lavas preserve higher 3He/4He than present-day geothermal samples from the same region. This difference likely reflects a reduced mantle-derived 3He input to Icelandic magmatism since the Miocene. Temporal variability in 3He/4He, assessed using geothermal and geological materials in conjunction, offers a powerful tool for examining heterogeneity and temporal evolution of mantle sources at intraplate volcanoes.</p>]]></ab></abstract>
		</profileDesc>
	</teiHeader>
	<text><body xmlns="http://www.tei-c.org/ns/1.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink">
<div xmlns="http://www.tei-c.org/ns/1.0"><head>INTRODUCTION</head><p>Ocean-island basalts (OIBs) and intraplate basalts are known to sample mantle reservoirs with variable 3 He/ 4 He ratios (&lt;5 to 50 R A , where R A is the 3 He/ 4 He of air, 1.38 &#215; 10 -6 ; e.g., <ref type="bibr">Kurz et al., 1982;</ref><ref type="bibr">Stuart et al., 2003)</ref>. The cause of helium isotopic variability and the ways in which it is related to magmatism are not well understood, but differences relative to mid-oceanic ridge basalts (MORBs; 8 &#177; 1R A ; <ref type="bibr">Graham;</ref><ref type="bibr">2002)</ref> imply the existence of both primordial 3 He-rich, less-degassed reservoirs and high (U + Th)/ 3 He recycled mantle sources, relative to the depleted MORB mantle (DMM). Less-degassed, low (U + Th)/ 3 He reservoirs likely occur deeper than the mantle transition zone (e.g., <ref type="bibr">Timmerman et al., 2019)</ref>, although the mechanisms by which these sources are preserved over Earth history are uncertain. Conversely, high (U + Th)/ 3 He sources can occur in both oceanic and continental lithosphere, leading to highly heterogeneous 3 He/ 4 He ratios <ref type="bibr">(Moreira and Kurz, 2001;</ref><ref type="bibr">Day et al., 2005</ref><ref type="bibr">Day et al., , 2015))</ref>.</p><p>Helium isotopic analysis of OIBs occurs both through liberation of gas within olivine and pyroxene grains or glass (hereafter termed minerals and glass), or through direct sampling of geothermal fluids and gases. An advantage of minerals and glass is that they trap He during crystallization of melts and can potentially preserve the He isotope character of their sources over long time periods (&gt;100 m.y.; e.g., <ref type="bibr">Stroncik et al., 2017)</ref>. Disadvantages are the addition of radiogenic and cosmogenic helium over time. Geothermal samples preserve the characteristics of mantle-derived volatiles at the present day, but, as with minerals and glass, they are susceptible to air contamination and other modification processes. These different media provide complementary information on both the spatial and temporal 3 He/ 4 He variation for individual and global OIB localities. Here, we present new noble gas, CO 2 , and &#948; 13 C values, where &#948; 13 C = ([ 13 C/ 12 C sample ]/[ 13 C/ 12 C standard ] -1) &#215; 1000, for geothermal samples from La Palma and Tenerife (Canary Islands) to demonstrate helium isotope heterogeneity between the islands, reflecting different mantle sources. Comparison of hydrothermal samples with minerals and glass from global OIB examples also implies significant temporal and spatial helium isotope heterogeneity in their mantle sources.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>SAMPLES AND METHODS</head><p>We collected geothermal samples in summer 2006 at the peak of Teide (3718 m, 28&#176;16&#8242;21&#8243;N, 16&#176;38&#8242;34&#8243;W), Tenerife, and from the Cumbre Vieja (28&#176;42&#8242;06&#8243;N, 17&#176;53&#8242;38&#8243;W), La Palma (Fig. <ref type="figure">1</ref>). Samples were collected in evacuated low-He diffusivity Corning 1720 glass flasks following procedures to minimize atmospheric contamination <ref type="bibr">(Hilton et al., 2002)</ref>. Methods used for analysis of fluids and gas samples are provided in detail in the Supplementary Material 1 . An ultrahigh-vacuum (UHV) extraction line was used to process all samples <ref type="bibr">(Kulongoski and Hilton, 2002)</ref>. Samples were acidified with phosphorus pentoxide for complete release of CO 2 , with abundances corresponding to total dissolved inorganic carbon (DIC). Water vapor was isolated, after which the condensable gas fraction (dominantly CO 2 ) was trapped. A noncondensable gas split was collected in a Pyrex glass break-seal flask for transfer to a VG5400 mass spectrometer. The remaining noncondensable gas was purified, and a calibrated aliquot of this fraction was expanded into an AR-glass break-seal flask for transfer to a MAP 215 noble gas mass spectrometer for He isotope analysis.