Title: A brief report on the effects of vasoactive agents on peripheral venous waveforms in a porcine model
Objectives

Non-invasive venous waveform analysis (NIVA) is a recently described, novel technique to assess intravascular volume status. Waveforms are captured with a piezoelectric sensor; analysis in the frequency domain allows for calculation of a “NIVA value” that represents volume status. The aim of this report was to determine the effects of vasoactive agents on the venous waveform and calculated NIVA values.

Design

Porcine experimental model.

Setting

Operating theatre.

Participants

A piezoelectric sensor was secured over the surgically exposed saphenous vein in eight anesthetized pigs.

Main outcome measures

NIVA value, pulmonary capillary wedge pressure (PCWP), and mean arterial pressure prior to and post intravenous administration of 150–180 µg of phenylephrine or 100 µg of sodium nitroprusside.

Results

Phenylephrine led to a decrease in NIVA value (mean 9.2 vs. 4.6, p < 0.05), while sodium nitroprusside led to an increase in NIVA value (mean 9.5 vs. 11.9, p < 0.05). Mean arterial pressure increased after phenylephrine ( p < 0.05) and decreased after sodium nitroprusside ( p < 0.05). PCWP did not change significantly after phenylephrine ( p = 0.25) or sodium nitroprusside ( p = 0.06).

Conclusions

Vasoactive agents lead to changes in non-invasively obtained venous waveforms in euvolemic pigs, highlighting a potential limitation in the ability to NIVA to estimate static volume in this setting. Further studies are indicated to understand the effects of vasoactive agents in the setting of hypovolemia and hypervolemia.

 
more » « less
PAR ID:
10547842
Author(s) / Creator(s):
 ;  ;  ;  ;  ;  ;  ;  ;  
Publisher / Repository:
SAGE Publications
Date Published:
Journal Name:
JRSM Cardiovascular Disease
Volume:
9
ISSN:
2048-0040
Format(s):
Medium: X
Sponsoring Org:
National Science Foundation
More Like this
  1. null (Ed.)
    Abstract Analysis of peripheral venous pressure (PVP) waveforms is a novel method of monitoring intravascular volume. Two pediatric cohorts were studied to test the effect of anesthetic agents on the PVP waveform and cross-talk between peripheral veins and arteries: (1) dehydration setting in a pyloromyotomy using the infused anesthetic propofol and (2) hemorrhage setting during elective surgery for craniosynostosis with the inhaled anesthetic isoflurane. PVP waveforms were collected from 39 patients that received propofol and 9 that received isoflurane. A multiple analysis of variance test determined if anesthetics influence the PVP waveform. A prediction system was built using k-nearest neighbor (k-NN) to distinguish between: (1) PVP waveforms with and without propofol and (2) different minimum alveolar concentration (MAC) groups of isoflurane. 52 porcine, 5 propofol, and 7 isoflurane subjects were used to determine the cross-talk between veins and arteries at the heart and respiratory rate frequency during: (a) during and after bleeding with constant anesthesia, (b) before and after propofol, and (c) at each MAC value. PVP waveforms are influenced by anesthetics, determined by MANOVA: p value  < 0.01, η 2 = 0.478 for hypovolemic, and η 2 = 0.388 for euvolemic conditions. The k-NN prediction models had 82% and 77% accuracy for detecting propofol and MAC, respectively. The cross-talk relationship at each stage was: (a) ρ = 0.95, (b) ρ = 0.96, and (c) could not be evaluated using this cohort. Future research should consider anesthetic agents when analyzing PVP waveforms developing future clinical monitoring technology that uses PVP. 
    more » « less
  2. Abstract

    In two-thirds of intensive care unit (ICU) patients and 90% of surgical patients, arterial blood pressure (ABP) is monitored non-invasively but intermittently using a blood pressure cuff. Since even a few minutes of hypotension increases the risk of mortality and morbidity, for the remaining (high-risk) patients ABP is measured continuously using invasive devices, and derived values are extracted from the recorded waveforms. However, since invasive monitoring is associated with major complications (infection, bleeding, thrombosis), the ideal ABP monitor should be both non-invasive and continuous. With large volumes of high-fidelity physiological waveforms, it may be possible today to impute a physiological waveform from other available signals. Currently, the state-of-the-art approaches for ABP imputation only aim at intermittent systolic and diastolic blood pressure imputation, and there is no method that imputes the continuous ABP waveform. Here, we developed a novel approach to impute the continuous ABP waveform non-invasively using two continuously-monitored waveforms that are currently part of the standard-of-care, the electrocardiogram (ECG) and photo-plethysmogram (PPG), by adapting a deep learning architecture designed for image segmentation. Using over 150,000 min of data collected at two separate health systems from 463 patients, we demonstrate that our model provides a highly accurate prediction of the continuous ABP waveform (root mean square error 5.823 (95% CI 5.806–5.840) mmHg), as well as the derived systolic (mean difference 2.398 ± 5.623 mmHg) and diastolic blood pressure (mean difference − 2.497 ± 3.785 mmHg) compared to arterial line measurements. Our approach can potentially be used to measure blood pressure continuously and non-invasively for all patients in the acute care setting, without the need for any additional instrumentation beyond the current standard-of-care.