</p><p>The CO 2 fraction was condensed into a Pyrex break-seal flask for transfer to a dedicated CO 2 clean-up line. Helium, Ne, and C isotopes were measured using previously detailed protocols, with identical external reproducibility <ref type="bibr">(F&#252;ri et al., 2010;</ref><ref type="bibr">Barry et al., 2014)</ref>.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>RESULTS</head><p>We analyzed six hydrothermal fluid samples for He, Ne, and CO 2 compositions: two from La Palma, and four from the summit of Teide (Table <ref type="table">1</ref>). Contents of 4 He for five of the samples were &gt;185 &#215; 10 9 cm 3 g -1 , with only one sample from Teide having lower contents (2.4 &#215; 10 9 cm 3 g -1 ). Contents of 22 Ne were 2 to 125 times lower (1.4-59 &#215; 10 9 cm 3 g -1 ). Helium isotope compositions between Teide (6.1-6.6R A ) and La Palma (8.8-9.3R A ) were distinct, whereas CO 2 / 3 He ratios (2-7.6 &#215; 10 9 ), &#948; 13 C, and Ne isotope compositions were similar. The CO 2 / 3 He ratios were similar to MORB, arc, and OIB (Iceland/Hawaii) geothermal compositions with mantle-like &#948; 13 C values (Fig. <ref type="figure">2</ref>). Neon isotope compositions were close to atmospheric composition, reflecting the incorporation of air-like Ne into the geothermal samples, and so Ne isotopes are not discussed further.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>HELIUM ISOTOPE VARIATIONS IN THE CANARY ISLANDS</head><p>Hydrothermal samples from Teide (Tenerife) and Cumbre Vieja (La Palma) have been sampled for more than 25 yr (e.g., <ref type="bibr">Per&#233;z et al., 1994;</ref><ref type="bibr">Hilton et al., 1997;</ref><ref type="bibr">Alonso et al., 2016;</ref><ref type="bibr">this study)</ref>. This time series for La Palma and Tenerife reveals relatively consistent mantlederived signatures for both locations in terms of CO 2 / 3 He and carbon isotope compositions, and for 3 He/ 4 He. The helium isotope composi-tions have remained at 9.4 &#177; 0.1R A for La Palma geothermal samples and 6.8 &#177; 0.3R A at Teide, implying a consistent mantle He and CO 2 flux to both islands. The effects of seawater or air contamination, which can be significant at some locations (e.g., Santorini, Greece; <ref type="bibr">Moreira et al., 2019)</ref>, are negligible, while degassing processes may have a limited effect on CO 2 / 3 He and C isotope compositions (&#948; 13 C of -3.3&#8240; to -4.3&#8240; in Teide geothermal samples). Prior workers have estimated CO 2 (&#8764;70-84 kT yr -1 ) with 3 He fluxes from Teide of &#8764;0.4-0.9 mol yr -1 , and 3 He fluxes for Cumbre Vieja of 0.6-0.7 mol yr -1 <ref type="bibr">(Padr&#243;n et al., 2012;</ref><ref type="bibr">Alonso et al., 2019)</ref>, translating to 0.12-0.14 and 0.16-0.19 &#215; 10 10 mol yr -1 CO 2 for Cumbre Vieja and Teide, respectively, and representing a minor fraction of total global volcanic degassing (e.g., <ref type="bibr">Kerrick, 2001)</ref>.</p><p>La Palma and Tenerife geothermal samples have 3 He/ 4 He values outside of analytical uncertainties from each other. These differences are not evident from mineral 3 He/ 4 He ratios (La Palma = 9.7-6.6R A ; Tenerife and eastern Canary Islands = 8.6-6.6R A ), which show considerable overlap (Fig. <ref type="figure">1</ref>). A possibility to explain helium isotope variations in geothermal samples is that the mantle source beneath Tenerife has evolved due to aging and ingrowth of 4 He. This would imply that the reservoir remained closed to other He sources for an extended time period. The most logical time of any possible closure would be after the main shield-building phase on Tenerife, when magmatism waned.</p><p>To model closed-system 4 He production, we assumed a maximum closure age equal to the oldest age of shield-building lavas on Tenerife (11.6 Ma), and a magmatic Th/U ratio of 3.6 <ref type="bibr">(Day et al., 2010)</ref>, and U contents similar to mantle peridotites <ref type="bibr">(Day et al., 2015)</ref>. Start-ing with a 3 He/ 4 He ratio of 9.4R A (La Palma), there is negligible change in He isotopic composition over 12 m.y. for reservoirs assumed to have between 0.1 and 100 &#215; 10 9 cm 3 g -1 4 He, with significant changes to the 3 He/ 4 He ratio only occurring at very low initial gas contents (&lt;&lt;0.1 &#215; 10 9 cm 3 g -1 4 He). While radiogenic 4 He ingrowth has undoubtedly occurred to some extent in the sources of Canary Island magmas, it can be ruled out as the primary cause of He isotope variation, given the higher estimated He contents of Canary Island mantle sources <ref type="bibr">(Day and Hilton, 2011)</ref>, and the impracticality of closed-system He isotope evolution in magmatically active regions <ref type="bibr">(Day et al., 2015)</ref>.</p><p>An alternate cause for lower 3 He/ 4 He ratios in Tenerife compared with La Palma geothermal fluids is a difference in mantle source reservoir. Both La Palma and El Hierro have 3 He/ 4 He consistent with coming from a mantle source similar to, or having lower (U + Th)/ 3 He, than DMM <ref type="bibr">(Day and Hilton, 2011;</ref><ref type="bibr">Gurenko et al., 2006)</ref>. The host lavas have high-&#956; (HIMU)-type compositions, based on Sr-Nd-Pb-Os isotope systematics <ref type="bibr">(Day et al., 2010)</ref>. Similar HIMU-type compositions are also observed in the eastern Canary Islands (Tenerife, Gran Canaria); however, trends to lower 143 Nd/ 144 Nd and 206 Pb/ 204 Pb and higher 87 Sr/ 86 Sr and 207 Pb/ 204 Pb have been attributed to contributions from an enriched mantle component (e.g., <ref type="bibr">Hoernle et al., 1991;</ref><ref type="bibr">Simonsen et al., 2000;</ref><ref type="bibr">Gurenko et al., 2006)</ref>.</p><p>The cause of an increased enriched mantle source contribution in the eastern Canary Islands has been suggested to occur from addition of continental lithospheric mantle (CLM) inherited from thermal erosion and delamination of the West African margin during rifting of Pangea <ref type="bibr">(Hoernle et al., 1991)</ref>. Such an origin is consistent with the helium isotope characteristics of Teide, which has He-CO 2 characteristics broadly akin to CLM (Fig. <ref type="figure">2A</ref>; <ref type="bibr">Day et al., 2015)</ref>. Higher 3 He/ 4 He ratios than those measured for Teide have been measured in Tenerife and Gran Canaria olivine separates from older lavas, showing a HIMU-type composition akin to the western Canary Islands (e.g., <ref type="bibr">Hoernle et al., 1991)</ref>. Geothermal samples from La Palma and Tenerife therefore support a changing source composition model for the eastern Canary Islands, indicating that differing mantle sources are being sampled and are persisting beneath the western and eastern Canary Islands to the present day.</p></div>
<div xmlns="http://www.tei-c.org/ns/1.0"><head>HELIUM ISOTOPE VARIATIONS IN OIB</head><p>For more than 40 years, studies have been systematically performed to obtain the helium isotopic compositions of OIBs, typically by measuring gas trapped within minerals and glass. These studies have shown a wide range in 3 He/ 4 He, from low ratios (&lt;8R A ) in some OIBs, such as S&#227;o Miguel (e.g., <ref type="bibr">Moreira et al., 2012)</ref>, to values in excess of 30-47R A in Hawaii, Samoa, and Iceland (e.g., <ref type="bibr">Kurz et al., 1982</ref><ref type="bibr">Kurz et al., , 2004;;</ref><ref type="bibr">Graham, 2002;</ref><ref type="bibr">Macpherson et al., 2005;</ref><ref type="bibr">Jackson et al., 2007;</ref><ref type="bibr">Har&#240;ard&#243;ttir et al., 2018)</ref>.</p><p>It has been established that minerals have He contents that are generally not as high as in their host magmas. Olivine separates with high 3 He/ 4 He from Samoa have gas contents dominated by He and CO 2 -rich fluid inclusions trapped in only a few grains, suggesting that conditions favoring high He concentrations in olivine are rare <ref type="bibr">(Horton et al., 2019</ref>). An alternative is to compare mineral or glass He contents with geothermal sample He contents from the same locality. For example, He contents measured in La Palma olivine grains (1.4-170 &#215; 10 9 cm 3 g -1 ) are typically lower than He contents of geothermal fluids (&gt;180 &#215; 10 9 cm 3 g -1 ). The lower He contents in minerals support the concept of decoupling of C and 3 He in olivine through He diffusion <ref type="bibr">(Horton et al., 2019)</ref>, and they indicate that, even as primary magmatic He contents become diluted during geothermal processes, geothermal samples are a better proxy for CO 2 / 3 He in OIBs. In turn, La Palma and Tenerife geothermal sample compositions are consistent with Canary Island OIBs, having similar CO 2 / 3 He to MORB (Fig. <ref type="figure">2</ref>).  