     
    more » « less
  3. Abstract

    Based on a one-dimensional (1D) uniform model of the arterial tree, various machine-learning techniques have been explored to reconstruct aortic pressure waveform (APW) from peripheral pressure waveform (PPW). This study aims to examine the feasibility of such reconstruction. Based on a 1D uniform vibrating-string model, transfer function (TF) of PPW to APW contains four harmonics-dependent parameters: value and phase of reflection coefficient (i.e., load impedance) at periphery and transmission parameter and transmission loss in the aorta-periphery section. Pressure waveforms and blood velocity waveforms at the ascending aorta (AA), the carotid artery (CA), and the radial artery (RA) of virtual health subjects at different ages in a prevalidated database are analyzed to calculate (1) reflection coefficient at the CA and the RA as two peripheries, (2) TF for the AA-CA and AA-RA sections, and (3) transmission parameter and transmission loss in the two sections. Harmonics-dependence of the four parameters varies with aging in both sections, and arterial nonuniformity makes it unpractical to configure any mathematical model for their harmonics-dependence. Instead of fluid-loading, arterial nonuniformity greatly affects transmission loss. Compared with higher harmonics, transmission loss dramatically alters reconstructed APW. A 1D uniform model allows accurate reconstruction of APW from PPW, with a caveat that baseline values of the four parameters at different harmonics under different cardiovascular (CV) conditions need to be established a priori. Alternatively, based on the baseline values, PPW can be directly utilized for inferring CV conditions.

     
    more » « less
  4. Abstract Objective

    The development of earlier and less invasive treatments for peripheral arterial disease requires a more complete understanding of vascular responses following a major arterial occlusion. A mechanistic model of the vasculature of the rat hindlimb is developed to predict acute (immediate) changes in vessel diameters and smooth muscle tone following femoral arterial occlusion.

    Methods

    Vascular responses of collateral arteries and distal arterioles to changes in pressure, shear stress, and metabolism are assessed before and after occlusion. The effects of exercise are also simulated and compared with venous flow measurements from WKY rats.

    Results

    The model identifies collateral arteries as the primary contributors to flow compensation following occlusion. Increasing the number of capillaries has minimal effect on blood flow while increasing the number of collateral arteries significantly increases flow, since the primary site of resistance shifts upstream to the collateral arteries following occlusion. Despite significant collateral dilation, calf flow remains below pre‐occlusion levels and the deficit becomes more severe with increased activity.

    Conclusions

    Although unable to compensate fully for an occlusion, the model demonstrates the importance of the shear response in collateral arteries and the metabolic response in the distal microcirculation in acute adaptations to a major arterial occlusion.

     
    more » « less
  5. Abstract Background

    Millions of catheters for invasive arterial pressure monitoring are placed annually in intensive care units, emergency rooms, and operating rooms to guide medical treatment decision-making. Accurate assessment of arterial blood pressure requires an IV pole-attached pressure transducer placed at the same height as a reference point on the patient’s body, typically, the heart. Every time a patient moves, or the bed is adjusted, a nurse or physician must adjust the height of the pressure transducer. There are no alarms to indicate a discrepancy between the patient and transducer height, leading to inaccurate blood pressure measurements.

    Methods

    We present a low-power wireless wearable tracking device that uses inaudible acoustic signals emitted from a speaker array to automatically compute height changes and correct the mean arterial blood pressure. Performance of this device was tested in 26 patients with arterial lines in place.

    Results

    Our system calculates the mean arterial pressure with a bias of 0.19, inter-class correlation coefficients of 0.959 and a median difference of 1.6 mmHg when compared to clinical invasive arterial measurements.

    Conclusions

    Given the increased workload demands on nurses and physicians, our proof-of concept technology may improve accuracy of pressure measurements and reduce the task burden for medical staff by automating a task that previously required manual manipulation and close patient surveillance.

     
    more » « less