A B 16 18</p><p>There are several OIB localities where a direct comparison can also be made between He isotopic compositions in geothermal samples and those in minerals and glass. These locations include the Canary Islands of La Palma and Tenerife, three of the Azorean islands (S&#227;o Miguel, Terceira, Graciosa), Cape Verde (Fogo), Hawaii (K lauea and Loihi Seamount), and numerous localities in Iceland. We compared the average compositions of the geothermal samples at the localities and the variance of the 3 He/ 4 He ratios (as 2&#963; errors) with those of minerals and glass considered to be related to the geothermal localities (Fig. <ref type="figure">3</ref>). Most locations suffer from small number statistics, yet they show that, for the majority, mineral and glass compositions have average compositions that are broadly similar to corresponding geothermal samples.</p><p>La Palma and the three Azores locations have helium isotope ratios in geothermal samples generally higher than minerals. This can be explained if concomitant degassing and assimilation processes preferentially affected mineral He isotope compositions (e.g., <ref type="bibr">Day and Hilton, 2011)</ref>. In contrast, in northwest Iceland, recently sampled hydrothermal media have lower 3 He/ 4 He than the average composition of minerals taken from Miocene lavas located there. These differences likely relate to the lavas being fed by magmas from a mantle source with higher 3 He/ 4 He than that beneath Iceland today (e.g., <ref type="bibr">Har&#240;ard&#243;ttir et al., 2018)</ref>.</p><p>Analyses of helium isotope variations through &gt;2500 m of lava stratigraphy at Mauna Kea (Hawaiian Islands) have revealed changes from a generally high (up to &#8764;25R A ) to a lower 3 He/ 4 He composition (8R A ) with time <ref type="bibr">(Kurz et al., 2004)</ref>. These variations have been interpreted to reflect heterogeneities in an upwelling mantle plume over short (&#8764;15 k.y.) and intermediate (&#8764;0.38 m.y.) time scales <ref type="bibr">(Kurz et al., 2004)</ref>. Comparisons of geothermal fluids with minerals and glass show that helium isotope compositional variability also occurs in Iceland, from the eruption of the first exposed lavas to the present day. Collectively, these results support "pulsed" high 3 He/ 4 He in localities such as Iceland, as well as Hawaii, and they also suggest changing He compositions with time, even in low-3 He/ 4 He OIBs, such as the Canary Islands.</p><p>Helium isotope variability on million-year time scales occurs at hotspot localities for which there are ample data: Iceland, Hawaii, and now the Canary Islands. Denser sampling might yield similar temporal trends elsewhere and could shed light on mantle heterogeneity and the geochemical evolution of mantle hotspots in general. For example, ca. 60 Ma lavas from the North Atlantic igneous province <ref type="bibr">(Stuart et al., 2003)</ref> and ca. 132 Ma lavas associated with the Parana-Etendeka continental flood basalt (southern Africa and South America; <ref type="bibr">Stroncik et al., 2017)</ref> have been shown to have high 3 He/ 4 He. In the absence of geothermal fluids for these localities, it is possible that the He compositions preserved in their minerals reflect distinct periods of high-3 He/ 4 He magmatism. Where it is possible to do so, combining helium isotopic measurements of geothermal and geological samples is a promising approach for evaluating temporal isotopic trends at hotspot localities. </p></div><note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_0"><p>Downloaded from http://pubs.geoscienceworld.org/gsa/geology/article-pdf/49/2/120/5215452/120.pdf by UC San Diego Library user</p></note>
			<note xmlns="http://www.tei-c.org/ns/1.0" place="foot" xml:id="foot_1"><p>Printed in USADownloaded from http://pubs.geoscienceworld.org/gsa/geology/article-pdf/49/2/120/5215452/120.pdf by UC San Diego Library user</p></note>
		</body>
		</text>
</TEI>
